HomeMy WebLinkAboutS-337210M1Gw,JIV,VJ: N N U i N U �7 `1 Q G W Q w LL Z 0 L a Uw lo 4 1I 44 � Q O r Z zz O =R Z 6y u !I?do< F S?f N w ofz PORTION OF THE S.E. 114, 8 . 1147 SECTION 4, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. SAWARY SEWER NOTES 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSOOT/APWA STANDARDS AND SPECIFICATIONS. 2 THE HOURS OF WORK IN THE STREET RIGHT -OF -WAY SHALL BE LIMITED TO 8 :30 A.M. TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS AT (425) 430 -7200. ALL STREET CLOSURES PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION (APWA), LATEST EDITION AND CITY OF RENTON STANDARD SPECIFICATIONS.. 4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 5. A PRECONSTRUC77ON CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STAR77NG CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY 774E UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. Z IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 8. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS W77H A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, 7740ROUGHLY TAMPING EACH LAYER TO 95% OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO 774E SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 12. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A CONTINUOUS LINE A TEMPORARY COLD MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFlLL AND COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF CURRENT CITY OF RENTON STANDARDS. 13. DATUM SHALL BE CITY OF RENTON, NAVE) 1988 (METERS) AND NAD 198311991 (METERS). 14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR 0774ERMSE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVEN77ON OF ON -SITE EROSION AFTER 774E COMPLETION OF CONSTRUCTION. 15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7- 02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE 16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D3034, SDR 35, SDR, C900 OR DUC77LE IRON CLASS 50. SANITARY SEWER FORCE MAIN TO BE CEMENT LINED DUC77LE IRON PIPE CONFORMING TO LATEST REVISIONS OF AWWA C110 & C111, THICKNESS CL.52 17. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM 18 INCH ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. ALL MANHOLES SHALL HAVE LOCKING LIDS. 18. ALL SANITARY SEWER IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH 774ESE APPROVED PLANS. ANY DEVIATION FROM THESE PLANS WILL REQUIRE APPROVAL FROM THE OWNER, ENGINEER AND APPROPRIATE PUBLIC AGENCIES. 19. LOCA7IONS OF ROADWAYS, BUILDINGS AND PARKING AREAS SHOWN HEREON ARE APPROXIMATE. FOR DIMENSIONED LOCA77ONS OF THESE IMPROVEMENTS, REFER TO THE ARCHITECTURAL SITE PLAN. IMPROVEMENT AND STRUCTURE LOCATIONS SHALL BE FIELD SET BY THE ENGINEER AS REQUIRED. 20. ALL - MANHOLES SHALL BE PER THE CITY OF RENTON STANDARDS AND SPECIFICATIONS. ALLMANHOLES SHALL HAVE A MINIMUM 0.10 -FOOT TO MAXIMUM 1.0 -FOOT DROP BETWEEN INVERT IN AND INVERT OUT. ALL MANHOLE COVERS SHALL BE ADJUSTED TO FINISH GRADE PRIOR TO FINAL PAVING AND LANDSCAPING. , 21. ALL TRENCH BACKFlLL SHALL BE COMPACTED TO AT LEAST 959 OF THE MAXIMUM DRY DENSITY PER AS7M 0- 1557 -70 (MODIFIED PROCTOR), FOR THE FIRST THREE FEET ABOVE THE PIPE. THE REMAINING BACKFlLL MAY BE TO 90% IF NOT IN AN AREA OF FUTURE PAVEMENT OR STRUCTURAL FILL. TRENCH BACKFlLL AND COMPAC77ON SHALL BE COMPLETED PRIOR TO TESTING LINES FOR LEAKAGE. 22. ALL SIDE SEWERS SHALL BE A MINIMUM 6" DIAMETER AND HAVE A MINIMUM SLOPE OF 2.07. PROPERTY / LOT CORNERS AND / OR BUILDING LOCATIONS AND FINISH GRADES SHALL BE ESTABLISHED IN THE FIELD PRIOR TO ANY SEWER CONSTRUCTION. SIDE SEWER TEE STATIONS ARE REFERENCED FROM THE NEAREST DOWNSTREAM MANHOLE THE CONTRACTOR SHALL MAINTAIN ACCURATE AS -BUILT RECORDS OF ALL SIDE SEWER LOCATIONS. ALL SIDE SEWERS SHALL BE TESTED AT 714E TIME OF MAIN LINE TESTING. PIPE MATERIAL SHALL BE C900 FOR DEPTHS OVER 15'. 23. WHERE A WATER MAIN CROSSES ABOVE THE SANITARY SEWER, AND LESS THAN SO OF VER77CAL CLEARANCE EXISTS BETWEEN THE TOP OF SEWER AND BOTTOM OF WATER MAIN, THE SEWER SHALL BE CONSTRUCTED OR RECONSTRUCTED WITH DUCTILE IRON PIPE (CLASS 50) FOR A MINIMUM HORIZONTAL DISTANCE OF 10' ON EACH SIDE OF THE WATER MAIN CROSSING. 24. SANITARY SEWER MAIN LINES (8" DIAMETER AND LARGER) SHALL NOT BE CONSTRUCTED ANY CLOSER THAN 10 FEET TO ANY BUILDING OR 5 FEET TO ANY CARPORT. 25. NEW CONNECTIONS TO EXIS77NG FACIU77ES SHALL BE SEALED OFF UNTIL UPSTREAM CONSTRUCTION IS FINISHED, TESTED, CLEANED AND ACCEPTED. ALL CONSTRUCTION DEBRIS AND WATER SHALL BE REMOVED PRIOR TO OPENING THE SEAL. ALL TESTING SHALL BE IN THE PRESENCE OF A CITY OF RENTON INSPECTOR. 26. PRIOR TO ACCEPTANCE OF CONSTRUCTION AND / OR ISSUANCE OF OCCUPANCY PERMITS, ENGINEER / SURVEYOR - CERTIFIED AS -BUILT DRAWINGS MUST BE PREPARED OF ALL SANITARY SEWER FACILITIES. 27. INSTALL FALL RESTRAINT SYSTEM IN ALL SANITARY SEWER MANHOLES OVER 20 -FEET DEEP. FALL RESTRAINT SYSTEM SHALL BE "SURETRACT CLIMBING AND FALL PROTECTION SYSTEM ", AS MANUFACTURED BY "MILLER FALL PROTECTION '. 1:3:5 MIX CONCRETE BLOCKING NOTES: 1. Al 4,aivb "No tl Fft C Fie 9•. 24). zWUpa��.rpm°aa��,aa�ooa°•�'o.a°'s.�a -u°. � ara e�e�'°.Y°' SaquFN by F1oNS4 Ma a dw�A nw me ee� e. v wa'°R MORTAR FILLET MANHOLE FRAME AND COVER SEE DRAWING BR29 (SP PAGE 6074) ADJUSTMENT (4" MIN.) CONE RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C -443 STEPS - 314" DEFORMED BAR STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL MAIL PIPE SIZE - 'E' LADDER -STD. ALUMINUM OR GALVANIZED STEEL CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. SANITARY MANHOLE TYPICAL DETAIL NOT TO SCALE �PMWN Z5 60" ALLOWABLE MAX. FOR CAST IRON PIPE OR DUCTILE IRON PIPE. / GOB _2_% MIN SLOPE HORIZONTAL �6"SIDE OUTLET TEE SEWER MAIN 6" MIN. SEWER MAIN CONCRETE SLOCXCAVO ANQLE TYPICAL SIDE SEWER ELEVATION OF TEE AT MAIN OVER 25 EL&W NOTE= UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. ADOPTED 0 CITY OF RENTON Standard plans LST DATE: 12196 STANDARD SIDE SEWER INSTALLATION (SEWER MAIN TO PROPERTY LINE) DWG. NAME : BR39 SP PAGE : 8078 aDDPTED ® an- or m,os 'D' 'E' 48" MH 1 48" 6 INCH OR 8 INCH CLEANOUT Wl WE: WIN s P. :W. MORTAR FILLET MANHOLE FRAME AND COVER SEE DRAWING BR29 (SP PAGE 6074) ADJUSTMENT (4" MIN.) CONE RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C -443 STEPS - 314" DEFORMED BAR STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL MAIL PIPE SIZE - 'E' LADDER -STD. ALUMINUM OR GALVANIZED STEEL CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. SANITARY MANHOLE TYPICAL DETAIL NOT TO SCALE �PMWN Z5 60" ALLOWABLE MAX. FOR CAST IRON PIPE OR DUCTILE IRON PIPE. / GOB _2_% MIN SLOPE HORIZONTAL �6"SIDE OUTLET TEE SEWER MAIN 6" MIN. SEWER MAIN CONCRETE SLOCXCAVO ANQLE TYPICAL SIDE SEWER ELEVATION OF TEE AT MAIN OVER 25 EL&W NOTE= UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. ADOPTED 0 CITY OF RENTON Standard plans LST DATE: 12196 STANDARD SIDE SEWER INSTALLATION (SEWER MAIN TO PROPERTY LINE) DWG. NAME : BR39 SP PAGE : 8078 NOTES: 1. STEPS TO BE 314" 0 DEFORMED BAR GALVANIZED SAFETY STEPS OR EQUAL Z STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. J. CASTING TO BE PER DRAWING BR29. 4. MANHOLE SEC77ONS TO BE OF REINFORCED PRECAST CONCRETE 5. ALL JOINTS SHALL BE GROUTED. 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC- CONSEAL OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C -443. 8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 314 THE INSIDE DIAMETER OF THE LARGEST PIPE. 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR -N -SEAL BOOTS OR APPROVED EQUAL 10. MANHOLES EQUAL TO AND GREATER THAN 20 FEET DEEP SHALL HAVE A "SURETRACK" CLIMBING AND FALL PR07ECTION SYSTEM INSTALLED. ADOPTED ®� CTTY OF RENTON Standard plans LST DATE: 04/08 SANITARY MANHOLE TYPICAL DETAIL DWG. NAME: BR28 SP PAGE : B071 PROPERTY LINE 2 FUTURE 6" BUILDING SEWER PIPE 7!T BUILDING SEWER , - - - - - -- r - �o - - - - -- TEE WITH 6" SIDE OUTLET UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, Dl PIPE AND Cl PIPE SEWER MAINS ARE TO BE CORE DRILLED 5- 331210 zl �I w) 0 a 2 "x 4" S77JD SERVICE MARKER PAINT UPPER PORTION WHITE ANS STENCIL ON SIDE WORDING "SEWER" WITH 3" HIGH BLACK LETTERS. AND #6 WIRE WRAPPED AROUND THE STUD AND EXTENDED TO THE TOP OF THE STUD. SIDE SEEVIERI�D�E/T�AIL _ g7a77 L FOR APPROVAL BY: BY: CO OD �3 0 W m L� I �W 7 Ch�Z aO20 X20 m0 w/� N'1 NW2/4 T W (LL V LL V J IL tou 0 lg t9 • U � bA wT � •TN� •ri p..l to o LTa \: Uw 3 OD Q FD J n Xa I,L 0 Q Q 2 LL 2mWhN ILW _ _j�2� ro Q op3s W 8�ma GJ7W <I`= 00a PROJECT NO.: 12007 DRAWN BY: VK ISSUE DATE: 12/05/06 SHEET REV.: 07/19/2012 SANITARY SEWER DETA -8 AND NOTES O6035DTO4- C20.DWG SHEET 21 OF 29 °. h1 °> �a> o � � r ny � w N 'A' 1 6' 1 'C' 'D' 'E' 48" MH 1 48" 1 6" MIN. I 5 59N 1 24" MIN. 1 21" I.D. 54" MH 1 54" 1 8" MIN. 5.5" MIN. 1 24" MIN. 1 24" I.D. 60" MH 1 60" 1 8" MIN. 1 6" MIN. 1 42" MIN. 1 30" I.D. NOTES: 1. STEPS TO BE 314" 0 DEFORMED BAR GALVANIZED SAFETY STEPS OR EQUAL Z STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. J. CASTING TO BE PER DRAWING BR29. 4. MANHOLE SEC77ONS TO BE OF REINFORCED PRECAST CONCRETE 5. ALL JOINTS SHALL BE GROUTED. 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC- CONSEAL OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C -443. 8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 314 THE INSIDE DIAMETER OF THE LARGEST PIPE. 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR -N -SEAL BOOTS OR APPROVED EQUAL 10. MANHOLES EQUAL TO AND GREATER THAN 20 FEET DEEP SHALL HAVE A "SURETRACK" CLIMBING AND FALL PR07ECTION SYSTEM INSTALLED. ADOPTED ®� CTTY OF RENTON Standard plans LST DATE: 04/08 SANITARY MANHOLE TYPICAL DETAIL DWG. NAME: BR28 SP PAGE : B071 PROPERTY LINE 2 FUTURE 6" BUILDING SEWER PIPE 7!T BUILDING SEWER , - - - - - -- r - �o - - - - -- TEE WITH 6" SIDE OUTLET UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, Dl PIPE AND Cl PIPE SEWER MAINS ARE TO BE CORE DRILLED 5- 331210 zl �I w) 0 a 2 "x 4" S77JD SERVICE MARKER PAINT UPPER PORTION WHITE ANS STENCIL ON SIDE WORDING "SEWER" WITH 3" HIGH BLACK LETTERS. AND #6 WIRE WRAPPED AROUND THE STUD AND EXTENDED TO THE TOP OF THE STUD. SIDE SEEVIERI�D�E/T�AIL _ g7a77 L FOR APPROVAL BY: BY: CO OD �3 0 W m L� I �W 7 Ch�Z aO20 X20 m0 w/� N'1 NW2/4 T W (LL V LL V J IL tou 0 lg t9 • U � bA wT � •TN� •ri p..l to o LTa \: Uw 3 OD Q FD J n Xa I,L 0 Q Q 2 LL 2mWhN ILW _ _j�2� ro Q op3s W 8�ma GJ7W <I`= 00a PROJECT NO.: 12007 DRAWN BY: VK ISSUE DATE: 12/05/06 SHEET REV.: 07/19/2012 SANITARY SEWER DETA -8 AND NOTES O6035DTO4- C20.DWG SHEET 21 OF 29 °. h1 °> �a> o � � r ny � w N