HomeMy WebLinkAboutW-358209PROPOSED SAMPLE LINES FROM PRE -AND POST-SAMPLE TAPS. CEDAR RIVER PARK WELL PW -9 PROPOSED SAMPLE LINE NOT TO SCALE CONNECT PROPOSED 2 CONDUCTOR SHIELDED CABLES FROM PROPOSED CHLORINE ANALYZERS TO EXISTING TERMINAL BLOCKS 133,134,136 AND 137. EXISTING DISTRIBUTION PANEL RELOCATE EXISTING WALL FURNISHINGS AS NEEDED TO MOUNT ANALYZERS. COORDINATE WITH CITY REGARDING LOCATION OF ANALYZERS AND RELOCATED WALL FURNISHINGS. PROPOSED INSTRUMENTATION CONDUIT TO JUNCTION BOX, TYP. PROPOSED POWER CONDUIT TO PROPOSED JUNCTION BOX, TYP. PROPOSED CHLORINE ANALYZERS. INSTALL PER MANUFACTURER'S INSTRUCTIONS. DIRECT OUTPUT OF PROPOSED CHLORINE ANALYZER DRAIN LINE TOWARDS EXISTING FLOOR DRAIN v CEDAR RIVER PARK WELL PW -9 EXISTING DISTRIBUTION PANEL AND PROPOSED CHLORINE ANALYZER CEDAR RIVER PARK WELL PW -9 EXISTING TELEMETRY PANEL EXISTING TELEMETRY PANEL "RTU ". CONNECT (2) PROPOSED 2 CONDUCTOR SHIELDED CABLES FROM PROPOSED CHLORINE ANALYZERS TO EXISTING TERMINAL BLOCKS 133,134,136 AND 137. REWIRE EXISTING ANALOG INPUT WIRES BETWEEN TERMINAL BLOCKS AND EXISTING ANALOG INPUT CARDS AS NECESSARY FOR A SOURCED ANALOG INPUT. CEDAR RIVER PARK WELL PW -9 EXISTING FLOOR DRAIN PROPOSED CHLORINE ANALYZERS AND MANUAL SAMPLE STATION PROPOSED b GRS POWER CONDUIT CONTAINING (2) - #12, (1) - #12 GND THHN CONDUCTORS PROPOSED JUNCTION BOX _I I PROPOSED % " GRS INSTRUMENTATION CONDUIT FROM PROPOSED CHLORINE ANALYZER TO EXISTING TELEMETRY PANEL CONTAINING (2) - 2 CONDUCTOR SHIELDED CABLE PROPOSED % " GALVANIZED RIGID STEEL (GRS) POWER CONDUIT FROM PROPOSED CHLORINE ANALYZER TO EXISTING DISTRIBUTION PANEL CONTAINING (2)-#12, (1)- #12GND THHN CONDUCTORS. PROPOSED SAMPLE LINES FROM SAMPLE TAPS. SEE SITE PLAN FOR CONTINUATION. CONNECTION OF SAMPLE LINE TO CHLORINE ANALYZER SIMILAR TO DETAIL ep D22 ROUTE SAMPLE LINES OVER MCCs WITHIN 3" PVC CONDUIT WITH LONG RADIUS BENDS PROPOSED CHLORINE ANALYZER DRAIN LINE. ROUTE DRAIN TO EXISTING FLOOR DRAIN, SECURE DRAIN LINE TO FLOOR. CONNECTION OF DRAIN LINE TO CHLORINE ANALYZER SIMILAR TO DETAIL A D22 PROPOSED i" GRS POWER CONDUIT CONTAINING (2) - #12, (1) - #12 GND THHN CONDUCTORS r PROPOSED 34" GRSINSTRL CONDUITS CONTAINING (1 2 CONDUCTOR SHIELDED LOCATION OF DISTRIBUTION PANEL "DP" EXISTING MOTOR CONTROL CENTER. CONNECT PROPOSED CHLORINE ANALYZER TO EXISTING SPARE 20A CIRCUIT BREAKER # 10 IN EXISTING DISTRIBUTION PANEL. EXISTING 8" HDPE CHEMICAL CONDUIT i ID "., .... :AIN CEDAR RIVER PARK WELL PW -9 PLAN VIEW Y Y 1/2 " =1. REVISED TO CONFORM TO CONSTRUCTION RECORDS D 0 9/23/13 Q RH2 ENGINEERING INC. DATE v RENSED TO CONFORM TO CONSTRUCTION RECORDS NO. REVISION 209 LLC 'MP 9123/1. REVIEW BY REE DATE SIGNS& 11/13/12 SIGNER 11/1x112 ♦ (r�L J Q v H V 1► C;; w M' w W w 3O w rw, Z� Q a W °•� w �3�.Zg IX LU 06 Z pa �aop- U Inc -i Q as Lu W a oc a O w U ENGINEER S PLANNERS SCIENTISTS RH2 ENGINEERING, INC. h Hp: / /""wrh2,com ramlbaxQQLC= 1.800.720.8052 BELLINGHAM 38o6/6.0836 454 West Horton Road BOTHELL <zsssrsaoo 22722 29th Drive SE, Suite 210 EAST WENATCHEE 5os.sas.2e00 300 Simon Street, Suite 5 RICHLAND sossassrei 114 Columbia Point Drive, Suite C SILVERDALE 3"876.7960 2021 NW Mhyre Rd, Suite 107 TACOMA 2x 2723059 621 Pacific Avenue Suite 104 DRAWNG IS NOT TO SCALE IF BAR IS NOT 2" 1011C Rai: 1 ONO NO ENO NM ZLB D16 ISNEME6 CMR D "'E: Sep 26, 2013 sNEEETT N0. wHr REN m No.: 110-093 /i4