Loading...
HomeMy WebLinkAboutT-338507i Q O v o ° w � m r ° w A Q a a j � J 0 Q W Z }� O J Cl) Z_ z g � J J a° �o o.. I 0 O o� 3v a ~ LtJ as � D U \c E c c E m OE N c R c 00 a� s g� 12 z 0 N w 0_ zz 0.188 WALL BRACKET ALUM. ALLOY 6063 -T6 1/2" BNC LOCKBOLT GR. 18 -8 S.S. FLUSH JOINT 4 -1/2" O.D. TAPERED ALUM. POLE SIZE AS REQUIRED - I ` 8 ,X4-1/2'11 L2" N.P.S. O.D. SLIPFITTER 5'-9" RADIUS 0.188 WALL ALLOY 6063 -T6 18, -3" SATIN GROUND FINISH 23' -3" 28'-3" 33' -3" SHAFT -20 25' -0" 30' -0" 35' -0" 40' -0" 151 HANDHOLE. 4"x6" OPENING W /COVER AND S.S. SCREWS 8" O.D. BASE FLANGE ALLOY 356 -T6 WITH r GROUND UG BOLT COVERS & S.S. SCREWS -I - 11 -1/4° SQ. 11" TO 12" DIA. BOLT CIRCLE 4 1/2° OF BOLT ABOVE 4" CONCRETE PAL FINISHED GRADE (4) 1" BNC GALV. STEEL ANCHOR BOLTS WITH 4' NUTS AND WASHERS 4 STANDARD 25 -40 FOOT DAVIT POLE ADOPTED CITY OF RENTON ♦ °/ 4 Standard plans NZ LST DATE: 10/30/96 ann¢inry av APPR DWG. NAME: JR -01 SP PAGE: J002 FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS - S.E.C. OR EQUAL — TYPICAL DESIGN '$Ba JUNCTION BOX SPLICE KITS GROUND LUC CLEAR EPDXY SPLICE KITS ON ALL THRU 2" MIN. GROUT WIRE RUNS UNDER POLE 4" CONCRETE BASE - PAD 5» 9„ 1111= =11118 -f11 °° ° >= III = III =11° #8 GREEN : =UI =1111 °1111 =111 GROUND WIRE Ipl= t. GROUND CLAMP 2- (SIZED AS REQ'D) PVC CONDUIT LIGHTING SYSTEM SYSTEM WIRES TO CONTACTOR CONCRETE 5/8 "x8' FOUNDATION - COPPER -CLAD GROUND ROD TO LUMINAIRE 1/4" MINIMUM ,-DRAIN HOLE 1 25' 1 30' 35' 4' SL 3' nR SQ. MA 8' -3" 23' -3" 28' -3" im T ill 0.188 0.219 0.219 Im OWN z 0 N w 0_ zz 0.188 WALL BRACKET ALUM. ALLOY 6063 -T6 1/2" BNC LOCKBOLT GR. 18 -8 S.S. FLUSH JOINT 4 -1/2" O.D. TAPERED ALUM. POLE SIZE AS REQUIRED - I ` 8 ,X4-1/2'11 L2" N.P.S. O.D. SLIPFITTER 5'-9" RADIUS 0.188 WALL ALLOY 6063 -T6 18, -3" SATIN GROUND FINISH 23' -3" 28'-3" 33' -3" SHAFT -20 25' -0" 30' -0" 35' -0" 40' -0" 151 HANDHOLE. 4"x6" OPENING W /COVER AND S.S. SCREWS 8" O.D. BASE FLANGE ALLOY 356 -T6 WITH r GROUND UG BOLT COVERS & S.S. SCREWS -I - 11 -1/4° SQ. 11" TO 12" DIA. BOLT CIRCLE 4 1/2° OF BOLT ABOVE 4" CONCRETE PAL FINISHED GRADE (4) 1" BNC GALV. STEEL ANCHOR BOLTS WITH 4' NUTS AND WASHERS 4 STANDARD 25 -40 FOOT DAVIT POLE ADOPTED CITY OF RENTON ♦ °/ 4 Standard plans NZ LST DATE: 10/30/96 ann¢inry av APPR DWG. NAME: JR -01 SP PAGE: J002 FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS - S.E.C. OR EQUAL — TYPICAL DESIGN '$Ba JUNCTION BOX SPLICE KITS GROUND LUC CLEAR EPDXY SPLICE KITS ON ALL THRU 2" MIN. GROUT WIRE RUNS UNDER POLE 4" CONCRETE BASE - PAD 5» 9„ 1111= =11118 -f11 °° ° >= III = III =11° #8 GREEN : =UI =1111 °1111 =111 GROUND WIRE Ipl= t. GROUND CLAMP 2- (SIZED AS REQ'D) PVC CONDUIT LIGHTING SYSTEM SYSTEM WIRES TO CONTACTOR CONCRETE 5/8 "x8' FOUNDATION - COPPER -CLAD GROUND ROD TO LUMINAIRE 1/4" MINIMUM ,-DRAIN HOLE TYPICAL LIGHTING UNDERGROUND SYSTEM Gv ADOPTED CITY OF RENTON ♦ �► Standard pleas LST DATE: 12/96 DWG. NAME: JR -06 SP PAGE:J007 1 25' 1 30' 35' 4' SL 3' nR SQ. MA 8' -3" 23' -3" TYPICAL LIGHTING UNDERGROUND SYSTEM Gv ADOPTED CITY OF RENTON ♦ �► Standard pleas LST DATE: 12/96 DWG. NAME: JR -06 SP PAGE:J007 R/W LINE SIDEWALK CURB CROADWAY CURB SIDEWALK R/W LINE 10' MIN, CLEARANCE FROM DRIVEWAI' ALTERNATE PLAN VIEW H 1 25' 1 30' 35' 40' SL 8' -3" 23' -3" 28' -3" im T ill 0.188 0.219 0.219 Im R/W LINE SIDEWALK CURB CROADWAY CURB SIDEWALK R/W LINE 10' MIN, CLEARANCE FROM DRIVEWAI' ALTERNATE PLAN VIEW H 1 25' 1 30' 35' 40' SL 8' -3" 23' -3" 28' -3" 33' -3" T 0.188 0.188 0.219 0.219 ,-TAPERED ALUM. POLE T' WALL ALLOY 6063 -T6 SATIN GROUND FINISH HANDHOLE 4 "x6" OPENING W /COVER & S.S. SCREWS. GROUND LUG INSIDE POLE f 1' -6" 1' -2" 2' TO 4' OVERHANG 'H' J° ° 0 ; STREET LIGHT CONDUIT TRENCH DEPTH 24" ALTERNATE STREET CROSS SECTION 2" N.P.S. SLIPFITTER SINGLE OR DOUBLE MAST ARM AS P"' 10' UTILITY EASEMENT R/W 1 10 1' -2 2' VERHANG 'H' 6.5' SL / FACE OF CU B TO CENTER OF F 0 LE STREET LIGHT CONDUIT - TRENCH DEPTH 24" TYPICAL STREET LIGHT ROMEX ECTOR LOCKNUT DOUBLE MAST ARM, INSTALL 2ND CABLE BETWEEN LUMINAIRES WHEN BOTH LUMINAIRES ARE ON SAME CIRCUIT MAST ARM WIRING DETAIL FOUNDATION LOCATION STRAIN RELIEF DETAIL Y ADOPTED CITY OF RENTON Standard plans NSD LST DATE: 10/30/96 DWG. NAME: JR -05 SP PAGE: J006 (INTERIOR PLAT STREETS) SOFEET G HEIGHT R/W 7.5' -2� 2' TO 4' OVERHANG 'H' 4.5' 'SL' FACE OF CU B TO CENTER OF OLE STREET LIGHT CONDUIT) TRENCH DEPTH 24" TYPICAL STREET LIGHT FOUNDATION LOCATION (HOQUTAM AVE. N.E.) (MODIFIED) LIGHT BASE AND JUNCTION BOX LOCATIONS ADOPTED CITY OF RENTON ♦ �!�/ Standard plans P NTO LST DATE: 12/96 DWG. NAME: JR -35 SP PAGE: J014 INSTALL DECAL NUMBERS VERTICALLY. INSTALL IN DRY WEATHER 50 P OR ABOVE. NUMBERING EXAMPLES TRAFFIC FLOW PLAN VIEW DECAL: RELECTORIZED GOTHIC GOLD OR WHITE LEGEND ON BLACK BACKGROUND WER 13/4 » -2,. 2 " -2l' 2N' -3 if STREET LIGHT STANDARD DECAL NUMBERING SYSTEM V ADOPTED CITY OF RENTON Standard plans N"10 LST DATE: 12/96 DWG. NAME: JR -09A SP PAGE: J009 �(3'T 333587 JAN -23 -2007 17.26 CITY S RENTON 425 430 7231 P. 01`01 , F� r TITE INCORPORATED t`5 -11 ryXe 1 9nd 0� H4nd /70 /e xOff%' Jr r ' q° OIA. h4WS --- 1 '9.5 ^LONs AND COUNTERSINK n to EeG AMY ' SCm�u �y� IY"x28" C%CIDN+719 1 I NRvDNOtf LID 1 > DRILL rUREAD FOR t GA'LVANIZEO 5rt.ITL BAR W DIA. BOLTS, r° WIDE TRICK TOTRL P.01 RECOMMENDED FOR APPROVAL BY Ar. Q DATE 5/6/8 BY DATE BY DATE RECORD�� DOCUMENT BY K�D�t/ (/u- 1 DATE 2 -E -2 H I C HERMAN TRAFFIC ENGINEERING 15324 Southeast 133rd Court, Renton, Washington 98059 425- 277 -1740 tel. 425- 277 -5718 fax hte @comcast.net aD . I - ,5%S03 adUi9 � e'suu�