Loading...
HomeMy WebLinkAboutR-372412POLYPROPYLENE TYPE 2 60" DIA MANHOLE STEPS 12" CONTROL CB WITH FLOW 3 - 8' 0 3' 0 ACCESS RISERS 5 SPACED (TYP) RESTRICTOR DETENTION PIPES r(TYP AT FACH PIPE) Cg 1LIMITS OF CONCRETE SLAB 36" PIPE 8' 0 BULKHEAD 4 "0 ELBOW 4 RESTRICTOR WITH - - - 1.04 "0 ORIFICE 2.00' M - °o TYPE 2 54" DIA CB REQUIRED FOR THIS JUNCTION i SHEAR GATE WITH ROD FOR CLEANOUT PER CITY OF TYPE 2 60" DIA CONTROL 40.00' P N 237.30TON STD CB WITH FLOW RESTRICTOR 66.00' j. 8.00' 12 "0 RISER 23 C5.2 \8' DIA DETENTION CONTROL STRUCTURE PLAN TANK 2 SCALE: 1" = 2' 12" THICK CONCRETE SLAB 8" THICK CONCRETE SLAB FRAME GRATE AND LOCKING TYPE 2 60" DIA ACCESS RISERS TYPE 2 60" DIA MANHOLE COVER PER CITY CONTROL CB WITH PROPOSED GRADE C8.1 CONTROL CB WITH FLOW STD DET 204.50 FLOW RESTRICTOR 12" DIA PIPE RESTRICTOR 36° DIA PIPE C8.1 RISER ELEV 367.00 0 SEDIMENT LEVEL POLYPROPYLENE I o TYPE 2 54" DIA CB MANHOLE STEPS 12" IE ELEV 365.10 IE ELEV 359.50 u? ------ __ - -_- ° ___________ _ __ IE ELEV 365.50 SPACED (TYP) IE ELEV 359.47 ELEV 359.00 ELEV 359.00 z 8' DIA DETENTION IE ELEV 359.47 3 - 8'0 DETENTION TANK PIPES TANK 230' LONG, PROVIDED MIN O DETENTION VOLUME OF 11,069 CF RISER OVERFLOW (W /O 0.5' OF SEDIMENT STORAGE). ELEV 367.00 - SEE NOTE 1 FOR PIPE MATERIAL DETENTION TANK NOTES 1. DETENTION TANKS SHALL BE: TOP ORIFICE •ALUMINIZED TYPE 2 CORRUGATED STEEL PIPE (AASHTO ELEV 365.10 M274 AND M36) • STEEL REINFORCED POLYETHYLENE PIPE (DUROMAXX OR 3 TOP ORIFICE 'q SIMILAR) 0 1 04„ z DETENTION TANKS PLAN AND SECTION 5 �SCALE: 1" = 10' 2. DETENTION TANK PIPE SHALL HAVE A WATERTIGHT JOINTS. - LU 3. ALL METAL PARTS SHALL BE CORROSION RESISTANT, STAINLESS z STEEL OR ALUMINUM. ALL GALVANIZED PARTS TO HAVE ASPHALT SHEAR GATE z TREATMENT 1. 4. SEE ALSO CITY OF RENTON STD PLAN 235.00 - TYPICAL DETENTION m 11.00' TANK AND STD PLAN 235.10 - DETENTION TANK ACCESS DETAIL O w TYP PROPOSED FOR MORE DETAILS. - o z GRADE IE OUT ELEV 359.47 o z v PAVEMENT SECTION C8.1 0 - - a - N IE ELEV 359.50 IE ELEV 359.00 BOTTOM ORIFICE w a M IE ELEV 359.47 E SELECTED GRANUAL FILL PER ELEV 357.47 PIPE M AASHTO M145 Al, A2, OR A3, OR o z SUPPORT 8" THICK LEAN CONC MIX APPROVED EQUAL PLACED IN 8" BOTTOM ORIFICE LL (1,500 PSI MIN) W / #4 LIFTS (COMPACTED TO MIN 90% STD 0 0.41" BARS ® 24" O.C. DENSITY PER AASHTO T99 ° TRANSVERSE DIRECTION > (12" THICK AT NOTE: 72412 BULKHEAD) SEE CITY OF RENTON STD PLAN 237.00 '° FLOW RESTRICTOR AND 237.30 FROP -T R=3 SHEAR GATE FOR DETAILS NOT SHOW CONTROL STRUCTURE SECTION 2 HERE. IL 3.00 3 SCALE: 1" = 2' E TYP PIPE GRANULAR BEDDING MATERIAL, ROUGHLY SHAPED o TO FIT THE BOTTOM OF PIPE, 4" TO 6" IN DEPTH ri (REMOVE ANY UNSUITABLE FOUNDATION MATERIAL AS v APPROVED BY GEOTECHNICAL ENGINEER) N ,1 DETENTION PIPE BEDDING AND BACKFlLL Q �TJSCALE: 1" = 5' Call before you dig 0 o a IN COMPLIANCE WITH CITY OF RENTON S RDS BY: DATE: _ q Iq BY:-- DATE: BY: DATE: Abossein Engineering, L. L. C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH (425) 462-9441 FAX (425) 462 -9451 E_ Mail cservice @obossein.com www.cibossein.com WENDYS 10619 SE CARR ROAD RENTON, WA 98055 WENDYS STORE NO. 10542 NEW RESTAURANT E2000- 2013 -UM -T1 ULTRA MODERN 412'1/1+ Vq oy` xa a 30419�Ve' E2000- 2013 -UM T1' 9 -12 -2013 JOB No. SHEET No.' 2130871 C5.2 I R z 0 "n ND 0 a 0 ' w w U U 3 w U U a. N f/l O H F W O O w W w w N M m K K '. m im O N O O N O N N N N '� O .r N M •.1' N '. J y IL a a ',......'.. E ~ LL W ° J M � _ w V N v o s� m Z I v! � Z W H W W z D ' 0 U) WENDYS 10619 SE CARR ROAD RENTON, WA 98055 WENDYS STORE NO. 10542 NEW RESTAURANT E2000- 2013 -UM -T1 ULTRA MODERN 412'1/1+ Vq oy` xa a 30419�Ve' E2000- 2013 -UM T1' 9 -12 -2013 JOB No. SHEET No.' 2130871 C5.2 I R z 0 "n ND 0 a 0