Loading...
HomeMy WebLinkAboutzS-3418Seti� V w [A\� � ° l r � � ti 0 f. 4 - J LL G a s 0 3 i chi a ti w e ® I,,� I. � --- -� V7 -_I `\ �� -- J --- x o - i W Z � - — - - -_z� -- = s -- — w w U -_�_ , _ —�" _- - - - _ - - - -- I � � �iI -- - -- — _ W � � � � w I ' Q U � � j � � ' I Ln z � ji � O — N � I � � / Q I � /% � / / ���� `/ i �' _ NE 5TH CT • Z �� \ ee �' Cis � O I� �'� I! - a I I � -- �� o � _ _ ITT - fl �� � I�� I -M � ��� ._.. II ,.. .. a � > � / x a O a � � o I �� 1- 0 h tl � �' � _ NE 5TH CIR � - Q� � I � .. Z O !Y �BRALSOISK SET /NORI(L IIYY[[ // NIXEINCOh'. -RETE SIREETPERWCLS. z r: _ r ' - Call 2 Working Days Before You Dig 1- 800 - 424 -5555 Utilities Underground Location Center (ID,MT,ND,OR,WA) CAUTION: LOCATION OF E%ISTING UDLRIES SHOWN IS APPROXIMATE AND MAY NDT BE ACCURATE OR ALL INCLUSNE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FlELD VERIFY LOCATION AND DEPTH OF UTILITIES PIBORTO PROCEEDING WIT}) CONSTRUCTION. SURVEY NOTE: EXISRNG SURVEY FEATURES, BOUNOARV AND TOPOGRAPHIC DATA SHOWN OM THESE DRAWINGS HAS BE(ld PREPARED. IN PART, BASED UPON INFORMATION FURNISHED BV OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE. J3AJE CANNOT ENSURE THE ACCURACY AND THUS IS tJOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGSAS A RESULT. WITHIN THE SW 1/4 SEC 11, T 23 N, R 5 E, WM I I I , .. I i — — FzNNOi /4'9I�SSPINON GRAPHIC SCALE a cavcRETE ,NONUMENTBOWNO.TNO _NE 6TH ST CASE Iszo °n 40 0 20 40 (SE 124TH S17 - - - - /" = 40' PROPOSED LEGEND: I E SEWER SERVICE � O SANITARY SEW ER MANHOLE cACCUUrEDPOSmoN PER PUTT _ NE 4TH ST_ 4921x' ,f N89 °0144 "W (BASIS OFBEARlNG) 2609.81' (SE 128TH Sr1 i ® FOUNDMONUMENTINCASE BENCHMARKANDDATUM: SET REBAR AND CAP "AXIS 38011° O FOUND REBAR AND CAP AS NOTED C/TYOFRENTON MONUMENTN0:2f03;BROKEN BRASS OISKFLUSH FFE FINISHED FLOOR ELEVATION W/TH CONCRETEATTHE fNTERSEC7fON OF SE 128TH STAND 156TH — � — — AVE SE, AS PUBLISHED /N CITY OF RENTON SURVEYCONTROL � ;T GATE NETWORKMONUMEN75&BENCHMARKS. SEWER SERVICE W —D DITCH LINE VERTICAL DATUM; NAUD'88 SS SS SANITARY SEWER LINE ELEVATION: 547.94' Q SD SD STORM DRAIN LINE TEMPORARY BENCHMARK.' � I P P POWER LINE — OP -OT O.H. POWER AND TELECOMM. RAILROAD SPIKE UP I.O'ON THE WESTS /DE OF POWER POLELOCATEO h AT THE SOUTHWEST CORNER OFL0T3. r' W W WATER LINE ELEVATION.' S18.9T G G GAS LINE —X —X X_ I(� CLF CHAIN LINK FENCE LINE I .. .+ WDF WOOD FENCE LINE TABLE OF CONTENTS: --- - -- --- SEWER FORCE MAIN p COVER SHEET --------- - - - - -- SAWCUT LINE 2 SANITARY SEWER EXTENSION D3 NOTES & DEYAILS CONCRETE PAVING 4 MOTESB DETAILS LI ASPHALT PAVING NOTES.• NOABSTRACTOFTITLE, NOR TITLE COMMITMENT, OR RESULTS OFA BUILDINGS TITLESEARCHWERE FURNISHED TO THESURVEYOR. DOCUMENTS OF RECORD MAYEX/ STWH /CHAFFECTTHESUBJECTPROPERTY. GRAVEL SURFACE NO EASEMENTS. RESTR/CT/ONS, OR RESERUAT/ONS OFRECORD WH /CH WOULD BE DISCLOSED BYTITLE REPORTARE SHOWN. THE 1NFORMATIONOEP/CTED ONTHIS MAPREPRESENTS THE RESULTS OFASURVEY CONCLUDED ON JUNE 19,2007ANDCAN ONLYBE S`� J• ✓� CONSIDEREDAS INDICATING 7HEGENERAL CONDITIONS EXISTlNGAT y Adyq THAT T /ME R�' q '�o EVIDENCE OFLAND OCCUPAT /ON SUCHAS FENCES, STRUCTURES, PAVED OR GRAVELED SURFACES, LANDSCAPING; ETC. MAYNOT I COINCIDE WITH THE DEEDED BOUNDARYLINES, AS SHOWN ON THIS DRAWING THEREAREAREAS ONTHIS SURVEYAPPEAR/NG.TO HAVE �t..� DISCREPgNCIES BETWEENTHEDEEDED 80UNDARYLINESAND I CERTA /N EVIDENCE OFOCCUPATION. AXIS RECOMMENDS THAT THE --y IUNAT.�` /abl0� WHEREVER D�SCREP.ANC /ES EX STT ODETERM/NIEHOWSESOUONSEL EXPIRES 07�14�08. INTERPRET THEIR PROPERTYRIGHTS ANDAG7ORESS POTENTIAL @DUNDARYD /SPUTES. RECOMMENDED FOR APPROVAL .UNDERGROUND UTILITIES WERE LOCATED BASED ON THESURFACE EV/OENCEOF UT1L /TIES (PAlN7MARKS, SAWCUTS IN PAVEMENT, BY DATE.' COVERS, LIDS, ETC): THECONTRACTOR SHALL VERIFYTHE EXACT LOCATION, EGEVAT /ONAND SIZE OF EXISTING UTILITIES PRIOR TO BY DATE.' CONSTRUCTION. ' INSTRUMENTAT /ON FOR THIS SURVEYWASALE/CA 1103 TOTAL BY DATE: STATION. PROCEDURES USED IN THIS SURVEYWEREFIELD TRAVERSE, MEETING OR EXCEEDING STANDARDS SETBYWAC 332 - 130-090. BY DATE' BY Dare REFERENCES: I KING COUNTYASSESSORSMRP FOR THE SW V4, SEO 11, TWP. 23N, RGE. 05E., W.M. .a i ®i ASSESSORSPCATOFWH /TE FENCE RANCH, RECORDED IN VOLUME 65, PAGE 6, RECORDS OFKING COUNTY, WASHINGTON. V BRassDlsrcserwvRnL — _ — � HOLEMICQNCRETE SR:EETPERWCCB. NAVD '88 CV1HC1001 SHT 1 OF � CD -S -��1 �NAIEp �C4$?atti/ i� � � s .. - � s �°a I • � �."� - - NE 10TH Sf ISE 116tH 5T) N NE ofH � </ /`sE exam / COALFIELD � s x n S! sn PARK ®� ®o® E aTH sr Ise 1zarH sT) VlC/NITYMAP -- � - cACCUUrEDPOSmoN PER PUTT _ NE 4TH ST_ 4921x' ,f N89 °0144 "W (BASIS OFBEARlNG) 2609.81' (SE 128TH Sr1 i ® FOUNDMONUMENTINCASE BENCHMARKANDDATUM: SET REBAR AND CAP "AXIS 38011° O FOUND REBAR AND CAP AS NOTED C/TYOFRENTON MONUMENTN0:2f03;BROKEN BRASS OISKFLUSH FFE FINISHED FLOOR ELEVATION W/TH CONCRETEATTHE fNTERSEC7fON OF SE 128TH STAND 156TH — � — — AVE SE, AS PUBLISHED /N CITY OF RENTON SURVEYCONTROL � ;T GATE NETWORKMONUMEN75&BENCHMARKS. SEWER SERVICE W —D DITCH LINE VERTICAL DATUM; NAUD'88 SS SS SANITARY SEWER LINE ELEVATION: 547.94' Q SD SD STORM DRAIN LINE TEMPORARY BENCHMARK.' � I P P POWER LINE — OP -OT O.H. POWER AND TELECOMM. RAILROAD SPIKE UP I.O'ON THE WESTS /DE OF POWER POLELOCATEO h AT THE SOUTHWEST CORNER OFL0T3. r' W W WATER LINE ELEVATION.' S18.9T G G GAS LINE —X —X X_ I(� CLF CHAIN LINK FENCE LINE I .. .+ WDF WOOD FENCE LINE TABLE OF CONTENTS: --- - -- --- SEWER FORCE MAIN p COVER SHEET --------- - - - - -- SAWCUT LINE 2 SANITARY SEWER EXTENSION D3 NOTES & DEYAILS CONCRETE PAVING 4 MOTESB DETAILS LI ASPHALT PAVING NOTES.• NOABSTRACTOFTITLE, NOR TITLE COMMITMENT, OR RESULTS OFA BUILDINGS TITLESEARCHWERE FURNISHED TO THESURVEYOR. DOCUMENTS OF RECORD MAYEX/ STWH /CHAFFECTTHESUBJECTPROPERTY. GRAVEL SURFACE NO EASEMENTS. RESTR/CT/ONS, OR RESERUAT/ONS OFRECORD WH /CH WOULD BE DISCLOSED BYTITLE REPORTARE SHOWN. THE 1NFORMATIONOEP/CTED ONTHIS MAPREPRESENTS THE RESULTS OFASURVEY CONCLUDED ON JUNE 19,2007ANDCAN ONLYBE S`� J• ✓� CONSIDEREDAS INDICATING 7HEGENERAL CONDITIONS EXISTlNGAT y Adyq THAT T /ME R�' q '�o EVIDENCE OFLAND OCCUPAT /ON SUCHAS FENCES, STRUCTURES, PAVED OR GRAVELED SURFACES, LANDSCAPING; ETC. MAYNOT I COINCIDE WITH THE DEEDED BOUNDARYLINES, AS SHOWN ON THIS DRAWING THEREAREAREAS ONTHIS SURVEYAPPEAR/NG.TO HAVE �t..� DISCREPgNCIES BETWEENTHEDEEDED 80UNDARYLINESAND I CERTA /N EVIDENCE OFOCCUPATION. AXIS RECOMMENDS THAT THE --y IUNAT.�` /abl0� WHEREVER D�SCREP.ANC /ES EX STT ODETERM/NIEHOWSESOUONSEL EXPIRES 07�14�08. INTERPRET THEIR PROPERTYRIGHTS ANDAG7ORESS POTENTIAL @DUNDARYD /SPUTES. RECOMMENDED FOR APPROVAL .UNDERGROUND UTILITIES WERE LOCATED BASED ON THESURFACE EV/OENCEOF UT1L /TIES (PAlN7MARKS, SAWCUTS IN PAVEMENT, BY DATE.' COVERS, LIDS, ETC): THECONTRACTOR SHALL VERIFYTHE EXACT LOCATION, EGEVAT /ONAND SIZE OF EXISTING UTILITIES PRIOR TO BY DATE.' CONSTRUCTION. ' INSTRUMENTAT /ON FOR THIS SURVEYWASALE/CA 1103 TOTAL BY DATE: STATION. PROCEDURES USED IN THIS SURVEYWEREFIELD TRAVERSE, MEETING OR EXCEEDING STANDARDS SETBYWAC 332 - 130-090. BY DATE' BY Dare REFERENCES: I KING COUNTYASSESSORSMRP FOR THE SW V4, SEO 11, TWP. 23N, RGE. 05E., W.M. .a i ®i ASSESSORSPCATOFWH /TE FENCE RANCH, RECORDED IN VOLUME 65, PAGE 6, RECORDS OFKING COUNTY, WASHINGTON. V BRassDlsrcserwvRnL — _ — � HOLEMICQNCRETE SR:EETPERWCCB. NAVD '88 CV1HC1001 SHT 1 OF � CD -S -��1 �NAIEp �C4$?atti/ i� � � s .. - � s �°a I • � �."� - - i ®� ®o® SEWER MAIN SEWER SERVICE VlC/NITYMAP -- � - � - - -- ,/ / ���' - �`° SAWCUT LINE ASPHALT PAVING (NOT TO SCALE) GENERAL NOTES DEVELOPER.' NIGGARD CONSTRUCT /ON P.O. BOX 1696 I SURVEYLEGEND: ISSAQUAH, WASHINGTON 98027 425�H64 -6924 CONTACT.' ADAld NIGGARD -ii POWER POLE WNNDERGROUND CONDUIT AND TRANSFORMER ENGINEER: J3ME � ' �—� POWER POLE W /TRANSFORMER 1375NWMALL ST., SU/TE3 ISSAQUAH, WASHINGTON 98027 - '- � - i - , „ �- AND LIGHT POWf7i POLE W /TRANSFORMER (425) 313 -1078 CONTACT.' JERRITJ. JOLMA, P.E. _ _ _ Q SANITARY SEWER MANHOLE _ ❑ CATCH BASIN SURVEYOR: AX /S SURVEY& MAPPING 13005 NE 126TH - _ - - - -- - _ O SD < R STORM DRAIN CLEANOUT CULVERT FIRE HYDRANT PL K/RKLAND, WA 98034 425823 -5700 CONTACT.�MITCH EVANS, PLS :- r - —� - � � ® N �Q � WATER METER WATER VALVE ROCKERY BASIS OF BEAR /NG Bq5 /S OF BEARINGS NORTH 89 °0144 "WESTALONG SE 128TH ST -' _ _ �( SIGN POST SET BENCHMARK SET HUB AND TACK BETWEEN C/TYOFRENTON MONUMENTS210381852. 'PLATBEAR/NGS WERE ROTATED TO ALIGN WITH NAD'83/91 PER ClTYOF RENTON CONTROL cACCUUrEDPOSmoN PER PUTT _ NE 4TH ST_ 4921x' ,f N89 °0144 "W (BASIS OFBEARlNG) 2609.81' (SE 128TH Sr1 i ® FOUNDMONUMENTINCASE BENCHMARKANDDATUM: SET REBAR AND CAP "AXIS 38011° O FOUND REBAR AND CAP AS NOTED C/TYOFRENTON MONUMENTN0:2f03;BROKEN BRASS OISKFLUSH FFE FINISHED FLOOR ELEVATION W/TH CONCRETEATTHE fNTERSEC7fON OF SE 128TH STAND 156TH — � — — AVE SE, AS PUBLISHED /N CITY OF RENTON SURVEYCONTROL � ;T GATE NETWORKMONUMEN75&BENCHMARKS. SEWER SERVICE W —D DITCH LINE VERTICAL DATUM; NAUD'88 SS SS SANITARY SEWER LINE ELEVATION: 547.94' Q SD SD STORM DRAIN LINE TEMPORARY BENCHMARK.' � I P P POWER LINE — OP -OT O.H. POWER AND TELECOMM. RAILROAD SPIKE UP I.O'ON THE WESTS /DE OF POWER POLELOCATEO h AT THE SOUTHWEST CORNER OFL0T3. r' W W WATER LINE ELEVATION.' S18.9T G G GAS LINE —X —X X_ I(� CLF CHAIN LINK FENCE LINE I .. .+ WDF WOOD FENCE LINE TABLE OF CONTENTS: --- - -- --- SEWER FORCE MAIN p COVER SHEET --------- - - - - -- SAWCUT LINE 2 SANITARY SEWER EXTENSION D3 NOTES & DEYAILS CONCRETE PAVING 4 MOTESB DETAILS LI ASPHALT PAVING NOTES.• NOABSTRACTOFTITLE, NOR TITLE COMMITMENT, OR RESULTS OFA BUILDINGS TITLESEARCHWERE FURNISHED TO THESURVEYOR. DOCUMENTS OF RECORD MAYEX/ STWH /CHAFFECTTHESUBJECTPROPERTY. GRAVEL SURFACE NO EASEMENTS. RESTR/CT/ONS, OR RESERUAT/ONS OFRECORD WH /CH WOULD BE DISCLOSED BYTITLE REPORTARE SHOWN. THE 1NFORMATIONOEP/CTED ONTHIS MAPREPRESENTS THE RESULTS OFASURVEY CONCLUDED ON JUNE 19,2007ANDCAN ONLYBE S`� J• ✓� CONSIDEREDAS INDICATING 7HEGENERAL CONDITIONS EXISTlNGAT y Adyq THAT T /ME R�' q '�o EVIDENCE OFLAND OCCUPAT /ON SUCHAS FENCES, STRUCTURES, PAVED OR GRAVELED SURFACES, LANDSCAPING; ETC. MAYNOT I COINCIDE WITH THE DEEDED BOUNDARYLINES, AS SHOWN ON THIS DRAWING THEREAREAREAS ONTHIS SURVEYAPPEAR/NG.TO HAVE �t..� DISCREPgNCIES BETWEENTHEDEEDED 80UNDARYLINESAND I CERTA /N EVIDENCE OFOCCUPATION. AXIS RECOMMENDS THAT THE --y IUNAT.�` /abl0� WHEREVER D�SCREP.ANC /ES EX STT ODETERM/NIEHOWSESOUONSEL EXPIRES 07�14�08. INTERPRET THEIR PROPERTYRIGHTS ANDAG7ORESS POTENTIAL @DUNDARYD /SPUTES. RECOMMENDED FOR APPROVAL .UNDERGROUND UTILITIES WERE LOCATED BASED ON THESURFACE EV/OENCEOF UT1L /TIES (PAlN7MARKS, SAWCUTS IN PAVEMENT, BY DATE.' COVERS, LIDS, ETC): THECONTRACTOR SHALL VERIFYTHE EXACT LOCATION, EGEVAT /ONAND SIZE OF EXISTING UTILITIES PRIOR TO BY DATE.' CONSTRUCTION. ' INSTRUMENTAT /ON FOR THIS SURVEYWASALE/CA 1103 TOTAL BY DATE: STATION. PROCEDURES USED IN THIS SURVEYWEREFIELD TRAVERSE, MEETING OR EXCEEDING STANDARDS SETBYWAC 332 - 130-090. BY DATE' BY Dare REFERENCES: I KING COUNTYASSESSORSMRP FOR THE SW V4, SEO 11, TWP. 23N, RGE. 05E., W.M. .a i ®i ASSESSORSPCATOFWH /TE FENCE RANCH, RECORDED IN VOLUME 65, PAGE 6, RECORDS OFKING COUNTY, WASHINGTON. V BRassDlsrcserwvRnL — _ — � HOLEMICQNCRETE SR:EETPERWCCB. NAVD '88 CV1HC1001 SHT 1 OF � CD -S -��1 �NAIEp �C4$?atti/ i� � � s .. - � s �°a I • � �."� - - Myy> 0 E 1 4 � h a' I-- i I- WITHIN THE SW 1/4 SEC 11, T 23 N, R 5 E, WM m ! I N I n CONNECT TO EXISTING SSMH PER C.O.R. ST0.5 - - I I VII STA 1- 0487501'RT(THIS PROJECT)_ �` _ - STA 2 +37, S RT (C.O.R PROJECT NO.53327) = F rn SPACE ON WEST FACE n CONTRACTOR SHALL POTHOLEAND VtR1FY 0l SHIN - 1_L PRIOR TO CONSTRUCTION NOP.FYENGMEERAT.'D ' _ OF POWER POLE UP 7.0' Z CITY IF OTHER THAN SHOWN ON THESE DRAWINGS. ((� -- - ;. I = I II EL 518.97' (� Z H - CL z O I 6 °1E= 5122' 6 ' 1E=1�123 6'IE =5724 i 6 'IE =5131' SAWCUT LI i \ NE (IYPJ .. LLJ =-•ljC 0'. _ OP -OT � OP OT P U GP -OT o X --I( -� I O,. 111 -.()T' OP -❑ UP -PT- W LLJ _ .. .._ —5_ '�� SL- .._.__. ... SC, S SD `S S 5., —SD Sly --- � - S S 5�7— L1) ___ Of (n I I STA 1+00.00 BASIS OF STATIONING '.\ `. - \m . \ •\ \, ��, \ \ \�` - \� \ �\ \� •\ ® \\ T� \ -' \ \m \ j. \ ...\ V :..��E \\ \ y w CINTERSECTION NE 6TH ST(SE 124TH ST) 1 \� \\ \ \• \ \ ` \ E\ �\ s155M AVE SE v v a wy- �� v �� ` \' �� v'w a �v4 au v _ _ -- I i •��C \ J, I� �`cs \ `\ \ \_'�� \\ \\ \\ \_\ a...�.•. \\ '�\ \ \ \ �_ \�L� ,\ iR \may LLJ ry e Q \ Q n iQ SSMH # 1 _ I STA. 4+50.23,5.00- RT. - -� I- SIDE S GRAVEL IN ND (TYP.) EWER Q 2 %MIN. KIND 6 "IE= 571.9' p PER DETAIL,SHELTT3. (71'P.) 6 "IE 51 f.5' 6 °IE =511.5 RESTORE THE TRENCH WITH _ ? 5 - MINIMUM OF 6.5 INCHES OF CRUSHED SURFACING MATERIAL AND HMA THE ® ®® I SAME THICKNESS AS ME EXISTING NOTE. F7- 1 2411 ASPHALTPAVEMENT ORA MINIMUM OF FILL AND COMPACT w A ! Plt:nq,�O`; 21NCHES, WHICHEVER IS THE GREATER ROADWA t Y PRISM PRIOR TO CC ,IIG PAVEMENT SHALL THEN BE OVERLAID EXCAVATION FOR THE FULL WIDTH WITH MINIMUM OF I.5 SANITARY SEWER. 0 a a 0 i 0 i — / V 03 1 mm iws 'T T SHADOW AVE NE 14 1 moll 5-1 ST Q- �� a M =1 II a y= :tl cI _ 3 -ate T D. a 525 o_ m 520 515 z 510 >O W —j -- ----1520 I - - 505 INCHES COMPACTED HMA AY AV GRAPHIC SCALE 20 U 10 20 I" = 20' 'a NE 10TH ST IlSE 116TH S<) W N �SE 124TH ST) a COALFIELD PARK 30 5 t JO NE 4-ST w BE 128TH ST) w VICINITY MAP (NOT TO SCALE) BENCHMARKAND DATUM." VERTICAL DATUM. NAVD'88 ELEVATION.' 167.01' TEMPORARYBENCHMARK.' RAILROAD SPIKE UP 1.0'ON THE WEST SIDE OF POWER POLELOCATED AT THE SOUTHWEST CORNER OF LOT 3. ELEVATION: 136.04' I., Call 2 Working Days Before You Dig 1 -800 -424 -5555 Utilities Underground Location Center ID MT ND OR,WA CAUTION: LOCATION OF EXISTING UTILITIES SHOWN IS APPROMMATE AND MAY NOT BE ACCURATE ORALLINCLUSNE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY LOCATION AND DEPTH OF LMUT E' PRIOR TO PROCEEDING WITH CONSTRUCTION. SURVEY NOTE: EXISTING SURVEY FEATURES, BOUNDARY AND TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS: WHILE. THIS INFORMATION IS BELIEVED TO BE RELIABLE ME CANNOT ENSURE THE ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. 525 t JO —j -- ----1520 I - - -- 04 — — — , f -- - - - -�— —�� __. - - --i 515 8 342 �BroNeL � I Zsclbl ' _ 2170 i EXPIRES 07/14/08 1-95 6 "I E50Z87 - JC S S= 0.0858 S I T 510 1 I I RECOMMENDED FOR APPROVAL 1 +g8, s•IE59765 2.1 6 "IE508.36 SSMH #1 HISPROJEC BY , y 3OcJ a7 STA. 4 +5023 5.00'RT 1.505 RIM c fE /0UD -- 508-54 {N) BYj�+✓�� 16 Q By DA . BY DATE. 3 +00 4 +00 5 +00 BY DATE., 155TH AVE. SE SCALE: V= 20' HORIZ. IMAM BY DATE 1" = 5' VERT. SS1HC1001 NAVD '88 S1fT 2 OF 4 C01534180Z , Mow °a4:1'LetiT PR _ � r - - -} a "a w W U, w w � � m 11 � .�7 5 0 3 I— Vr n/ n n/ z LL (n z LJ W J IZ' Q W F wL'i o W LJ cn F LJ CD z F- LC7 Ln Ln Am 44 Q� y3 � N E �oo r - Z a x a o a � „ � 3 O O Z q' L rbr to instnDntbn aF n =nNtary seer ca�,e�5 m, 'rx�m � �� sae - serer per„It ,.,sc be p,rcnnsea srw, the cty aF � ? � Renton Public Vprks Depwtneni z. Types o< ppe ana atta,gs mat can be ...sea for scnitory CASTING INLAND FDRY E 5 shnn be nparwea by me Department of PWilic Works. OR EQUAL. PT. =714 B g a e� we kets ns spa R'l- by the manuFncLUrer, SEAL WITH AR 4000 AND ( SEE DETAIL 5.I.A. HOUSE HOUSE HOUSE HOUSE be �d °" DRY SAND AFTER PATCHING ` 3. A TAN. gratle of 2% Q /4" per I= must be �mb,ea m •pipe. In �ewent a zr. grntle 25' aetraen�ttOO me (?iy nna u,e� � u'nis�nu ,3 - -- ADJUSTMENT 4' MIN. •u r 6' pipe nt c grade of i% CANE lu�lro� aEauWt V + d c" -S5- Slt er, ={R 24 h sFOr inspection 4r�u >wz, s� xczs z �a ana representawe srce .men Mspectotl PATCHED AREA MORTAR JOINTS smm.c FamT s s rues at tea tore. Sae an stun i PRECAST _ ' 3'-0" MIN. �,au be es�°aaa uy Ficnuo, s. 1I per sped • it �a tine lisC: vrtW =tic�l n 1 she house. kts bctar.11 pprovo given br SECTION a °�°� a Pmai apprp «n3 �! be granted after e ex�ing 1 wE T. eve IN J i .� L6, xx " amlrw septic tank tins been „-,mpea opt Pad cored .im snna A A STEPS - 3/4' DEFORMED BAR ? w� s Instaa sae r .tth z N,m, c',elet ,Ie• -'{ i STEPS SHALL BE INCLUDED 1' -0" OUTSIDE DIA. r Is nuo.ea at me MuseiF o shano «. 6-I /C'• G IF sae serer stub is rot .v Pble. The a«ner shall C V E R + 2" AG CLASS •'G" 1 CONCRETE BASE BY PIPE INC., w be respo.smle For its Instnnnaon Tl, We se «er —j rr TYPICAL BUILDING SEWER INSTALLATION PLAN shoat be mw, pf 6•in size. If tee k t 7' MTNt� OR APPROVED EQUAL. a.a awe; tyre s .a,st b ped t„ st rpm sedate. ul r u 4B' �'1 x Tiff BURLYVEa SS lLVFR DW1 TxE ara et r!ght -oF; a{ hall be done by Bcensetl I-4" CONCRETE 1[a(wL enc[ swu nn varN.l.m tpw- ry irua twnaed con rn tor. - 'T 'i _ ..... vrc •. 7. I .ark sHau n =cpmplishea m =praabi - 1P)� e <•� mrPU� Heal {h Act. (WI HA) IntlustNn! Safety a.W . - " MAX PIPE SIZE 21' LD. n cicumur & All trench backfAl For side ex i a 1 LADDER -STD. ALUMINUM lire pow= rlyn-z- of -•ar shah consist of s /e• e a near w OR GALVANIZED STEEL r 77 .T E ° °1PWG 9. All bWNrig sewer and sore sewers shall hove MORTAR i t' - a' b aging m n «orannce wttn drn +lag BWtec ar SECTION A -A FILLET I CONTRETE SHELF z ?; BRdd g avpl(cawe. PRECAST BASE SECTION ' €9 i s wxLw PLAN PLAN OR CAST IN SHELF. $� m+ �m E ui s^ s k °IDC BULDING DRAIN r 6• Li = A�..xx�s. FOR LOW HOUSE n� REMOVE PAVEMENT AND BASE MATERIALS FOR A DISTANCE WHICH IS EQUAL TO THE DIAMETER OF THE FRAME PLUS TWO FEET. ADJUST CASTING FRAME TO PAVEMENT SURFACE USING e� xme s revo! NP1N CONCRETE BLOCKS. g" PLAN REPLACE ALL BUT TOP 2" OF EXCAVATED MATERIAL WITH CL SS 3000 CONCRETE (3/4). FINISH BUILDING SEWER f. fit_ JL INSTALLATION PAVEMENT SURFACE WITH 2" OF A.C. CLASS "G ". SEE CITY OF RENTON SUPPLEMENTAL SPECIFICATIONS SECTION 7- 05.3(1). TYPICAL BUILDING SEWER SANITARYMANHOLE SIDE SEWER (PROPERTY LINE) TO BLDG CONNECTION TYPICAL UTILITY COVERADJUSTMENT TYPICAL DETAIL INSTALLATION PLAN FOR PAVEMENT OR OVERLAY NOT TO SCALE NOT TO SCALE (C0 R. STD. DET41L BR28) (C. 0. R. STD. DETAIL BR35) (C.O.RNOT TO SCALE . STD. DETAIL BR36) PROPERTY LINE CL R/W 3' -0" MIN 6' -0" FUTURE 4- 112" WEB 8 PL 6" BUILDING SEWER PIPE I BUILDING SEWER i /Y' x 3" x 3/8" NGN -SKID PATTERN CAST INTEGRAL ON TGP W STUD SERVICE MARKER PAINT UPPER ° °0 °0 2s -' TEE WITH 6" SIDE OUTLET PORTION - WHITE ANS STENCIL ON SIDE °O�L�O P +•• r1" I Y WARDING 'SEWER' WITH 3" HIGH BLACK LETTERS. 0 3� AND #6 WIRE WRAPPED AROUND THE STUD AND I 6" SIDE SEWER AND BUILDING SEWER 16„ Wa EXTENDED TO THE TOP OF THE STUD. JI a UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST 3/ +„ IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS CAP WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. EXISTING SANITARY SEWER (REMOVE) EXISTING SIDE SEWER VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, D1 PIPE AND C1 SECTION A-A EXISTING 6" SEWER A EQUIRFn — -60" ALLOWABLE MAX. PIPE SEWER MAINS ARE TO BE CORE DRILLE➢ STUB (REMOVE TO R /W) FOR CAST IRON PIPE FRAME (NON - LOCKING) COVER (NON - LOCKING) _�- !\ OR DUCTILE IRON PIPE. FOR 5/8 " -i1 N.C. x 1 -1/4" 6 "x 4" REDUCER CDNCRETE� A S.S. SOD. HD. CAP SCREW (3 REQ'D.) `5/8" 3 /e^ �L2„ 1 �.- 6•• WYE sLOCKING B T 112" TYP. TYP. NON -SKID PATTERN i SEA i J ��' MP NGRE'C I I 1/8 OR 1/16 BEND _ RI 2% MIN SLOPE HORIZONTAL 25" PROPOSED 6" SEWER STUB 6" SIDE OUTLET TEE —I- SEWER MAIN T - o SECTION B -B I-6" MIN. SEWER MAIN 2" RAISED LETTERS AS CONCRETE BLOCKING ANGLE RE 'D. SEE NOTE No. 3 BELOW \ OF TEE AT MAIN OVER 25 TYPICAL SIDE SEWER ELEVATION `MAIN RUN SIZE / 6" TEE ELEVATION UNDERSIDE SHOWN FOR CLARITY 3 /+" CORE (TYP.) ON 23" B.C. NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 5' COVER AT PROPERTY DRILL AND TAP 5 /8" -i1 NL. _/2" CORE<TYP.> (LOCKING) ON 23" B. TA P. 3 PL.) PROPOSED SEWER MAIN LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. FRAME (LOCKING) COVER STANDARD SIDE SEWER NOTES 1. FOR NON - LOCKING USE OLYMPIC FOUNDRY No. MH 30 OR EQUAL. INSTALLATION 2. FOR LOCKING LID USE OLYMPIC FOUNDRY No. MH 30 D/T OR EQUAL, 3, USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), NOT TO SCALE: SANITARY (SPECIFY "SEWER" >, OR WATER (SPECIFY "WATER "). CC. 0.R. STD. DETAIL 8839) MANHOLE FRAME TYPICAL STUB CONNECTION AND COVER FOR SEWER REPLACEMENT NOT TO SCALE NOT TO SCALE RECOMMENDED FOR APPROVAL (CO.R. STD. DETAIL BR29) (CO.R. STD. DETAIL BR33) J. - 4�Io� esy L BY DATE.• BY DA BY DA T• A A 3834 IST law aw3w '0 "R BY DATE: EXPIRES 07/14/08 BY DATE.• NA VD 88 GD1HC 1001 SHE 3 OF 4 FR R I 0 L 0 _ ST L .s' -... YL 0 3 a z 0 z w w cn J � Q iaJ �- 3: W W Ln (n w J cn w CD Ire In @'9 ra �a milli M2 S� 4$ � �? O 5= V) Z �o� • • • BACKFILL MATERIAL W (SEE (SEE NOTE 5) t!!!!1!♦ ♦!.!!!!!. ................ ............l.... CONCRETE Oi!!i!i!ili�� �!QOJilOOi DESIGN) (SEE NOTE 8) -OUNDATION LEVEL (CLASS A NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 957 MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY SEWERS SECTION OF THE STANDARD SPECIFICTATIONS FOR TRENCH WIDTH "W"• AND TRENCHING OPTIONS. THE PIPE ZONE WILL BE THE ACTUAL TRENCH WIDTH. EXCEPT FOR CLASS A BEDDING. THE MINIMUM CONCRETE WIDTH SHALL BE 1 -1/2 I.D. + 18••. W (SEE NOTE 4) LIMITS OF PIPE ZONE 5. TRENCH BACKFILL SHALL CONFORM TO "BACKFIWNG SEWER TRENCHES' IN THE SANITARY SEWERS SECTION OF THE STANDARD SPECIFICAiI0N5, EXCEPT THAT ROCKS BACKFILL MATERIAL OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER SHALL NOT BE USED IN THE (SEE NOTE 5) BACKFILL MATERIAL. BEDDING MATERIAL 6. SEE "BEDDING MATERIAL FOR RIGID PIPE" IN THE AGGREGATES SECTION OF THE FOR RIGID PIPE STANDARD SPECIFICATIONS FOR THE MATERIAL SPECIFICATIONS_ C I (SEE NOTE 6) L 7. SEE "BEDDING MATERIAL FOR FLEXIBLE PIPE" IN THE AGGREGATES SECTIO< B STANDARD SPECIFICATION FOR THE MATERIAL SPECIFICATIONS. FOUNDATION LEVEL r 8. PIPE MUST BE ANCHORED IN SUCH A MANER AS TO ENSURE FLOW LINE IS MAINTAINED. (CLASS B, C, D, DESIGN) BEDDING FOR RIGID PIPE W (SEE NOTE 4) LIMITS OF PIPE ZONE T.' 0., BEDDING MATERIAL FOR FI FXIBLE PIPE iJ e (SEE NOTE 7) FOUNDATION LEVEL A (CLASS F DESIGN) BEDDING FOR FLEXIBLE PIPE PIPEBEDDING FOR SANITARY SEWER NOT TO SCALE (CO.R. STD. DETAIL 8077) BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B I CLASS D CLASS F cn 4" MIN. 1/4 I.D. 12" MAX. 6" MIN i EL a_ ZERO n B 1/4 O.D. v. v M < a 1 3/4 O.D. 1/2 O.D. 1/8 O.D. � m F � G' y a a a 0 3 a z 0 z w w cn J � Q iaJ �- 3: W W Ln (n w J cn w CD Ire In @'9 ra �a milli M2 S� 4$ � �? O 5= V) Z �o� • • • BACKFILL MATERIAL W (SEE (SEE NOTE 5) t!!!!1!♦ ♦!.!!!!!. ................ ............l.... CONCRETE Oi!!i!i!ili�� �!QOJilOOi DESIGN) (SEE NOTE 8) -OUNDATION LEVEL (CLASS A NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 957 MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY SEWERS SECTION OF THE STANDARD SPECIFICTATIONS FOR TRENCH WIDTH "W"• AND TRENCHING OPTIONS. THE PIPE ZONE WILL BE THE ACTUAL TRENCH WIDTH. EXCEPT FOR CLASS A BEDDING. THE MINIMUM CONCRETE WIDTH SHALL BE 1 -1/2 I.D. + 18••. W (SEE NOTE 4) LIMITS OF PIPE ZONE 5. TRENCH BACKFILL SHALL CONFORM TO "BACKFIWNG SEWER TRENCHES' IN THE SANITARY SEWERS SECTION OF THE STANDARD SPECIFICAiI0N5, EXCEPT THAT ROCKS BACKFILL MATERIAL OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER SHALL NOT BE USED IN THE (SEE NOTE 5) BACKFILL MATERIAL. BEDDING MATERIAL 6. SEE "BEDDING MATERIAL FOR RIGID PIPE" IN THE AGGREGATES SECTION OF THE FOR RIGID PIPE STANDARD SPECIFICATIONS FOR THE MATERIAL SPECIFICATIONS_ C I (SEE NOTE 6) L 7. SEE "BEDDING MATERIAL FOR FLEXIBLE PIPE" IN THE AGGREGATES SECTIO< B STANDARD SPECIFICATION FOR THE MATERIAL SPECIFICATIONS. FOUNDATION LEVEL r 8. PIPE MUST BE ANCHORED IN SUCH A MANER AS TO ENSURE FLOW LINE IS MAINTAINED. (CLASS B, C, D, DESIGN) BEDDING FOR RIGID PIPE W (SEE NOTE 4) LIMITS OF PIPE ZONE T.' 0., BEDDING MATERIAL FOR FI FXIBLE PIPE iJ e (SEE NOTE 7) FOUNDATION LEVEL A (CLASS F DESIGN) BEDDING FOR FLEXIBLE PIPE PIPEBEDDING FOR SANITARY SEWER NOT TO SCALE (CO.R. STD. DETAIL 8077) y , • SANITARY SEWER NOTES & SPECIFICATIONS 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 6. PLANS APPROVED BY THE CITY OF RENTON. PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 7. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 8. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 9. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 10. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT STANDARDS. 11. DATUM SHALL BE CITY OF RENTON, 1988 NAVD. 12. ALL DISTURBED AREAS SHALL BESE ,-DED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ONSITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 13. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7 OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE 80 THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 14. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50. 15. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 61NCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. gZR J. JO oY wAS L m 3834 WOfST EXPIRES 07/14/08(/ �/ l RECOMMENDED FOR APPROVAL BY DATE.• BY DA BY DATE: BY DATE.• BY DATE: NAVD '88 SHT 4 OF e BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B CLASS C CLASS D CLASS F A 4" MIN. 1/4 I.D. 12" MAX. 6" MIN 6" MIN ZERO G" MIN B 1/4 O.D. 1/2 O.D. 1/8 O.D. ZERO O.D. C 3/4 O.D. 1/2 O.D. 1/8 O.D. TO .D. — y , • SANITARY SEWER NOTES & SPECIFICATIONS 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 6. PLANS APPROVED BY THE CITY OF RENTON. PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 7. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 8. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 9. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 10. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT STANDARDS. 11. DATUM SHALL BE CITY OF RENTON, 1988 NAVD. 12. ALL DISTURBED AREAS SHALL BESE ,-DED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ONSITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 13. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7 OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE 80 THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 14. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50. 15. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 61NCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. gZR J. JO oY wAS L m 3834 WOfST EXPIRES 07/14/08(/ �/ l RECOMMENDED FOR APPROVAL BY DATE.• BY DA BY DATE: BY DATE.• BY DATE: NAVD '88 SHT 4 OF e