Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T-3430213
s LEGEND EXISTING NEW D DESCRIPTION • P POLE WITH DECORATIVE POST -TOP GLOBE R RAINIER AVE S +e I IN- GROUND LED LUMINAIRE ® ® E ELECTRICAL SERVICE CABINET 8 J JUNCTION BOX TYPE 1 ELECTRICAL SERVICE An GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CITY STANDARDS, WSOOT /APWA STANDARD PLANS, STANDARD SPECIFICATIONS, LATEST AMENDMENTS TO THE STANDARD SPECIFICATIONS, SPECIAL PROVISIONS AND THESE PLANS. 2. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND POLES (ALL NEW FOUNDATION LOCATIONS AND ANCHOR BOLT ORIENTATIONS SHALL BE APPROVED BY THE ENGINEER PRIOR TO EXCAVATION) SHOWN ON THIS PLAN ARE FOR GRAPHIC PRESENTATION ONLY AND FINAL LOCATIONS SHALL BE DETERMINED BY THE ENGINEER IN THE FIELD. 3. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). 4. ALL NEW JUNCTION BOX LIDS PLACED IN WALKWAYS SHALL HAVE SKID RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS. 5. CONTRACTOR SHALL COORDINATE WITH ARTIST BENSON SHAW AT (206) 595 -2154 FOR THE LUMINAIRE AND POST -TOP GLOBE INSTALLATION. 6. SEE ILLUMINATION PLANS FOR CONNECTION TO THE POWER SOURCE AND CONDUIT TRENCH DETAILS. 7. AFTER INSTALLATION OF FULLY - FUNCTIONING IN- GROUND LED LIGHTING SYSTEM, CONTRACTOR SHALL COORDINATE WITH THE ENGINEER ON THE FINAL TILT ANGLE OF THE LUMINAIRE WHEN THE SYSTEM HAS BEEN ENERGIZED. WIRE NOTES ®RACEWAY/ CONDUIT CONDUCTORS COMMENTS SIZE 1 2" SPARE 2 2" 2 -#8 (ILL) NOTES: 1. ALL NEW CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 - #8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE). 2. ALL NEW CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. FACE OF WALL A 40c" l0 CE IN GROUND LED LUMINAIRES AND WALL SIGN o� N f, FINISH GRADE FACE OF WALL A LIGHT PATH o � i h~ i FLkrSH 1 OPTICAL ASSEMBLY TILTED FOR IN- GROUND LED LUMINAIRE (TYP) - GROUND LED LUMINAIRE LAYOUT DETAIL IN- GROUND LED LUMINAIRE LAYOUT AND ORIENTATION DETAIL IN MAXIMUM WALL ILLUMINANCE IN- GROUND LED LUMINAIRE, TOP OF LIGHT SET FLUSH WITH FINISH GRADE TYPICAL OPTICAL ASSEMBLY ORIENTATION e PLAN 2 0 5 10 20 30 SCALE IN FEET CONSTRUCTION NOTES O1 CONSTRUCT FOUNDATION FOR DECORATIVE ART POLE. FURNISH AND INSTALL DECORATIVE ART POLE, CONDUIT /WIRING AND ALL ASSOCIATED EQUIPMENT. INSTALLATION OF THE RISER ASSEMBLY AND POST -TOP GLOBE BY OTHERS. FOR INSTALLATION DETAILS, SEE ELECTRICAL DETAILS SHEET 274, ILLUMINATION PLANS (CONDUIT TRENCH DETAIL), COR STANDARD DRAWINGS J013 AND SPECIAL PROVISIONS. O CONSTRUCT WALL WITH ANCHOR BOLTS PER UBRAN DESIGN DETAIL SHEETS 269 -272. FURNISH AND INSTALL DECORATIVE ART POLE, CONDUIT /WIRING AND ALL ASSOCIATED EQUIPMENT ON TOP OF THE WALL. INSTALLATION OF THE RISER ASSEMBLY AND POST -TOP GLOBE BY OTHERS. FOR INSTALLATION DETAILS, SEE ELECTRICAL DETAILS SHEET 274, ILLUMINATION PLANS (CONDUIT TRENCH DETAIL), COR STANDARD DRAWINGS J013 AND SPECIAL PROVISIONS. O FURNISH AND INSTALL IN- GROUND LED LUMINAIRE, CONDUIT /WIRING AND ALL ASSOCIATED EQUIPMENT PER "IN- GROUND LED LUMINAIRE LAYOUT DETAIL ", ELECTRICAL DETAILS SHEET 274. IN- GROUND LED LUMINAIRES SHALL BE FIELD LOCATED IN THE PRESENCE OF THE ENGINEER AND THE ARTIST. SEE SPECIAL PROVISIONS. ® INSTALL NEW JUNCTION BOX TYPE 1 PER "JUNCTION BOX LAYOUT DETAIL ", URBAN DESIGN DETAILS SHEET 271. LID SHALL BE LABELED "LT". O FOR CONTINUATION OF CONDUIT /WIRING, SEE ILLUMINATION PLANS. © LOCATION OF POWER SOURCE. SEE ILLUMINATION PLANS FOR CONSTRUCTION NOTE, WIRING AND DETAILS. O TERMINATE CONDUIT FOR IN- GROUND LED LUMINAIRES IN DECORATIVE ART POLE. SPLICE IN- GROUND LED LUMINAIRE WIRING INTO DECORATIVE ART POLE CIRCUIT. T- 3430213 I 11.1411 SURVEYED: KPG >� CITY OF RENTON ( ) �P>s�w °sn. 7t�� ,� RAINIER AVENUES SR 167 DRAWING NO. 273 'f DRAWN BY: JHL ii Re 9 BID "� S GRADY WAY TO S 2ND ST PROJECT NO. TED403430 _ z DESIGN BY: JHL 7539th AvenueN 2562 Jefferson Avenue Public Works Department FED AID NO. - CM0167(048) CHECK BY: JC Sege, WA 98109 Tacoma, WA 98462 DOCUMENTS ELECTRICAL PLAN AND DETAILS A 39324 2� APP FOR CONSTRUCTION DATE: NOV 2011 PROJ MGR: JF (2061286.1640 (253)627 -0720 " "COm BY: DATE: SW GRADY WAY INTERSECTION SHEET NO. 273 OF 304 NUMBER REVISION DESCRIPTION BY APP. DATE FILE: Details.dwg : a a z n `] a r'] m /r ti O =C N�a a � o :IJ o w N O NOTES: 1. ALL NEW CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 - #8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE). 2. ALL NEW CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. FACE OF WALL A 40c" l0 CE IN GROUND LED LUMINAIRES AND WALL SIGN o� N f, FINISH GRADE FACE OF WALL A LIGHT PATH o � i h~ i FLkrSH 1 OPTICAL ASSEMBLY TILTED FOR IN- GROUND LED LUMINAIRE (TYP) - GROUND LED LUMINAIRE LAYOUT DETAIL IN- GROUND LED LUMINAIRE LAYOUT AND ORIENTATION DETAIL IN MAXIMUM WALL ILLUMINANCE IN- GROUND LED LUMINAIRE, TOP OF LIGHT SET FLUSH WITH FINISH GRADE TYPICAL OPTICAL ASSEMBLY ORIENTATION e PLAN 2 0 5 10 20 30 SCALE IN FEET CONSTRUCTION NOTES O1 CONSTRUCT FOUNDATION FOR DECORATIVE ART POLE. FURNISH AND INSTALL DECORATIVE ART POLE, CONDUIT /WIRING AND ALL ASSOCIATED EQUIPMENT. INSTALLATION OF THE RISER ASSEMBLY AND POST -TOP GLOBE BY OTHERS. FOR INSTALLATION DETAILS, SEE ELECTRICAL DETAILS SHEET 274, ILLUMINATION PLANS (CONDUIT TRENCH DETAIL), COR STANDARD DRAWINGS J013 AND SPECIAL PROVISIONS. O CONSTRUCT WALL WITH ANCHOR BOLTS PER UBRAN DESIGN DETAIL SHEETS 269 -272. FURNISH AND INSTALL DECORATIVE ART POLE, CONDUIT /WIRING AND ALL ASSOCIATED EQUIPMENT ON TOP OF THE WALL. INSTALLATION OF THE RISER ASSEMBLY AND POST -TOP GLOBE BY OTHERS. FOR INSTALLATION DETAILS, SEE ELECTRICAL DETAILS SHEET 274, ILLUMINATION PLANS (CONDUIT TRENCH DETAIL), COR STANDARD DRAWINGS J013 AND SPECIAL PROVISIONS. O FURNISH AND INSTALL IN- GROUND LED LUMINAIRE, CONDUIT /WIRING AND ALL ASSOCIATED EQUIPMENT PER "IN- GROUND LED LUMINAIRE LAYOUT DETAIL ", ELECTRICAL DETAILS SHEET 274. IN- GROUND LED LUMINAIRES SHALL BE FIELD LOCATED IN THE PRESENCE OF THE ENGINEER AND THE ARTIST. SEE SPECIAL PROVISIONS. ® INSTALL NEW JUNCTION BOX TYPE 1 PER "JUNCTION BOX LAYOUT DETAIL ", URBAN DESIGN DETAILS SHEET 271. LID SHALL BE LABELED "LT". O FOR CONTINUATION OF CONDUIT /WIRING, SEE ILLUMINATION PLANS. © LOCATION OF POWER SOURCE. SEE ILLUMINATION PLANS FOR CONSTRUCTION NOTE, WIRING AND DETAILS. O TERMINATE CONDUIT FOR IN- GROUND LED LUMINAIRES IN DECORATIVE ART POLE. SPLICE IN- GROUND LED LUMINAIRE WIRING INTO DECORATIVE ART POLE CIRCUIT. T- 3430213 I 11.1411 SURVEYED: KPG >� CITY OF RENTON ( ) �P>s�w °sn. 7t�� ,� RAINIER AVENUES SR 167 DRAWING NO. 273 'f DRAWN BY: JHL ii Re 9 BID "� S GRADY WAY TO S 2ND ST PROJECT NO. TED403430 _ z DESIGN BY: JHL 7539th AvenueN 2562 Jefferson Avenue Public Works Department FED AID NO. - CM0167(048) CHECK BY: JC Sege, WA 98109 Tacoma, WA 98462 DOCUMENTS ELECTRICAL PLAN AND DETAILS A 39324 2� APP FOR CONSTRUCTION DATE: NOV 2011 PROJ MGR: JF (2061286.1640 (253)627 -0720 " "COm BY: DATE: SW GRADY WAY INTERSECTION SHEET NO. 273 OF 304 NUMBER REVISION DESCRIPTION BY APP. DATE FILE: Details.dwg : a a z n `] a r'] m /r ti O =C N�a a � o :IJ o w N O a a z n `] a r'] m /r ti O =C N�a a � o :IJ o w N O