HomeMy WebLinkAboutzT-3121Sets� N I ANIL :r. cew >1 r I V. O C n G. W a< N a r O 0 ao CITY OF RENTON (f) Z \ z U F- W o >� ° L 1 N 1:1 AVIE. S.W./ S .W. 70T H ST. 0 N�N Q W = i za �VjaUwo o Z 3 INTERSECTION IMPROVEMENT PROJECT ozZ I F- U W w a PROJECT NO. AC -STPH -1292 (001) /LA -4984 af a Q 0 DESCRIPTION a, v o� LL Z N �� 00 TS 1 gp .3:-u Q TRAFFIC SIGNAL WIRING DIAGRAM V_ Z .0 W �.� w d d TRAFFIC SIGNAL INTERCONNECT PLAN c :a E ao CITY OF RENTON (f) Z \ z U F- W o >� ° L 1 N 1:1 AVIE. S.W./ S .W. 70T H ST. 0 N�N Q W = i za �VjaUwo o Z 3 INTERSECTION IMPROVEMENT PROJECT ozZ I F- U W w a PROJECT NO. AC -STPH -1292 (001) /LA -4984 af a i •� d N W J } Q U Tx� f 0 0 -jL z z Q 0 DESCRIPTION a, v o� LL Z N �� 00 TS 1 TRAFFIC SIGNAL PLAN .3:-u Q TRAFFIC SIGNAL WIRING DIAGRAM V_ Z .0 W �.� w d d TRAFFIC SIGNAL INTERCONNECT PLAN c :a E a mE �E cf V C_ v(u a` ca i •� d N W J } Q U Tx� f 0 0 -jL z z W Q m 0 5 PROJECT LOCATI ❑N �# T3/2/O/ VICINITY MAP NOT TO SCALE OCTOBER 2003 Y ok \ N�/ REVIEWED FOR COMPLIANCE TO CITY STANDARDS: l-" L an TRANSPORTATION SYSTEMS DIRECTOR DATE MAINTENANCE SERVICES DIRECTOR DATE PLAN REVIEW DATE UTILITY SYSTEMS DIRECTOR DATE FIRE MARSHALL DATE .Yr ' i• MRAWING INLIEX SHEET NO. DESCRIPTION W X W X C1 PAVEMENT MARKING, TRAFFIC SIGNING AND INTERSECTION PLAN TS 1 TRAFFIC SIGNAL PLAN TS2 TRAFFIC SIGNAL WIRING DIAGRAM TS3 TRAFFIC SIGNAL POLE DETAILS TS4 TRAFFIC SIGNAL DETAILS TS5 TRAFFIC SIGNAL INTERCONNECT PLAN a Q W Q m 0 5 PROJECT LOCATI ❑N �# T3/2/O/ VICINITY MAP NOT TO SCALE OCTOBER 2003 Y ok \ N�/ REVIEWED FOR COMPLIANCE TO CITY STANDARDS: l-" L an TRANSPORTATION SYSTEMS DIRECTOR DATE MAINTENANCE SERVICES DIRECTOR DATE PLAN REVIEW DATE UTILITY SYSTEMS DIRECTOR DATE FIRE MARSHALL DATE .Yr ' i• MRAWING INLIEX SHEET NO. DESCRIPTION TITLE, DRAWING INDEX, AND VICINITY MAP C1 PAVEMENT MARKING, TRAFFIC SIGNING AND INTERSECTION PLAN TS 1 TRAFFIC SIGNAL PLAN TS2 TRAFFIC SIGNAL WIRING DIAGRAM TS3 TRAFFIC SIGNAL POLE DETAILS TS4 TRAFFIC SIGNAL DETAILS TS5 TRAFFIC SIGNAL INTERCONNECT PLAN ROLL 2.0.... � F IR 186 RECOMMENDED FOR APPROVAL • DATE DATE DATE DATE DATE '` 3 T': 3 I 4 � �U N 0 i Q •� o o o c� R4 -8 N N ~� 0)z �u z INSTALL 2' WIDE STRIP OF TRUNCATED DOME DETECTABLE I Z r a q � V) Q V) Z INSTALL NEW 20' WIDE DRIVEWAY FROM STA 6 +97 TO STA 7 +17 PER STANDARD Z 20 0 U o [� PER STANDARD PLAN F004 TO CREATE NEW OR MODIFIES LANDSCAPING ISLANDS. o ll � � •o0.)Q ck� z O (nQ •> p W .o Q ell e u �QCL a: (D z w ' V) Z cn %se' I) w V) ry ~ Li wU Q Z f Q Q � � N f H Z w Q � o CK W ri Q o CL i Q •� o o �r R4 -8 N N ~� INSTALL DOUBLE YELLOW CENTERLINE PER STANDARD PLAN �u z INSTALL 2' WIDE STRIP OF TRUNCATED DOME DETECTABLE WARNING PATTERN PER I• r 0 ao 19 l INSTALL NEW 20' WIDE DRIVEWAY FROM STA 6 +97 TO STA 7 +17 PER STANDARD Z 20 0 NOTCHES EVERY 6' PER STANDARD PLAN F004 TO CREATE NEW OR MODIFIES LANDSCAPING ISLANDS. d � a ° o •a •> p W .o Q ell e u � �w ' F- V) z cr a Q f -S E � co �. E N f H WIN �r � o ri i Q •� o w LEGEND �--� TRAFFIC SIGN O CONSTRUCTION NOTE CD SIGN INSTALLATION NOTE — — TEMPORARY CONSTRUCTION EASEMENT PROPERTY LINE 40 1 I in 11 2� PORTION OF NW 114 OF SEC. 19, T. 23 N., R. 05 E., W.M. - _ - 16 550 S.W. 7TH ST. 20 ( _ 15 I R/W S.W. 7TH ST. ,80I ( , .a 75 12 r7 - 4 ) - 12 LO 15 12 % 2 r I 7<% (z /i �0 20 I )° �fj �l 11 20 i '-_' -- _ITT J ....... N 10 14 1 13 0~� Salomon ..._ _... .. . , 1 4' 9+50 80+00 MN r + O CV / / ---- 5 YO •�� 21 6 o 20 12 500 S.W. 7TH ST. _ N m I R W U 10 —U5 10+50 11+00 11 + 50 - 12 +00 112 4 �n o �r R4 -8 N N ~� INSTALL DOUBLE YELLOW CENTERLINE PER STANDARD PLAN �u z INSTALL 2' WIDE STRIP OF TRUNCATED DOME DETECTABLE WARNING PATTERN PER I• 0 19 Z INSTALL NEW 20' WIDE DRIVEWAY FROM STA 6 +97 TO STA 7 +17 PER STANDARD Z 20 0 NOTCHES EVERY 6' PER STANDARD PLAN F004 TO CREATE NEW OR MODIFIES LANDSCAPING ISLANDS. d � a RELOCATE EXISTING WOOD POST AND SIGN. •a •> = W .o 0 — V) z cr a Q 2 � M \ H � o ri o m w LEGEND �--� TRAFFIC SIGN O CONSTRUCTION NOTE CD SIGN INSTALLATION NOTE — — TEMPORARY CONSTRUCTION EASEMENT PROPERTY LINE 40 1 I in 11 2� PORTION OF NW 114 OF SEC. 19, T. 23 N., R. 05 E., W.M. - _ - 16 550 S.W. 7TH ST. 20 ( _ 15 I R/W S.W. 7TH ST. ,80I ( , .a 75 12 r7 - 4 ) - 12 LO 15 12 % 2 r I 7<% (z /i �0 20 I )° �fj �l 11 20 i '-_' -- _ITT J ....... N 10 14 1 13 0~� Salomon ..._ _... .. . , 1 4' 9+50 80+00 MN r + O CV / / ---- 5 YO •�� 21 6 o 20 12 500 S.W. 7TH ST. _ N m I R W U 10 —U5 10+50 11+00 11 + 50 - 12 +00 112 4 �n N R3 -5R R4 -8 PLAN H009. N ~� INSTALL DOUBLE YELLOW CENTERLINE PER STANDARD PLAN H001. 18 INSTALL 2' WIDE STRIP OF TRUNCATED DOME DETECTABLE WARNING PATTERN PER I• 0 19 REMOVE EXISTING DRIVEWAY, CURB AND PLANTER STRIP. INSTALL NEW 20' WIDE DRIVEWAY FROM STA 6 +97 TO STA 7 +17 PER STANDARD Z 20 INSTALL TYPE 6 EXTRUDED CONCRETE CURB WITH DRAINAGE NOTCHES EVERY 6' PER STANDARD PLAN F004 TO CREATE NEW OR MODIFIES LANDSCAPING ISLANDS. d Z 21 RELOCATE EXISTING WOOD POST AND SIGN. 0 — V) z 2 ri J W3 i w LEGEND �--� TRAFFIC SIGN O CONSTRUCTION NOTE CD SIGN INSTALLATION NOTE — — TEMPORARY CONSTRUCTION EASEMENT PROPERTY LINE 40 1 I in 11 2� PORTION OF NW 114 OF SEC. 19, T. 23 N., R. 05 E., W.M. - _ - 16 550 S.W. 7TH ST. 20 ( _ 15 I R/W S.W. 7TH ST. ,80I ( , .a 75 12 r7 - 4 ) - 12 LO 15 12 % 2 r I 7<% (z /i �0 20 I )° �fj �l 11 20 i '-_' -- _ITT J ....... N 10 14 1 13 0~� Salomon ..._ _... .. . , 1 4' 9+50 80+00 MN r + O CV / / ---- 5 YO •�� 21 6 o 20 12 500 S.W. 7TH ST. _ N m I R W U 10 —U5 10+50 11+00 11 + 50 - 12 +00 112 4 �n STA -- --STOP BAR, LT. ! R /W;i 20'R- CONSTRUCTION NOTES I O REMOVE EXISTING TREE. O REMOVE EXISTING CURB AND GUTTER AS NECESSARY. INSTALL NEW CURB, GUTTER AND SIDEWALK RAMP TYPE 1--B PER WSDOT STANDARD PLAN F--3a WITH TRUNCATED DOME DETECTABLE WARNING PATTERN. INSTALL 3' X 4' LANDING CONNECTING SIDEWALK RAMP TO EXISTING SIDEWALK. O REMOVE EXISTING RAISED PAVEMENT MARKERS FROM WITHIN THE INTERSECTION. O4 REMOVE EXISTING LANE STRIPE FROM STA. 0 +40 TO STA. 1+80. INSTALL APPROACH STRIPE PER STANDARD PLAN H002. O INSTALL PLASTIC 24" STOP BAR. O INSTALL PLASTIC CROSSWALK STRIPE (TYPICAL) PER STANDARD PLAN H012. 7 INSTALL PLASTIC MODIFIED CROSSWALK STRIPE ON SIDEWALK (TYPICAL) PER STANDARD PLAN H012, EXCEPT THE STRIPE LENGTH SHALL MATCH THE SIDEWALK WIDTH (APPROX. 5'). g INSTALL PLASTIC TYPE 2R TRAFFIC ARROW PER STANDARD PLAN H009. O9 REMOVE EXISTING STOP SIGN AND POST. 10 REMOVE EXISTING CONCRETE DRIVEWAY. INSTALL NEW CURB AND GUTTER PER STANDARD PLAN F008 TO MATCH EXISTING CURB. BACK FILL AREA BETWEEN SIDEWALK AND CURB WITH TOPSOIL AND PLANT GRASS TO MATCH EXISTING. 11 REMOVE CURB AROUND PERIMETER OF EXISTING PARKING ISLAND. REMOVE TOPSOIL TO DEPTH OF 6" BELOW ADJACENT PAVEMENT. PROPERTY OWNER RESPONSIBLE FOR REMOVING LANDSCAPING PLANTS AND SPRINKLER SYSTEM. INSTALL CRUSHED STONE BASE, COMPACT AND REPAVE WITH TYPE B ASPHALT TO MATCH EXISTING PAVEMENT THICKNESS. 12 SAW CUT AND REMOVE ASPHALT FROM INTERIOR OF ISLAND, 12" FROM BACK OF PROPOSED CURB. AFTER CURB IS INSTALLED BACKFILL WITH TOPSOIL TO TOP OF CURB. PROPERTY OWNER RESPONSIBLE FOR INSTALLATION OF LANDSCAPING PLANTS AND SPRINKLER SYSTEM. 13 WIDEN EXISTING DRIVEWAY TO 40' WIDTH PER STANDARD PLAN F006 TO SERVE ENTERING AND EXITING VEHICLES. 14 CITY OF RENTON TO REMOVE CONCRETE POST AND AIR VACUUM RELEASE. 15 REMOVE EXISTING PARKING STALL MARKINGS (TYPICAL). rn Q V) w i f Q m V) o �+ � I Qf t ill f� Ii ff i i� f� I� I I I 'I ! �i I' is 11 ROLL 20� 12' 120 to 0 O 0 + 0 12' 12' N g M1I \-20)R S.W. 7TH ST. 1 STA. 0 +40 STOP BAR. LT. 30" 30" 2401 24„ U r c( c 12' vi►i W s Q ii 1� I� BEGIN APPROACH STRIPE, 12' LT. a STA. 0 +60 TRAFFIC ARROW, LT. j TRAFFIC SIGN, 29' LT. IKAFFIC ARROW, LT. STA. 1+ 80 END APPROACH STRIPE, 12' LT. TRAFFIC SIGN, 29' LT. FR . 187 RIGHT LANE MUST TURN RIGHT 30" ENTER T) 30" ONLY 30" R3 -7R N R3 -5R R4 -8 PLAN H009. N ~� INSTALL DOUBLE YELLOW CENTERLINE PER STANDARD PLAN H001. STA -- --STOP BAR, LT. ! R /W;i 20'R- CONSTRUCTION NOTES I O REMOVE EXISTING TREE. O REMOVE EXISTING CURB AND GUTTER AS NECESSARY. INSTALL NEW CURB, GUTTER AND SIDEWALK RAMP TYPE 1--B PER WSDOT STANDARD PLAN F--3a WITH TRUNCATED DOME DETECTABLE WARNING PATTERN. INSTALL 3' X 4' LANDING CONNECTING SIDEWALK RAMP TO EXISTING SIDEWALK. O REMOVE EXISTING RAISED PAVEMENT MARKERS FROM WITHIN THE INTERSECTION. O4 REMOVE EXISTING LANE STRIPE FROM STA. 0 +40 TO STA. 1+80. INSTALL APPROACH STRIPE PER STANDARD PLAN H002. O INSTALL PLASTIC 24" STOP BAR. O INSTALL PLASTIC CROSSWALK STRIPE (TYPICAL) PER STANDARD PLAN H012. 7 INSTALL PLASTIC MODIFIED CROSSWALK STRIPE ON SIDEWALK (TYPICAL) PER STANDARD PLAN H012, EXCEPT THE STRIPE LENGTH SHALL MATCH THE SIDEWALK WIDTH (APPROX. 5'). g INSTALL PLASTIC TYPE 2R TRAFFIC ARROW PER STANDARD PLAN H009. O9 REMOVE EXISTING STOP SIGN AND POST. 10 REMOVE EXISTING CONCRETE DRIVEWAY. INSTALL NEW CURB AND GUTTER PER STANDARD PLAN F008 TO MATCH EXISTING CURB. BACK FILL AREA BETWEEN SIDEWALK AND CURB WITH TOPSOIL AND PLANT GRASS TO MATCH EXISTING. 11 REMOVE CURB AROUND PERIMETER OF EXISTING PARKING ISLAND. REMOVE TOPSOIL TO DEPTH OF 6" BELOW ADJACENT PAVEMENT. PROPERTY OWNER RESPONSIBLE FOR REMOVING LANDSCAPING PLANTS AND SPRINKLER SYSTEM. INSTALL CRUSHED STONE BASE, COMPACT AND REPAVE WITH TYPE B ASPHALT TO MATCH EXISTING PAVEMENT THICKNESS. 12 SAW CUT AND REMOVE ASPHALT FROM INTERIOR OF ISLAND, 12" FROM BACK OF PROPOSED CURB. AFTER CURB IS INSTALLED BACKFILL WITH TOPSOIL TO TOP OF CURB. PROPERTY OWNER RESPONSIBLE FOR INSTALLATION OF LANDSCAPING PLANTS AND SPRINKLER SYSTEM. 13 WIDEN EXISTING DRIVEWAY TO 40' WIDTH PER STANDARD PLAN F006 TO SERVE ENTERING AND EXITING VEHICLES. 14 CITY OF RENTON TO REMOVE CONCRETE POST AND AIR VACUUM RELEASE. 15 REMOVE EXISTING PARKING STALL MARKINGS (TYPICAL). rn Q V) w i f Q m V) o �+ � I Qf t ill f� Ii ff i i� f� I� I I I 'I ! �i I' is 11 ROLL 20� 12' 120 to 0 O 0 + 0 12' 12' N g M1I \-20)R S.W. 7TH ST. 1 STA. 0 +40 STOP BAR. LT. 30" 30" 2401 24„ U r c( c 12' vi►i W s Q ii 1� I� BEGIN APPROACH STRIPE, 12' LT. a STA. 0 +60 TRAFFIC ARROW, LT. j TRAFFIC SIGN, 29' LT. IKAFFIC ARROW, LT. STA. 1+ 80 END APPROACH STRIPE, 12' LT. TRAFFIC SIGN, 29' LT. FR . 187 RIGHT LANE MUST TURN RIGHT 30" ENTER T) 30" ONLY 30" R3 -7R R5 -1 R3 -5R R4 -8 PLAN H009. 17 INSTALL DOUBLE YELLOW CENTERLINE PER STANDARD PLAN H001. 30" TRAFFIC SIGN DETAILS T 3�2 /a2 CONSTRUCTION NOTES CONTINUED 16 INSTALL PLASTIC TYPE I TRAFFIC ARROW PER STANDARD PLAN H009. 17 INSTALL DOUBLE YELLOW CENTERLINE PER STANDARD PLAN H001. 18 INSTALL 2' WIDE STRIP OF TRUNCATED DOME DETECTABLE WARNING PATTERN PER I• WSDOT STANDARD PLAN F -3o. 19 REMOVE EXISTING DRIVEWAY, CURB AND PLANTER STRIP. INSTALL NEW 20' WIDE DRIVEWAY FROM STA 6 +97 TO STA 7 +17 PER STANDARD � PLAN F006. � 20 INSTALL TYPE 6 EXTRUDED CONCRETE CURB WITH DRAINAGE NOTCHES EVERY 6' PER STANDARD PLAN F004 TO CREATE NEW OR MODIFIES LANDSCAPING ISLANDS. MATCH EXISTING CURB. 21 RELOCATE EXISTING WOOD POST AND SIGN. TRANSPORTATION PLANNING & ENGINEERING, INC. 2223 -1121H AVENUE NORTFIEAST, SUITE 101 eEUEwE, wAsraNCTON gaooa TEL. (425) 455-5320 fAX (425) 453 -5759 OF N. 4v� row►t~ EMG\ /0 -7 -03 EARS �isiob • 20 0 20 40 Scale reet o � 0 �11 8 ;� 000 —741 ► 04 &-a— .•-� 0 19 TYPE 1 JUNCTION BOX — J015, J016 91 TYPE 2 JUNCTION BOX — J015, J016 � v Q � I J Z CONDUIT CONTROLLER CABINET � SERVICE CABINET F=-- 0 y SIGNAL STANDARD — MOUNTED �Q � SIGNAL STANDARD N0. • Z CONSTRUCTION NOTE W pp i5 O Qi (� II a N Q •> (11 N I Z ICL E E �E CC °' ` > Q LL_ Q Q � V � w Q _Z _j U N w 0 Of m a_ N ;� VEHICLE SIGNAL HEAD —741 ► 04 &-a— .•-� 0 19 TYPE 1 JUNCTION BOX — J015, J016 91 TYPE 2 JUNCTION BOX — J015, J016 � v TYPE 3 JUNCTION BOX — J015, J016 0 PREEMPTION DETECTOR (EVP) Z CONDUIT CONTROLLER CABINET � SERVICE CABINET 0 VIDEO VEHICLE DETECTOR y SIGNAL STANDARD — MOUNTED �Q � SIGNAL STANDARD N0. a CONSTRUCTION NOTE W pp i5 O SIGN INSTALLATION NOTE (� II a •> ICL E E �E CC °' v� a� f� of SIGNAL FACE SCHEDULE PORTION OF NW 1/4 OF R O 12" �(j _ � NOTES: / I 1. ALL VEHICLE SIGNAL HEADS SHALL BE CONVENTIONAL HEADS Y O 12" Lf WITH RED AND GREEN LED INDICATIONS, BACKPLATES AND PEDESTRIAN TUNNEL VISORS. ALL YELLOW INDICATIONS SHALL BE G O 12 HEAD N0. INCANDESCENT. ALL VEHICLE SIGNAL HEADS SHALL USE MOUNTING TYPE M. USE STANDARD PLANS J019 AND J020. 26,27,66,67 VEHICLE HEAD N0. 86,87 2. ALL PEDESTRIAN SIGNAL HEADS SHALL HAVE LEO SYMBOLIC I 21 p22,41,42 LEGENDS AND 'Z' CRATE VISORS. PEDESTRIAN SIGNAL HEADS 61 962981,82 SHALL USE CLAM SHELL TYPE E MOUNTS. LEGEND o VEHICLE SIGNAL HEAD —741 ► 04 &-a— SIGNAL STANDARD, TYPE III 19 TYPE 1 JUNCTION BOX — J015, J016 91 TYPE 2 JUNCTION BOX — J015, J016 0 TYPE 3 JUNCTION BOX — J015, J016 0 PREEMPTION DETECTOR (EVP) Z CONDUIT CONTROLLER CABINET � SERVICE CABINET VIDEO VEHICLE DETECTOR SIGNAL STANDARD — MOUNTED TRAFFIC SIGN � SIGNAL STANDARD N0. a CONSTRUCTION NOTE pp i5 O SIGN INSTALLATION NOTE (� II W o •> ICL Q � V � w Q N 0 o m of SIGNAL FACE SCHEDULE PORTION OF NW 1/4 OF R O 12" �(j _ � NOTES: / I 1. ALL VEHICLE SIGNAL HEADS SHALL BE CONVENTIONAL HEADS Y O 12" Lf WITH RED AND GREEN LED INDICATIONS, BACKPLATES AND PEDESTRIAN TUNNEL VISORS. ALL YELLOW INDICATIONS SHALL BE G O 12 HEAD N0. INCANDESCENT. ALL VEHICLE SIGNAL HEADS SHALL USE MOUNTING TYPE M. USE STANDARD PLANS J019 AND J020. 26,27,66,67 VEHICLE HEAD N0. 86,87 2. ALL PEDESTRIAN SIGNAL HEADS SHALL HAVE LEO SYMBOLIC I 21 p22,41,42 LEGENDS AND 'Z' CRATE VISORS. PEDESTRIAN SIGNAL HEADS 61 962981,82 SHALL USE CLAM SHELL TYPE E MOUNTS. LEGEND —� VEHICLE SIGNAL HEAD —741 ► PEDESTRIAN SIGNAL HEAD &-a— SIGNAL STANDARD, TYPE III 19 TYPE 1 JUNCTION BOX — J015, J016 91 TYPE 2 JUNCTION BOX — J015, J016 0 TYPE 3 JUNCTION BOX — J015, J016 0 PREEMPTION DETECTOR (EVP) — — CONDUIT CONTROLLER CABINET � SERVICE CABINET VIDEO VEHICLE DETECTOR SIGNAL STANDARD — MOUNTED TRAFFIC SIGN O SIGNAL STANDARD N0. O CONSTRUCTION NOTE WIRE NOTE O SIGN INSTALLATION NOTE (� II PAS MWN`r EO -1 RIW�>FpRMtR i 0 Z of SIGNAL FACE SCHEDULE PORTION OF NW 1/4 OF R O 12" �(j _ � NOTES: / I 1. ALL VEHICLE SIGNAL HEADS SHALL BE CONVENTIONAL HEADS Y O 12" Lf WITH RED AND GREEN LED INDICATIONS, BACKPLATES AND PEDESTRIAN TUNNEL VISORS. ALL YELLOW INDICATIONS SHALL BE G O 12 HEAD N0. INCANDESCENT. ALL VEHICLE SIGNAL HEADS SHALL USE MOUNTING TYPE M. USE STANDARD PLANS J019 AND J020. 26,27,66,67 VEHICLE HEAD N0. 86,87 2. ALL PEDESTRIAN SIGNAL HEADS SHALL HAVE LEO SYMBOLIC I 21 p22,41,42 LEGENDS AND 'Z' CRATE VISORS. PEDESTRIAN SIGNAL HEADS 61 962981,82 SHALL USE CLAM SHELL TYPE E MOUNTS. LEGEND —� VEHICLE SIGNAL HEAD —741 ► PEDESTRIAN SIGNAL HEAD &-a— SIGNAL STANDARD, TYPE III 19 TYPE 1 JUNCTION BOX — J015, J016 91 TYPE 2 JUNCTION BOX — J015, J016 0 TYPE 3 JUNCTION BOX — J015, J016 -� PREEMPTION DETECTOR (EVP) — — CONDUIT CONTROLLER CABINET � SERVICE CABINET VIDEO VEHICLE DETECTOR SIGNAL STANDARD — MOUNTED TRAFFIC SIGN O SIGNAL STANDARD N0. O CONSTRUCTION NOTE WIRE NOTE O SIGN INSTALLATION NOTE (� II PAS MWN`r EO -1 RIW�>FpRMtR WIRING SCHEDULE 3 3 ---- ► F t — `Fri .. .. .._. _ ... ...... ... T....�. _....._ . SEC. 19, T. 23 N., R. 05 E., W.M. 20 0 20 40 scale feet 7 � 5 5 4 j 4 I 4 FA, � I Mail 6 _'.. I ... .. 1 �...... ___ -- r--� A 00 '~ '-_ 9+50 i 90 +06- 13 6. ...... _ _ 5D v _ -- _ ,0 _ D +50 11 +00 11 +50 12 +0 1 , w ._ ___...._ w ,� y w w .� i y,, — w _ 3 /42 41 , 2 s _ s .ti vI L _ R._ P - _.. 10 d Idle � Ce r+e t�- „,.,� c -f T� S. W. 7TH ST. 2 _ - 2 � 167 1 �• -- W 7 TH S T TRAFFIC SIGN DETAILS USE STANDARD PLAN G022 AND WSDOT SIGN FABRICATION MANUAL R9 -3a D3 -101 CD 18 p LI N D AVE SW o 18” 18" D3 -101 18 PIP Sw 7TH ST (ID 60" op R3 -5R (i) 36" ONLY 30" /i t� i� o 1 j 8 r 9 _ ' 8 CONSTRUCTION NOTES i i I 11 13 _ ,, 9 USE STANDARD PLANS J021, J0241 J025, J029, J032, J035, J036 AND J037. 14 1 * INSTALL FOUNDATION AND TYPE III SIGNAL STANDARD WITH 40' MAST ARM, TWO VEHICLE SIGNAL I O ' I HEADS, EVP DETECTOR, TWO PEDESTRIAN SIGNAL HEADS, TWO PPB —M, TERMINAL CABINET TRAFFIC SIGN, AND 250 WATT HPS M —C —III LUMINAIRE AT 35' MOUNTING HEIGHT ON 16' ARM. ° I 1 2 * INSTALL FOUNDATION AND TYPE III SIGNAL STANDARD ' S D D WITH 27 MAST ARM, TWO VEHICLE SIGNAL HEADS, EVP DETECTOR, PEDESTRIAN SIGNAL HEAD, PPB —M TERMINAL CABINET TWO TRAFFIC SIGNS C S G S • _ AND 250 WATT HPS M —C —III LUMINAIRE AT 3 MOUNTING ' 5 OUN ING HEIGHT ON 6 ARM. INSTALL FOUNDATION AND TYPE III SIGNAL STANDARD WITH 28 MAST ARM, TWO VEHIC E SIGNAL ,, • I s O L HEADS, EVP DETECTOR, PEDESTRIAN SIGNAL HEAD TERMINAL CABINET TWO TRAFFIC SIGNS AND 250 i _ ' ► V) 1 t ! WATT HPS M--C —III LUMINAIRE AT 35' MOUNTING HEIGHT ON 6' ARM. > * , INSTALL FOUNDATION AND TYPE III SIGNAL STANDARD WITH 25 MAST ARM, TWO VEHICLE SIGNAL HEADS, EVP DETECTOR, TWO PEDESTRIAN SIGNAL HEADS TERMINAL A {� ` I o CABINET, Two TRAFFIC SIGNS, AND ► t � 1=1 •:1 250 WATT HPS M--C —III LUMINAIRE AT 35 MOUNTING HEIGHT ON 8 ARM. ° is _z I ? ► + II I� J 5 INSTALL FOUNDATION AND TYPE PPB POST WITH TWO PPB —M PER STANDARD PLANS J022 AND J024. INSTALL FOUNDATION AND TYPE PPB POST WITH ONE PPB —M PER STANDARD PLANS J022 AND J024. DRILL 1 INCH DIAMETER HOLE IN THE BOTTOM OF LUMINAIRE ARM 1' FROM LUMINAIRE HEAD. INSTALL ! , CITY SUPPLIED VIDEO AND POWER CABLES FROM CONTROLLER CABINET () E TO LUMINAIRE ARM. COIL 6 Cr! ``'•; OF CABLE(S) AT LUMINAIRE ARM AND 10' AT CONTROLLER CABINET. INSTALL RUBBER GROMMET AND 10 SEAL HOLE ON LUMINAIRE ARM WITH CAULKING. CITY TO PROVIDE AND INSTALL CAMERA AND 1 I ' RELATED EQUIPMENT REQUIRED FOR COMPLETE VIDEO DETECTION SYSTEM. INSTALL FOUNDATION AT ' I s $ NS LL OU DATION LIND AVE. S.W. STA. 0 +56, 31 LT. PER STANDARD PLAN J028. INSTALL it i NEMA TYPE P TRAFFIC SIGNAL CONTROLLER CABINET, NEMA TRAFFIC SIGNAL CONTROLLER AND = N AUX!LIARY EQUIPMENT. INSTALL FOUNDATION AT LIND AVE. S.W. STA. 0 +63, 31 LT. PER STANDARD PLAN J010. INSTALL ,I +�►�w��: 120/240 VOLT SINGLE PHASE ELECTRICAL SERVICE CABINET. COORDINATE WITH DENNIS DORE AT PUGET SOUND ENERGY Al 253 - 395 - 7023 FOR SERVICE CONNECTION. I 1 p EXISTING LIGHT STANDARD TO BE REMOVED BY PUGET SOUND ENERGY. COORDINATE WITH PAUL } KINBERG AT PUGET SOUND ENERGY AT 425-456-2618. 26 8. J` WAS TRANSPORTATION PLANNING P & ENGINEERING INC. h G x 7�'•i 1 a� t 2223-112TH AVENUE NORTHEAST, SUITE 101 p SELLEAK, WASHINGTON 98004 `'s� °'_T TEL. ( 425) 455-5320 FAX ( 425) 453-5759 /0-7-07 _ tics �ra�ca SIGNAL PHASING DIAGRAM Ho Es PEDESTRIAN MOVEMENT ----► PROTECTED VEHICLE MOVEMENT -- ♦► PERMITTED VEHICLE MOVEMENT PREEMPTION SCHEDULE CIRCUIT CONDUIT SIZE CONDUCTORS AL B 4 +8 C 2 +6 D 4 +8 taws ■GWa�������ns��rr� op R3 -5R (i) 36" ONLY 30" /i t� i� o 1 j 8 r 9 _ ' 8 CONSTRUCTION NOTES i i I 11 13 _ ,, 9 USE STANDARD PLANS J021, J0241 J025, J029, J032, J035, J036 AND J037. 14 1 * INSTALL FOUNDATION AND TYPE III SIGNAL STANDARD WITH 40' MAST ARM, TWO VEHICLE SIGNAL I O ' I HEADS, EVP DETECTOR, TWO PEDESTRIAN SIGNAL HEADS, TWO PPB —M, TERMINAL CABINET TRAFFIC SIGN, AND 250 WATT HPS M —C —III LUMINAIRE AT 35' MOUNTING HEIGHT ON 16' ARM. ° I 1 2 * INSTALL FOUNDATION AND TYPE III SIGNAL STANDARD ' S D D WITH 27 MAST ARM, TWO VEHICLE SIGNAL HEADS, EVP DETECTOR, PEDESTRIAN SIGNAL HEAD, PPB —M TERMINAL CABINET TWO TRAFFIC SIGNS C S G S • _ AND 250 WATT HPS M —C —III LUMINAIRE AT 3 MOUNTING ' 5 OUN ING HEIGHT ON 6 ARM. INSTALL FOUNDATION AND TYPE III SIGNAL STANDARD WITH 28 MAST ARM, TWO VEHIC E SIGNAL ,, • I s O L HEADS, EVP DETECTOR, PEDESTRIAN SIGNAL HEAD TERMINAL CABINET TWO TRAFFIC SIGNS AND 250 i _ ' ► V) 1 t ! WATT HPS M--C —III LUMINAIRE AT 35' MOUNTING HEIGHT ON 6' ARM. > * , INSTALL FOUNDATION AND TYPE III SIGNAL STANDARD WITH 25 MAST ARM, TWO VEHICLE SIGNAL HEADS, EVP DETECTOR, TWO PEDESTRIAN SIGNAL HEADS TERMINAL A {� ` I o CABINET, Two TRAFFIC SIGNS, AND ► t � 1=1 •:1 250 WATT HPS M--C —III LUMINAIRE AT 35 MOUNTING HEIGHT ON 8 ARM. ° is _z I ? ► + II I� J 5 INSTALL FOUNDATION AND TYPE PPB POST WITH TWO PPB —M PER STANDARD PLANS J022 AND J024. INSTALL FOUNDATION AND TYPE PPB POST WITH ONE PPB —M PER STANDARD PLANS J022 AND J024. DRILL 1 INCH DIAMETER HOLE IN THE BOTTOM OF LUMINAIRE ARM 1' FROM LUMINAIRE HEAD. INSTALL ! , CITY SUPPLIED VIDEO AND POWER CABLES FROM CONTROLLER CABINET () E TO LUMINAIRE ARM. COIL 6 Cr! ``'•; OF CABLE(S) AT LUMINAIRE ARM AND 10' AT CONTROLLER CABINET. INSTALL RUBBER GROMMET AND 10 SEAL HOLE ON LUMINAIRE ARM WITH CAULKING. CITY TO PROVIDE AND INSTALL CAMERA AND 1 I ' RELATED EQUIPMENT REQUIRED FOR COMPLETE VIDEO DETECTION SYSTEM. INSTALL FOUNDATION AT ' I s $ NS LL OU DATION LIND AVE. S.W. STA. 0 +56, 31 LT. PER STANDARD PLAN J028. INSTALL it i NEMA TYPE P TRAFFIC SIGNAL CONTROLLER CABINET, NEMA TRAFFIC SIGNAL CONTROLLER AND = N AUX!LIARY EQUIPMENT. INSTALL FOUNDATION AT LIND AVE. S.W. STA. 0 +63, 31 LT. PER STANDARD PLAN J010. INSTALL ,I +�►�w��: 120/240 VOLT SINGLE PHASE ELECTRICAL SERVICE CABINET. COORDINATE WITH DENNIS DORE AT PUGET SOUND ENERGY Al 253 - 395 - 7023 FOR SERVICE CONNECTION. I 1 p EXISTING LIGHT STANDARD TO BE REMOVED BY PUGET SOUND ENERGY. COORDINATE WITH PAUL } KINBERG AT PUGET SOUND ENERGY AT 425-456-2618. 26 8. J` WAS TRANSPORTATION PLANNING P & ENGINEERING INC. h G x 7�'•i 1 a� t 2223-112TH AVENUE NORTHEAST, SUITE 101 p SELLEAK, WASHINGTON 98004 `'s� °'_T TEL. ( 425) 455-5320 FAX ( 425) 453-5759 /0-7-07 _ tics �ra�ca SIGNAL PHASING DIAGRAM Ho Es PEDESTRIAN MOVEMENT ----► PROTECTED VEHICLE MOVEMENT -- ♦► PERMITTED VEHICLE MOVEMENT PREEMPTION SCHEDULE CIRCUIT PHASE A 2 +6 B 4 +8 C 2 +6 D 4 +8 ROLL ZO� FR � 188 r .4a r s 'f2 /c2 4 0 o 0 .. � IV— O E� 726 P.P.B. 27 FIELD WIRE TERMINATIONS CONTROLLER C 727 0 726 g WIRE ! P.P.B. 26 727 o TERMINATIONS O C P.P.B. 87 786 g 9 -.4- 787 0 00 I �L SIGNAL HEAD 21 ° Q R 621 R SIGNAL HEAD 22 4 911 1 826 (n \ TERMINAL CABINET 3 912 E.V.P. c 827 .Q Y 62 0 E.V.P. A R 621 R _ 2 Q G 623 G 1 92 829 F" o° 921 0 Y 622 0 F? 62 R 0 522 2 836 0 Z N C� 624 B 922 Y G 623 G —0-622 0 SIGNAL HEAD 81 SIGNAL HEAD 82 Y 923 E.V.P. A 837 3 v .0 Q, 625 vy 624 g G 623 G BL 931 838 w F= T- 923 �Bl­ 625 -- g 624 g R 681 R- E.V.P. D R 681 R 932 839 0 N W 625 W Y 682 0- 981--o- 7-682-0— 933 E.V.P. Ev 0 846 4 $ =, J EG: G 683 G- 982 Y G 683 G 0 941 4 0 $47 ° 0 z V Q 684 B- 983 L 684 B Y 942 E.V.P. a 866 651 R 685 W- 685 W BL 943 2 867 W v 1652 TERMINAL CABINET 4 951 5 �' 868 6 Q 952 E.V.P. A W 869 Q 653 G 953 a o C-) PED. HEAD 27 654 B 961 6 > Q 721 TO O 962 E.V.P. C z F- � 2 R 655 R 681 R 963 u 722 G CONTROLLER 0 682 BL 971 3 � 725 W R 721 R CABINET PED. HEAD 26 G 683 G 972 E -4-P. e o B G 722 G B 684 B 973 CL 0 725 W 7,;1 R 685 p 981 8 7�2 G TO Y 982 E.V.P. D 726 VIDEO 7L5 W R 721 CON TROLLER BL 983 9 0 727 VEHICLE R G 722 G CABINET r DETECTOR 0 o 725 W CL v. � 00 � B 726 o � � � :E PED. HEAD 87 0 727 VIDEO 611 M a p L E 6 04 5 VEHICLE R W ' � Q 781 --- R 7 1 DETECTOR 0 613 o E� 3 4 782 G R 8 R C 614 - - 782 B w O 7 W G E--� _ 8 5 G W 615 1 g 785 W sls �o2 -- 0 B 786 g 617 f =o E (� 787 618 a I 711 HAND m E 19 715 NEUTRAL 16 1 cr R 621 71E DETECTOR 17 �N p 622 ril r— M - I - •(7) G 623 21 717 DE-ECTOR o - -► 624 22 R 721 HAND � �6 B a S. W. 7 TH S T. �,� 625 2 G -- 722 MAN 26 626 -j W 725 NEUTRAL 27 2 Y 627 B 726 DETECTOR 26 a 0 � 727 DE'ECTOR 2 1 29 N 731 HAND -- 631 732 MAN 4 08 632 735 NEUTRAL 36 3 633 31 736 DETECTOR 37 V) uj 634 32 737 DETECTOR N Q 1635 Q 741 HAND 3 636 a 742 MAN 745 NEUTRAL 45 4 4 o z 637 w i 47 v N 638 a. Q DETECTOR a II � SIGNAL HEAD 61 639 "' z 747 DE -ECTOR 641 N 751 HAND z R 661 R SIGNAL HEAD 62 TERMINAL CABINET 1 R 642 2 MAN Q 0 41 56 ^ Y-662 0 E.V.P. C R 661 R G 643 755 NEUTRAL 57 5 a z R 661 R g 644 42 756 DETECTOR = , G 663 G 961 0 Y 662 0 62 645 4 757 DETECTOR o W 664 B 962 Y G 663 G 0 6 0 646 J R 701 H N a 0 c; SIGNAL HEAD 41 SIGNAL_ HEAD 42 TERMINAL CABINET 2 665 W 963 L 664 g G 663 G 647 �< G 7 2 MAN 66 W a E.V.P. B [665 W B 664 B 648 N W 765 NEUTRAE 67 6 R 641 R R 641 R 10, 9 41 0 R 6 41 -- R W 6 6 5 W 651 0 766 DETECTOR Y 642 0 Y 642 0 R ss2 W B 771 HAND FG G 643 G 942 Y G 643 G p 642 0 0 '� G 53 � 772 MAN 644 [—B 943 L 644 B G 643 G 611 R g 654 775 NEUTRAL 76 7 a 645 W 645 W FVB= 644 g 612 W 655 5 776 DETECTOR 77 n. 645 W 613 G 656 Q 777 DETECTOR Q PED. HEAD 67 614 B 657 W R=781 HAND U w 658 a. G 782 MAN N Q 761 R 615 TO 659 u' w 785 NEUTRAL 86 8 0 671 762 G CONTROLLER R 661 p 786 DETECTOR 87 672 765 W CABINET O 662 61 g 787 DETECTOR 673 TO 766 R 751 R G 663 62 674 CONTROLLER P.P.B. 67 B G 762 G g 564 76 0 76 5 W w' 665 675 CABINET B 766 666 6 B L 511 PED. HEAD 66 PED. HEAD 86 0 767 VIDEO 667 W W 513 668 OR 761 R 781 R VEHICLE 669 W S14 z 762 G DETECTOR 782 G R 781 R 671 GN 515 0 765 W N a w G 782 G 672 W 516 7 B VIDEO ��� �;,�Nc 785 673 z P.P.B. 66 66 VEHICLE oP���. P.P.B. 86 786 B 785 W 674 Z 767t-0 DETECTOR ". 787 0 B 786 g 7 R 761 R 0-787--o 677 � G 76 G U , �, s �, 678 p F �f�isTEaEG`��. 679 501 AC+ � � 76 W �,�,,,LE N B B 766 g /0-7-o3 R 581 -W- Sot Ac- o 0 682 (� a 10— 767 " G 683 B 684 TRANSPORTATION PLANNING .w W—"5 5 8 z NOTE: + INDICATES A SPLICE ac ENGINEERING INC. sas � 687 2223 -112TH AVENUE NORTHEAST, SUITE 101 689 BELLEVUE, WASHINGTON 98004 TEL. (425) 455 -5320 FAX (425) 453 -5759 Fw% 0 L 12 01 F Ft 18 9 F-- 0 8 • FIELD LOCATION o� r 000 POLE ATTACHMENT POINT ANGLES (de C 0) O O o I Cn m�mmm�m�, J mmm�P � J .� F-~ 2 '~ �- UJ a a ~ mmmm�o O C) mm .c -v =mmo00 ►- N 0 �� ►m . Q I LL N CL J C N (n Z Z 00 I (7 • F Q () Lj Q O 0 Z W Z F•- < K J w 17101 F- 0 CL N O o Cq t Z W C9 W I W a •> c 38i a Q 0 m 111111 (n I 111111¢ SIGNAL ARM ATTACHMENT POINT F-r,p-Ni n A. Vehicle Signal Head B. Sign, Std Plon G -9 C. Luminaire Arm D. Pre —Empt Detector E. Signal Most Arm F. Luminaire G. Pedestrian Signal Head H. Terminal Cabinet I. Pedestrian Push Button Assembly, Std Plan J -5a J. Handhole, Std Plan J -7c or J -8 CKWI SE O C'\1 �, A,CHM Rom V 9o° O �_ Q POLE ORIENTATION ANGLE (P.O.A.) DEGREES CLOCKWIS FROM OFFSET LINE TO OOPOIN T TO LOCATION STATION ALL HANDHOLES AT 1800 POLE ORIENTATION AND ATTACHMENT POINT DETAIL PLAN VIEW NOTES O1 MOUNTING COUPLING TO BE INSTALLED BY FABRICATOR AT OFFSET DISTANCES INDICATED IN CHART. IF TYPE "N" MOUNTING IS USED, DRILL 1" HOLE IN MAST ARM AND INSTALL PLASTIC SPLIT BUSHING FOR CABLE ENTRANCE. O2 FIELD INSTALLED. O3 SEE SPECIAL PROVISIONS FOR LUMINAIRE ARM TYPE. OFOUNDATIONS SHALL CONFORM TO THE FOUNDATION DETAILS IN THE STANDARD PLANS, EXCEPT ANCHOR BOLT SIZE, MATERIAL, AND BOLT CIRCLE SHALL CONFORM TO DETAILS ON THE PRE — APPROVED PLANS OR SHALL BE AS APPROVED BY THE BRIDGE AND STRUCTURES OFFICE. i 2 TYPE PPB PPB POST O II O TYPE PS PED. HEAD STANDARD 0 I 0 TYPE I VEHICLE HEAD STANDARD A � 1 � L u I I L- 1„ I YPE � 1 I FL_ .]L vVl�u V1� LVVL Vr" Jf�UULUGR MAST ARM 60MBINATION LIGHTING STRAIN POLE COMBINATION LIGHTING TYPE SD SIGNAL STANDARD AND MAST ARM STANDARD AND STRAIN SPECIAL DESIGN STANDARD SIGNAL STANDARD POLE STANDARD D • FIELD LOCATION o� r SIGNAL MAST ARM POLE ATTACHMENT POINT ANGLES (de C OFFSET O O o m�� m�mmm�m�, mmm�P c� w a a mmmm�o mm .c -v =mmo00 ►- - C • �� ►m mE C N •C CT C 00 o Cq t Z W C9 W I W a •> c 38i a Q 0 m 111111 (n I 111111¢ SIGNAL ARM ATTACHMENT POINT F-r,p-Ni n A. Vehicle Signal Head B. Sign, Std Plon G -9 C. Luminaire Arm D. Pre —Empt Detector E. Signal Most Arm F. Luminaire G. Pedestrian Signal Head H. Terminal Cabinet I. Pedestrian Push Button Assembly, Std Plan J -5a J. Handhole, Std Plan J -7c or J -8 CKWI SE O C'\1 �, A,CHM Rom V 9o° O �_ Q POLE ORIENTATION ANGLE (P.O.A.) DEGREES CLOCKWIS FROM OFFSET LINE TO OOPOIN T TO LOCATION STATION ALL HANDHOLES AT 1800 POLE ORIENTATION AND ATTACHMENT POINT DETAIL PLAN VIEW NOTES O1 MOUNTING COUPLING TO BE INSTALLED BY FABRICATOR AT OFFSET DISTANCES INDICATED IN CHART. IF TYPE "N" MOUNTING IS USED, DRILL 1" HOLE IN MAST ARM AND INSTALL PLASTIC SPLIT BUSHING FOR CABLE ENTRANCE. O2 FIELD INSTALLED. O3 SEE SPECIAL PROVISIONS FOR LUMINAIRE ARM TYPE. OFOUNDATIONS SHALL CONFORM TO THE FOUNDATION DETAILS IN THE STANDARD PLANS, EXCEPT ANCHOR BOLT SIZE, MATERIAL, AND BOLT CIRCLE SHALL CONFORM TO DETAILS ON THE PRE — APPROVED PLANS OR SHALL BE AS APPROVED BY THE BRIDGE AND STRUCTURES OFFICE. i 2 TYPE PPB PPB POST O II O TYPE PS PED. HEAD STANDARD 0 I 0 TYPE I VEHICLE HEAD STANDARD A � 1 � L u I I L- 1„ I YPE � 1 I FL_ .]L vVl�u V1� LVVL Vr" Jf�UULUGR MAST ARM 60MBINATION LIGHTING STRAIN POLE COMBINATION LIGHTING TYPE SD SIGNAL STANDARD AND MAST ARM STANDARD AND STRAIN SPECIAL DESIGN STANDARD SIGNAL STANDARD POLE STANDARD D * FUTURE SIGN BY OTHERS ROLL 2 FFt 190 r� 10 4 • FIELD LOCATION STRAIN MOUNTING SIGNAL MAST ARM POLE ATTACHMENT POINT ANGLES (de I I FOUNDATION OFFSET m�� m�mmm�m�, mmm�P m��� mmmm�o mm =mmo00 • �� ►m * FUTURE SIGN BY OTHERS ROLL 2 FFt 190 r� 10 4 N� M 1 1 J 8 q U 0. r s 0 B M � 0 o SCOTCHLITE SILVER ON GREEN :r.« ' »Y:.7A7 TdCi:•.•.71Y:.Yd" 'r1T ..rA�•VR »h•• .T .T «T:.:: «•' .::d•!ii" �f «': '•':J:i :.•J:. ............................ jl• -?JiL7 :. :•AY «Y:.Y• ': is ............. sati•x :•.:. f f Q a° 00 q) d o� _ E O ARIABLE H 'Q w 3" 30" uj.v lot I SPACED A ---t BETWEEN � MOUNTING Q STRAPS mE BREAKER �E NNII �fV C pO� o0 EL %_ LIGHTING A 1920 � 0 00 _< I- S W Z N W 1440 � 52. LIGHTING CONTROL 1P = cmr W Q N .�I �J 1 \N = Z LIGHTING B 1920 C.H. 20 15 AMP 5 6 Q 1 1920 ENCLOSURE (MS- 24 -TB) (n Z (n c ) B 2 1920 LIGHTING D LIGHTING C 1920 20 9 10 a 2 1920 O 1920 Q Q z � Z I-- F- _j U Q uj 0 LL o SCOTCHLITE SILVER ON GREEN :r.« ' »Y:.7A7 TdCi:•.•.71Y:.Yd" 'r1T ..rA�•VR »h•• .T .T «T:.:: «•' .::d•!ii" �f «': '•':J:i :.•J:. ............................ jl• -?JiL7 :. :•AY «Y:.Y• ': is ............. sati•x :•.:. f f Q a° t � R q) d o� _ E O ARIABLE H 'Q w 3" 30" uj.v MAXIMUM SPACED A ---t BETWEEN MOUNTING MOUNTING :o E STRAPS mE BREAKER �E CURCUIT DESCRIPTION �fV C pO� o0 EL %_ o SCOTCHLITE SILVER ON GREEN :r.« ' »Y:.7A7 TdCi:•.•.71Y:.Yd" 'r1T ..rA�•VR »h•• .T .T «T:.:: «•' .::d•!ii" �f «': '•':J:i :.•J:. ............................ jl• -?JiL7 :. :•AY «Y:.Y• ': is ............. sati•x :•.:. f f Q L- :T« L............. • ... .... .... t � R a r _ , 4" ARIABLE VARIES TREET NAME - LETTERS: S'' - SERIES __EE_ STREET DESIGNATION - LETTERS 4" - SERIES "E" 0.080 GAUGE ALUMINIUM SIGNS SINGLE MESSAGE SIGNAL POLE I 1 41. VA {A aJ T av«i$ a r O f f 4#" T� 6 ® JtYi7L - _ s:a xAra ai J. TA i1 11 58 d1S4'• .. : b riSA A 1 .. •YIY Y xf 7 7d t t t M Y!t L JYT Yt TTT :A d t d4 7. 7 ITS! ! AT Y••IL.TST1f�M iTAYfdT T d7 X TArxA ': SY «T.•.a:tT«T �'T - ' TArsr$:- D Tr • D •+t Tst:T ..YaTnat:ea . 7 +r 1t:•Y :, ��r. rs r .!• ::.:. D S 4" VARIES 3" 30" VARI ABLE MAXIMUM m 0 0 z w METER BASE GROUND BAR ALL LETTERS: 6" - SERIES "E" AS PER PLANS R A DIRECTED Q S D D E E BY ENGINEER CENTER OF SIGN AT CENTER OF MAST ARM SIGN MAST ARM N r -- all VARIES 3" 30" VENLY 3" MAXIMUM SPACED A ---t BETWEEN MOUNTING MOUNTING W STRAPS T_ NO. BREAKER VOLTAMPS A CURCUIT DESCRIPTION 0 /Wp pO� AMP POLE LIGHTING A 1920 � 20 2 LIGHTING A W 2 15 1 1440 � 52. LIGHTING CONTROL 1P = cmr W 3 4 50 1 20 AMP 4soo S"AL LIGHTING B 1920 C.H. 20 15 AMP 5 6 20 1 1920 ENCLOSURE (MS- 24 -TB) LIGHTING B HURRFII 1920 (CS1201-1) B 2 1920 LIGHTING D LIGHTING C 1920 20 9 10 a 2 1920 1920 Q LIGHTING C 12 w Q 0 m 0 0 z w METER BASE GROUND BAR ALL LETTERS: 6" - SERIES "E" AS PER PLANS R A DIRECTED Q S D D E E BY ENGINEER CENTER OF SIGN AT CENTER OF MAST ARM SIGN MAST ARM A r -- VARIES 3" 30" VENLY 3" MAXIMUM SPACED A ---t BETWEEN MOUNTING MOUNTING STRAPS STRAPS T_ NO. &A A (-r ARM 1I GN SECTION A -A SIGN TO BE MOUNTED LEVEL AND HOLES DRILLED IN FIELD AFTER SIGNAL POLE IS LEVELED AND ALL SIGNAL FIXTURES INSTALLED. TYPICAL MOUNTING SIGN MOUNTING ON SIGNAL DUAL MESSAGE POLE MAST ARM (FIXED MOUNT) Y p� ADOPTED CITY OF RENTON STANDARD PLANS �F N •� o� LST DATE: 10/30/96 EVISION BY APPR DWG. NAME: GR02 SP PAGE: G022 TO PHOTO CELL MAIN 15Q TEST SWI TCH 50A 20A T SIGNAL 20A 20A 11 1 I 1 LIGHTING D o o • 51 50 • . 51 r. . • 51 53 • 51 0 49 0 Ibbi e 8 o 0 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898 -I) 58. SQUARE D LIGHTING CONTACTOR (981 0DPA32V02U0 61. SOUTHCO DOOR S.S. HINGE (F6 -3 -1) 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2-626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1"'X-25" GASKET CONTRACTOR IS RESPONSIBLE TO VERIFY METER ARRANGEMENT MEETS EUSERC REQUIREMENTS APPROVED BY: PUGET SOUND ENERGY TACOMA POWER 10.50 -&j MATERIAL: 8 O TYP COATING TYPE: DRAWN BY: MEKKI AL -AZADI 6, 0.75x1.25 TYP HARDWARE: QUANTITY: FINISH: W----?4 COLOR: ' 3. DATE: OCT 24. 200 PAGE: OF: POLE GROUND TERMINAL HAND HOLE ,v #8 BARE COPPER GROUND WIRE 11 1117 N/ 6- #7 BARS #4 HOOPS AT 12 CENTER � II II 1 4 -GALV. STEEL ANCHOR BOLTS � � I LL 0 SIZE TO FIT POLE REQUIREMENT ���\ SECTION A -A WIRE CAGE ION 3' S0. OR RD. � JUNCTION 80X CONCRETE PAD Oy 4" _T 7, _ o" CONDUIT SIZE AS REQUIRED 5/8" x 8' COPPER CLAD METALIC GROUND ROD SIGNAL POLE FOUNDATION Y p� ADOPTED CITY OF RENTON STANDARD PLANS 'P� N IT O� LST DATE: 12/96 DWG. NAME: JR--21 NOTES: 49. 225 AMP COPPER BUSSING 18 PLCS PANNEL 50. C.H. 2P 100 AMP MAIN (BAB2100) 51. C.H. 2P 20 AMP BREAKER (BAB2020) 52. C.H. 1P 50 AMP BREAKER (BAB1050) ' 53. C.H. 1P 20 AMP BREAKER (BAB1020) 54. C.H. 1P 15 AMP BREAKER (BAB1015) 55. MILBANK METER ENCLOSURE (MS- 24 -TB) 56. HUBBELL SWITCH (CS1201-1) 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898 -I) 58. SQUARE D LIGHTING CONTACTOR (981 ODPA32VO2UI) 0 0 61. SOUTHCO DOOR S.S. HINGE (F6 -3 -1) o w 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2 -626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1"X.25 GASKET CONTRACTOR IS RESPONSIBLE TO VERIFY METER ARRANGEMENT 16. 2.00 TYP dw 16, ROLL 20 � FR 191 MEETS EUSERC REQUIREMENTS APMovEO BY: PllOET SOUND ENERGY TACOMA POWER JOB NAME: CITY OF RENTON DISTM80110N: CONTRACTOR. PURCHASE ORDER: MATERIAL: .125 5032 -H32 ALUM. COATING TYPE: _ DRAWN SY: MEKKI AL -AZADI HARDWARE: f QU AN T1 TY: FINISH: MILL COLOR: SATE: _OCT 24, 20021 PAGE: OF: �;"� ' '�'= 3 ��► /� Grp SP PAGE: J029 BREAKER SCHEDULE SERVICE VOLTAGE: 120 -240 BUS RATING: Z' Q_AMP MOUNTING: BUS CONNECTION: 2 P 3 W LOCATION DRAWING / NOTES: CURCUIT DESCRIPTION VOLTAMPS BREAKER CKT. NC. CONNECTION A B T_ NO. BREAKER VOLTAMPS A CURCUIT DESCRIPTION A /Wp pO� AMP POLE LIGHTING A 1920 � 20 2 1 20 AMP 2 15 1 1440 � 52. LIGHTING CONTROL 1P 1920 20 3 4 50 1 20 AMP 4soo S"AL LIGHTING B 1920 C.H. 20 15 AMP 5 6 20 1 1920 ENCLOSURE (MS- 24 -TB) RECFRTICAL HURRFII 1920 (CS1201-1) B 2 1920 LIGHTING D LIGHTING C 1920 20 9 10 20 2 1920 1920 11 12 TOTAL 5760 5760 5280 6720 BUS A BUS B TOTAL LOAD COMMENT'S 11044 12480 23520 VA VA VA MAIN BREAKER: 100 AMP LOCATION TOP FEED FEEDER SIZE: souRCE: LINE AMPS: 100 AMP PHASING SINGLE KVA DEMAND: _ _ o o • 51 50 • . 51 r. . • 51 53 • 51 0 49 0 Ibbi e 8 o 0 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898 -I) 58. SQUARE D LIGHTING CONTACTOR (981 0DPA32V02U0 61. SOUTHCO DOOR S.S. HINGE (F6 -3 -1) 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2-626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1"'X-25" GASKET CONTRACTOR IS RESPONSIBLE TO VERIFY METER ARRANGEMENT MEETS EUSERC REQUIREMENTS APPROVED BY: PUGET SOUND ENERGY TACOMA POWER 10.50 -&j MATERIAL: 8 O TYP COATING TYPE: DRAWN BY: MEKKI AL -AZADI 6, 0.75x1.25 TYP HARDWARE: QUANTITY: FINISH: W----?4 COLOR: ' 3. DATE: OCT 24. 200 PAGE: OF: POLE GROUND TERMINAL HAND HOLE ,v #8 BARE COPPER GROUND WIRE 11 1117 N/ 6- #7 BARS #4 HOOPS AT 12 CENTER � II II 1 4 -GALV. STEEL ANCHOR BOLTS � � I LL 0 SIZE TO FIT POLE REQUIREMENT ���\ SECTION A -A WIRE CAGE ION 3' S0. OR RD. � JUNCTION 80X CONCRETE PAD Oy 4" _T 7, _ o" CONDUIT SIZE AS REQUIRED 5/8" x 8' COPPER CLAD METALIC GROUND ROD SIGNAL POLE FOUNDATION Y p� ADOPTED CITY OF RENTON STANDARD PLANS 'P� N IT O� LST DATE: 12/96 DWG. NAME: JR--21 NOTES: 49. 225 AMP COPPER BUSSING 18 PLCS PANNEL 50. C.H. 2P 100 AMP MAIN (BAB2100) 51. C.H. 2P 20 AMP BREAKER (BAB2020) 52. C.H. 1P 50 AMP BREAKER (BAB1050) ' 53. C.H. 1P 20 AMP BREAKER (BAB1020) 54. C.H. 1P 15 AMP BREAKER (BAB1015) 55. MILBANK METER ENCLOSURE (MS- 24 -TB) 56. HUBBELL SWITCH (CS1201-1) 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898 -I) 58. SQUARE D LIGHTING CONTACTOR (981 ODPA32VO2UI) 0 0 61. SOUTHCO DOOR S.S. HINGE (F6 -3 -1) o w 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2 -626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1"X.25 GASKET CONTRACTOR IS RESPONSIBLE TO VERIFY METER ARRANGEMENT 16. 2.00 TYP dw 16, ROLL 20 � FR 191 MEETS EUSERC REQUIREMENTS APMovEO BY: PllOET SOUND ENERGY TACOMA POWER JOB NAME: CITY OF RENTON DISTM80110N: CONTRACTOR. PURCHASE ORDER: MATERIAL: .125 5032 -H32 ALUM. COATING TYPE: _ DRAWN SY: MEKKI AL -AZADI HARDWARE: f QU AN T1 TY: FINISH: MILL COLOR: SATE: _OCT 24, 20021 PAGE: OF: �;"� ' '�'= 3 ��► /� Grp SP PAGE: J029 20A eon NOTES: 49. 225 AMP COPPER BUSSING 18 PLC PANNEL 50. C.H. 2P 100 AMP MAIN (BAB2100) � G 51. C.H. 2P 20 AMP BREAKER (BAB2020) � � 52. C.H. 1P 50 AMP BREAKER (BAB1050) i 53. C.H. 1P 20 AMP BREAKER (BAB1020) o o o o o o o 0 54. C.H. 1P 15 AMP BREAKER (BAB1015) 55. MILBANK METER ENCLOSURE (MS- 24 -TB) 56 HURRFII SWITCH (CS1201-1) o o • 51 50 • . 51 r. . • 51 53 • 51 0 49 0 Ibbi e 8 o 0 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898 -I) 58. SQUARE D LIGHTING CONTACTOR (981 0DPA32V02U0 61. SOUTHCO DOOR S.S. HINGE (F6 -3 -1) 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2-626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1"'X-25" GASKET CONTRACTOR IS RESPONSIBLE TO VERIFY METER ARRANGEMENT MEETS EUSERC REQUIREMENTS APPROVED BY: PUGET SOUND ENERGY TACOMA POWER 10.50 -&j MATERIAL: 8 O TYP COATING TYPE: DRAWN BY: MEKKI AL -AZADI 6, 0.75x1.25 TYP HARDWARE: QUANTITY: FINISH: W----?4 COLOR: ' 3. DATE: OCT 24. 200 PAGE: OF: POLE GROUND TERMINAL HAND HOLE ,v #8 BARE COPPER GROUND WIRE 11 1117 N/ 6- #7 BARS #4 HOOPS AT 12 CENTER � II II 1 4 -GALV. STEEL ANCHOR BOLTS � � I LL 0 SIZE TO FIT POLE REQUIREMENT ���\ SECTION A -A WIRE CAGE ION 3' S0. OR RD. � JUNCTION 80X CONCRETE PAD Oy 4" _T 7, _ o" CONDUIT SIZE AS REQUIRED 5/8" x 8' COPPER CLAD METALIC GROUND ROD SIGNAL POLE FOUNDATION Y p� ADOPTED CITY OF RENTON STANDARD PLANS 'P� N IT O� LST DATE: 12/96 DWG. NAME: JR--21 NOTES: 49. 225 AMP COPPER BUSSING 18 PLCS PANNEL 50. C.H. 2P 100 AMP MAIN (BAB2100) 51. C.H. 2P 20 AMP BREAKER (BAB2020) 52. C.H. 1P 50 AMP BREAKER (BAB1050) ' 53. C.H. 1P 20 AMP BREAKER (BAB1020) 54. C.H. 1P 15 AMP BREAKER (BAB1015) 55. MILBANK METER ENCLOSURE (MS- 24 -TB) 56. HUBBELL SWITCH (CS1201-1) 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898 -I) 58. SQUARE D LIGHTING CONTACTOR (981 ODPA32VO2UI) 0 0 61. SOUTHCO DOOR S.S. HINGE (F6 -3 -1) o w 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2 -626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1"X.25 GASKET CONTRACTOR IS RESPONSIBLE TO VERIFY METER ARRANGEMENT 16. 2.00 TYP dw 16, ROLL 20 � FR 191 MEETS EUSERC REQUIREMENTS APMovEO BY: PllOET SOUND ENERGY TACOMA POWER JOB NAME: CITY OF RENTON DISTM80110N: CONTRACTOR. PURCHASE ORDER: MATERIAL: .125 5032 -H32 ALUM. COATING TYPE: _ DRAWN SY: MEKKI AL -AZADI HARDWARE: f QU AN T1 TY: FINISH: MILL COLOR: SATE: _OCT 24, 20021 PAGE: OF: �;"� ' '�'= 3 ��► /� Grp SP PAGE: J029 M � Ln F.- 0 Q o e CONDUIT SIZE CONDUCTORS W 6PR 12PR N J d- Z o) o TYPE 3 JUNCTION BOX, J -11 a NOTE 1 Cn 2" ; O o I (L • a 1 � 0 0 U _ 4 p 1 o C) 0 Z EX. 2" 1 EX. 1 EX. 1 REMOVE EX. 1--2PR a EX. 4" 1 REMOVE EX. 1 -2PR Q vi Q I w N x r f--- �c 0) O .Q � V) z r V I Q W ( Q 2f Q cD cn •C � C O v) v 4) o- z o U a cy— O CL Q o e CONDUIT SIZE CONDUCTORS W 6PR 12PR N J 2" 1 o) o TYPE 3 JUNCTION BOX, J -11 a NOTE 1 2 2" ; O o M � � o° 1 2" 0 0 � � � •� 4 EX. 2" 1 o C) NOTE 3 a EX. 2" 1 EX. 1 EX. 1 REMOVE EX. 1--2PR a EX. 4" 1 REMOVE EX. 1 -2PR Q w x r �c 0) O 'c E. Q r V • N 3 E 0 CIN •C � C v 4) o- Q o e m Z O V) WIRING SCHEDULE CONDUIT RUN ® CONDUIT SIZE CONDUCTORS W 6PR 12PR 25PR 1 2" 1 o) o TYPE 3 JUNCTION BOX, J -11 a NOTE 1 2 2" 1 O CONSTRUCTION NOTE 2" NOTE 2 3 2" 1 4 EX. 2" 1 EX. 1 NOTE 3 a EX. 2" 1 EX. 1 EX. 1 REMOVE EX. 1--2PR a EX. 4" 1 REMOVE EX. 1 -2PR Q w Q 0 m Z O V) WIRING SCHEDULE CONDUIT RUN ® CONDUIT SIZE CONDUCTORS REMARKS 6PR 12PR 25PR 1 2" 1 o) o TYPE 3 JUNCTION BOX, J -11 a NOTE 1 2 2" 1 O CONSTRUCTION NOTE 2" NOTE 2 3 2" 1 4 EX. 2" 1 EX. 1 NOTE 3 5 EX. 2" 1 EX. 1 EX. 1 REMOVE EX. 1--2PR 6 EX. 4" 1 REMOVE EX. 1 -2PR NOTES: 1. SEE SIGNAL PLANS FOR OTHER CONDUIT AND CONDJCTORS 2. SPARE WITH PULL WIRE 3. OTHER EXISTING CONDUIT AND CONDUCTORS REMAIN = � 3 PORTION OF NW 1/4 OF SEC. 19, T. 23 Nag Re 05 E@9 Wome � or i 5 4 ' 6 - , �' -- _____ UTILITY LOCATES CALL 2 DAYS YOU DIG 1 1- 800 - 424 -5565 1 / 4 00 Willow + O 14 +00 — _ 13 +00 12 +00 _ _ _ ___ —a 1` +OCR - - -- I r- r% r- k i r-% 0—�� SIGNAL STANDARD & LUMINAIRE 0-0 LIGHT STANDARD & LUMINAIRE ❑S INTERCONNECT SPLICE CABINET ® TYPE 1 JUNCTION BOX ® TYPE 2 JUNCTION BOX, J--11 a o) o TYPE 3 JUNCTION BOX, J -11 a Q CONDUIT ® CONTROLLER CABINET O CONSTRUCTION NOTE WIRE NOTE 1 — t LIND AVE. S.W. KIA DEALERSHIP (ASPHALT DRIVEWAY) RMC MOTORSPORTS (ASPHALT DRIVEWAY) 00 w O W + O V) + o) o Q �- -,� 2 `t + —J RMC MOTORSPORTS (ASPHALT DRIVEWAY) 00 O + O 10+ 00 N 9+00 8+00 7+00 6+00 5+00 + o) o Q �- -,� O f--. + —J Q i W —J W ~ (j) U �-- 2 Q �-� ��ONCRETE SIDEWALK 858 LIND AVE. S.W. 858 LIND AVE. .72 (CONCRETE DRIVEWAY) (CONCRETE DRIVEWAY) RMC MOTORSPORTS (ASPHALT DRIVEWAY) GENERAL NOTES �� t CONSTRUCTION NOTES LIND AVE. S.W. 846 LIND AVE. S.W. 2 &T WHOLESALE DISTRIBUTORS ENTRANCE (CONCRETE DRIVEWAY) 1. THE EXISTING PHYSICAL FEATURES SHOWN ON THIS PLAN ARE BASED ON FIELD RECONNAISSANCE BY TP &E: AND ARE NOT SURVEYED LOCAT;ONS. THIS WAS THE INFORMATION AVAILABLE AT THE TIME OF PLAN PREPARATION. THE CON - RACTOR IS ADVISED TO CONDUCT 1 ROUTE INTERCONNECT CABLE INTO CONTROLLER CABINET. FIELD RECONNAISSANCE PRIOR TO BIDDING, AND MAY ENCOUNTER VARIATIONS BETWEEN TERMINATE CABLE AS SHOWN ON THE WIRING DIAGRAM. ACTUAL CONDITIONS AND THOSE SHOWN ON TI-IS PLAN. ANY VARIATION DISCOVERED SHALL NOT BE THE BASIS FOR A CLAIM OR FOR EXTRA COMPENSATION. O ROUTE CONDUIT INTO EXISTING JUNCTION BOX. 2. UTILITIES (ABOVE GROUND OR UNDERGROUND) ARE NOT SHOWN ON THIS PLAN. SOME , 3 ROUTE INTERCONNECT CABLE INTO EXISTING SPLICE CABINET. UTILITIES NEAR S.W. 7TH � >T. ARE SHOWN ON THE TRAFFIC SIGNAL PLAN. THE CONTRACTOR -� TERMINATE AS DIRECTED BY THE CITY. COORDINATE WITH DAVE SHALL DETERMINE THE EXACT LOCATION OF ALL UTILITIES BEFORE COMMENCING WORK. THE WHITMARSH AT 425 - 430 -7423. CONTRACTOR AGREES TO 13E FULLY RESPONSIBLE FOR ALL DAMAGES WHICH MAY RESULT FROM 0 t` + �t- W F— 0 Cn m W _Z W J W V) U F- Q THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ALL UTILITIES. 3. ALL DISTURBED AREAS SHALL BE RESTORED TO THE SATISFACTION OF THE ENGINEER. ; 4+00 0 3+00 2+00 + 846 LIND AVE. S.W. LIND AVE. S.W. �A�ti� 1 &T WHOLESALE DISTRIBUTORS EXIT O�J'�►,,� F� (CONCRETE DRIVEWAY) TRANSPORTATION PLANNING ti 20 0 20 40 appr OX. 5LQ(e_ teet 0 • ROLL 12.0.11 0 & ENGINEERING, INC. °.A 11",s 2223 -112TH AVENUE NORTHEAST, SUITE 101 clsn BELLEVUE, WASMINGTON 98004 'a"'''L E TEL. ( 425) 455-5320 FAX ( 425) 453-5759 (mss s/sros F IR ..192 • O O Oo r- 40 LLB z W J W _ C/) U Q (J') vi 409'? -ro-o 3 / 2 /C 7 0 4