HomeMy WebLinkAboutT-3430172LEGEND
EXISTING
NEW
DESCRIPTION
OFFSET
LUMINAIRE TYPE
SIGNAL POLE WITH MAST ARM
Lx O
®
TYPE I OR PS POLE
CIRCUIT
#
DECAL
#
COMMENTS
�o
RAINIER AVE S,
EXISTING LUMINAIRE
24 +77
53.5'
DECORATIVE PEDESTRIAN LUMINAIRE
"DECORATIVE"
9--0
DECORATIVE ROADWAY LUMINAIRE
(M- II -FC)
--6
6'
DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE
40'
m
SIGNAL CONTROLLER CABINET
SERVICE
®
ELECTRICAL SERVICE CABINET
RAINIER AVE S,
FIT1
ITS CABINET
N V LLI
m O 11
JUNCTION BOX TYPE 1, 2, 8
135W
LED
25 -TA VAULT
240V
— - - —
CONDUIT
40'
0
WIRE NOTE
SERVICE
O
CONSTRUCTION NOTE
WIRE
NOTES
26 +08
GENERAL NOTES
1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS &
SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE
CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS.
2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT
TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION.
3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE
ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH
PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425)
456 -2701 PRIOR TO INSTALLATION OF METER BASE.
4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR
SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION.
5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID
RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER
CDR STD PLAN #127.
6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL
LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED
BY THE ENGINEER IN THE FIELD.
7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE
THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL).
IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL
INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED.
8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN
ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE
CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE
ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE
CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY
REPRESENTATIVE.
9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE
PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW
PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT.
SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO
EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL
VOIDS PER SPECIAL PROVISIONS.
LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S2" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238)
LUMINAIRE
#
STATION
CONDUCTORS
OFFSET
LUMINAIRE TYPE
1
LUMINAIRE
ARM
MOUNTING
HEIGHT
POLE
TYPE
CIRCUIT
#
DECAL
#
COMMENTS
21
RAINIER AVE S,
STA
24 +77
53.5'
LT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
B
7738NL
SERVICE
#S2
22
RAINIER AVE S,
STA
24 +84
53.5'
RT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
C
7735NL
SERVICE
#S2
23
RAINIER AVE S,
STA
26 +08
53.3'
RT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
B
7737NL
SERVICE
#S2
24
RAINIER AVE S,
STA
26 +33
54.3'
LT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
C
774ONL
SERVICE
#S2
25
RAINIER AVE S,
STA
27 +66
52.0'
RT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
1 C
7739NL
SERVICE
#S2
26
RAINIER AVE S,
STA
27 +85
54.3'
LT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
B
7742NL
SERVICE
#S2
27
RAINIER AVE S,
STA
28 +66
50.0'
RT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
B
7741NL
SERVICE
#S2
P29
SHARED
POLE
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
40'
D
7738NL
SERVICE
#S2
P30
SHARED
POLE
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
40'
D
7735NL
SERVICE
#S2
P31
RAINIER AVE S,
STA
25 +53
53.5'
RT
"DECORATIVE"
SOW
LED
(S- III -FC)
240V
4'
14'
18'
D
7743L
SERVICE
#S2
P32
RAINIER AVE S,
STA
25 +66
53.5'
LT
"DECORATIVE"
SOW
LED
(S- III -FC)
240V
4'
14'
18'
D
7744L
SERVICE
#S2
P33
SHARED
POLE
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
1 14'
40'
1 D
7737NL
SERVICE
#S2
P34
SHARED
POLE
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
40'
D
774ONL
SERVICE
#S2
P35
RAINIER AVE S,
STA
26 +86
53.0'
RT
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
18'
D
7745L
SERVICE
#S2
P36
RAINIER AVE S,
STA
27 +12
54.5'
LT
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
18'
D
7746L
SERVICE
#S2
P37
SHARED
POLE
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
40'
D
7739NL
SERVICE
#S2
P38
SHARED
POLE
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
40'
D
7742NL
SERVICE
#S2
P39
RAINIER AVE S,
STA
28 +27
51.5'
RT
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
18'
D
7747L
SERVICE
#S2
P40
RAINIER AVE S,
STA
28 +56
53.5'
LT
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
18'
D
7748L
SERVICE
#S2
P41
SHARED
POLE
I
I "DECORATIVE"
60W
LED
S- III -FC
240V
4'
14'
1 40'
1 D
7741NL
SERVICE
#S2
O
0 5 10 20 40 60
SCALE IN FEET
T- 3430112
CONSTRUCTION NOTES
®RACEWAY/
CONDUIT
SIZE
CONDUCTORS
COMMENTS
1
2"
2 #8
SEE NOTES BELOW
2
2"
4 #8
SEE NOTES BELOW
3
2"
6 #8
SEE NOTES BELOW
4
4"
SPARE
5
4"
1 -96 SMFO
SEE NOTES BELOW
6
2"
SEE NOTES BELOW
7
EX.
SEE NOTES BELOW
8
4"
EX. 1 -48 SMFO
RE -ROUTE
NOTES:
1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 -#8
GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE W9RE
SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL -LINE
TAPE AND LABELED "CITY OF RENTON".
2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40,
EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT
AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE
FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS.
<D CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE,
POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL
INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL
PROVISIONS.
O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND
DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS.
SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS.
® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION.
O
® SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT.
10 FOR EXISTING JUNCTION BOX REMOVAL /MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS.
13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING.
BID
14 INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF DOCUMENTS
TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION.
T > I ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12 -16 -11 11 -14 -11 SURVEYED: KPG
P• F1 fit ]KIP RAINIER AVENUE S (SR 167) DRAWING NO. 232
°F w ^s ,� y DRAWN BY: JM CITY OF RENTON
Doti S GRADY WAY TO S 2ND ST PROJECT NO. TED403430
DESIGN BY: JF Public Works Deportment � z v F E H R &PEERS 753 91h Ave N 2502 Jefferson Ave P
CHECKBY: JF TRANSPORTATION CONSULTANTS SeatBe, WA 98109 Tacoma, WA 98402 ILLUMINATION AND INTERCONNECT PLAN FED AID NO. CM0167(048)
„„„o,,,r., .�,m,,.,.0 APPR OR CONSTRUCTION DATE: NOV 2011
9" gec 6r[aE° '�'" PROJ MGR: TN dear =�.,wu :'�.°,""°',�: '"° (206)286.1640 (253)627 -0720 A'/
FSS'ONAU EN�\a iWsiWA �o� ,„, `^ em�...W www.kpg.00m BY: DATE: ,�// STA 24 +50 TO STA 29 +00 SHEET NO. 232 OF 304
NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DILL01.dwg , 77 /L
z
�y
a
O
> 1
{ 'p
o w
N O
z