Loading...
HomeMy WebLinkAboutT-3430175c_ G LOn 0 0 U 0 J 1 s a U N 0 c i 0 0 I 0 .,I i U N U d °c z GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE R/W ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH — _ _ PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456 -2701 PRIOR TO INSTALLATION OF METER BASE. — — 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR _ SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. — — 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER d COR STD PLAN #127. cli 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL 0 6 1 LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED L1 1 ui BY THE ENGINEER IN THE FIELD. _ 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE o THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL BE REMOVED, SEE SITE PREPARATION + INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. PLANS. GRIND DOWN EXISTING FOUNDATION I o 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN TO 2' BELOW PROPOSED GRADE AND CAP F- ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE AND ABANDON EXISTING UNUSED CONDUIT. Lr' CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE SPLICE EXISTING WIRING IF NECESSARY TO z ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE MAINTAIN CONNECTIONS TO EXISTING x CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY PRIVATE LUMINAIRES TO REMAIN, BACKFILL 2 093H r REPRESENTATIVE. AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. < I, CONSTRUCTION NOTES Oj CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. O CONSTRUCT FOUNDATION PER DETAILS ON SHEET 263 AND FURNISH AND INSTALL ELECTRICAL SERVICE CABINET PER COR STD DWGS J010 AND J011 WITH BACK -TO -BACK BATTERY BACKUP SYSTEM PER SPECIAL PROVISIONS. FOR LOCATION AND PANEL SCHEDULE, SEE ILLUMINATION CIRCUIT DIAGRAM AND DETAILS SHEET 238. COORDINATE CONNECTION DETAILS TO THE POWER SOURCE WITH THE POWER COMPANY REPRESENTATIVE PRIOR TO INSTALLATION OF FOUNDATION. SEE SPECIAL PROVISIONS. O LUMINAIRE TO BE PART OF A SIGNAL SYSTEM. APPLY DECAL NUMBERING TO POLE, FOR ADDITIONAL INSTALLATION DETAILS SEE SIGNAL PLANS. 0 7O EXISTING SIGNAL POLE MOUNTED LUMINAIRE. FOR REMOVAL NOTES SEE SIGNAL PLANS. 10 FOR EXISTING JUNCTION BOX REMOVAL /MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. 14 INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION. 17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS ". LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S4" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) — —_ — — 59 s � ccc� A RAINIER AVE S cc cc CCG 6 64 i -- -- — rc 45 - 43 I \ LI 2 L/ 3 7 \\ \ 5 10 13 C, 0 1 \ 41 MIC 1 10 cc 13 ` ( 13 2 1 10 13 cc 10 10 \ O ;' Q 44 _ 46 I 0 5 10 20 40 60 SCALE IN FEET LUMINAIRE # I STATION FEHR OFFSET LUMINAIRE TYPE LUMINAIRE ARM MOUNTING HEIGHT POLE TYPE CIRCUIT # DECAL # BELOW COMMENTS D1 D2 * * * SEE NOTES SEE NOTES SPARE BELOW BELOW 3 4 5 rDECORATIVEO 135W "DECORATIVE" "DECORATIVE" "DECORATIVE" "DECORATIVE" "DECORATIVE" LED (M III -FC) 240V W /PHOTOCELL_ 135W LED (M- III -FC) 240V 135W LED (M- III -FC) 240V 135W LED (M- III -FC) 240V _ 135W LED (M- II -FC) 240V 135W LED (M- II -FC) 240V * * * * * 35' 35' * * * * 40' 40' A A A A C B 7773N * SEE SIGNAL * SEE SIGNAL * SEE SIGNAL * SEE SIGNAL SERVICE SERVICE #S4 #S4 PLANS FOR INFORMATION NOT SHOWN PLANS FOR INFORMATION NOT SHOWN PLANS FOR INFORMATION NOT SHOWN PLANS FOR INFORMATION NOT SHOWN * i * * 147.5' LT 47.5' RT * * *_ _ 6' 6' 7774N 7776N 7775N 7778NL 7777NL D3 D4 43 44 RAINIER AVE S, STA 38+97 RAINIER AVE S, STA 38 +97 45 46 RAINIER AVE S, RAINIER AVE S, STA STA 40+16 40+16 149.0' 49.0' LT -- RT "DECORATIVE" "DECORATIVE" 135W LED (M- II -FC) 240V — 135W LED (M- II -FC) 240V 6' 6' 35' 35' 40' 40' B C 7780NL 7779NL SERVICE SERVICE #S4 #S4_ - -- P58 P59 P60 RAINIER AVE S, RAINIER AVE S, SHARED STA STA POLE 38 +47 38 +47 147.5' 47.5'_ LT RT "DECORATIVE" "DECORATIVE" 60W LED (S- III -FC) 240V 60W LED (S- III -FC) 240V 4' 4' 14' 14 18' _18 40' 40' 18' 18' D D D D D D 7782L 7781L SERVICE SERVICE #S4 #S4 -- 148.0' LT ',48.0' RTJ "DECORATIVE" SOW LED (S- III -FC) 240V "DECORATIVE" 6OW LED (S- III -FC) 240V "DECORATIVE" 60W LED (S- III -FC) 240V "DECORATIVE" 60W LED (S- III -FC) 240V - 4' 4' 4' 4' 14 14' 14' 14' 7778NL SERVICE #S4 7777NL SERVICE #S4 7784L SERVICE #S4 — 7783L I SERVICE #S4 P61 - -- _ SHARE_D POLE AVE S, STA 39+44 - I RAINIER AVE S, STA 39 +44 _ P RAINIER -- P63 P64 P65 SHARED ', SHARED POLE POLE - " 60W LED S- III -FC 240V ( , 4 _ 14 14' 40' _ 40' D D 7780NL' SERVICE #S4 "DECORATIVE' _ DECORATIVE" 60W LED (S- III -FC) 240V 4' 7779NL SERVICE #S4 -- AUULNUUMNZ.HtMUVtUYHIVAIt FULthtMUVALNUIt5 JJA JF 12 -16-11 Ii -14 -11 SURVEYED: KPG F or WAI, ,9A DRAWN BY: JM_._. r y DESIGN BY: JF CHECK BY: JF Q EC6rE " PROJ MGR: TN NUMBER REVISION DESCRIPTION BY APP. DATE fSS10 AL C 0655DILL01.dwg - -6 -- — WIRE NOTES p1 SEE SIGNAL PLAN - --\ EXTR FOR DETAILS Q3 SERVICE "S4 "\ ®RACEWAY/ !I CONDUIT '', SIZE FEHR & PEERS TRANSPORTATION CONSULTANTS 10014th Aver &1:e 4M K Sn.^.mfl SWUe WA My 2p515)6 -4220 -u I— c.,. IT - -6 -- — WIRE NOTES p1 SEE SIGNAL PLAN - --\ EXTR FOR DETAILS Q3 SERVICE "S4 "\ ®RACEWAY/ !I CONDUIT '', SIZE CONDUCTORS COMMENTS PROJECT NO. DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE 1 2" 2#8 SEE NOTES BELOW 2 1 2" 2" 1 4" - 4 #8 6 #8 -- - _ - SEE NOTES SEE NOTES SPARE BELOW BELOW 3 4 5 4" 1 -96 SMFO SEE NOTES SEE NOTES BELOW BELOW 62— 7 EX. 4" EX. 1 -48 SMFO SEE NOTES RE -ROUTE BELOW 8 NOTES: 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 -#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL-LINE TAPE AND LABELED "CITY OF RENTON ". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. ?� � -� 153901 Ave N 2502 Jefferson Ave Seattle, WA 98109 Tacoma, WA 98402 (20612861840 (25 3) 627-0720 vAVw.l�g.com E� CITY OF RENTON .0 Pubic Works Depertmert APPR FOR CONSTRUCTION BV: DATE:.' v "0 ccr. r LEGEND M 10 O 13 N I— w w x CD 0 CV N w z J x 10 7 < 5 17 � J i �p EXISTING NEW DESCRIPTION _= Cl-- SIGNAL POLE WITH MAST ARM DENOTES oL G • TYPE I OR PS POLE POIE DECAL# xxxx EXISTING LUMINAIRE PA T- 3430115 RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST ILLUMINATION AND INTERCONNECT PLAN STA 38 +00 TO STA 42 +00 BID DOCUMENTS DECORATIVE PEDESTRIAN LUMINAIRE C�-- DECORATIVE ROADWAY LUMINAIRE PROJECT NO. DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE Cfl SIGNAL CONTROLLER CABINET G ® ELECTRICAL SERVICE CABINET III s 1 ITS CABINET 7 z 1 m O DI JUNCTION BOX TYPE 1, 2, 8 2 A 25 -TA VAULT - -- -- CONDUIT WIRE NOTE O CONSTRUCTION NOTE T- 3430115 RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST ILLUMINATION AND INTERCONNECT PLAN STA 38 +00 TO STA 42 +00 BID DOCUMENTS z �y > m Oa �v I � N "> d � � W D 0 0 N O rA 235- DRAWING NO. _ _ PROJECT NO. TED Q3 30 FED AID NO. CM0167 048) DATE: NOV 2011 SHEET NO. 235 OF 304 z �y > m Oa �v I � N "> d � � W D 0 0 N O rA