Loading...
HomeMy WebLinkAboutT-34301700 N 3 0 J s 0 T U 0 i 0 M 0 Ch Lv d m °o N # STATION 1' GRS CONDUIT FROM JUNCTION BOX OFFSET LUMINAIRE TYPE TRANSIT " A-RM ARM "" HEIGHT 'T ` TYPE # # # COMMENTS 10 RAINIER AVE S, STA 15 +70 53.5' LT "DECORATIVE" 135W LED (M- II -FC) 240V 12' 35' 40' B 7714NL SERVICE #S1 11 RAINIER AVE S, STA 16 +60 53.5' RT -DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' B 7715NL SERVICE #S1 12 RAINIER AVE S, STA 16 +58 47.0' LT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' C 7716NL SERVICE #S1 P14 SHARED POLE nme4AVema Bite a o ,,,,,,a,,,,�. .°.,, m,,,,�, �: :emu " (200128E1fi49 (2531627 -0720 "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7714NL SERVICE #S1 P15 RAINIER AVE S, STA 15 +93 53.5' RT "DECORATIVE" SOW LED (S- III -FC) 240V 4' 14' 18' D 7717NL SERVICE #S1 P16 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7716NL SERVICE #S1 P17 SHARED POLE "DECORATIVE" 6OW LED (S- III -FC) 240V 4' 14' 40' D 7715NL SERVICE #S1 13 RAINIER AVE S, STA 17+52 48.5' LT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' B 7718NL SERVICE #S2 14 RAINIER AVE S, STA 18 +17 57.5' RT "DECORATIVE" 135W LED (M- II -FC) 240V 12' 35' 40' C 7719N SERVICE #S2 15 RAINIER AVE S, STA 18 +93 53.0' LT "DECORATIVE" 135W LED (M -II -FC ) 240V 6' 35' 40' C 7720NL SERVICE #S2 16 RAINIER AVE S, STA 19 +66 57.0' RT "DECORATIVE" 135W LED (M- II -FC) 240V 12' 35' 40' B 7721N SERVICE #S2 P18 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7718NL SERVICE #S2 P19 RAINIER AVE S, STA 17 +37 53.3' RT °DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 18' D 7723L SERVICE #S2 P20 RAINIER AVE S, STA 18 +21 51.0' LT "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 18' D 7724L SERVICE #S2 P21 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7720NL SERVICE #S2 P22 RAINIER AVE S, STA 19 +90 53.5' LT "DECORATIVE" 60W LED S- III -FC 240V 4' 14' 18' D 7726L SERVICE #S2 LEGEND EXISTING NEW DESCRIPTION Cam= @oEm— SIGNAL POLE WITH MAST ARM aF�` © • TYPE I OR PS POLE xxx o� EXISTING LUMINAIRE DECORATIVE PEDESTRIAN LUMINAIRE 9­0 DECORATIVE ROADWAY LUMINAIRE --6-� DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE m CONSTRUCTION NOTES SIGNAL CONTROLLER CABINET O CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, ® ELECTRICAL SERVICE CABINET POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL EM ITS CABINET INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, CDR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. M z O m W DI JUNCTION BOX TYPE 1, 2, 8 O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND ® 25 -TA VAULT DOWN EXISTTNG FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. - - -- CONDUIT ® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. 0 WIRE NOTE 01 Q CONSTRUCTION NOTE ® SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITONAL SIGNAL SYSTEM EQUIPMENT. 12 REMOVE EXISTING JUNCTION BOX AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. REMOVE EXISTING UNUSED WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. 14 INSTALL 1' GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION. 17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS ". Z INUMBERI REVISION DESCRIPTION JJA I JF BY I APP.I DATE 11 -14 -11 WIRE NOTES ®RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS 1 2" 2 #8 SEE NOTES BELOW 2 2" 4 #8 SEE NOTES BELOW 3 2" 6 #8 SEE NOTES BELOW 4 4" SPARE 5 4" 1 -96 SMFO SEE NOTES BELOW 6 2" SEE NOTES BELOW 7 EX. DOCUMENTS SEE NOTES BELOW 8 4" EX. 1 -48 SMFO RE -ROUTE AL CITY OF RENTON RAINIER AVENUE S (SR 167) DRAWING NO. 230 S GRADY WAY TO S 2ND ST PROJECT NO. IE0403430 DESIGN BY: JF FEHR & PEERS 7539th AveN 2502 Jefferson Ave Public Works Department CHECK BY: JF TRANSPORTATION CONSULTANTS Seattle, WA 98109 Tacoma, WA 98402 ILLUMINATION AND INTERCONNECT PLAN NOTES: 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 -#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL -LINE TAPE AND LABELED "CITY OF RENTON ". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. T- 3430110 GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456 -2701 PRIOR TO INSTALLATION OF METER BASE. 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER COR STD PLAN #127. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY REPRESENTATIVE. 0 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE 1 PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. z �ya n /y a O 09 < � W o w N O 0 5 10 20 40 60 BID SCALE IN FEET DOCUMENTS SURVEYED: DRAWN BY: KPG JIM Kp� AL CITY OF RENTON RAINIER AVENUE S (SR 167) DRAWING NO. 230 S GRADY WAY TO S 2ND ST PROJECT NO. IE0403430 DESIGN BY: JF FEHR & PEERS 7539th AveN 2502 Jefferson Ave Public Works Department CHECK BY: JF TRANSPORTATION CONSULTANTS Seattle, WA 98109 Tacoma, WA 98402 ILLUMINATION AND INTERCONNECT PLAN FED AID NO. CM01671048) PROJ MGR: TN nme4AVema Bite a o ,,,,,,a,,,,�. .°.,, m,,,,�, �: :emu " (200128E1fi49 (2531627 -0720 APPR FOR CONSTRUCTION DATE: _NOV 2011 FILE: 0655DILL01.dwg �tft WA Mw � )slu4= G �m �` a ".° wAw.kpg.cem BY: DATE /j0/4 STA 15 +50 TO STA 20 +00 SHEET NO. 230 OF 304 z �ya n /y a O 09 < � W o w N O