0.188 WALL BRACKET
ALUM. ALLOY 6063 -T6
1/2" BNC LOCKBOLT
GR. 18 -8 S.S.
FLUSH JOINT
4 -1/2" O.D.
TAPERED ALUM. POLE
SIZE AS
REQUIRED -
I ` 8
,X4-1/2'11 L2" N.P.S.
O.D. SLIPFITTER
5'-9" RADIUS
0.188 WALL ALLOY 6063 -T6 18, -3"
SATIN GROUND FINISH 23' -3"
28'-3"
33' -3"
SHAFT
-20
25' -0"
30' -0"
35' -0"
40' -0"
151 HANDHOLE. 4"x6" OPENING
W /COVER AND S.S. SCREWS 8" O.D.
BASE FLANGE ALLOY 356 -T6 WITH r GROUND UG
BOLT COVERS & S.S. SCREWS
-I - 11 -1/4° SQ.
11" TO 12" DIA.
BOLT CIRCLE 4 1/2° OF BOLT ABOVE
4" CONCRETE PAL FINISHED GRADE
(4) 1" BNC GALV. STEEL
ANCHOR BOLTS WITH 4'
NUTS AND WASHERS 4
STANDARD 25 -40 FOOT DAVIT POLE
ADOPTED
CITY OF RENTON
♦ °/ 4
Standard plans
NZ LST DATE: 10/30/96
ann¢inry av APPR DWG. NAME: JR -01 SP PAGE: J002
FUSE KITS
QUICK DISCONNECT
10 AMP IN LINE FUSE
KITS - S.E.C. OR EQUAL —
TYPICAL DESIGN '$Ba
JUNCTION BOX
SPLICE KITS GROUND LUC
CLEAR EPDXY SPLICE
KITS ON ALL THRU 2" MIN. GROUT
WIRE RUNS UNDER POLE
4" CONCRETE BASE -
PAD
5» 9„
1111=
=11118 -f11 °° ° >= III = III =11°
#8 GREEN : =UI =1111 °1111 =111
GROUND WIRE Ipl=
t.
GROUND
CLAMP
2- (SIZED AS REQ'D) PVC CONDUIT
LIGHTING SYSTEM SYSTEM
WIRES TO CONTACTOR
CONCRETE
5/8 "x8' FOUNDATION -
COPPER -CLAD
GROUND ROD
TO LUMINAIRE
1/4" MINIMUM
,-DRAIN HOLE
1 25' 1
30'
35'
4'
SL
3'
nR
SQ.
MA
8' -3"
23' -3"
28' -3"
im
T
ill
0.188
0.219
0.219
Im
OWN
z
0
N
w
0_
zz
0.188 WALL BRACKET
ALUM. ALLOY 6063 -T6
1/2" BNC LOCKBOLT
GR. 18 -8 S.S.
FLUSH JOINT
4 -1/2" O.D.
TAPERED ALUM. POLE
SIZE AS
REQUIRED -
I ` 8
,X4-1/2'11 L2" N.P.S.
O.D. SLIPFITTER
5'-9" RADIUS
0.188 WALL ALLOY 6063 -T6 18, -3"
SATIN GROUND FINISH 23' -3"
28'-3"
33' -3"
SHAFT
-20
25' -0"
30' -0"
35' -0"
40' -0"
151 HANDHOLE. 4"x6" OPENING
W /COVER AND S.S. SCREWS 8" O.D.
BASE FLANGE ALLOY 356 -T6 WITH r GROUND UG
BOLT COVERS & S.S. SCREWS
-I - 11 -1/4° SQ.
11" TO 12" DIA.
BOLT CIRCLE 4 1/2° OF BOLT ABOVE
4" CONCRETE PAL FINISHED GRADE
(4) 1" BNC GALV. STEEL
ANCHOR BOLTS WITH 4'
NUTS AND WASHERS 4
STANDARD 25 -40 FOOT DAVIT POLE
ADOPTED
CITY OF RENTON
♦ °/ 4
Standard plans
NZ LST DATE: 10/30/96
ann¢inry av APPR DWG. NAME: JR -01 SP PAGE: J002
FUSE KITS
QUICK DISCONNECT
10 AMP IN LINE FUSE
KITS - S.E.C. OR EQUAL —
TYPICAL DESIGN '$Ba
JUNCTION BOX
SPLICE KITS GROUND LUC
CLEAR EPDXY SPLICE
KITS ON ALL THRU 2" MIN. GROUT
WIRE RUNS UNDER POLE
4" CONCRETE BASE -
PAD
5» 9„
1111=
=11118 -f11 °° ° >= III = III =11°
#8 GREEN : =UI =1111 °1111 =111
GROUND WIRE Ipl=
t.
GROUND
CLAMP
2- (SIZED AS REQ'D) PVC CONDUIT
LIGHTING SYSTEM SYSTEM
WIRES TO CONTACTOR
CONCRETE
5/8 "x8' FOUNDATION -
COPPER -CLAD
GROUND ROD
TO LUMINAIRE
1/4" MINIMUM
,-DRAIN HOLE
TYPICAL LIGHTING UNDERGROUND SYSTEM
Gv ADOPTED
CITY OF RENTON
♦ �►
Standard pleas
LST DATE: 12/96
DWG. NAME: JR -06 SP PAGE:J007
1 25' 1
30'
35'
4'
SL
3'
nR
SQ.
MA
8' -3"
23' -3"
TYPICAL LIGHTING UNDERGROUND SYSTEM
Gv ADOPTED
CITY OF RENTON
♦ �►
Standard pleas
LST DATE: 12/96
DWG. NAME: JR -06 SP PAGE:J007
R/W LINE
SIDEWALK
CURB
CROADWAY
CURB
SIDEWALK
R/W LINE
10' MIN,
CLEARANCE FROM DRIVEWAI'
ALTERNATE PLAN VIEW
H
1 25' 1
30'
35'
40'
SL
8' -3"
23' -3"
28' -3"
im
T
ill
0.188
0.219
0.219
Im
R/W LINE
SIDEWALK
CURB
CROADWAY
CURB
SIDEWALK
R/W LINE
10' MIN,
CLEARANCE FROM DRIVEWAI'
ALTERNATE PLAN VIEW
H
1 25' 1
30'
35'
40'
SL
8' -3"
23' -3"
28' -3"
33' -3"
T
0.188
0.188
0.219
0.219
,-TAPERED ALUM. POLE
T' WALL ALLOY 6063 -T6
SATIN GROUND FINISH
HANDHOLE 4 "x6"
OPENING W /COVER
& S.S. SCREWS.
GROUND LUG
INSIDE POLE
f 1' -6"
1' -2"
2' TO 4'
OVERHANG
'H'
J° ° 0 ;
STREET LIGHT
CONDUIT TRENCH DEPTH 24"
ALTERNATE STREET CROSS SECTION
2" N.P.S. SLIPFITTER
SINGLE OR DOUBLE MAST
ARM AS P"'
10' UTILITY EASEMENT
R/W
1 10
1' -2
2' VERHANG
'H' 6.5'
SL
/
FACE OF CU B TO
CENTER OF F 0 LE
STREET LIGHT CONDUIT -
TRENCH DEPTH 24"
TYPICAL STREET LIGHT
ROMEX
ECTOR
LOCKNUT
DOUBLE MAST ARM, INSTALL 2ND CABLE
BETWEEN LUMINAIRES WHEN BOTH LUMINAIRES
ARE ON SAME CIRCUIT
MAST ARM WIRING DETAIL
FOUNDATION LOCATION
STRAIN RELIEF DETAIL
Y ADOPTED
CITY OF RENTON
Standard plans
NSD LST DATE: 10/30/96
DWG. NAME: JR -05 SP PAGE: J006
(INTERIOR PLAT STREETS)
SOFEET G
HEIGHT
R/W
7.5'
-2�
2' TO 4'
OVERHANG
'H' 4.5'
'SL'
FACE OF CU B TO
CENTER OF OLE
STREET LIGHT CONDUIT)
TRENCH DEPTH 24"
TYPICAL STREET LIGHT
FOUNDATION LOCATION
(HOQUTAM AVE. N.E.)
(MODIFIED)
LIGHT BASE AND JUNCTION BOX LOCATIONS
ADOPTED
CITY OF RENTON
♦ �!�/
Standard plans
P NTO LST DATE: 12/96
DWG. NAME: JR -35 SP PAGE: J014
INSTALL DECAL NUMBERS
VERTICALLY. INSTALL
IN DRY WEATHER 50 P
OR ABOVE.
NUMBERING EXAMPLES
TRAFFIC
FLOW
PLAN VIEW
DECAL:
RELECTORIZED
GOTHIC GOLD
OR WHITE LEGEND
ON BLACK
BACKGROUND
WER
13/4 » -2,.
2 " -2l' 2N' -3
if
STREET LIGHT STANDARD
DECAL NUMBERING SYSTEM
V ADOPTED
CITY OF RENTON
Standard plans
N"10 LST DATE: 12/96
DWG. NAME: JR -09A SP PAGE: J009
�(3'T 333587
JAN -23 -2007 17.26 CITY S RENTON 425 430 7231 P. 01`01
,
F�
r TITE
INCORPORATED t`5 -11 ryXe 1 9nd 0� H4nd /70 /e xOff%' Jr
r '
q° OIA. h4WS --- 1 '9.5 ^LONs
AND COUNTERSINK n to EeG AMY
' SCm�u �y�
IY"x28" C%CIDN+719
1 I NRvDNOtf LID
1 >
DRILL rUREAD FOR t GA'LVANIZEO 5rt.ITL BAR
W DIA. BOLTS, r° WIDE
TRICK
TOTRL P.01
RECOMMENDED FOR APPROVAL
BY Ar. Q DATE 5/6/8
BY DATE
BY DATE
RECORD�� DOCUMENT
BY K�D�t/ (/u- 1 DATE 2 -E -2
H I C HERMAN TRAFFIC ENGINEERING
15324 Southeast 133rd Court, Renton, Washington 98059
425- 277 -1740 tel. 425- 277 -5718 fax hte @comcast.net
aD . I - ,5%S03
adUi9 � e'suu�