SERVICE CABINET 0 STA. 0 +86, 26' RT, HOQUTAM AVE
9.
m
av
CL
SERVICE CABINET I.D. NO. 0097 , 100 AMP
3rd
9
Q
N
W
CIRCUIT A -1: 20 A BRANCH BREAKER, 40 A CONTACTOR
n
u- 0.
S
NE
CIRCUIT A -2: 20 A BRANCH BREAKER, 40 A. CONTACTOR
CIRCUIT A -3: 20 A BRANCH BREAKER, 40 A CONTACTOR
x g
7
NE
CIRCUIT A -4: 20 A BRANCH BREAKER, 40 A CONTACTOR
F
a
0
w �
�v
t`
LEGEND
FLAT LENS COBRA HEAD, 240 VOLT, HPS, MEDIUM CUTOFF TYPE
III DISTRIBUTION ON DAVIT POLE WITH 8' ARM. POLE SHALL
MAINTAIN MIN. 10' CLEARANCE TO ANY DRIVEWAY.
WSDOT TYPE II JUNCTION BOX (SEE CITY STD. PLAN #J-11a).
9 +00
STREET LIGHT GENERAL NOTES:
1. ALL WORKS SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD PLANS AND EXIST. STREET LIGHT
SPECIFICATIONS AND THESE PLANS. ON POWER POLE
2. UNLESS OTHERWISE NOlEO, THE LOCATION OF FEATURES SHOWN ARE APPROXIMATE AND THE
EXACT LOCATION WILL BE ESTABLISHED BY THE ENGINEER OR INSPECTOR IN THE FIELD.
3. INSTALL ALL STREET L1GH11NG MATERIALS SHOWN ON THE PLANS, EXCEPT WHERE NOTED. ALL
MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE GRADE OR QUALITY.
4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL
AT THE EARLIEST POSSIBLE DATE.
5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR
SHALL CONTACT ALL PERTINENT U71UTY AGENCIES 48 HOURS BEFORE COMMENCING WORK AND SHALL
COORDINATE THE WORK WITH THE UTIU11ES THROUGHOUT THE PROJECT.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE
CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON
DAMAGE.
7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON FIELD INSPEC110N DIVISION FOR
INSPEC110N PURPOSES, 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL
IT HAS BEEN EXAMINED BY THE INSPECTOR.
8.
ALL
CONDUIT
0
BE PVC SCHEDULE 40 UNLESS OTHERWISE NOTED.
9.
ALL
av
CL
SHALL BE 24 INCHES.
3rd
ST.
17
C
C
AVE NE
HOQUIM
w 'C
Y '�
HOQUIM
AVE NE
NE
4th
x g
7
NE
Dr-,> 6'x6'
3Q
AREA FOR FUTURE SIGNAL CABINET. STA 0 +80,
26' RT.
ST.
V
4th
o
O I
[Z:-,> 4'
DIAMETER RESERVE
AREA FOR FUTURE SIGNAL POLE. STA 0 +51, 32' RT.
as
W
\ c
u
Ec
—
v �
INSTALL
�E
m
CABINET
do CABINET
c N
(3- - #2's) AND
CONDUIT
c CP
(2" SCH 80) SHALL CONNECT
FROM SERVICE CABINET TO NEAREST
P.S.E. POWER SOURCE.
0
a0
LEGEND
FLAT LENS COBRA HEAD, 240 VOLT, HPS, MEDIUM CUTOFF TYPE
III DISTRIBUTION ON DAVIT POLE WITH 8' ARM. POLE SHALL
MAINTAIN MIN. 10' CLEARANCE TO ANY DRIVEWAY.
WSDOT TYPE II JUNCTION BOX (SEE CITY STD. PLAN #J-11a).
9 +00
STREET LIGHT GENERAL NOTES:
1. ALL WORKS SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD PLANS AND EXIST. STREET LIGHT
SPECIFICATIONS AND THESE PLANS. ON POWER POLE
2. UNLESS OTHERWISE NOlEO, THE LOCATION OF FEATURES SHOWN ARE APPROXIMATE AND THE
EXACT LOCATION WILL BE ESTABLISHED BY THE ENGINEER OR INSPECTOR IN THE FIELD.
3. INSTALL ALL STREET L1GH11NG MATERIALS SHOWN ON THE PLANS, EXCEPT WHERE NOTED. ALL
MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE GRADE OR QUALITY.
4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL
AT THE EARLIEST POSSIBLE DATE.
5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR
SHALL CONTACT ALL PERTINENT U71UTY AGENCIES 48 HOURS BEFORE COMMENCING WORK AND SHALL
COORDINATE THE WORK WITH THE UTIU11ES THROUGHOUT THE PROJECT.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE
CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON
DAMAGE.
7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON FIELD INSPEC110N DIVISION FOR
INSPEC110N PURPOSES, 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL
IT HAS BEEN EXAMINED BY THE INSPECTOR.
8.
ALL
CONDUIT
SHALL
BE PVC SCHEDULE 40 UNLESS OTHERWISE NOTED.
9.
ALL
CONDUIT
COVER
SHALL BE 24 INCHES.
COMMENTS
1'lL
%.JI V
J 1.
STREET LIGHT
FLAG NOTES:
ST.
NE
3rd
ST.
h
3rd
ST.
HOQUIM
AVE NE
HOQUIM
AVE NE
HOQUIM
AVE NE
NE
4th
x g
7
NE
Dr-,> 6'x6'
RESERVE
AREA FOR FUTURE SIGNAL CABINET. STA 0 +80,
26' RT.
ST.
NE
4th
o
O I
[Z:-,> 4'
DIAMETER RESERVE
AREA FOR FUTURE SIGNAL POLE. STA 0 +51, 32' RT.
INSTALL
SERVICE
CABINET
do CABINET
NUMBERS. SEVICE CABLES
(3- - #2's) AND
CONDUIT
(2" SCH 80) SHALL CONNECT
FROM SERVICE CABINET TO NEAREST
P.S.E. POWER SOURCE.
'
N
® INSTALL PHOTOCELL ON LUMINAIRE.
Jr I 7
s K a
N
7. ✓ 7 O
o
!j
STREET
LIGHTING
POLE
SCHEDULE
'
POLE
pOLE
POLE
POLE MOUNTING
WATTS
ARM
CIRCUIT
NO.
I.D.#
LOCATION
OFFSET HEIGHT
LENGTH
NO_
1
2862B
STA
0 +86
23' LT 25'
100
8'
A -1
2
28636
STA
2 +58
23' RT 25'
100
8'
A -1
3
2864B
STA
4 +36
23' LT 25'
100
8'
A -1
4
2865B
STA
5 +76
23' RT 25'
100
8'
A -1
5
2867B
STA
0 +90
25.5' LT 25'
100
8'
A-2
6
28668
STA
1+70
25.5' RT 25'
100
8'
A -1
7
2869B
STA
2 +65
23' LT 25'
100
8'
A -1
8
2868H
STA
7+10
40' LT 40'
400
8'
A-2
a
0-
9
2870H
STA
5 +15
40' LT 40'
400
8'
A -2
Q
10
2872H
STA
3+20
40' LT 40'
400
8'
A-2
11
2874H
STA
1+25
40' LT 40'
400
8'
A -2
Y
WIRING
SCHEDULE
}
°D
RUN NO.
CONDUIT
SIZE
CONDUCTOR
COMMENTS
m
2"
SCH.
40
4 — #8 AWG (USE --XLP)
LIGHTING
2 — #10 AWG (USE —XLP)
PHOTOCELL
1 — #8 BARE GROUND
GROUND
®
2"
SCH.
40
2 — #8 AWG (USE —XLP)
LIGHTING
2 — #10 AWG (USE —XLP)
PHOTOCELL
1 — #8 BARE GROUND
GROUND
®
2"
SCH.
40
OPEN (PULL WIRE)
SPARE
s
®
3"
SCH.
40
OPEN (PULL WIRE)
SIGNAL
®
3"
SCH.
80
OPEN (PULL WIRE)
SIGNAL
®
2"
SCH.
40
2 - #8 AWG (USE -XLP)
LIGHTING
20
0 _
1 -#8 REAR GROUND
GROUND
.
STREET
LIGHT SPECIFICATIONS
COMMENTS
1'lL
%.JI V
J 1.
NE
3rd
ST.
NE
3rd
ST.
NE
3rd
ST.
HOQUIM
AVE NE
HOQUIM
AVE NE
HOQUIM
AVE NE
NE
4th
ST.
NE
4th
ST.
NE
4th
ST.
NE
4th
ST.
NORTH
SCALE: Ve m 20'
GRAPHIC SCALE
,o zo 40
( IN FEET )
1 inch = 20 ft.
N E 4TH STREET
az AA
1
1
1
I
1
5 +001
+
I
I
#9 I
I
-)0' O
JCT BOX i ( 5'
EXIST. STREET LIGHT ( I ST. STREET LIGHT
ON POWER POLE (REMOVE)
#5 .7
\ ON POWER POLE (REMOVE)
i
ID
rn
i I EXIST. I i
z + Cl HOUSE I
_ _ _ - --
, - __ — — --� TO BE T- -- - -- -C -� - - -- — -
REMOVE6
.'i��• !r I UTILITIES
W
4 JeF. 2 11 'VV N88'22'1 1 "W < I I W
LL
- -- - -- 4 3 O'yl - -- — i 47.00'
Ll
-- - - -- - -- -------- `-- - -y -'- - _ MEN T - -- I �� ULJ
c, I LiA I I (n LLJ
Cr)
AA
I
1 I STA 2 +15.62 HOQUTAM AVE NE
=STA 6 +60.87 NE THIRD ST I
i - I #6C1 �.
I
w I •- � i I I I
00
0 w 1
I N
I #4 1
w - - - - - -- -- -- j------ - - - - -- I ---- - - - - -- 6 +00 5400
p 20.00 -
�" �VI D E D E= I VE 'Vv ���. �, �'� 0.87
CF)
o +16
N - NE 3RD STREET
I
�. _._. _. - -.___. .. -. -_ .... . -.-- I .. _. _ a-
1(. { 4
Z -°o I r - ; -� - T o • W
i - c 5 WIDE CONC. SIDEWALK
III, I > j
U
1 1 T.B.H Q
Q #7
CYuj 0 I
I � I T
LUA 04 -031
• W ,� i u
+ Q , RECOMMENDED FOR A
! 0 W
eY:
so
t
LDNO o7- ,6-socr j
. ROLL 2A 0�
(A
N
00
v)
46
S88 ?22'11 "E 277.56
ENGINEER:
no c" way, sift too
'i-is PAKL I N G 4.t*' w,��ow "m -18;3
Y)I►(+�i7 ' !1(awllI1hi0
Al: �111'�6(r7�1
ELECT WAL ENC MEERING 11FC► NSJLTW, wwJr lM►>Il��.allll
No. REMSION BY APPR. OA7E
F 11
r
075
CITY OF' RENTON'
DEPARTMENT OF PUBLIC WORKS
SMET LIGHMG Pl"
JERIC�O FLAT
DESIGNED: CBF DATE: 09/23/05 FU NAW:
(MAIM: AAU
CHECKED: CBF SCALE: 1 " =20' FIELD BOOK: PAGE:
APPROVED: wllJ�e�on or .�+aK wlallws SHUT: 20 OF: 22
c-z) - -rw-p io3
0
I
4
y
4
�N
C
>
- 1
N
W