Loading...
HomeMy WebLinkAboutT-337606M M 1 J a v � 1 U a 0 n 0 a M O J 1,111 C!) J Lj V) Q Z C4 Y S 1 J J a g 9 a 0 a s ®0 3 E_ a E- W a c a rn c �I c � a FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS - S.E.C. OR EQUAL - TYPICAL DESIGN "B" JUNCTION BOX SPLICE KITS GROUND LU CLEAR EPDXY SPLICE KITS ON ALL THRU 2" MIN. GROUT WIRE RUNS UNDER BASE 4" CONCRETE PAD #8 BARE COPPER GROUND WIRE 1 - #8 GREEN 2- (SIZED AS REVD) LIGHTING SYSTEM WIRES TO CONTACTOR 5/8 "x8' COPPER -CLAD DarE I GROUND ROD- 0.188 WALL BRACKET ALUM. ALLOY 6063 -T6 1/2" BNC LOCKBOLT GR. 18 -8 S.S. FLUSH JOINT 4 -1/2" O.D_ TAPERED ALUM. POLE 0.188 WALL ALLOY 6063 -T6 SATIN GROUND FINISH - TO LUMINAIRE 4' 3• SQ. OR DIA_ 1/4" MINIMUM jDRAIN HOLE TOP OF CONCRETE FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. METER BASE MAIN SIZE AS REQUIRED 20 }} 20A 4-1/2" L2" N.P.S. LIGHTING A O.D. SUPFITTER 5' 7�7 RADIUS t -1•_2" zoA LIGHTING B 20A LIGHTING C 30' -0" 23' -3" SHAFT GROUND BAR 151 HANDHOLE. 4 "x6" OPENING W /COVER AND S.S. SCREWS 8" O.D. BASE FLANGE ALLOY 356 -T6 WITH rGROUND UG BOLT COVERS & S.S. SCREWS 1' -6" -I I-- 11 -1/4" SQ. Z 11" TO 12" DIA. BOLT CIRCLE rn 4" CONCRETE PADV__C'_��FIINISHED GB OLE ABOVE of (4) 1" BNC GALV. STEEL ANCHOR BOLTS WITH NUTS AND WASHERS STANDARD 30 FOOT DAVIT POLE ADOPTED i� CtT1' aP R6NTON Standard pleas LST DATE: 2- Oct -87 j Z neTr Rflfl9flN Rv eooR DWG. NAME JR -02 SP PAGE: JO03 ® Ef7 0 0 10001 [xa �0 ° EPDXY FILL EPDXY FILL INLINE SPLICE WYE SPLICE SPLICE KIT � BQ DIAMETER 7/8" ••D LINE MGM= TO J1sa PHOTO CELL tl TEST SWITCH SOA 11 SIGNAL 20A LIGHT NG D 20A FUSE KIT FUSE KIT & SPLICE KIT DETAILS ADOPTED CITY OF RENTON ♦OO n. "aea pleas -( ISTDATE :11 /5/96 DWG: NAME:JR -12 SP PAGE:J013 NOTES: Ail dimensions are minimum. Exact configurations vary among different manufacturers. The noted lid thickeners overall minimums. The Diamond Pattern for Type 1 or Type 2 Boxes shall be 28% minimum of overall thickness. Lid support members shall be welded to the frame. 490OPSI concrete is allowed if box reinforcement consists of 6 X 6 - W3 X W3 welded wire fabric welded to the frame. When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12" deep extension boxes. When noted in the contract_ Type 2 Boxes shall be provided with a 10' X 27 1/2" 10 gage divider plate complete with fasteners. Non - concrete Boxes may be submitted for approval. Evaluation will include an H -20 Load Test. JUNCTION BOX DIMENSION TABLE I C I 1 ARK ITEM TYPICAL TYPE 2 LIGHTING 22" UNDERGROUND 33" SYSTEM 17" ADOPTED CITY OF RENTON j 3tenderd plena LST DATE: 12/96 DWG. NAME:JR -O6 SP PAGE: J007 METER BASE MAIN SIZE AS REQUIRED 20 }} 20A 4-1/2" L2" N.P.S. LIGHTING A O.D. SUPFITTER 5' 7�7 RADIUS t -1•_2" zoA LIGHTING B 20A LIGHTING C 30' -0" 23' -3" SHAFT GROUND BAR 151 HANDHOLE. 4 "x6" OPENING W /COVER AND S.S. SCREWS 8" O.D. BASE FLANGE ALLOY 356 -T6 WITH rGROUND UG BOLT COVERS & S.S. SCREWS 1' -6" -I I-- 11 -1/4" SQ. Z 11" TO 12" DIA. BOLT CIRCLE rn 4" CONCRETE PADV__C'_��FIINISHED GB OLE ABOVE of (4) 1" BNC GALV. STEEL ANCHOR BOLTS WITH NUTS AND WASHERS STANDARD 30 FOOT DAVIT POLE ADOPTED i� CtT1' aP R6NTON Standard pleas LST DATE: 2- Oct -87 j Z neTr Rflfl9flN Rv eooR DWG. NAME JR -02 SP PAGE: JO03 ® Ef7 0 0 10001 [xa �0 ° EPDXY FILL EPDXY FILL INLINE SPLICE WYE SPLICE SPLICE KIT � BQ DIAMETER 7/8" ••D LINE MGM= TO J1sa PHOTO CELL tl TEST SWITCH SOA 11 SIGNAL 20A LIGHT NG D 20A FUSE KIT FUSE KIT & SPLICE KIT DETAILS ADOPTED CITY OF RENTON ♦OO n. "aea pleas -( ISTDATE :11 /5/96 DWG: NAME:JR -12 SP PAGE:J013 NOTES: Ail dimensions are minimum. Exact configurations vary among different manufacturers. The noted lid thickeners overall minimums. The Diamond Pattern for Type 1 or Type 2 Boxes shall be 28% minimum of overall thickness. Lid support members shall be welded to the frame. 490OPSI concrete is allowed if box reinforcement consists of 6 X 6 - W3 X W3 welded wire fabric welded to the frame. When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12" deep extension boxes. When noted in the contract_ Type 2 Boxes shall be provided with a 10' X 27 1/2" 10 gage divider plate complete with fasteners. Non - concrete Boxes may be submitted for approval. Evaluation will include an H -20 Load Test. JUNCTION BOX DIMENSION TABLE I C I 1 ARK ITEM BOX TYPE TYPE 1 ALTtR1ATE A ALTERNATE B TYPE 2 A Box Outside length 22" 22" 33" B Box Outside Width 17" 17" 22 1/2- C Box Inside Length 18" 19" 28" Box Inside Width 13" 14" 17" E Lid Length 18" 18" 26 1/2- Lid Width 13" 13" 17" G Box Depth 12" 12" 12" & H Lid Frame Depth *GALVANIZED STEEL 5/16" 5/16" Will Thickness Min. _5/16" 1 1/2" 1 1:2- 1 1/2" Wire Reinforcement IN W -2.5 W -2.5 Le end See Deta6 See Deta7 See Detall NOTES: ELEVAnON VIEW 49. 225 AMP COPPER BUSSING 18 PLC PANNEL ITEM Box MATERIALS 6000 PSI concrete See Notes 51. C.H. 2P 20 AMP BREAKER (BAB2020) • Frame Diamond Plate Steel - A786 I 53. C.H. 1P 20 AMP BREAKER (BAB1020) z• r t Ud Su ort 1 IYMiL Thick Steel C, L or L - A36 MEETS EUSERC REQUIREMENTS TG-RAnVEL • Lid Diamond Plate Steel - A786 58. SQUARE D LIGHTING CONTACTOR TACOMA POWER (981ODPA32VO2UI) Anchors Steel Wire or Tee Plate Reinforcement I ASTM A -82 Steel 66. SQUARE D TERMINAL BLOCK *GALVANIZED STEEL TYPICAL ,MNCTON BOX INSTALLATION DETAILS LEGEND DETAIL (Mnk L) Il�-I M TYPE T BOX SIGNALS T 0 TYPE 'II' BOX LIGHTING ° ° ° ^° �° TS -LT Noac DETaa PLAN SYMBOLS (a eumrael RA TELEMETRY TRAFFIC SIGNAL SYSTEM LEGEND JUNCTION BOX DETAILS -Form Letters with 1/8- weld L T-11 CITY F�RENTON Bead Grind off Diamond Pattem before fannfrrg + Standard plans ILLUMINATION SYSTEM LEGEND 1 LST DATE :1 1 /89 DWG. NAME: JR -36 SP PAGE: J01 NOTES: 49. 225 AMP COPPER BUSSING 18 PLC PANNEL 50. C.H. 2P 100 AMP MAIN (BAB2100) 51. C.H. 2P 20 AMP BREAKER (BAB2020) CONTRACTOR IS RESPONSIBLE TO F G 52. C.H. 1P 50 AMP BREAKER (BAB1050) VERIFY METER ARRANGEMENT I 53. C.H. 1P 20 AMP BREAKER (BAB1020) 54. C.H. 1P 15 AMP BREAKER (BAB1015) 55. MILBANK METER ENCLOSURE (MS- 24 -TB) MEETS EUSERC REQUIREMENTS 56. HUBBELL SWITCH (CS1201 -1) APPROVED BY: 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898 -1) PUGET SOUND ENERGY 58. SQUARE D LIGHTING CONTACTOR TACOMA POWER (981ODPA32VO2UI) 61. SOUTHCO DOOR S.S. HINGE (F6 -3 -1) 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2 -626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1 "X.25" GASKET BY: NORTHWArsT fAEA TRAFT -IC EX)=M7T0 10104 -111 th Ave. N.E., Kirkland, WA 98033 Phone: 425.522.4118 Fax: 425.522.4311 J -11 TYPE 1 AND 2 HANDHOLE LOCKING DEVICE 3/8" X 2" LONG PIN HEX 1/2" DIAM. HOLES SECURITY SCREW S.S. (TYP,) COUNTERSUNK 14" X 19" AND 17" X 28" GALVANIZED HANDHOLE LID DRILL THREAD FOR 3/8' DIAM. BOLTS GALVANIZED STEEL BAR 1" WIDE, 1/2" THICK RECOMMENDED FOR APPROVAL BY BY BY CHECKED FOR COMPLIANCE TO CITY STANDARDS _ DATE DATE DATE NOTES: 49. 225 AMP COPPER BUSSING 18 PLCS PANNEL 50. C.H. 2P 100 AMP MAIN (BAB2100) 51. C.H. 2P 20 AMP BREAKER (BAB2020) 52. C.H. 1P 50 AMP BREAKER (BAE1050) 53. C.H. 1P 20 AMP BREAKER (BAB1020) 54. C.H. 1P 15 AMP BREAKER (BAB1015) 55. MILBANK METER ENCLOSURE (MS- 24 -TB) 56. HUBBELL SWITCH (CS1201 -1) 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898 -1) 58. SQUARE D LIGHTING CONTACTOR (981ODPA32VO2U1) 61. SOUTHCO DOOR S.S. HINGE (F6 -3 -1) o W 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2 -626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1 "X.25" GASKET CONTRACTOR IS RESPONSIBLE TO m VERIFY. METER ARRANGEMENT O MEETS. EUSERC REQUIREMENTS APPROVFD'BY: PUGET SOUND ENERGY TACOMA POWER 0 0 qo E 0 . °r 6.00-- ' r• TYP 16 n[ 0e • k:U I WV, �6Y s r7 EQOp ME FR_