HomeMy WebLinkAboutW-358209PROPOSED SAMPLE LINES FROM
PRE -AND POST-SAMPLE TAPS.
CEDAR RIVER PARK WELL PW -9
PROPOSED SAMPLE LINE
NOT TO SCALE
CONNECT PROPOSED 2 CONDUCTOR
SHIELDED CABLES FROM PROPOSED
CHLORINE ANALYZERS TO EXISTING
TERMINAL BLOCKS 133,134,136 AND 137.
EXISTING DISTRIBUTION PANEL
RELOCATE EXISTING WALL FURNISHINGS
AS NEEDED TO MOUNT ANALYZERS.
COORDINATE WITH CITY REGARDING
LOCATION OF ANALYZERS AND
RELOCATED WALL FURNISHINGS.
PROPOSED INSTRUMENTATION CONDUIT
TO JUNCTION BOX, TYP.
PROPOSED POWER CONDUIT TO PROPOSED
JUNCTION BOX, TYP.
PROPOSED CHLORINE ANALYZERS. INSTALL
PER MANUFACTURER'S INSTRUCTIONS.
DIRECT OUTPUT OF PROPOSED
CHLORINE ANALYZER DRAIN LINE
TOWARDS EXISTING FLOOR DRAIN
v
CEDAR RIVER PARK WELL PW -9 EXISTING DISTRIBUTION
PANEL AND PROPOSED CHLORINE ANALYZER
CEDAR RIVER PARK WELL PW -9 EXISTING TELEMETRY PANEL
EXISTING TELEMETRY PANEL "RTU ". CONNECT (2)
PROPOSED 2 CONDUCTOR SHIELDED CABLES FROM
PROPOSED CHLORINE ANALYZERS TO EXISTING
TERMINAL BLOCKS 133,134,136 AND 137. REWIRE
EXISTING ANALOG INPUT WIRES BETWEEN TERMINAL
BLOCKS AND EXISTING ANALOG INPUT CARDS AS
NECESSARY FOR A SOURCED ANALOG INPUT.
CEDAR RIVER PARK WELL PW -9 EXISTING FLOOR DRAIN
PROPOSED CHLORINE
ANALYZERS AND MANUAL
SAMPLE STATION
PROPOSED b GRS POWER CONDUIT
CONTAINING (2) - #12, (1) - #12 GND
THHN CONDUCTORS
PROPOSED
JUNCTION BOX
_I
I
PROPOSED % " GRS INSTRUMENTATION
CONDUIT FROM PROPOSED CHLORINE
ANALYZER TO EXISTING TELEMETRY
PANEL CONTAINING (2) - 2 CONDUCTOR
SHIELDED CABLE
PROPOSED % " GALVANIZED RIGID
STEEL (GRS) POWER CONDUIT FROM
PROPOSED CHLORINE ANALYZER TO
EXISTING DISTRIBUTION PANEL
CONTAINING (2)-#12, (1)- #12GND
THHN CONDUCTORS.
PROPOSED SAMPLE LINES FROM SAMPLE
TAPS. SEE SITE PLAN FOR CONTINUATION.
CONNECTION OF SAMPLE LINE TO CHLORINE
ANALYZER SIMILAR TO DETAIL ep
D22
ROUTE SAMPLE LINES OVER MCCs WITHIN 3"
PVC CONDUIT WITH LONG RADIUS BENDS
PROPOSED CHLORINE ANALYZER DRAIN LINE.
ROUTE DRAIN TO EXISTING FLOOR DRAIN, SECURE
DRAIN LINE TO FLOOR. CONNECTION OF DRAIN
LINE TO CHLORINE ANALYZER SIMILAR TO DETAIL
A
D22
PROPOSED i" GRS POWER CONDUIT
CONTAINING (2) - #12, (1) - #12 GND THHN
CONDUCTORS r
PROPOSED 34" GRSINSTRL
CONDUITS CONTAINING (1
2 CONDUCTOR SHIELDED
LOCATION OF DISTRIBUTION PANEL "DP"
EXISTING MOTOR CONTROL CENTER.
CONNECT PROPOSED CHLORINE
ANALYZER TO EXISTING SPARE 20A
CIRCUIT BREAKER # 10 IN EXISTING
DISTRIBUTION PANEL.
EXISTING 8" HDPE
CHEMICAL CONDUIT
i
ID
"., .... :AIN
CEDAR RIVER PARK WELL PW -9 PLAN VIEW Y Y
1/2 " =1.
REVISED TO CONFORM
TO CONSTRUCTION RECORDS D
0
9/23/13 Q
RH2 ENGINEERING INC. DATE v RENSED TO CONFORM TO CONSTRUCTION RECORDS
NO. REVISION
209
LLC 'MP 9123/1.
REVIEW BY REE DATE
SIGNS& 11/13/12
SIGNER 11/1x112
♦ (r�L
J
Q
v
H
V
1►
C;; w
M' w
W w
3O w
rw,
Z� Q
a
W °•� w
�3�.Zg
IX LU
06 Z pa
�aop-
U Inc
-i Q as
Lu
W
a
oc
a
O
w
U
ENGINEER S
PLANNERS
SCIENTISTS
RH2 ENGINEERING, INC.
h Hp: / /""wrh2,com
ramlbaxQQLC= 1.800.720.8052
BELLINGHAM 38o6/6.0836
454 West Horton Road
BOTHELL <zsssrsaoo
22722 29th Drive SE, Suite 210
EAST
WENATCHEE 5os.sas.2e00
300 Simon Street, Suite 5
RICHLAND sossassrei
114 Columbia Point Drive, Suite C
SILVERDALE 3"876.7960
2021 NW Mhyre Rd, Suite 107
TACOMA 2x 2723059
621 Pacific Avenue Suite 104
DRAWNG IS NOT TO SCALE
IF BAR IS NOT 2" 1011C
Rai: 1
ONO NO
ENO NM ZLB
D16
ISNEME6 CMR
D "'E: Sep 26, 2013
sNEEETT N0.
wHr REN
m No.: 110-093
/i4