Loading...
HomeMy WebLinkAboutT-3430172LEGEND EXISTING NEW DESCRIPTION OFFSET LUMINAIRE TYPE SIGNAL POLE WITH MAST ARM Lx O ® TYPE I OR PS POLE CIRCUIT # DECAL # COMMENTS �o RAINIER AVE S, EXISTING LUMINAIRE 24 +77 53.5' DECORATIVE PEDESTRIAN LUMINAIRE "DECORATIVE" 9--0 DECORATIVE ROADWAY LUMINAIRE (M- II -FC) --6 6' DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE 40' m SIGNAL CONTROLLER CABINET SERVICE ® ELECTRICAL SERVICE CABINET RAINIER AVE S, FIT1 ITS CABINET N V LLI m O 11 JUNCTION BOX TYPE 1, 2, 8 135W LED 25 -TA VAULT 240V — - - — CONDUIT 40' 0 WIRE NOTE SERVICE O CONSTRUCTION NOTE WIRE NOTES 26 +08 GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456 -2701 PRIOR TO INSTALLATION OF METER BASE. 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER CDR STD PLAN #127. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY REPRESENTATIVE. 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S2" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) LUMINAIRE # STATION CONDUCTORS OFFSET LUMINAIRE TYPE 1 LUMINAIRE ARM MOUNTING HEIGHT POLE TYPE CIRCUIT # DECAL # COMMENTS 21 RAINIER AVE S, STA 24 +77 53.5' LT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' B 7738NL SERVICE #S2 22 RAINIER AVE S, STA 24 +84 53.5' RT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' C 7735NL SERVICE #S2 23 RAINIER AVE S, STA 26 +08 53.3' RT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' B 7737NL SERVICE #S2 24 RAINIER AVE S, STA 26 +33 54.3' LT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' C 774ONL SERVICE #S2 25 RAINIER AVE S, STA 27 +66 52.0' RT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' 1 C 7739NL SERVICE #S2 26 RAINIER AVE S, STA 27 +85 54.3' LT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' B 7742NL SERVICE #S2 27 RAINIER AVE S, STA 28 +66 50.0' RT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' B 7741NL SERVICE #S2 P29 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7738NL SERVICE #S2 P30 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7735NL SERVICE #S2 P31 RAINIER AVE S, STA 25 +53 53.5' RT "DECORATIVE" SOW LED (S- III -FC) 240V 4' 14' 18' D 7743L SERVICE #S2 P32 RAINIER AVE S, STA 25 +66 53.5' LT "DECORATIVE" SOW LED (S- III -FC) 240V 4' 14' 18' D 7744L SERVICE #S2 P33 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 1 14' 40' 1 D 7737NL SERVICE #S2 P34 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 774ONL SERVICE #S2 P35 RAINIER AVE S, STA 26 +86 53.0' RT "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 18' D 7745L SERVICE #S2 P36 RAINIER AVE S, STA 27 +12 54.5' LT "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 18' D 7746L SERVICE #S2 P37 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7739NL SERVICE #S2 P38 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7742NL SERVICE #S2 P39 RAINIER AVE S, STA 28 +27 51.5' RT "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 18' D 7747L SERVICE #S2 P40 RAINIER AVE S, STA 28 +56 53.5' LT "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 18' D 7748L SERVICE #S2 P41 SHARED POLE I I "DECORATIVE" 60W LED S- III -FC 240V 4' 14' 1 40' 1 D 7741NL SERVICE #S2 O 0 5 10 20 40 60 SCALE IN FEET T- 3430112 CONSTRUCTION NOTES ®RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS 1 2" 2 #8 SEE NOTES BELOW 2 2" 4 #8 SEE NOTES BELOW 3 2" 6 #8 SEE NOTES BELOW 4 4" SPARE 5 4" 1 -96 SMFO SEE NOTES BELOW 6 2" SEE NOTES BELOW 7 EX. SEE NOTES BELOW 8 4" EX. 1 -48 SMFO RE -ROUTE NOTES: 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 -#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE W9RE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL -LINE TAPE AND LABELED "CITY OF RENTON". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. <D CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. ® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. O ® SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT. 10 FOR EXISTING JUNCTION BOX REMOVAL /MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. BID 14 INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF DOCUMENTS TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION. T > I ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12 -16 -11 11 -14 -11 SURVEYED: KPG P• F1 fit ]KIP RAINIER AVENUE S (SR 167) DRAWING NO. 232 °F w ^s ,� y DRAWN BY: JM CITY OF RENTON Doti S GRADY WAY TO S 2ND ST PROJECT NO. TED403430 DESIGN BY: JF Public Works Deportment � z v F E H R &PEERS 753 91h Ave N 2502 Jefferson Ave P CHECKBY: JF TRANSPORTATION CONSULTANTS SeatBe, WA 98109 Tacoma, WA 98402 ILLUMINATION AND INTERCONNECT PLAN FED AID NO. CM0167(048) „„„o,,,r., .�,m,,.,.0 APPR OR CONSTRUCTION DATE: NOV 2011 9" gec 6r[aE° '�'" PROJ MGR: TN dear =�.,wu :'�.°,""°',�: '"° (206)286.1640 (253)627 -0720 A'/ FSS'ONAU EN�\a iWsiWA �o� ,„, `^ em�...W www.kpg.00m BY: DATE: ,�// STA 24 +50 TO STA 29 +00 SHEET NO. 232 OF 304 NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DILL01.dwg , 77 /L z �y a O > 1 { 'p o w N O z