CITY OF RENTON GENERAL WATER NOTES
1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON PLANNING /BUILDING /PUBLIC
WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT /APWA
STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY
OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF
APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING
CONSTRUCTION.
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO
8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN
WRITING BY THE PUBLIC WORKS DEPARTMENT AT (425) 430 -7301. THE
z POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24
HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY.
w
0 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT
Of
CL SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND
CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY
LOCATES CALL 48 -HOUR LOCATORS 800- 424 -5555.
4. NOT USED
5. NOT USED
6. ALL WATERMAIN
PIPE IS TO BE CEMENT
LINED DUCTILE IRON
PIPE
CONFORMING TO
AWWA C110 AND C111
OR LATEST REVISION,
THICKNESS
CLASS 52. CEMENT MORTAR LINING AND
SEAL COATING SHALL
CONFORM TO
AWWA C104 OR
LATEST REVISION. PIPE
JOINTS TO BE PUSH -ON
OR
MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND
FITTINGS SHALL
BE POLYETHYLENE WRAPPED PER ANSI /AWWA
C105/A21.5 -93
STANDARDS.
7. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED,
PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH
ANSI /AWWA C110/A21.10 -87. CEMENT LINING SHALL BE IN ACCORDANCE
WITH ANSI /AWWA C104/421/4 -90. IF FITTINGS ARE 3 TO 12 INCHES IN
DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN
ACCORDANCE WITH EITHER ANSI /AWWA C110- A21.10 -87 OR ANSI /AWWA
C153/A21.53 -94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH
HAVE MECHANICAL JOINTS AND /OR FLANGED JOINTS, SHALL BE IN
ACCORDANCE WITH ANSI /AWWA C110/A21.10.87 OR A COMBINATION OF
ANSI /AWWA C110/A21.10.87 AND ANSI /AWWA C153/A21.53 -94 SUCH THAT
THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH
ANSI /AWWA C153/A21.53 -94 AND THAT PORTION OF THE FITTING WITH
FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10 -87.
ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI /AWWA
SECTION 10 -4.3 OF ANSI /AWWA C110/A21.10 -87 SHALL BE OBTAINED BY
THE CONTRACTOR AND TRANSMITTED TO THE OWNER.
8. GATE VALVES SHALL BE IRON BODY, BRONZED - MOUNTED, DOUBLE DISC
WITH BRONZE WEDGING DEVICE AND 0 -RING STUFFING BOX (AWWA C500)
OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED
FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES
SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M & H.
9. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR
COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA
C- 502 -85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE
OPENING (M.V.O.) OF 5 -1/4 INCH, TWO 2 -1/2 INCH HOSE NOZZLES WITH
NATIONAL STANDARD THREADS 7 -1/2 THREADS PER INCH AND ONE 4 INCH
PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH,
60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND
ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1 -1/4 INCH PENTAGON
OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT).
10. THE TWO 2 -1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON
THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND
PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH
SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST
PRESSURES.
11. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4
INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE
FORGED AND /OR EXTRUDED 6061 -T6 ALUMINUM ALLOY, HARDCOAT
ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET
SCREWS 180 DEGREES APART. SLORZ FACE TO BE METAL, NO GASKET TO
WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND
SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED,
STAINLESS STEEL, AIRCRAFT CABLE.
PORTION OF: SE 1/4 & NE 1/4 OF THE SW 1/4, SECTION 04, T. 23 N., R. 05 E., W.M.
12. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT.
PRESERVATIVE PAINT NUMBER 43 -655 SAFETY YELLOW OR APPROVED
EQUAL.
13. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY.
14. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD
DETAIL FOR FIRE HYDRANTS, LATEST REVISION.
15. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM
COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12
INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW
FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO
BE LOWERED TO CLEAR.
16. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE
CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE
"POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR
APPROVED EQUAL, 2 LB /CU. FT. DENSITY FOAM WITH 90A DUROMETER
URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY.
17. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE
END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION.
18. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A
MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN
ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND
THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING
SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY
OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL
NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY
OF RENTON STANDARD PLANS & SPECIFICATIONS 7- 11.3(11). THE
LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR
TEST PERIOD.
19. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE
INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE /WATER
SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE
PIPE AS LAID. CHLORINE SHALL BE METERED /INJECTED IN ACCORDANCE
WITH SECTION 7- 11.3(12)E OR 7- 11.3(12)F OF THE STANDARD
SPECIFICATIONS REFERENCED ABOVE.
20. A PRE - CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY
CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS
REQUIRED FOR SCHEDULING.
21. NOT USED
22. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL
NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION.
23. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND
METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER
APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE
BEEN MADE TO THE CITY OF RENTON.
24. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE
CITY OF RENTON, EXCEPT WET TAPS, WHICH MAY BE MADE BY
APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE
PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND
MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE
ON -SITE PRIOR TO CITY NOTIFICATIONS.
25. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE
CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE
OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS
THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS.
26. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF
ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL
TIE-IN.
27. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.)
SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY
OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC
WORKS DEPARTMENT.
DESIGN COMPANY
1205 SECOND AVE. SUITE 200
SEATTLE, WA 98101
T 206.223.0326
F 206.223.0125
NWW.BV d..ig.x..
NO.
REVISION
28. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A
MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAY BE SPADE
CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS,
AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH
OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT.
29. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE
DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE
PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR
SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. *
BY I DATE I APPR
BENCHMARK
JZ
CITY OF RENTON
Approved by: Date: lb zAl p
Approved by:
Approved by:
Approved by:
R- 310605
Date:
Date:
Date:
PLEASE CALL 811
3 Working Days
BEFORE YOU DIG
0,
U
w
cr
cr
O
U
IL
CITY OF RHA KIRKLAND AVENUE 10/23/201
RENTON TOWNHOMES
RENTON, WA 98056
Planning /Building /Public Works Dept. CITY OF RENTON NOTES G1.4
CD ` f-)l -37060 s
AS NOTED
xaw win iew w,
°t�Hp1
DATUM
N FULL SGIE
i ,q! O,E INOI
A'NE .YSCRpNQY
CITY OF RENTON
Approved by: Date: lb zAl p
Approved by:
Approved by:
Approved by:
R- 310605
Date:
Date:
Date:
PLEASE CALL 811
3 Working Days
BEFORE YOU DIG