Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T-3430198
ED CN CN WIRE SCHEDULE ACT Fp1 pc`pJ G1 G1 Q�ti ` °P p1��, l � 'KD L�� CO 677iZ� 1 2" DRAWN BY: JC 4 DESIGN BY: JC CHECK BY: RJH PROJ MGR: JF FILE: 0655DSIG02.dwg 2 2" 4 2" 2 3 2" 4 2" 4 4 3" 1 2 2 4 1 1 3" 4 2 5 3" 1 3 3 3° 1 SPARE 6 4" 4 4 4 4" 4 2 3 7 3" 5 5 5 3" 6 2 3 1 8 2" 6 4 9 3" 10 6 3 10 3" 3 11 2" 1 12 2" SPARE 13 2" 2 3" 2 4 4 14 3" 6 2 3" 6 1 1 1 15 2" 1 2° 2 3" 2 2 2 16 3° 3 1 1 2° 4 2 1 7 2" 3 2" 2 18 2" 3 19 2" 3 2" 6 20 2° 3 Y SPARE 21 IEX 2" 2 22 3 " P2' 3 1 1 1 2 2 3 23 3" 1 1 24 3" 1 2 2 1 1 2° 2 25 3" 2 1 1 1 1 1 2° 2 26 3" 1 1 27 3" 1 2 1 2 28 2" 1 29 2" 1 30 2° 4 31 4° 1 32 4° SPARE 33 2" 3 s BRIDE TSP ANTENNA AND CAT 5e CABLE TO BE INSTALLED IN THE FUTURE BY KING COUNTY METRO. NOTES: 1. UNLESS OTHERWISE SPECIFIED, ALL PROPOSED SIGNAL CONDUIT SHALL BE RIGID PVC SCH 80. 2. ALL TWISTED PAIRS ENTERING SIDEWALK SHALL BE INSTALLED IN 2" CONDUIT. 3. ALL PVC CONDUITS CONTAINING CONDUCTORS SHALL INCLUDE GROUND WIRE. GROUND WIRE SIZE SHALL MATCH THE LARGEST CONDUCTOR (MIN #8 AWG OR AS NOTED OTHERWISE IN THE WIRE NOTES). SPARE /EMPTY CONDUIT SHALL BE LABELED "CITY OF RENTON" AND SHALL CONTAIN BULL —UNE TAPE. 2 12 A n 2 4 TO POWER SOURCE ENLARGED SIGNAL DETAIL A 12 SCALE: 1" = 5-0" REVISION DESCRIPTION ��ll r - -T__- SERVICE "S5" 7 BY I APP.I DATE O CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE WITH MAST AND LUMINAIRE ARMS. INSTALL FOUR VEHICLE SIGNAL HEADS, TWO TYPE 721 EMERGENCY PRE - EMPTION DETECTORS (PER CDR STD DWG J032), ONE VEHICLE DETECTION CAMERA, ONE TSP ANTENNA (TO BE FURNISHED AND INSTALLED BY OTHERS) TWO REGULATORY AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE ROADWAY DECORATIVE LUMINAIRE WITH PHOTOCELL (SEE LUMINAIRE SCHEDULE, ILLUMINATION SHEET 237) ON THE LUMINAIRE ARM. INSTALL ONE PEDESTRIAN SIGNAL HEAD AND ONE PUSH BUTTON ASSEMBLY (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS) AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEET 261, 262 AND SPECIAL PROVISIONS. O INSTALL FOUNDATION AND TYPE PS SIGNAL POLE PER COR STD DWG J021. INSTALL ONE PEDESTRIAN SIGNAL HEAD AND: ONE PUSH BUTTON ASSEMBLY (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS) ON THE POLE. FOR POLE AND FOUNDATION LOCATION SEE POLE SPECIFICATIONS SHEET 261, 262 AND SPECIAL PROVISIONS. O CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE WITH MAST AND LUMINAIRE ARMS. INSTALL THREE VEHICLE 'SIGNAL HEADS, ONE TYPE 721 EMERGENCY PRE- EMPTION DETECTOR (PER CDR STD DWG J032), ONE VEHICLE DETECTION CAMERA, ONE REGULATORY AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE ROADWAY DECORATIVE LUMINAIRE (SEE LUMINAIRE SCHEDULE, ILLUMINATION SHEET 237) ON THE LUMINAIRE ARM. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO PUSH BUTTON ASSEMBLIES (PER DETAIL, SHEET'' 264 AND SPECIAL PROVISIONS) AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEET 261, 262 AND SPECIAL PROVISIONS 4 CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE WITH MAST AND LUMINAIRE ARMS. INSTALL FOUR VEHICLE SIGNAL HEADS, ONE VEHICLE DETECTION CAMERA, TWO REGULATORY SIGNS, AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE ROADWAY DECORATIVE LUMINAIRE (SEE LUMINAIRE SCHEDULE, ILLUMINATION SHEET 237) ON THE LUMINAIRE ARM. INSTALL ONE PEDESTRIAN SIGNAL HEAD, ONE PUSH BUTTON ASSEMBLY (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS), ONE PTZ CAMERA AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEET 261, 262 AND SPECIAL PROVISIONS. O INSTALL FOUNDATION AND TYPE PS SIGNAL POLE PER CDR STD DWG J021. INSTALL ONE PEDESTRIAN SIGNAL HEAD AND ONE PUSH BUTTON ASSEMBLY (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS) ON THE POLE. © INSTALL FOUNDATION AND LUMINAIRE PER ILLUMINATION PLANS. INSTALL TWO PEDESTRIAN SIGNAL HEADS AND TWO PUSH' BUTTON ASSEMBLIES (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS) ON THE POLE. SEE SPECIAL PROVISIONS. O CONSTRUCT TRAFFIC CONTROLLER CABINET FOUNDATION PER CDR STD DWG J028 AND FURNISH AND INSTALL TYPE "P" CONTROLLER CABINET, CONTROLLER, ALL ASSOCIATED EQUIPMENT AND CONNECT FIELD WIRING. FOUNDATION TO BE LOCATED AT RAINIER AVENUE S, AT APPROXIMATE STA 550 +78, 31' LT. SEE SPECIAL PROVISIONS. ® CONSTRUCT FOUNDATION AND FURNISH AND INSTALL ELECTRICAL SERVICE CABINET PER ILLUMINATION SHEETS. Q9 VIRTUAL VEHICLE DETECTION ZONE. SHOWN FOR REFERENCE ONLY. FINAL ZONE LOCATIONS SHALL BE DETERMINED BY THE ENGINEER IN THE FIELD. 10 FOLLOWING ACTIVATION OF NEW SIGNAL SYSTEM, INCLUDING VEHICLE DETECTION VIDEO SYSTEM, REMOVE EXISTING SIGNAL POLE AND ALL ASSOCIATED EQUIPMENT AND WIRING. GRIND DOWN EXISTING FOUNDATION 2 FEET BELOW PROPOSED GRADE AND BACKFILL AND COMPACT PER SPECIAL PROVISIONS. CAP AND ABANDON EXISTING CONDUIT. SALVAGE EXISTING EQUIPMENT AS DETERMINED BY THE ENGINEER IN FIELD AND PER SPECIAL PROVISIONS. 11 REMOVE EXISTING JUNCTION BOX AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. REMOVE EXISTING UNUSED WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. FOLLOWING ACTIVATION OF NEW SIGNAL SYSTEM, REMOVE EXISTING SIGNAL CONTROLLER CABINET, BRACKET MOUNTED ELECTRICAL SERVICE AND ALL ASSOCIATED EQUIPMENT /CONDUIT /WIRING (SALVAGE PER SPECIAL 12 PROVISIONS). REMOVE FOUNDATION AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. 13 ABANDON EXISTING VEHICLE DETECTION LOOPS AND REMOVE ASSOCIATED WIRING FROM STUBOUT TO CONTROLLER. 14 REMOVE EXISTING FOUNDATION, LUMINAIRE POLE AND ASSOCIATED JUNCTION BOX PER ILLUMINATION PLANS. 15 SEE ILLUMINATION SHEETS FOR LUMINAIRE POLE REMOVAL /MODIFICATIONS CONSTRUCTION NOTES. i6 INSTALL NEW VEHICLE DETECTION LOOP AS PER CDR STD DWG J038 AND J039. SEE SPECIAL PROVISIONS. 17 INSTALL FOUNDATION AND LUMINAIRE POLE PER ILLUMINATION PLANS. INSTALL ONE ADVANCED TYPE 721 EMERGENCY PRE- EMPTION DETECTOR ON PREFABRICATED 3/4" THREADED INSERT MOUNTED ON LUMINAIRE POLE (APPROX 20' MOUNTING HEIGHT). 18 INSTALL TYPE 25 -TA VAULT WITH FIBER SPLICE ENCLOSURE AND COIL 50 FEET OF EACH FIBER CABLE. SEE DETAILS ON'', SHEET 265. 0 19 CONSTRUCT FOUNDATION AND INSTALL 336A "RAPID RIDE" COMMUNICATION CABINET AS SHOWN IN THE RAPID RIDE CABINET DETAILS ON SHEET 263. CABINET AND ASSOCIATED EQUIPMENT TO BE PROVIDED BY OTHERS. COORDINATE CABINET DELIVERY WITH KING COUNTY METRO REPRESENTATIVE. ©0 SEE ILLUMINATION SHEETS FOR CONTINUATION OF CONDUIT AND WIRING. 21 EXISTING POLE, LUMINAIRE, AND JUNCTION BOX TO REMAIN. PROTECT CIRCUIT CONTINUITY DURING CONSTRUCTION. © APPROXIMATE PSE POWER SOURCE LOCATION, COORDINATE FINAL CONNECTION WITH PSE REPRESENTATIVE, T 3430198 Q SEE URBAN DESIGN PLAN, SHEET 280, FOR CONTINUATION OF ARCHITECTURAL LIGHTING. ® INTERCEPT EXISTING CONDUIT AND DAYLIGHT IN NEW TYPE I JUNCTION BOX. CAP AND ABANDON UNUSED CONDUIT. JUNCTION BOX AND CONDUIT CONNECTION SHALL BE VERIFIED BY THE ENGINEER IN THE FIELD. D REUSE EXISTING STUBOUT TO EXISTING JUNCTION BOX. 26 LOCATION OF EXISTING LUMINAIRE POLE AND ALL EXISTING ASSOCIATED EQUIPMENT /WIRING /CONDUIT TO REMAIN. PROTECT EXISTING CONDUIT /WIRING DURING CONSTRUCTION. CAP AND ABANDON UNUSED CONDUIT AND REMOVE UNUSED WIRING. SIGN SCHEDULE ITS 16 25 -TA oK ONL ONL ONL P, C w sy� e 39324 'n [STE ��ONAL C" 11 -14 -11 SURVEYED: KPG DRAWN BY: JC \ DESIGN BY: JC CHECK BY: RJH PROJ MGR: JF FILE: 0655DSIG02.dwg 1 0 CD Q R3 -8 (MOD) R3 -8 (MOD) D3 -1 R3 -8 (MOD) NOTE: (42" x 36 ") (42" x 36 ") (96" x 24 ") (42" x 36 ") 1. STREET NAME SIGNS ARE STANDARD ALUMINUM MAST ARM MOUNTED, REFLECTORIZED WHITE ON GREEN BACKGROUND. 2. ALL STREET NAME SIGNS SHALL COMPLY WITH MUTCD 2009 STANDARDS AND SHALL BE APPROVED BY THE ENGINEER. KpGr 753981 Avenue N 2502 Jeffewn Avenue SeafOe,WA98109 Time, WA98402 (206)2861640 (253) 627 -0720 www.kpg.mm 64 4 } CITY OF RENTON BID ba Public Works Department DOCUMENTS APPROVED \ FOR CONSTRUCTION BY: 11% , DATE: /N /L/ D3 -1 (72" x 18 ") '', D3 -1 (96"x 24 ") RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST SIGNALIZATION NOTES RAINIER AVE S & S 3RD ST E 0 CD R3 -6 (MODIFIED) R3 -7 (MODIFIED) (30" x 36 ") (30" x 42 ") DRAWING NO. 258 PROJECT NO. TED403430 FED AID NO. - CM0167(048) DATE: NOV 2011 SHEET NO. 258 OF 304 S z m `] � r] �j•j m /r a O G � n fn �a o C) w N O v� -T