Loading...
HomeMy WebLinkAboutzT-3732 SetZ U LLI w Y a O >O Lu J d Q O O + h = (n W WO Z Co �Q = W �(n Q MATCH LINE STA 0 +50 SEE SHEET IL2 ZI �. 4 I ;i ;r\ Q uti \ -fir S ?v Ei ck- \\ .�co ,t r NE 114, NW 114, SEC.14, TWP.23N., RGE. 5E., W.M. MATCH LINE STA 20 +75 SEE SHEET IL2 3 I Z 1 it j I i 4 I 12 +00 13 +00 -- - - -. 14 +00 - R/W ILLUMINATION LEGEND EXISTING NEW DESCRIPTION m Q JUNCTION BOX TYPE 1, 2 0_ - STANDARD DAVIT POLE X DECORATIVE POLE - - - -- CONDUIT /CONDUCTOR ® SERVICE CABINET O CONSTRUCTION NOTE O LUM. POLE NO. QWIRE NOTE ss O + W (n 0 15 Z m - - - -- s W LAJ ILLUMINATION CONSTRUCTION NOTES OINSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET ILIA, AND PER CITY OF RENTON STD PLANS 115, 119, 120, 121, & J013. (D OINSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET ILIA, AND PER CITY OF RENTON STD PLANS 116.1, 119, 120, & 121. OCONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STD PLAN 126.1. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STD PLAN 122.1 & 123. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. O4 EXISTING STREET LIGHT POLE TO REMAIN. (D OPOWER SOURCE CONNECTION POINT UNKNOWN AT THE TIME OF PLAN PREPARATION. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO PROVIDE 1201240 VOLT SINGLE PHASE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL HOOK -UP, SHALL PREPARE /SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY ALL ASSOCIATED FEES. STATIONS /OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH ENGINEER PRIOR TO IMPLEMENTING. *s TO BE NUMBERED AT THE TIME OF CONSTRUCTION. ILLUMINATION WIRING SCHEDULE Q RACEWAY SIZE CONDUIT SERVICE /2 ILLUMINATION POLE SCHEDULE 1 2" SCH40 PVC 2" SCH40 PVC SPARE LUM. w4l POLE I.D. s MOUNT. SERVICE WATTAGE LUMINAIRE TYPE - BASE COMMENT 2" SC H40 PVC POLE NO. STREET NO *y STATION OFFSET 2" SCH80 PVC HEIGHT CIRCUIT TYPE DISTRIBUTION 6 2" SCH80 PVC 2 1 ATB2 40BLEDE70 MVOLT R3 NL FIOLE PER RENTON STD PLAN 115. SE 132 ST - 11 +33.5 16.5' LT 25' ILLUM A 94 LED 700mA DRIATB2 rM 40OLEDE70 MVOLT R3 NL FIXED NEW POLE PER RENTON STD PLAN 115. SE 132 ST - 13 +14.0 16.5' LT 25' ILLUM A 94 LED 700mA DRIATBFIXED NEW POLE PER RENTON STD PLAN 115. SE 132 ST - 14 +87.5 16.5' LT 25' ILLUM A 94 LED 7pOmA DRIVER ATB2 40BLEDE70 MVOLT R3 NL FIXED NEW POLE PER RENTON STD PLAN 115. 4O SE 132 ST - 16 +02.0 16.5' LT 25' 240 8' ILLUM A 94 LED 700mA DRIVER B PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. O ROSARIO AVE N - 1 +11.5 15.0' RT 14' 240 - ILLUM 44 LED CY17T4- VS3AR- 3L- 44W -4K O NE 2 LANE - 30 +46.5 12.5' LT 14' 240 - ILLUM B 44 LED PRESTIGE CY17T4- VS3AR -3L- 44W -4K FIXED NEW POLE PER RENTON STD PLAN 116.1. PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. 7O NE 2 LANE - 31 +45.0 12.5' RT 14' 240 - ILLUM B 44 LED CY77T4- VS3AR -3L- 44W -4K PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. BO NE 2 LANE - 32 +43.0 12.5' LT 14' 240 - ILLUM B 44 LED CY17T4- VS3AR -3L- 44W -4K PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. 9O NE 2 LANE - 33 +37.5 12.5' RT 14' 240 - ILLUM B 44 LED CY77T4- VS3AR -3L- 44W -4K f0 NE 2 LANE - 34 +32.0 12.5' LT 14' 240 - ILLUM B 44 LED PRESTIGE CY17T4- VS3AR -3L- 44W -4K FIXED NEW POLE PER RENTON STD PLAN 116.1. PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. if SHADOW AVE NE - 22 +91.0 16.5' LT 14' 240 - ILLUM B 44 LED CY17T4- VS3AR -3L- 44W -4K 12 SHADOW AVE HE - 21 +95.5 16.5' RT 14' 240 - ILLUM B 44 LED PRESTIGE CY77T4- VS3AR -3L- 44W -4K FIXED NEW POLE PER RENTON STD PLAN 116.1. 13 SHADOW AVE NE - 21 +08.5 16.5' LT 14' 240 - ILLUM B 44 LED PRESTIGE CY77T4- VS3AR -3L- 44W -4K FIXED NEW POLE PER RENTON STD PLAN 116.1. STATIONS /OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH ENGINEER PRIOR TO IMPLEMENTING. *s TO BE NUMBERED AT THE TIME OF CONSTRUCTION. ILLUMINATION WIRING SCHEDULE Q RACEWAY SIZE CONDUIT SERVICE /2 N0. 1 2" SCH40 PVC 2" SCH40 PVC SPARE w4l 2 2" SCH80 PVC 2" SCH80 PVC SPA3 2" SC H40 PVC 2" SCH80 PVC 5 2" SCH40 PVC 6 2" SCH80 PVC 2 1 s OTHLK GUNUUII MAT UL rrtcacnr N PJ" L/ �'p (,e" /r. i 10 40 0 20 60 SCALE IN FEET i- 373201 %9TENW Transportation Engineering Northwest r�sew�ononN nvl OnmluoiBC.roa�a0oaaioa r.:o s =. em ixon�. s..m m eaa..o. wn veca l o�m lcsl5avar.r Peve:.]5]17YA[ c�- � 7 -3 1 z � Z U W o Y a � O W J 30 +00 NE 114, NW 114, SEC.14, TWP.23N., RGE. 5E., W.M. 2 N I 11 , L_ Ji 3 r I n yr. t�_2 i 3 R W 3 2 3 2 - I B > -- I b' 31 +0�- - - - — )� _ _ S = _ T-- R W 3 _ - -- - /i - - N' 1 33 +00+ - - -_ - -- IN I 2 LA _ - - - /r I �Z 3 - - R1W / ; w r > s I p I - 2 I - 9 ILLUMINATION CONSTRUCTION NOTES �i o 2 GENERAL NOTES II� Q INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION W I 3 5 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF OPOLE SCHEDULE, SHEET ILIA, AND PER CITY OF RENTON STD PLANS 115, 119, 3 THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA 120, 121, & J013. N W STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL INSTALL FOUNDATION POLE LUMINAIRE AND JUNCTION BOX PER ILLUMINATION > TIMES DURING CONSTRUCTION. - I Q OPOLE SCHEDULE, SHEET ILIA, AND PER CITY OF RENTON STD PLANS 116.1, 119, � O . + l V 2. THE HOURS OF WORK IN THE STREET RIGHT -OF -WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. 2 120, & 121. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. I '! CONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STD PLAN 126.1. 1 - i ItII ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC O WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STD PLAN 122.1 & 13 ' NOTIFIED 24 HOURS IN ADVANCE. 123. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE O VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE 3 �I! O4 EXISTING STREET LIGHT POLE TO REMAIN. o° CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID x ' I DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48 -HOUR LOCATORS, 1- 800 - 424 -5555. POWER SOURCE CONNECTION POINT UNKNOWN AT THE TIME OF PLAN 31 I� 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING OPREPARATION. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO PROVIDE 1201240 VOLT SINGLE PHASE POWER SOURCE. 3 3 NEW CONSTRUCTION. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SECURE ALL NECESSARY I PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL �, I i• HOOK -UP, SHALL PREPARE /SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ALL ASSOCIATED FEES. I I I NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. MATCH LINE STA 0 +50 SEE SHEET I0 ILLUMINATION LEGEND EXISTING NEW DESCRIPTION m D JUNCTION BOX TYPE 1, 2 o- STANDARD DAVIT POLE x DECORATIVE POLE - - - -- CONDUIT /CONDUCTOR ® SERVICE CABINET O CONSTRUCTION NOTE O LUM. POLE NO. QWIRE NOTE 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. B. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR. 10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL AT THE EARLIEST POSSIBLE DATE. 11. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10 -FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. ILLUMINATION WIRING DIAGRAM i1 W W Z Z 6 8 10 > NE 2 LANE 12 > Q 7 9 Q 0 3 O Q 5 Q N SERVICE 1 2 ILLUM A N LJ ILLUM B 1 2 3 4 SE 132ND ST NOT TO SCALE 4 MATCH LINE STA 20 +75 SEE SHEET IL 1 T=373202 SERVICE BREAKER SCHEDULE CIRCUIT BREAKER CONTACTOR MAIN 2P -100 AMP - -- ILLUM A 2P -20 AMP 30 AMP ILLUM B 2P -20 AMP 30 AMP 10 40 0 20 60 SCALE IN FEET VTENW Transportation Engineenng Northwest uorvpgrahnlbrip I CerV: I uolK 4rpocr ep�paXS'a uwis em snmr. sr.m:w eMa.,ra.w Chrt Lc'et vc onuo Igsl aevem Fcgcl Ca.ac 4 r. P E. p.rx¢: a1S]SOYA1 Cam •' T- 3'? 3 ;)La Z DID 4 (n R- Q U w W 'O0 Y o cr- ^Q I.L >0 W ^J ICL L 0.188 WALL BRACKET ALUM. ALLOY 6063 -T6 1/2- ERIC DR. 18 -8 RUSH JOINT 4 -1 2 O.D. TAPERED ALUM. POLE 0.188 WALL ALLOY 6063 -T6 SATIN GROUND FINISH _ SIZE AS PEQUIRED e'er SLIPFTTTER 5 9 H ADIUS 18' -3' 23' -3" 28'-3' 33 3 SHAFT 25' -0" 0 151 HATCHOLL d -x 6" OPENING W /COVER AND S. 5' SCREWS 8. CO. I BASE FLANGE ALLOY 356 -T6 ME, :RIUNQ LUG BOLT COVERS & S.S. SCREWS AD -5 1.-11 -1/4- SO. 11- TO 12 01 A. BOLT CIRCLE -� d V' OF BOLT ABOVE d' CONCRETE PAD FlN'SHEO CP.ADE (d) 1'x42' ERIC CALV. STEEL S ANCHOR BOLTS LATH NUTS y AND WASHERS 4 PUBLIC WORKS STANDARD 26' -40' DAVIT POLE em. PLAN – us DEPARTMENT Dvto 6 11 l :�F T STREET LGHT POLE \ `JUNCTION Box PLAN VIEW I 4' DEEP SIDE VIEW LIGHTING STANDARD & JUNCTION BOX NOTE.. CLASS 'S' CONCRET_ TO BE USED N CONSTRUCTON OF PAD ci 1 PLAN VIA' �y INDIVIDUAL JUNCTON BOX PUBLIC WORKS CONCRETE PAD DETAILS DEPARTMENT 1 NE 114, NW 1/4, SEC.14, TWP.23N., RGE. 5E., W.M. [-T 1 �.. .... ..1.. ., INY I w,.. POLE ELEVATION FOUNDATION DETAILS _ NET PLAN - 116.1 A� PULL 'if, xORF;F PEDESTRIAN LUMINREET H'iR,IH DBPART9F:%.P PLURE AND POLE DETAILS FIXTURE AND POLE DETAILS r =1 MOUNTING HEDEH 15 TET 2 -]/8" TO 3' INSTALL DECAL NUMBERS VERTICALLY. INSTALL M DRY WEATHER, 50' E OR ABOVE. NUMB EXAM0.ESV PLAN VIEW LED TYPE WATTAGE DECAL REFLECTORIZEC GOTHIC GOLD OR WH11E LEGEND ON BLACK BACKGROUND PUBUC WORKS STREET LIGHT STANDARD 9M. PLAN - 121 (s I I Q DEPARTMENT DECAL NUMBERING SYSTEM PROJED 11wpla' On. LN'I[o r.mo[ lawwc w sTI g11r ArcF eo[ Tn[s R • z Axow PlM ,- .u.o -RR _ Ywl 4[a 0.1M emu'[ �['lixi }s ox Au l � ' caPw- wauuo �c J 'EST Sm TCH Irs[ ..s wa Puax[c. I ucq Ira lug furs S[C [W4 pWxD tW — UA°i x uuresrsrt aas To rulxcTx— w j IYRR AS R[rco.l ruwwPnOx fAMq.Y [wiR 4xo xW NOTES 1. EQUIPMENT GROUND ERE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE ME POLE HANDHCLL. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 2, IF THE FIXTURE MANUFACTURER HAS MADE PROVISION FOR THE ATTACHMENT Of A GROUND ERE A GREEN INSULATED ERE OF THE SAME. SIZE SHALL BE RUN FROM THE FIXTURE TD 1HE GROUND LUG INSIDE THE POLE HANDHOLL IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A 18 GREEN INSULATED ERE SHALL Of RUN FROM THE FIXIURi. GROUND LUG TO THE POLE GROUND LUG. PUBLIC WORKS TYPICAL LIGHTING DEPARTMENT UNDERGROUND SYWMM TEPonNAL mn .c Roo n LuLI l .. yR[5 "Al MIFF M A p[RO C & /E IX IE. rJOUH.:w STREET LIGHTING CONTACTOR CABINET N9RING SCHEMATIC TYPE III SERVICE 120 /240 VOLT 10.'S' u-ok, EREAKER (MIN.) au m rc BRANCH 'BEAKERS lvo /aAO voLT 16 POLE POLE UTUTY PLLC (CFI) • lZp41-j ORCUIT NiRE5 TC LIG-Tp'C RUNS i NXOTO -CET: TO G40UN0 NNIEO Qu POD NEAREST LUMINXflE 1YRING COLOR CODE A. WHITE JACKET (NEUTRAL) B. BACK JACKET (LINE) C. GREEN JACKET (GROUND) D. RED JACKET (LOAD) E GREEN OR BARE ERE (GROUND) PUBLIC WORKS STREET LIGHTING CONTACTOR &m. PLAN - 128 DEPARTMENT CABINET SCHEMATIC / i- 373103 qwa- TEN W Transporlation Engineering NorlhWest tlwpawlm HO.tq I [bpi E IAlfic Mpxl a opvolue I IaOJSE 01p Slrapl. iule%P. &fo'.w, NIP VWL OIICn 4E51 �dL1 Rgec Cmlocl: 2M1 GRpI. P.E. C'/ - 1 - --s / ; W Q Z U W K a V/ W Y d O w J Q NE 1/4, eceu uLe WE TO M 9SE TO .O CABAET 1A8 1E. tiI— M1L— • -� G'e J h �i-.� FIR G, -JEn SPi NLe 0 D" 11E 10 For NOTES see Sid. Plan 126.2 s- J E ,.,. i n� O ° dz° 1 m O 1 t y� 1 w a N � 2.ALNiW Lpn UNT IFR PAO . MOAKIN i f Ixf11TRN For NOTES see Sid. Plan 126.2 s- J E ,.,. PUBLIC WORKS I CABINET FOUNDATION DETAILS DEPARTMENT TWP. 5E., W.M. A t DIAMETER - 7 /E' FUSE KIT EPDXY FILL ,TR INLINE SPLICE EPDXY FILL WYE SPLICE SPLICE KIT FUSE KR k SPLICE KIT DEPAIIS ALIN"^OPfEim.Ten nAxwvp vwo is wx o.�a DWG. NAME: J013 SP PAGE: J013 N BAP( O. C N:Tw CAOMET AOOAC=1 L. 1/3 f• t1TTER5. y �j1}p m II• r unwrc e 42 %6 AWG is AWG Q e s N GND Q o o° �n 0 0 o I FD9A55. IIaDi11AL PMTK • I I usm a� _-{.;� _� � —, " l DY2R6 �L_ y� J PA N[A&E r i5e CVIff¢SS W MAW "t01 1W1 MIEU G1 YJ%i t LEST rA •tat AC :R REan�icPh —: u„p.¢ u.uwATw OF �SIFAD 1 Sam TITtfFf m = LEFTo t SIDE FRONT VIEW n.o Nc,T c ° WAS RUSE NOTE: LOAD CURRENT FOR ALL BREAKER NO- -0 EXCEED BO: OF BREAKER AMPERAOc 10.� INCLOa1WlF Ga101101aTIDM IIOR�Y iWAApu .0 A, rlN ]l FwMr. ILI . vrt w5 w mc6.0 , nwo5 frm. . uwn .u+n w. ww. ra aut¢ or ana+c AO,[crwao mrnc mR w w.n pHy wmAn[ v . (one u W Rte. [me o- c.a auaar ,. .. ca m o m5. e.... . re AA � WA` iWMAW � e ...n Lea• . IAam.. AM. to r.n5n w .a [wrr m Atprm r BASE PLAN I AA T- 313204 fTENW Transportation Engineering Norlhwest Irnrtp'rlalm M1n4p I LMT I Lpl4 hpa[Ib OJnaly¢ I LW SFB:n SUm:. Su:n iS Bd'owo. wP 9&W I On[o PS511Widm Rggc:Cmrx::CNi. pit. e:. P E. PMVw: gS]56YA1 C� - —r - 3'� 3 2.0 y n� O ° dz° 1 m O 1 t y� 1 w a N � n P1L.]Ea PATIFRY RACMUP PAO MO[WT St STEW (TIPS) iOL._ I1110H PUBLIC WORKS I CABINET FOUNDATION DETAILS DEPARTMENT TWP. 5E., W.M. A t DIAMETER - 7 /E' FUSE KIT EPDXY FILL ,TR INLINE SPLICE EPDXY FILL WYE SPLICE SPLICE KIT FUSE KR k SPLICE KIT DEPAIIS ALIN"^OPfEim.Ten nAxwvp vwo is wx o.�a DWG. NAME: J013 SP PAGE: J013 N BAP( O. C N:Tw CAOMET AOOAC=1 L. 1/3 f• t1TTER5. y �j1}p m II• r unwrc e 42 %6 AWG is AWG Q e s N GND Q o o° �n 0 0 o I FD9A55. IIaDi11AL PMTK • I I usm a� _-{.;� _� � —, " l DY2R6 �L_ y� J PA N[A&E r i5e CVIff¢SS W MAW "t01 1W1 MIEU G1 YJ%i t LEST rA •tat AC :R REan�icPh —: u„p.¢ u.uwATw OF �SIFAD 1 Sam TITtfFf m = LEFTo t SIDE FRONT VIEW n.o Nc,T c ° WAS RUSE NOTE: LOAD CURRENT FOR ALL BREAKER NO- -0 EXCEED BO: OF BREAKER AMPERAOc 10.� INCLOa1WlF Ga101101aTIDM IIOR�Y iWAApu .0 A, rlN ]l FwMr. ILI . vrt w5 w mc6.0 , nwo5 frm. . uwn .u+n w. ww. ra aut¢ or ana+c AO,[crwao mrnc mR w w.n pHy wmAn[ v . (one u W Rte. [me o- c.a auaar ,. .. ca m o m5. e.... . re AA � WA` iWMAW � e ...n Lea• . IAam.. AM. to r.n5n w .a [wrr m Atprm r BASE PLAN I AA T- 313204 fTENW Transportation Engineering Norlhwest Irnrtp'rlalm M1n4p I LMT I Lpl4 hpa[Ib OJnaly¢ I LW SFB:n SUm:. Su:n iS Bd'owo. wP 9&W I On[o PS511Widm Rggc:Cmrx::CNi. pit. e:. P E. PMVw: gS]56YA1 C� - —r - 3'� 3 2.0 y D ro rn m O ° dz° 1 m O y� 1 w a N