Loading...
HomeMy WebLinkAboutT-313804M M aF w m 1 aom o 00 � sQ >- aW W as U0' cc 0 �E Al �N 9I o � a� ao INNN -- — - -- .. — // , E r 2 / h STA. 57 +75.60 C.O.R. STA: 0 +00 2 < 4 5 rfl ��w I Of r .71 k` 7 /1 h 56 4l." " EX. 150 WATT LUMINAIRE AT 30' M.H. TO REMAIN 7 LEGEND POLE ID NO. STREET TYPE M —C —III H.P.S. LUMINAIRE, ARM ( AND ALUMINUM DAVIT STYLE POLE DISTRIBUTION LIGHT BASE AND JUNCTION BOX (TYPE 1 SHOWN) ® WITH CONCRETE PAD AND LOCKING LID NEW 2 — #6, NEW 1 — #8 GREEN - - - -- PVC CONDUIT (SEE WIRING SCHEDULE) 1752C ® TYPE 1 JUNCTION BOX WITH CONCRETE PAD 24.8' LT. * 150 AND LOCKING LID PER DETAIL ON SHEET IL3 AWIRE NOTE 0 10 zo ao O CONSTRUCTION NOTE GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT CITY OF RENTON STANDARD SPECIFICATIONS AND STANDARD DETAILS. 2. EXISTING ILLUMINATION SYSTEM SHALL BE KEPT OPERATIONAL DURING HOURS OF DARKNESS. TEMPORARY SPLICES OF ILLUMINATION CONDUCTORS MAY BE ALLOWED WITH APPROVAL FROM THE ENGINEER. CONSTRUCTION NOTES OCUT ILLUMINATION CONDUCTORS IN EXISTING JUNCTION BOX AT APPROX. STA. 58 +00 AND PULL BACK TO EXISTING JUNCTION BOX TO SOUTH AT APPROX. STA. 56 +16. INTERCEPT EXISTING CONDUIT AND SWEEP INTO NEW JUNCTION BOX PER WIRING SCHEDULE. REPULL EXISTING CONDUCTORS AND INSTALL NEW CONDUCTORS PER WIRING SCHEDULE. OINSTALL FOUNDATION, LIGHT STANDARD AND LUMINAIRE PER DETAILS ON ,SHEETS IL2 AND IL3. FOUNDATION SHALL BE LOCATED TO ENSURE A MINIMUM OF TWO FEET OF CLEARANCE FROM FACE OF CURB TO FACE OF LIGHT STANDARD. NO PORTION OF LIGHT STANDARD BASE PLATE SHALL ENCROACH ONTO SIDEWALK AREA. REMOVE AND REPLACE EXISTING SIDEWALK PANELS AS NECESSARY, ADJUST EXISTING JUNCTION BOX TO FINISHED GRADE, INCLUDING INSTALLING CONCRETE PAD (IF NOT IN �—/ SIDEWALK) AND EXTENDING CONDUITS AS NECESSARY TO MEET LID CLEARANCES SHOWN ON SHEET IL3. SPLICE NEW CONDUCTORS TO EXISTING CIRCUIT INSIDE JUNCTION BOX. POLE SCHEDULE POLE NO. POLE ID NO. STREET POLE LOCATION POLE OFFSET LAMP WATTAGE DISTRIBUTION MOUNTING HEIGHT MAST ARM CIRCUIT NO, NEW 2 — #6, NEW 1 — #8 GREEN REMOVE EX. CONDUCTORS 1 1752C SUNSET 57 +39.5 24.8' LT. * 150 M —C —III 30' 8' EX. NEW 2 — #8; NEW 1—#8 GREEN * APPROXIMATE, SEE CONSTRUCTION ;NOTE NO. 2 FOR OTHER 'OFFSET REQUIREMENTS. WIRING SCHEDULE RUN NO. CONDUIT CONDUCTORS REMARKS 1 EX. " EX. 2 - #6, EX. 1 — #8 GREEN REMAINS UNCHANGED 2 EX. 2" NEW 2 — #6, NEW 1 — #8 GREEN REMOVE EX. CONDUCTORS 3 NEW 2" PVC (SCHEDULE 40) NEW 2 — #6, NEW 1 — #8 GREEN INTERCEPT & REROUTE EX, CONDUIT 4 - NEW 2" PVC (SCHEDULE 40) EX. 2 — #6, EX. 1—#8 GREEN INTERCEPT & REROUTE EX. CONDUIT 5 NEW 2" PVC` (SCHEDULE 40)' NEW 2 — #8; NEW 1—#8 GREEN 6 EX. 2" 1 EX. 2 — #6, EX. 1—#8 GREEN REMOVE AND REPULL EX. CONDUCTORS Z To 31380 RECOMM BED FOR APPROVAL �Mp AS &, Tl CRECORD DOCUMENT B DATE gZ Z H C HERMAN TRAFFIC ENGINEERING BY Cs�,.•/%7. �q DATE 6 •t °•a 30730 r.� BY DATE BY DATE oFSSrONAL C 15324 Southeast 133rd Court, Renton, Washington 98059 425-277-1740 tel. 425-277-5718 fax hte @comcast.net Z Co T- 31j801 BPiMN1�' DEC p d 2147 •�r - FK' �