HomeMy WebLinkAboutS-373205DR
,08
)8
.08
L08
.08
LOS
108
w
z
U
w
'o
w
a
NE 114, NW 114, SEC.14, TWP.23N., RGE. 5E., W.M.
w SEE C4.01 CONSTRUCTION NOTES
O 1 '�,.I ----- - - - - -' — — — — \ 1 I % I �� �I SLOPE PER CDR STD. PLAN 406.1 AND 403.1 IN.
I \
O 6" SIDE SEWER CONNECTION W /CLEANOUT, 2% M
I \ \ I \
W i V A \I v - A j ! 2 48" SANITARY SEWER MANHOLE TYPE 1 W/ FRAME AND
J I \ I I \ �� I o \ I \I. '/` O COVER PER CDR STD. PLAN 400.1 AND 401
12 IZ i I v 1113 �v 14 v i v
FFE =49 0 i \� FFE =4 -.7 \ FFE =496.5 \ to \\ \\\ @��\ ; '��I 3O SANITARY SEWER CLEANOUT PER CDR STD. PLAN 403.1
SAWCUT EXIST. PVMT.
T 6 SIDE SEWER TO MANHOLE PER COR
CONNECT " S STD.
PLAN 406.1
w
� . I -
I I II I \ GENERAL NOTES:
,? I LANDSCAPE AND UTILITY TRACT 1 \\ \= I \
j - — _ - �f I \ 11 I \ FEET BELOW THE FINISHED FLOOR ELEVATI).
Y • -
- 2. PIPE BEDDING FOR SANITARY SEWER MAIN BE PER
cc
13- �- .- ..�_�� �� ,! ° ___- ,-- -- _ _ ��� COR STD. PLAN 405.
_ s� - - _ _, _ __�
Q - - `- t_ - - -- I - - , - -- • 3. ALL SANITARY SEWER MANHOLES ARE TYPE CDR
:� ILL, _.. \I. ... STD. PLAN 400.1 AND 401.
_ / _ -` -- - — - , �— - - -- 1 — - -'\ - - - \ .\ \ 4. PAVEMENT RESTORATION SUBJECT TO FIELFICATION
- _ - \ -— BY THE CITY INSPECTOR.
�,�: �V� — 14tQJ{ /_. _ - - - -- _ �b�F- T-- -.— C„ _ .... Wl // - / �� \\ / .i \� oC
T..- J o
w -='� --.1� �-- tp_ -= - \ / - - - - -' 5. PER CITY OF RENTON TRENCH RESTORATIOILS, IF E
ENT -� _ _ _ -- , n +, 4l IH►T - -�__ - ENTIREIADJACENTi17RAVEL LAAFFECTED EE, TH
J ] C _ �.. _
Q. -- --- -. SSi; _� °"i
Q = 9,E27 E�7AL ✓S7REJ -1 — J �'` .- -.. ` SS 'SS�Tgg _..... J=- 75rJ� _� --- �- -- - - -1Z + — -_ REPAVED.
-- -_
�` -- SS - -r
\ - -' -L` - `* -- -- _._� - - -- ____o - -SS SS SS a \ - - - - -- - -� -_ 6. IF THERE IS LESS THAN 12 INCHES SEPARBETWEEN
�• \ \ � \ -- —v= — - -- —� (D SS�� --� S AT CROSSLI N ETHAFORSHALL B -- -R _ ' UTILITY PIPE NE, A E
4 �_ _� y \ 'i - — — — — -
- — -'rte -' - - -- -
e
�_
rvJ �� , . a � oe r� o \ Cc/ DISTRICT
S - - -' G - SEE KC WATER IMPROVEMENT
I _
5
P�'
NO. 90 CONSTRUCTION PLANS \�
�.k oe I � —
J
500 �Z1 500
y>
2¢
M3 .
0
^o
490 N= FINISH GRADE ® 490
h
iornn EXISTING GRADE ROADWAY ¢ S=3 7 3J ®ROADWAY +
05 480 3 u w - - /-8' WATER MAIN _ - - -.- - °- 480 -
470 - -_ - -- - 470 " '° e e v
-
460 V�
460 Q sam,aa.nms y
SE!sr V, ?vc p NE,?NQSTREET'.
SEWER 1J,4iN D;
NTS
450 450 KEYMAP
�S
440 0
440
a
r
h r
E,C37630�00 Q� CP H
m 0 h h +o m a ,n ,o NW N W ._ ro `tW •-
06 n n Wro W m O N N �7 �; vl ` ^ .O O O FP a.S^O Y.: N N,'�^'���'� M cy . amp .s. .�
CONSULTANTS
�� �� ��� �� -0� �� �� 7
Re Planning•Crvil Engineering
' C�OU DIGS Land Use Consulting• Project Management
13 +20 13 +60 14 +00 14 +40 14 +80 15 +20 M5 +60 18 +OQ 16 +40 •16 +80 17 +20 ® 1- 800.4245555 7337MAVmue,8ve. 1001 KftrA WA98M
mate(425)2 M901FAK(425)2852389
www.cDhconsultants.com
0 10 20 CITY OF RENTON 1 CITY OF RENTON PERMIT SUBMITTAL JBS� _5 D 4 J ;? y HAN "„ MAPLEWOOD PARK EAST / /
yKN /A xae¢axu,: xe ,ossoo, �� 5 30 14
Approved by:j,} Date: n scAnib r a _,. CITY 0 F ROADWAY GRADING, DRAINAGE AND SANITARY SEWER IMPROVEMENTS
OVERT. 20 IN FEET UTILITY PERMIT Approved by: Date: .. RENTON :
_ PETER EVANS _ . DATUM tl1'� "a
HORIZ IN FEET NO. U13002729 Approved by: Date: / JAMIE B. CHROEDER, PE " r�rior`u`o Planning /Building /Public Works Dept. SANITARY SEWER PLAN AND PROFILE C4.05
cw„�®rtozov3cxx consutrono. uc. at rti�s xesa.. a.A rovedb Dale: 6 St2,J NO. REVISION BY DATE. APPR APo '�"E" y s,¢r. ar:
APPROVED 29 36
NNNNAA
ci
a
r
a �
O
0
�m0
a
D
H