HomeMy WebLinkAboutT-34301770 m 0 C, s_ 0 , O j LEGEND EXISTING NEW DESCRIPTION Cam- SIGNAL POLE WITH MAST ARM OW �i • TYPE I OR PS POLE xxxx EXISTING LUMINAIRE DECORATIVE PEDESTRIAN LUMINAIRE DECORATIVE ROADWAY LUMINAIRE D ECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE m SIGNAL CONTROLLER CABINET e w w O O 1d- H v7 w Z J a Qt ® ELECTRICAL SERVICE CABINET j © ITS CABINET m 1017 JUNCTION BOX TYPE 1, 2, 8 r&7Al 25 -TA VAULT CONDUIT WIRE NOTE / 13 TR I / O CONSTRUCTION NOTE � 10 cc �,�wvLSa MIC7/ / : / 46 MIC7q 0 : XXXX- X 8 1 - 13 - - -- 13 11 3123H / C4 Z CO 55 � ccc 2 13 // 2 / O 1 6 2 / 10 10 (711 I . r E1 13 / of E2 P I SEE SIGNAL PLAN 5 \ 13 t I / FOR DETAILS OSERVICE " " —_` / D GENERAL NOTES ccc LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S5" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) LUMINAIRE STATION OFFSET LUMINAIRE TYPE 2 2" LUMINAIRE MOUNTTNG POLE CIRCUIT DECAL _ 6#8 COMMENTS # 4 5 6 4" 4" 2" SPARE — 1 -96 SMFO SEE NOTES SEE NOTES BELOW BELOW 7 EX. ARM HEIGHT TYPE # # FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. E1 * * "DECORATIVE" 135W LED (M- 111 -FC) 240V W /PHOTOCELL * * * A 7791N '* SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN E2 - * REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND * "DECORATIVE" 135W LED (M- III -FC) 240V * * * A 7793N '* SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN E3 * _ * DECORATIVE' 135W LED (M III -FC) - 240V * * * A 7792N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN 52 I RAINIER AVE S STA 45+13 53.5' LT' "DECORATIVE" 135W LED (M II FC) 240V 6 35 40' C 7794NL SERVICE #S5 53 RAINIER AVE S, STA 45 +16 561 RT DECORATIVE" 135W LED (M- II -FC) 240V 12' 35 40' _ B 7795N SERVICE #S5 54 S SUNSET BLVD, 43.1' LT "DECORATIVE" 135W LEO M -II -FC 240V 6' _ 35' 40' C 7796N SERVICE # SS 55 S SUNSET BLVD, STA 551 +26 50 2' RT _ bECORATIVE" 135W LED (M II -FC) 240V _ 6' _ 35' 40 B 7797N SERVICE #S5 56 RAINIER AVE S, STA 47 +23 65.4' LT "DECORATIVE" 135W LED (M- III -FC) 240V 6' 35' 40' C 7798N SERVICE #S5 57 RAINIER AVE S, STA 47 +89 1152.2' LT "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' B 780ONL 'SERVICE #S5 P70 SHARED POLE "DECORATIVE" 60W LED (S- III -FC) 240V 4' 14' 40' D 7794NL SERVICE #S5 i.. cc 0 5 10 20 40 60 SCALE IN FEET WIRE NOTES ®:RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS 111 2 2 2" 248 4#8 SEE NOTES SEE NOTES BELOW BELOW 3 2" _ 6#8 _ SEE NOTES BELOW 4 5 6 4" 4" 2" SPARE — 1 -96 SMFO SEE NOTES SEE NOTES BELOW BELOW 7 EX. - - - -------------- EX 1-48 SMFO SEE NOTES — - RE-ROUTE BELOW - - -- 8 4" FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. CONSTRUCTION NOTES CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, CDR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL �Zr r PROVISIONS. 4 4 51 ccc NOTES: \ 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 -#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE y SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL-LINE 10 078H TAPE AND LABELED "CITY OF RENTON ". 4 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, 13 EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT ccc AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE 48 FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. CONSTRUCTION NOTES CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, CDR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL �Zr r PROVISIONS. 4 4 O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND ch DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. • 4 crc O CONSTRUCT FOUNDATION PER DETAILS ON SHEET 263 AND FURNISH AND INSTALL ELECTRICAL SERVICE CABINET PER CDR STD DINGS J010 AND J011 WITH BACK -TO -BACK BATTERY BACKUP SYSTEM PER SPECIAL PROVISIONS. FOR LOCATION AND PANEL / SCHEDULE, SEE ILLUMINATION CIRCUIT DIAGRAM AND DETAILS SHEET 238. COORDINATE CONNECTION DETAILS TO THE POWER / SOURCE WITH THE POWER COMPANY REPRESENTATIVE PRIOR TO INSTALLATION OF FOUNDATION. SEE SPECIAL PROVISIONS. FkTR cc ® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. / O LUMINAIRE TO BE PART OF A SIGNAL SYSTEM. APPLY DECAL NUMBERING TO POLE, FOR ADDITIONAL INSTALLATION DETAILS SEE 409H / SIGNAL PLANS. 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & 0 4 p� 4 SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE 1 10 CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. / RAW I \ 1 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE GENERAL NOTES (CONTINUED) \ RESPONSIBIUTY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT 7 NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE O7 EXISTING SIGNAL POLE MOUNTED LUMINAIRE. FOR REMOVAL NOTES SEE SIGNAL PLANS. . ® TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 360 DEGREES TOTAL 4 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE THAN THE EQUIVALENT OF FOUR QUARTER BENDS IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL ) . ®SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT. ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH c* INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 10 FOR EXISTING JUNCTION BOX REMOVAL MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. cc C 456 -2701 PRIOR TO INSTALLATION OF METER BASE. PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) g, ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN / ' h 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE 1O3 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. T=3430177 ' ccc M SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE 17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS ". / 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY ©0 SEE URBAN DESIGN PLAN SHEETS FOR CONTINUATION OF ARCHITECTURAL LIGHTING. CDR STD PLAN #127. REPRESENTATIVE. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BID LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN BY THE ENGINEER IN THE FIELD. CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. O DOCUMENTS ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12 -16 -11 n -.a -n SURVEYED: _KPG____ O��P _Fy � �p� / CITY OF RENTON RAINIER AVENUES (SR 167) DRAWING NO. 237 pF NnSHr�s.9 DRAWN BY: JM_- _ ff _ `q_ %y DESIGN BY' JF - P,b is Worts Deportment S GRADY WAY TO S 2ND ST PROJECT NO. LEa4403430 FEHR &PEERS 7539hAveN 2502JeflesonAve CHECK BY: TRANSPORTATION CONSULTANTS Sealde,WA98109 Tacoma, WA 98W2 ILLUMINATION AND INTERCONNECT PLAN FED AID NO. cMOo4s> nc 1 2 o a .� c. AP PR FOR CONSTRUCTION DATE: NOV 2011 9: PFC, r[REO ��"�" PROJ MGR. TN sue, i4t- izo ""� w :'s.. .w.o- (20612661640 (2531627 -0720 - es`SrONAL ENO\ - mil; siWA �� ^"^° '� "v wv BY DATE STA 45 +00 TO STA 49 +00 SHEET NO. 237_ OF 304 _ NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DILL01.dwg °'^^•° volr a z n a m N Oa I :5C) �=j J d ' K w o w 0 i y _