Loading...
HomeMy WebLinkAboutT-3430232�i I� 0 N 3 a Y IRRIGATION SCHEDULE SYMBOL MANUFACTURER MODEL NO. DESCRIPTION 9 RAINBIRD SURVEYED: KPG DRAWN BY: EM DESIGN BY: EM CHECK BY: EG PROJ MGR: JF FILE: 0655DIRR01.dwg BUBBLER SERIES -1402 FULL- CIRCLE FLOOD BUBBLER - INSTALL PER DETAIL SHEET 293. RAINIER AVENUES (SR 167) S GRADY WAY TO S 2ND ST IRRIGATION SCHEDULE AND DETAILS ES RAINBIRD 1800 -15 STRIP SERIES SHRUB HEAD - 6" PLASTIC POP -UP. 5'x15', 5'x30' AT 30 PSI. SIDE & END STRIP NOZZLE, INSTALL ON FLEXIBLE RISER EST SST A 0 RAINBIRD 1800 -15 STRIP SERIES LAWN HEAD - 6" PLASTIC POP -UP. 5'x15', 5'x30' AT 30 PSI. SIDE & END STRIP NOZZLE, INSTALL ON FLEXIBLE RISER VA 8H RAINBIRD 8 SERIES MPR SHRUB HEAD - 6" PLASTIC POP -UP. ADJ TO 8' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER 8Q e m m RAINBIRD REVISION DESCRIPTION 12 SERIES MPR LAWN HEAD - 6" PLASTIC POP -UP. ADJ TO 12' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER DATE 120 12H 12F 1E�i a RAINBIRD 12 SERIES MPR SHRUB HEAD - 6" PLASTIC POP -UP. ADJ TO 12' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER t � C RAINBIRD 15 SERIES MPR SHRUB HEAD - 6" PLASTIC POP -UP. 15' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER 15Q 15H 15F U o @ RAINBIRD 15 SERIES MPR LAWN HEAD - 6" PLASTIC POP -UP. 15' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER 15Q 15H 15F SENTINEL SATILUTE (2) 24- STATION OUTDOOR CONTROLLERS (A & B), STAINLESS STEEL PEDESTAL MOUNTED WITH CONCRETE IR TORO A- SSAK24PS16NS1 FOUNDATION. SEE SIGNAL PLANS FOR ELECTRICAL SERVICE. PROVIDE 3 SPARE WIRES (RED) FROM CONTROLLER B- SSAK24PS16NS1 THROUGH EACH CONTROL VALVE BOX, TO FURTHEST VALVE BOX FROM CONTROLLER. PROVIDE TELEPHONE LINE TO CONTROLLERS FOR TELEPHONE MODEM. WEATHERMATIC 2100 AUTOMATIC CONTROL VALVE - SIZE AS NOTED ON PLAN. POC -A POINT OF CONNECTION EQUIPMENT, APPROX. STA 26 +65, 50' RT. SEE DETAILS THIS SHEET AND SHEET 293. X FEBCO 850 1 1/2" DOUBLE CHECK VALVE. Q WEATHERMATIC 2100 1 1/2" MASTER SHUTOFF VALVE AND TORO TS FLOW SENSOR QO RAINBIRD 44 -LRC 1" BRASS QUICK COUPLER VALVE WITH LOCKING VINYL COVER. INSTALL PER DETAIL. INSTALL ONE AT DOUBLE CHECK VALVE ASSEMBLY. 1 1/2" IRRIGATION METER. SEE WATER PLANS FOR MORE INFORMATION. POC -B POINT OF CONNECTION EQUIPMENT, APPROX. STA 35 +82, 44' LT. SEE DETAILS THIS SHEET AND SHEET 293. X FEBCO 850 1 1/2" DOUBLE CHECK VALVE. 0 WEATHERMATIC 2100 1 1/2" MASTER SHUTOFF VALVE AND TORO TFS FLOW SENSOR O RAINBIRD 44 -LRC 1" BRASS QUICK COUPLER VALVE WITH LOCKING VINYL COVER. INSTALL PER DETAIL. INSTALL ONE AT DOUBLE CHECK VALVE ASSEMBLY. M 1 1/2" IRRIGATION METER. SEE WATER PLANS FOR MORE INFORMATION. - - PVC SCH 40, IRRIGATION MAIN LINE - 24" MIN COVER PVC SCH 40, LATERAL SUPPLY LINE- 18" MIN. COVER - SIZE AS NOTED. - - - - - SLEEVING, PVC SCHEDULE 40, SIZE TWICE INSERT PIPE DIA. iS 1F A INDICATES VALVE & CONTROLLER # "A" OR "B" INDICATES CONTROLLER A OR B 10.5 INDICATES APPROX. GPM "1S" INDICATES VALVES FOR STREETSCAPE PLANTER ZONES. 1" INDICATES VALVE SIZE "1F" INDICATES VALVES FOR FILTERRA /TREE GRATE ZONES. IRRIGATION MAIN LINE DOUBLE CHECK VALVE PRESSURE REDUCING VALVE MASTER SHUT OFF VALVE AND FLOW SHUT OFF VALVE INSTALL IN SEPARATE VALVE BOX - IRRIGATION METER N =H 1" QUICK COUPLER VALVE TO PRESSURE MAIN NOTE: CONNECTION TO PRESSURE MAIN SHALL NOT BE MADE UNTIL IRRIGATION MAIN LINE IS PRESSURE TESTED. TYPICAL POINT OF CONNECTION ASSEMBLY NTS c c LL L LL (t SIDE ELEVATION POC VALVE BOX IRRIGATION GENERAL NOTES 1. COORDINATE INSTALLATION OF IRRIGATION SYSTEM WITH INSTALLATION OF OTHER QUICK COUPLER UTILITIES, INCLUDING JOINT TRENCH AND FILTERRA UNITS. LOCATE AND PROTECT (2) STAINLESS STEEL CLAMPS ALL UNDERGROUND UTILITIES DURING INSTALLATION OF IRRIGATION SYSTEM. TO STAKE 2, IRRIGATION SYSTEM SHALL BE INSTALLED, TESTED, MAINTAINED AND GUARANTEED P.V.C. NIPPLE 3' #4 REBAR STAKE AS PER SPECIFICATIONS. 3. IRRIGATION SYSTEM IS DESIGNED TO OPERATE FROM 30 PSI. CONTRACTOR SHALL FIELD CHECK EXISTING WATER PRESSURE, ADJUSTING PRV AS NECESSARY TO 360' PVC TRIPLE SWING JOINT PROVIDE OPTIMUM PERFORMANCE. P.V.C. PRESSURE MAIN 4. LOCATIONS OF IRRIGATION MAIN LINE, LATERALS, SLEEVING AND VALVES INDICATED ON DRAWINGS ARE SCHEMATIC ONLY. ADJUST LOCATIONS AS NECESSARY. DO PVC TEE OR ELBOW WITH NOT OVERSPRAY ONTO PAVED SURFACES. THREADED OUTLET 5. IRRIGATION MAIN LINE LOCATION IS DIAGRAMMATIC. LINE SHALL BE PLACED IN PLANTING AREAS WHERE EVER POSSIBLE. 6. MAIN LINE SHALL BE BURIED TO A DEPTH OF 24" BELOW FINISH GRADE. LATERAL LINE FOR SPRAY ZONES SHALL BE BURIED TO A DEPTH OF 18" BELOW FINISH QUICK COUPLER OR GRADE. LATERAL LINE FOR BUBBLER ZONES SHALL BE BURIED TO A DEPTH OF 12" SPRINKLER BODY BELOW FINISH GRADE. 360' PVC TRIPLE SWING JOINT PVC THREADED TEE AT 7• SLEEVE UNDER ALL PAVED SURFACES, CONCRETE SIDEWALK AND BETWEEN FILTERRA MAINLINE UNITS AND SIDEWALK. SEE IRRIGATION PLANS FOR LOCATION OF PVC SLEEVING, SLEEVING SHALL BE 2 TIMES THE DIAMETER OF THE INSERT PIPE AND WIRES. SECTION THROUGH MAIN LINE QUICK COUPLING VALVE/ TRIPLE SWING JOINT NTS NOTE: ALL THE FITTINGS AND PIPE TO BE SAME DIA. AS IPS FEMALE CONNECTION OF QUICK COUPLER/ SPRINKLER HEAD INSTALL IN DCVA BOX QUICK COUPLING VALVE, SEE DETAIL THIS SHEET PVC I COPPER BACK TO METER 8. CONTROLLER WIRES SHALL BE TAPED TOGETHER IN A BUNDLE AT 10' INTERVALS. SNAKE WIRE IN BOTTOM OF PIPE TRENCH WHERE POSSIBLE. WHERE PIPE TRENCH IS UNAVAILABLE WIRES SHALL BE PLACED IN SLEEVING. WIRES TO CONTROLLER SHALL BE PLACED IN 1" / 1.5" SLEEVE, USE 3M DBY SPLICE KITS. 9. ALL EQUIPMENT SHALL BE AS SPECIFIED OR APPROVED EQUAL BY CITY OF RENTON. SYSTEM IS SPECIFICALLY DESIGNED FOR IRRIGATION EQUIPMENT SHOWN ON PLANS AND SUBSTITUTION WILL REQUIRE REDESIGN AND RECALCULATION OF IRRIGATION ZONES. 10. NO GALVANIZED FITTINGS. ONLY BRASS OR SCH 40 PVC SHALL BE USED. 11. IRRIGATION TRENCHING NEAR ANY TREES TO REMAIN SHALL BE DONE WITH THE MINIMUM AMOUNT OF DISTURBANCE POSSIBLE. TRIM AND CUT CLEAN ANY EXPOSED OR DAMAGED ROOTS. FINISH GRADE ALL FITTINGS PVC L- J PVC IRRIGATION MAIN ° °OO , �O O °°o• °° °0 °OQ °.. o0 °O °° ° ° _ ° 0. ° . STACKED METER BOXES PER CITY OF RENTON STANDARDS. SIZE TO FIT EQUIPMENT. COMPACT BACKFILL APPROVED DOUBLE CHECK VALVE, INSTALL PER CITY OF RENTON STANDARDS. COPPER UNION AND PIPE PRESSURE REDUCING VALVE 0 J LL II f 111 1 PRESSURE MAIN CONNECT 1�--� TO MASTER SHUT OFF VALVE (INSTALLED IN 8" MIN DEPTH PEA SEPARATE BOX) GRAVEL, WITH FILTER FABRIC INSTALL ASSEMBLY IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN - 340.8. SEE POINT OF CONNECTION ASSEMBLY, THIS SHEET. DETAIL DOUBLE CHECK VALVE ASSEMBLY NTS T- 3430232 a z m a j�•j n /1I O ro a � o w K a .p 0 0 0 z 1 �j k -mow va�iawa Q 3�6 i 5 11 -14,11 o a aLL w SURVEYED: KPG DRAWN BY: EM DESIGN BY: EM CHECK BY: EG PROJ MGR: JF FILE: 0655DIRR01.dwg gp04k BID 75391h AvenueN 2502 Jefferson AV¢0U¢ SeatOe, WA 98109 Tacoma, WA 98402 DOCUMENTS (206128&1640 253621 -0720 ( 1 www.kpg.00m e. CITY OF RENTON Public Works Depa tment APP VED FOR CONSTRUCTION ;/ / BY: DATE � /�L RAINIER AVENUES (SR 167) S GRADY WAY TO S 2ND ST IRRIGATION SCHEDULE AND DETAILS DRAWING NO. 292 PROJECTNO. TED403430 FED AID NO. - CM0167(046) DATE: NOV 2011 SHEET NO. 292 OF 304 NUMBER REVISION DESCRIPTION BY APP. DATE a z m a j�•j n /1I O ro a � o w K a .p 0 0 0 z