Loading...
HomeMy WebLinkAboutT-3430169EXISTING NEW DESCRIPTION (9-- Cam—" SIGNAL POLE WITH MAST ARM D010113 Ex 0 • TYPE I OR PS POLE POLE OECA f IM, _05-1 EXISTING LUMINAIRE O-0 DECORAIIVE PEDESTRIAN LUMINAIRE 0--0 DECORAIIVE ROADWAY LUMINAIRE DECORATIVE PEDESTRIAN /ROADWAY LUMINAI Cfl SIGNAL CONTROLLER CABINET ® ® ELECTRICAL SERVICE CABINET 011 ITS CABINET SEE NOTES BELOW B a I m 011 JUNCTION BOX TYPE 1, 2, 8 ® 25 —TA VAULT 2" - - -� CONDUIT 5 4" WIRE NOTE SPARE Q CONSTRUCTION NOTE 1 -96 SMFO GENERAL NOTES RACEWAY/ CONDUIT SIZE 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & 1 4 1 SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE 127H 0 SEE NOTES BELOW CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2 2. UTILITY LOCATION (DIAL —A —DIG) PRIOR TO CONSTRUCTION SHALL BE THE 12 c 2" RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT SEE NOTES BELOW 5 4" TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. SPARE 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE 1 -96 SMFO SEE NOTES BELOW 6 ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH 7704NL - 7 PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) RAINIER AVE S, _ 8 456 -2701 PRIOR TO INSTALLA11ON OF METER BASE. 5 — 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR — —� R/W X 240V SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 35' 3 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID SERVICE cc 6 RAINIER AVE S, RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER 1 51.5' CDR STD PLAN #127. 5 3, 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL (M— II —FC) 240V LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED 35' 40' BY THE ENGINEER IN THE FIELD. 7706NL 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE 0 RAINIER AVE S, THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW 53.5' IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. 135W INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL 40' ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE VOIDS PER SPECIAL PROVISIONS. SERVICE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE 8 RAINIER AVE S, ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE 14 +41 53.0' CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY "DECORATIVE" 135W REPRESENTATIVE. (M— II —FC) CONSTRUCTION NOTES Oj CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. ® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. 0 ® SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT. 10 FOR EXISTING JUNCTION BOX REMOVAL /MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. 12 REMOVE EXISTING JUNCTION BOX AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. REMOVE EXISTING UNUSED WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S1" — SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) TIRE NOTES OTES: ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 —#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL —LINE TAPE AND LABELED "CITY OF RENTON ". ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. LUMINAIRE # RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS LUMINAIRE TYPE 1 2" 2 #8 SEE NOTES BELOW 2 2" 4 #8 SEE NOTES BELOW 3 2" 6 #8 SEE NOTES BELOW 4 4" 135W SPARE 5 4" 1 -96 SMFO SEE NOTES BELOW 6 2" 7704NL SEE NOTES BELOW 7 EX. RAINIER AVE S, SEE NOTES BELOW 8 4" EX. 1 -48 SMFO RE —ROUTE 135W LED (M— II —FC) 240V 6' 35' 40' C 7703NL SERVICE #S1 6 RAINIER AVE S, STA 13 +14 51.5' LT "DECORATIVE" 135W LED (M— II —FC) 240V 6' 35' 40' B 7706NL SERVICE OTES: ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 —#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL —LINE TAPE AND LABELED "CITY OF RENTON ". ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. LUMINAIRE # STATION OFFSET LUMINAIRE TYPE LUMINAIRE ARM MOUNTING HEIGHT POLE TYPE CIRCUIT # DECAL # COMMENTS 4 RAINIER AVE S, STA 12 +04 51.5' LT "DECORATIVE" 135W LED (M— II —FC) 240V 6' 35' 40' C 7704NL SERVICE #Si 5 RAINIER AVE S, STA 12 +86 53.5' RT "DECORATIVE" 135W LED (M— II —FC) 240V 6' 35' 40' C 7703NL SERVICE #S1 6 RAINIER AVE S, STA 13 +14 51.5' LT "DECORATIVE" 135W LED (M— II —FC) 240V 6' 35' 40' B 7706NL SERVICE #S1 7 RAINIER AVE S, STA 14 +00 53.5' RT "DECORATIVE" 135W LED (M— II —FC) 240V 6' 35' 40' B 7705NL SERVICE #S1 8 RAINIER AVE S, STA 14 +41 53.0' LT "DECORATIVE" 135W LED (M— II —FC) 240V 12' 35' 40' C 7708N SERVICE #S1 9 RAINIER AVE S, STA 15 +29 53.5' RT "DECORATIVE" 135W LED (M— II —FC) 240V 6' 1 35' 40' C 7707NL SERVICE #S1 P4 SHARED POLE "DECORATIVE" 6OW LED (S— III —FC) 240V 4' 1 14' 40' D 7704NL SERVICE #Si P5 RAINIER AVE S, STA 12 +23 53.5' RT "DECORATIVE" 6OW LED (S— III —FC) 240V 4' 14' 18' D 7710L SERVICE #Si P6 RAINIER AVE S, STA 12 +66 51.5' LT "DECORATIVE" 6OW LED (S— III —FC) 240V 4' 14' 18' D 7709L SERVICE #S1 P7 SHARED POLE "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 40' D 7703NL SERVICE #Si P8 SHARED POLE "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 40' D 7706NL SERVICE #Si P9 RAINIER AVE S, STA 13 +41 53.5' RT "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 18' D 7711L SERVICE #Si P10 SHARED POLE "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 40' D 7705NL SERVICE #Si P11 RAINIER AVE S, STA 14 +65 53.5' RT "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 18' D 7713L SERVICE #S1 P12 RAINIER AVE S, STA 15 +35 42.0' LT "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 18' D 7712L SERVICE #S1 P13 SHARED POLE "DECORATIVE" 60W LED S— III —FC 240V 1 4' 1 14' 1 40' D 7707NL SERVICE #Sl T- 3430169 0 5 10 20 40 60 SCALE IN FEET BID DOCUMENTS AUUENUUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12 -16 -11 11 -14 -11 SURVEYED: KPG P' Fq ft Ill d► RAINIER AVENUE S SR 167 DRAWING NO. 229 O,Z�� of "asN Sy� DRAWN BY: JM � CITY OF RENTON S GRADY WAY TO S(2ND ST PROJECT NO. TED403430 — DESIGN BY: JF FEHR & PEERS 7539thAVRN 2502 Jefferson Ave Public Works Department CHECK BY: JF TRANSPORTATION CONSULTANTS Seek WA 98109 Tacoma, WA 98402 ILLUMINATION AND INTERCONNECT PLAN FED AID NO. CM0167(048) a as a a �� Wl am nvaua �""'� u`� °Oipm""'Q APPRO FOR CONSTRUCTION DATE: NOV 2011 9 eci Tca PROJ MGR: TN s;L "< o :�.0 (20612861640 (253)627 -0720 / FS'SIONAL E. �) 5)s a � o G ;"°°"' "" "' 'Mm BY: DATE: / %/✓ STA 12 +00 TO STA 15 +50 SHEET NO. 229 OF 304 NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DILL01.dwg °^m le Z �y a n Oc G —C �a < -C > .p -c w 0 N O