Loading...
HomeMy WebLinkAboutT-3430194rL N 0 N v C'J Q CD T Q V J F N I 0 i 0 0 rn 0 0 a U O d rn 0 0 WIRE SCHEDULE tie Qk/ y o� 05 `•Z1 ��' �L4 Vp tiheNa, 0�1x °° 5� e� N � c 1 2" 2_ — 2" - 4 2 2 . -3 3 1 4" 4- 6 -6 6- 4 4 - - NOTES: 1. UNLESS OTHERWISE SPECIFIED, ALL PROPOSED SIGNAL AND FIBER OPTIC CONDUIT SHALL BE RIGID PVC SCH 80. 2. ALL TWISTED PAIRS ENTERING SIDEWALK SHALL BE INSTALLED IN 2" CONDUIT. 3. ALL PVC CONDUITS CONTAINING CONDUCTORS SHALL INCLUDE GROUND WIRE. GROUND WIRE SIZE SHALL MATCH THE LARGEST CONDUCTOR (MIN #8 AWG OR AS NOTED OTHERWISE IN THE 'WIRE NOTES). SPARE /EMPTY CONDUIT SHALL BE LABELED "CITY OF RENTON* AND SHALL CONTAIN BULL—UNE TAPE. CONSTRUCTION NOTES O1 CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE WITH MAST AND LUMINAIRE ARMS. INSTALL TWO VEHICLE SIGNAL HEADS, ONE TYPE 722 EMERGENCY PRE- EMPT10N DETECTOR (PER CDR STD DWG J032) ONE VEHICLE DETECTION CAMERA, ONE REGULATORY SIGN, AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE ROADWAY DECORATIVE LUMINAIRE WITH PHOTOCELL (SEE LUMINAIRE SCHEDULE, ILLUMINATION SHEET 235) ON THE SIGNAL MAST ARM. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO PUSH BUTTON ASSEMBLIES (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS) AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEETS 261, 262 AND SPECIAL PROVISIONS. 02 CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE WITH MAST AND LUMINAIRE ARMS. INSTALL FOUR VEHICLE SIGNAL HEADS, ONE VEHICLE DETECTION CAMERA, TWO REGULATORY AND ONE STREET NAME SIGNS ON THE MAST ARM. INSTALL ONE ROADWAY DECORATIVE LUMINAIRE (SEE LUMINAIRE SCHEDULE, ILLUMINATION SHEET 235) ON THE SIGNAL MAST ARM. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO PUSH BUTTON ASSEMBLIES (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS), ONE REGULATORY SIGN, AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEETS 261, 262 AND SPECIAL PROVISIONS. O3 CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE WITH MAST AND LUMINAIRE ARMS. INSTALL TWO VEHICLE SIGNAL HEADS, ONE VEHICLE DETECTION CAMERA, ONE REGULATORY SIGN, AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE ROADWAY DECORATIVE LUMINAIRE (SEE LUMINAIRE SCHEDULE, ILLUMINATION SHEET 235) ON THE SIGNAL MAST ARM. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO PUSH BUTTON ASSEMBLIES (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS) AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEET 261 AND SPECIAL PROVISIONS. ® CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE WITH MAST AND LUMINAIRE ARMS. INSTALL FOUR VEHICLE SIGNAL HEADS, ONE TYPE 722 EMERGENCY PRE- EMPHON DETECTOR (PER COR STD DWG J032), ONE VEHICLE DETECTION CAMERA, TWO REGULATORY AND ONE STREET NAME SIGNS ON THE MAST ARM. INSTALL ONE ROADWAY DECORATIVE LUMINAIRE (SEE LUMINAIRE SCHEDULE, ILLUMINATION SHEET 235) ON THE SIGNAL MAST ARM. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO PUSH BUTTON ASSEMBLIES (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS), ONE REGULATORY SIGN, AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEETS 261, 262 AND SPECIAL PROVISIONS. O CONSTRUCT TRAFFIC CONTROLLER CABINET FOUNDATION PER COR STD DWG J028 AND FURNISH AND INSTALL TYPE "P" CONTROLLER CABINET, CONTROLLER, ALL ASSOCIATED EQUIPMENT AND CONNECT FIELD WIRING. FOUNDATION TO BE LOCATED AT RAINIER AVENUE S, AT APPROXIMATE STA 40 +90, 62' RT. SEE SPECIAL PROVISIONS. © CONSTRUCT FOUNDATION AND FURNISH AND INSTALL ELECTRICAL SERVICE /BPS CABINET PER ILLUMINATION SHEETS. 70 REMOVE EXISTING FOUNDATION, LUMINAIRE POLE AND ASSOCIATED JUNCTION BOX PER ILLUMINATION PLANS. ® VIRTUAL VEHICLE DETECTION ZONE. SHOWN FOR REFERENCE ONLY. FINAL ZONE LOCATIONS SHALL BE DETERMINED BY THE ENGINEER IN THE FIELD. Q9 FOLLOWING ACTIVATION OF NEW SIGNAL SYSTEM, INCLUDING VEHICLE DETECTION VIDEO SYSTEM, REMOVE EXISTING SIGNAL POLE AND ALL ASSOCIATED EQUIPMENT AND WIRING. GRIND DOWN EXISTING FOUNDATION 2 FEET BELOW PROPOSED GRADE AND BACKFILL AND COMPACT PER SPECIAL PROVISIONS. CAP AND ABANDON EXISTING CONDUIT. SALVAGE EXISTING EQUIPMENT AS DETERMINED BY THE ENGINEER IN FIELD AND PER SPECIAL PROVISIONS. 10 REMOVE EXISTING JUNCTION BOX AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. REMOVE EXISTING UNUSED WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. 11 FOLLOWING ACTIVATION OF NEW SIGNAL SYSTEM, REMOVE EXISTING SIGNAL CONTROLLER CABINET, BRACKET MOUNTED ELECTRICAL SERVICE AND ALL ASSOCIATED EQUIPMENT /CONDUIT /WIRING (SALVAGE PER SPECIAL PROVISIONS). REMOVE FOUNDATION AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. 12 ABANDON EXISTING VEHICLE DETECTION LOOPS AND REMOVE ASSOCIATED WIRING FROM STUBOUT TO CONTROLLER. 13 EXISTING JUNCTION BOX TO REMAIN. FOR WIRING /CONDUIT MODIFICATIONS SEE WIRE SCHEDULE THIS SHEET. 14 INSTALL NEW VEHICLE DETECTION LOOP AS PER CDR STD DWG J038 AND J039. SEE SPECIAL PROVISIONS. 15 SEE ILLUMINATION SHEETS FOR CONTINUATION OF CONDUIT AND WIRING. 16 INSTALL TYPE 25 -TA VAULT WITH FIBER SPLICE ENCLOSURE AND COIL 50 FEET OF EACH FIBER CABLE. SEE DETAILS ON SHEET 265. 17 INSTALL IRRIGATION CONTROLLER CABINET AND ASSOCIATED CONDUIT /WIRING PER IRRIGATION PLANS. 18 APPROXIMATE PSE POWER SOURCE LOCATION, COORDINATE FINAL CONNECTION WITH PSE REPRESENTATIVE. �T- 25- TA SERVICE "S4 "(,2.Y \ T= 3430194 17 �R ENLARGED SIGNAL DETAIL BID SCALE: 1"= 5' -0" DOCUMENTS 11 -14 -n SURVEYED: KPG 254 o "FA °9G DRAWN BY JM FEHRaTISt PEERS 753iAiJeBe CITY OF RENTON RAINIER AVENUES (SR 167) DRAwINGNO. S GRADY WAY TO S 2ND ST PROJECT NO. TED403430 DESIGN BY' JF Pub 1c `NOras Department CHECK BY. JP Sea&.WA98109 Tacoma, WA 98402 SIGNALIZATION PLAN FED AID NO. CM0167L048) v <r, n a 4Q' W 4n M.. °,°,.`�'' ° `°^r°,,. ri. (206I2W1640 (25.31627 -0720 APPROV FOR CONSTRUCTION DATE: NOV 2011 0i. fp, t[0.0 �4. PROJ MGR' TN RANIER AVE S & S 3RD PLACE FS3 /oNa�EN -- isi4220 < °v �'km' SHEET NO. 254 - OF 304 - NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DSIG01.dwg ^ ^•G BY: DATE// /Z a z n a < jrj h /�I O G n � '> ~ o O N_ O