HomeMy WebLinkAboutT-346405L22
OH off
AS —BUILT NOTES
w
w
ASpH
au
L21 �)
U LOCATION OF THE UNDERGROUND CONDUIT BUNDLE INSTALLED BY 360 NETWORKS.
TWO OF THESE CONDUITS ARE THE PROPERTY OF CITY OF RENTON. THE TYPICAL
DEPTH OF THE CONDUIT BUNDLE IS 42 INCHES TO 48 INCHES.
BB WHERE THE TRENCH FOR THE NEW SIGNAL CONDUIT INTERCEPTS THE ROUTE OF
THE 360 CONDUIT BUNDLE, LOCATE THE CITY OF RENTON CONDUIT, REMOVE A
SEGMENT OF EACH CONDUIT AND INSTALL 2 INCH SCHEDULE 80 PVC CONDUIT
INTERCONNECTING THE EXISTING CONDUIT TO THE ADJACENT, NEW HAND HOLE.
USE CONDUIT SWEEPS WITH A MINIMUM RADIUS OF 24 INCHES.
C REPLACE THIS TYPE 3 JUNCTION BOX WITH A 25 —TA VAULT TO PROVIDE ROOM TO
SPLICE FIBER INTO THE SIGNAL CABINET.
INCREASE THE SIZE OF THE SPARE 2 INCH CONDUIT TO 3 INCHES. INSTALL
DD L
CABLE PULL.
OADD A 3 INCH SCHEDULE 80 PVC SPARE CONDUIT TO THIS CONDUIT SEGMENT.
INSTALL A CABLE PULL.
IF ADD A 2 INCH SCHEDULE 80 PVC CONDUIT TO THE ADVANCE LOOP DETECTION
CONDUIT TRENCH. INCLUDE A SIDE TRENCH APPROXIMATELY 5 FEET IN LENGTH
TO THE BASE OF THE NEW PSE POLE LOCATION AND SWEEP THE NEW CONDUIT
TO THE BASE OF THE POLE.
OG PROVIDE A NEW POLE RISER TO WITHIN 3 FEET OF THE EXISTING CITY OF RENTON
AERIAL FIBER OPTIC CABLE RUN. INSTALL CABLE PULL.
DISPLAY NOTES SIGNAL HEAD DISPLAY
1. ALL VEHICLE SIGNAL HEADS O
SHALL BE CONVENTIONAL ® O 12" O 12"
ALUMINUM TYPE WITH 12"
L.E.D. DISPLAYS AND BE
EQUIPPED WITH TUNNEL VISORS . 12" . 12"
AND ATES AND TYPE M
MOUNTS TS PER PER WSDOT STD. PLAN O 12" G
NOTE 12"
UNLESS OTHERWISE
NOTED. PEDESTRIAN HEAD
28, 29, 48, 49 .....— 12"
21, 22, 23,
2. ALL PEDESTRIAN HEADS SHALL 62, 41, 42 vac BI —MODAL
BE L.E.D. TYPE AND SHALL
HAVE "Z" CRATE VISORS. 61/11
SIGN SCHEDULE
0o
g NOTE: MOUNT SIGNS PER WSDOT STD. PLAN G- 30.10 -00.
b O
O O
M� T IBLVD bOQ�IAM AVE NE
D3 -301
D3 -301
70" X 12"
70" X 12" R9 -3B R
18" X 12"
f!
�DREg/
PROJECT ENGINEER: KIRK HARRIS
USED
i
OV .WA
DESIGNED BY: SLPO
NOT
$
'"
DRAWN BY: OXA
E
L
USED
9
N 34403
�0 88otBT��
CHECKED BY: KAHA
4.
�BgJONAL ��
DATE PLATTED: 11/02/09
[FI19 TTTS01RENT00000010.dwg
@
II.05.04k
0
SHEET
TS03 FOR
SIGNAL POLE SPECIFICATIONS.
LEFT TURN
YIELD
ON GREEN
R10 -12
24" X 30"
10 -6 -091 RECORD DRAWINGS
DATE I REVISIONS
0
V21
\x
8
O�
PHASE DIAGRAM L
m
f %Y]
m
H1
m
RE
--- PEDESTRIAN MOVEMENT
(PROTECTED)
VEHICULAR MOVEMENT
(PROTECTED)
VEHICULAR THROUGH (PROTECTED)
AND LEFT TURN (PERMISSIVE)
MOVEMENT
VEHICULAR THROUGH (PROTECTED)
AND LEFT TURN (PROTECTED)
MOVEMENT
KAHA
APPRVD. '
02�
0 ,0 20 40
O
�r
+
O
RE
GENERAL NOTES
1.
NOT
r�
USED
LEGEND.
2.
NOT
NOT
USED
USED
3.
NOT
SHEET
USED
m
RE
--- PEDESTRIAN MOVEMENT
(PROTECTED)
VEHICULAR MOVEMENT
(PROTECTED)
VEHICULAR THROUGH (PROTECTED)
AND LEFT TURN (PERMISSIVE)
MOVEMENT
VEHICULAR THROUGH (PROTECTED)
AND LEFT TURN (PROTECTED)
MOVEMENT
KAHA
APPRVD. '
02�
0 ,0 20 40
O
�r
+
O
RE
GENERAL NOTES
1.
SEE
SHEET
LGO1 FOR
LEGEND.
2.
SEE
SHEET
RD01 FOR
ROADWAY PREPARATION PLAN
3.
SEE
SHEET
RD02 (ROADWAY PLAN) FOR CHANNELIZATION
AND
ROADWAY NOTES.
4.
SEE
SHEET
TS02 FOR
WIRING DIAGRAM & SCHEDULE.
5.
SEE
SHEET
TS03 FOR
SIGNAL POLE SPECIFICATIONS.
6.
SEE
SHEET
TSO4 FOR
TRAFFIC SIGNAL DETAILS.
7.
ALL
JUNCTION BOXES
SHALL HAVE LOCKING LIDS PER
THE
DETAIL
ON SHEET
TSO4.
I
t
oo/
Y i
p �
INN
�W
,I �)V 1 ,
II
i
o
1
6
ITYI
I
OJ
wl,
ADO
F
G
Vt
NMI!
P01 AREA DETAIL
SCALE 1 ":10'
o°
\ �J
\
H
1
\
RECORD DRAWING
INFORMATION SHOWN ON RECORD DRAWINGS FOR
LOCATIONS AND ELEVATIONS OF FEATURES WERE
PROVIDIT_D BY THE CITY OF RENTON AND /OR ITS
CONSTRUCTION CONTRACTOR. DAVID EVANS AND
ASSOCIATES INC. ASSUMES NO LIABILITY FOR THE
ACCURACY OF THIS INFORMATION
TRAFFIC SIGNAL NOTES
OCONSTRUCT FOUNDATION PER DETAIL ON SHEET TS03. PROVIDE SPECIAL
DESIGN (DOUBLE MAST ARM) TYPE III SIGNAL STANDARD WITH 25 FT. AND 20
FT. MAST ARMS. INSTALL FOUR SIGNAL. HEADS, ONE TENNON FOR FUTURE
SIGNAL HEAD, THREE E.V.P. DETECTORS, TWO EVPE CONFIRMATION LIGHTS,
ONE TERMINAL CABINET, ONE STREET LIGHT AND THREE SIGNS ALL PER
WSDOT STD. PLANS AS AMENDED BY THE SPECIAL PROVISIONS.
O CONSTRUCT FOUNDATION PER WSDOT ST PLAN J -7A. PROVIDE TYPE 1 SIGNAL
STANDARD WITH ONE PED HEAD, AND ONE PED PUSH — BUTTON ALL PER
WSDOT STD. PLANS AS AMENDED BY Th E SPECIAL PROVISIONS.
O3 CONSTRUCT FOUNDATION PER DETAIL Oil SHEET TS03. PROVIDE TYPE III
SIGNAL STANDARD, WITH ONE SIGNAL HEAD, TWO PED PUSH BUTTONS, ONE
STREET LIGHT AND 41 FT MAST ARM WITH TWO SIGNAL HEADS, TWO PED
HEADS, TWO PED PUSH BUTTONS, ONE �EVPE CONFIRMATION LIGHT, ONE
TERMINAL CABINET, AND ONE SIGN ALL !PER WSDOT STD. PLANS AS AMENDED
BY THE SPECIAL PROVISIONS.
O4 CONSTRUCT FOUNDATION PER WSDOT ST PLAN J -7A. PROVIDE TYPE 1 SIGNAL
STANDARD WITH ONE PED HEAD, AND ONE PED PUSH — BUTTON ALL PER
WSDOT STD. PLANS AS AMENDED BY THE SPECIAL PROVISIONS.
O PROVIDE CONTROLLER, SERVICE AND BEES CABINETS ON CONCRETE
FOUNDATION PER DETAIL ON SHEET TS04 AND WSDOT STD. PLANS.
O6 PROVIDE TYPE 3 INDUCTION LOOP PER - 'WSDOT STD. PLAN J -8c.
O7 MOUNT VEHICLE SIGNAL HEAD 21 WITH 'TYPE K MOUNT PER WSDOT STD. PLAN
J -6f.
OS MOUNT PEDESTRIAN SIGNAL HEADS 29 AND 49 WITH TYPE D MOUNT PER
WSDOT STD. PLAN J -6f.
O9 MOUNT PEDESTRIAN SIGNAL HEADS 28 AND 48 WITH TYPE E MOUNT PER
WSDOT STD. PLAN J -6f.
10 PROVIDE RISER WITH 20 FEET OF SCHEDULE 40 PVC ABOVE 20 FEET OF
SCHEDULE 80 PVC PER PSE REQUIRMENTS. LEAVE SUFFICIENT WIRE COILED
FOR CONNECTION TO TRANSFORMER BY:OTHERS.
11 VIDEO DETECTION SYSTEM COMPONENTS'' PROVIDED BY OTHERS. LEAVE
SUFFICIENT LENGTH OF 6 —CDE CABLE(,) COILED IN BOTTOM OF CABINET OR
BELOW MAST ARM GROMMET FOR CONNECTION BY OTHERS.
12 EVPE DETECTOR ONLY. CONFIRMATION LIGHT MOUNTED SEPARATELY.
13 FOUNDATION SHAFT TO BE INSPECTED BY SOILS ENGINEER DURING
EXCAVATION. SEE SPECIAL PROVISIONS.
I \\ pH
CABINET PAD AREA DETAIL \\\
SCALE 1 ":10' \
PLANS PREPARED BY: RECORD DRAWING,
City of Renton' DAVID EVANS NE SUNSET BLVD (SR 900) AND HOQUU'
Department of Public Works o a AND SS1 CIATE mc. TRAFFIC SIGNAL
1055 S. Grady Way Q Bellevue Wei«, WOOS-3518
Phone, 425.519.6500
Renton, Washington 98057 TRAFFIC SIGNAL PLAN
AVE NE SHEET TS01
5 OF
8' f 346445;
,