Loading...
HomeMy WebLinkAboutT-3430171O M N w w x O O O N Q H !n w Z J x U H Q I uuu A IM P^lIP -Ml11r __ —.___ 3 SHEET 238) RE MOUNTING HEIGHT POLE TYPE CIRCUIT # DECAL # 1 COMMENTS 2 #8 SEE NOTES BELOW 2 2" * * A 7725N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN 5 * * A 7728N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN SEE NOTES BELOW * * A - * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN * * A 773ON * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN * * A 7727N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN * * A - * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN 35 40' B 7732NL SERVICE #S2 35' 40' C 7729NL SERVICE #S2 35' 40' B 7731NL SERVICE #S2 35' 40' B 7736NL SERVICE #S2 35' 40' C 7734NL SERVICE #S2 14' 18' D 7733L SERVICE #S2 14' 40' D 7732NL SERVICE #S2 ' 40' D 7729NL SERVICE #S2 14' 40' D 7731 N SERVICE #S2 L14 14' 18' D 7736NL SERVICE #S2 14' 40' D 7734NL SERVICE S2 N M N w w x N O U7 N Q F– !n w Z J x U F– Q WIRE NOTES ®RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS 1 2" 2 #8 SEE NOTES BELOW 2 2" 4 #8 SEE NOTES BELOW 3 2" 6 #8 SEE NOTES BELOW 4 4" SPARE 5 4" 1 -96 SMFO SEE NOTES BELOW 6 2" SEE NOTES BELOW 7 EX. SEE NOTES BELOW 8 4" EX. 1 -48 SMFO RE —ROUTE NOTES: 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 —#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL —LINE TAPE AND LABELED "CITY OF RENTON ". 2 _ _ _ _ _ — — 2 — — — ` B1 13 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, R& EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE 1 5 cc —� \ R�W� \ "psi ♦ CONSTRUCTION NOTES FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & LEGEND CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, \ _ � � � �r� � t O SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE EXISTING Nu DESCRIPTION � � 5 13 \ POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. cc \ INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE �� SIGNAL POLE WI1H MAST ARM ♦ ♦ PROVISIONS. RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT ma6L� o • TYPE I OR PS POLE QSERVICE "S2" ♦ ♦ Q REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. ��„f DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE xxxx ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH EXISTING LUMINAIRE \ 18 SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) DECORATIVE PEDESTRIAN LUMINAIRE V1 SEE SIGNAL PLAN ♦ Q CONSTRUCT FOUNDATION PER DETAILS ON SHEET 263 AND FURNISH AND INSTALL ELECTRICAL SERVICE CABINET PER CDR STD 456 -2701 PRIOR TO INSTALLATION OF METER BASE. ♦ FOR DETAI DWGS J010 AND J011 WITH BACK -TO -BACK BATTERY BACKUP SYSTEM PER SPECIAL PROVISIONS. FOR LOCATION AND PANEL LS 4. THE LOCATION OF ALL FEATURES 70 BE INSTALLED BY THE CONTRACTOR p--� DECORATIVE ROADWAY LUMINAIRE \� SCHEDULE, SEE ILLUMINATION CIRCUIT DIAGRAM AND DETAILS SHEET 238. COORDINATE CONNECTION DETAILS TO THE POWER SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. ♦ SOURCE WITH THE POWER COMPANY REPRESENTATIVE PRIOR TO INSTALLATION OF FOUNDATION. SEE SPECIAL PROVISIONS. 5. ALL NEW JUNC11ON BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT UDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER DECORATIVE PEDESTRIAN/ROADWAY LUMINAIRE 8 \ \ ® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. CDR STD PLAN 27. ® m SIGNAL CONTROLLER CABINET 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL Q LUMINAIRE TO BE PART OF A SIGNAL SYSTEM. APPLY DECAL NUMBERING TO POLE, FOR ADDITIONAL INSTALLATION DETAILS SEE \ 5 LOCARONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED 1= CEI ELECTRICAL SERVICE CABINET ♦ SIGNAL PLANS. BY THE ENGINEER IN THE FIELD. 0 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE DID ITS CABINET 1 THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). g, 2 m p 0 JUNCTION BOX TYPE 1, 2, 8 IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL 21 CUT EXISTING 48- STRAND SMFO IN MANHOLE AND PULL THROUGH NEW 4" INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. Q O7 EXISTING SIGNAL POLE MOUNTED LUMINAIRE. FOR REMOVAL NOTES SEE SIGNAL PLANS. T=3430171 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN 25 -TA VAULT CONDUIT TO 25 -TA BOX ON SOUTHEAST CORNER USING SLACK FROM THE WEST. © 10 ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE - - -- CONDUIT PULL EXISTING 48- STRAND SMFO TO THIS MANHOLE FROM MANHOLE ON SOUTHWEST FOR EXISTING JUNCTION BOX REMOVAL /MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE CORNER AFTER IT HAS BEEN CUT. RE -PULL EXISTING 48- STRAND SMFO THROUGH ZONE AROUND EXISRNG AERIAL PRIMARY POWER LINES DURING THE WIRE NOTE 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY 0 NEW 4" CONDUIT TO 25 -TA BOX ON SOUTHEAST CORNER. REPRESENTATIVE. Q CONSTRUCTION NOTE INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF 14 TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION. BID 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE PREPARATION RON PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING CONNECT NEW 4" CONDUIT INTO EXISTING PFL COMMON MANHOLE. CONTACT JOE BANGAH (360 NETWORKS AT IF NECESSARY TO MAINTAIN CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. 18 ) DOCUMENTS 206 - 239 -4012 OR 206 - 612 -1073 TO COORDINATE WORK. ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 1 12 -16 -11 1 11 -14 -11 SURVEYED: KPG oZ? o wAFq oyy DRAWN BY: JM fii Kph CITY OF RENTON RAINIER AVENUES (SR 167) DRAWING NO. 231 S GRADY WAY TO S 2ND ST PROJECT NO. IED403430 DESIGN BY: JF Public Works Department F E H R ST_ PEERS 753 91h Ave N 2502 Je6erson Ave P CHECK BY: JF TRANSPORTATION CONSULTANTS Sea61e, WA 98109 Tacoma, WA 98402 FED AID NO. CM0167(048) 46 4 0 �� =14MAau" � "GU .��.G APP DFORCONSTRUCTION ILLUMINATION AND INTERCONNECT PLAN 9n eci rEaE d4' PROJ MGR: TN WW Otto �,> ,`m, u °G (2061286'1640 (253)627 -0120 DATE: NOV 2011 /0 AL ENG\ SeWO WA salsa �a �, yAVW,k cam �� SHEET NO. 231 OF 304 NUMBER REVISION DESCRIPTION BY APP. DATE FILE:0655DILL01.dwg lzosl57c -4zzo :r.,,, „,” .� P9' BY: DATE: 7.2 STA 20 +00 TO STA 24 +50 a a z `m a a m O � I G v n � a v w a o O N