Loading...
HomeMy WebLinkAboutT-3430176a 0 N 0 N s 0 co 0 T J IN 0 i 0 rn 0 U N C d i U 0 2 rn 0 c LEGEND EXISTING DENOTES EX ME Derx1 xxxx NEW DESCRIPTION @mm — SIGNAL POLE WITH MAST ARM • TYPE I OR PS POLE GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456 -2701 PRIOR TO INSTALLATION OF METER BASE. 4. THE LOCATON OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER CDR STD PLAN #127. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY REPRESENTATIVE. 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE `1 PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. Ln M N H w w N O 0 N L0 w z J LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S4 & S5" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) LUMINAIRE, # EXISTING LUMINAIRE `1-0 DECORATIVE PEDESTRIAN LUMINAIRE �-- DECORATIVE ROADWAY LUMINAIRE SEE DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRI m SIGNAL CONTROLLER CABINET ® ELECTRICAL SERVICE CABINET EM ITS CABINET m LI D1 JUNCTION BOX TYPE 1, 2, 8 SEE NOTES BELOW 3 m 25 —TA VAULT ---- CONDUIT A WIRE NOTE O CONSTRUCTION NOTE GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456 -2701 PRIOR TO INSTALLATION OF METER BASE. 4. THE LOCATON OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER CDR STD PLAN #127. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY REPRESENTATIVE. 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE `1 PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. Ln M N H w w N O 0 N L0 w z J LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S4 & S5" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) LUMINAIRE, # FOR STATION BOX REMOVAL /MODIFICATION OFFSET LUMINAIRE TYPE SEE LUMINAIRE MOUNTING POLE CIRCUIT DECAL COMMENTS 2 I, 2" 4 #8 SEE NOTES BELOW 3 2" 6 #8 SEE NOTES BELOW 4 4" SPARE - - 5 ARM HEIGHT TYPE # # _ SEE NOTES BELOW 47 RAINIER AVE S, STA 42 +28 52.0' LT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' C 7786NL SERVICE #S4 48 RAINIER AVE S, STA 42 +28 52.0' RT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' B 7785NL SERVICE #S4 49 RAINIER AVE S, STA 43 +52 58.5' LT "DECORATIVE" 135W LED (M- II -FC) 240V 12' 35' 40' ! B 7788N SERVICE #S4 50 RAINIER AVE S, STA 43 +48 56.5' RT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' C 7787NL SERVICE #S4 P66 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' j D 7786NL SERVICE #S4 P67 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7785NL SERVICE #S4 P68 RAINIER AVE S, STA 43 +08 53.5' LT "DECORATIVE" 60W LED (S- III -FC) 240V 4' 1C- 9 1 D 7790L SERVICE #S4 51 RAINIER AVE S, STA 44 +51 56.5' RT "DECORATIVE" 135W LED M -II -FC 240V 1 12' 1 35' 1 40' C 7789N I SERVICE #S5 CONSTRUCTION NOTES Oj CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, CDR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. 0 10 FOR EXISTING JUNCTION BOX REMOVAL /MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. C*T N H w w x CD CD Ln a w z J x WIRE NOTES ®RACEWAY /I CONDUIT 1 CONDUCTORS COMMENTS SIZE 1 2" 2 #8 SEE NOTES BELOW 2 I, 2" 4 #8 SEE NOTES BELOW 3 2" 6 #8 SEE NOTES BELOW 4 4" SPARE - - 5 4" _ 9 - - -- 1 -96 SMFO SEE NOTES BELOW S 6 2" _ SEE NOTES BELOW 7 EX. SEE NOTES BELOW 8 I 4" EX, 1 -48 SMFO RE -ROUTE NOTES: 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 -#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL-LINE TAPE AND LABELED "CITY OF RENTON ". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. 0 5 10 20 40 60 SCALE IN FEET T- 3430116 BID DOCUMENTS ADDENDUM 02, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12 -16 -11 _ t t -t a -t SURVEYED. KPG.. _- P' p KPH RAINIER AVENUE S (SR 167) DRAWING NO. 236 o� WAS,, ti DRAWN BY: JIM CITY OF RENTON - O �P'. DESIGN BY: JF S GRADY WAY TO S 2ND ST PROJECT NO, gp40�g3o FEHR & PEERS 753b Ave N 2502JeffmAve Pubic worts Deportment FED AID NO. CM0167��481 CHECK BY: JF _ TRANSPORTATION CONSULTANTS Seattle, WA 99109 Tacoma, WA 98402 ILLUMINATION AND INTERCONNECT PLAN ",", ,.0 APPR V D FOR CONSTRUCTION 9' RFCSrra °O �Ea� PROJ MGR: TN a;.� o� -..e. (06)29fr1640 (253) 627 -0720 DATE: _NOV 2011 Sg G _ -- s um.e. wn www,kpg.COfll BY: DATF� SHEET NO. 236 OF 304_ NUMBER REVISION DESCRIPTION BY APP. DATE P TONALEN n FILE:0655DILL01.dwg '2�'' V644M //t STA 42 +00 TO STA 45 +00 a a z `m a M j•�•j O J > !� a � o O N