HomeMy WebLinkAboutT-3190030
O►
s
h
a
0
ITI
e
e
ITEM
.L-
Box
60
o�
Ll- z
NOTES:
00
3E
F--
Diamond Plate Steel - A786
k
u .
All dimensions are
minimum. Exact configurations vory among different manufacturers.
U
'
....
Cp
c°
�E
The noted lid thickeners overall minimums. The Diamond Pattern for Type 1 or Type 2
�.
�E
' �1
Boxes shill be 28X minimum of overall thickness.
vo
o.�
Lid support members shall be welded to the frame.
4000PSI concrete
is allowed if box reinforcement consists of 6 X 6 - W3 X W3 welded
wire fabric welded
to the frame.
When noted in the
contract. Type 2 and Type 3 Boxes shall be provided with 12' deep
extension boxes.
When noted in the
contract. Type 2 Boxes shall be provided with a 10' X 27 1/2" 10
gage divider plate
complete with fasteners.
Non - concrete Boxes may be submitted for approval. Evaluation will include on H -20
Load Test.
J
JUNCTION BOX
DIMENSION TABLE
I c
~
ITEM
QQX TYPE
-
T 1
tfi
TYPE
(L
2
W
Ll
A
Box Outside len th
22
22
33
Z
Box Outside Width
17
17w
22 1Z2
Box Inside Length
18
19
28
~
Box Inside Width
13
14
17
_
W
Lid Length
18
18
26 1/2
Ce
_
Lid Width
13
13
17
PLAN ve•
W
Box Depth
12w
12
12
_
Lid & Frame Depth
5 16
5/16w
5 16
U
Wall Thi knm Min.
1 1 2
1 1 2
1 1 2
We Reinforcement
W-3
W-2.5
W-2.5
_
Legend
See Detoil
See Detail
ISn Dotal
-'
ELEVATION VEw
s
h
a
0
ITI
e
e
ITEM
.L-
Box
60
o�
Ll- z
a
:_
00
3E
F--
Diamond Plate Steel - A786
�z
u .
F— Ll
zW
a'. a.
U
C
Cp
c°
�E
mE
�E
' �1
�` °'
c
vo
o.�
s
h
a
0
ITI
e
e
ITEM
MATERIALS
Box
6000 PSI =x:mte See Notes
Frame
Diamond Plate Steel - A786
Lid Su art
1 Thick StMI C, L w T. - AN
Lid
Diamond Plate Steel - A786
Anchors
Steel Wire or Tee Plate
Reinforcement
ASTM A -82 Steel
*GALVANIZED STEEL
LEGEND DETAIL (Mark W
SIGNALS
LIGHTING
•
TS -LT
TELEMETRY 7RAFnC
SIGNAL SYSTEM LEGEND
For►n Letters with 1/8* Wald
Bead. Grind off Diamond
Pattern before forming
letter.
L IT-A.
r-am.
1LLk*MATION SYSTEM LEGEND
EPDXY FILL
INLINE SPLICE
Le i
C GRAbEL PAD
COWAVED
'T1t7IC01 ASNCIM eac NSTALLATION DETAILS
�' ■ TYPE Y sac
0 TYPE 01' sac
HOOK DETAL FILM SybdKIS
a M..... w
JUNCTION BOX DETAILS
ADOPTED
affor■IMI
Standard plans
IST DATE: 11 /89
DWG. NAME: JR -36 SP PAGE: J016
r-r,,nvv r-11 a
WYE SPLICE
SPLICE KIT
a �
a.
DIAMETER = 7/8"
Nunn wnmww�
4- 7/8 "�I
LOAD LINE
1/4" FUSE ��4"
1/8" 0 1 /8"
CUTTING RINGS
Z
O
ft 4waft*ft
1 9 141
FUSE KIT
FUSE KIT & SPLICE KIT DETAILS
ADOPTED
air w ■nw
� i "
M. JR -12 SP PAGE: JO 13
LIGHTING STANDARD & JUNCTION BOX
7'
ov O ov oov O
•o s ov, oo ��� oov
`oil , o o O Q o v ►v ,V
0
e
PLAN VIEW '° v b ' '
O � � ,0 3
. s e o �
4 �
►o ►0 r o � o �► �
O V o v lov ► p�
STREET LIGHT POLE VJUNCTION BOX
SIDE VIEW
INDIVIDUAL JUNCTION BOX
ov 00 0 0 b�'q 0 V
V, Oiv
►♦ ♦ ♦�
►�� ♦��i�
1'
PLAN VIEW
1'
400 1
4" DEEP
NOTE: CLASS 'B' CONCRETE
TO BE USED IN
CONSTRUCTION OF PAD
CONCRETE PAD DETAILS
ADOPTED
Ciff or ■tro
Standard plans
LST DATE: 10/30/96
DWG. NAME: JR -07 SP PAGE: J008
FFt 0�,t ,
T- 3/Q003
RECOMMENDED FOR APPROVAL
BY DATE
BY DATE
8Y DATE
HIE HERMAN TRAFFIC ENGINEERING
15324 500h.s:e 133rd eon, Re"M wMI101198011 cos'
42S•277•1740 tell. 425- 277 -571 i fu hq@cofflcast.n"
w� w
z•.s
0
0