Loading...
HomeMy WebLinkAboutR-371711Z 0 U Q W M TRACT "A" DRAINAGE 6934 SF PUBLIC --- I ------ . -O+- - -S 1 TI d_ I � I I I I T3 SF I GRAPHI SCALE _ 20 0 10 20 10 ee ( IN FEET ) 1 inch 4 20 ft. LOT 2 4508 SF VERTICAL DATUM NAVD 88 BENCHMARK TOP OF FOUND CONCRETE MONUMENT AT THE S.E. CORNER OF SECTION 32 ELEV. = 514.98 FT (WCCS POINT ID NO. 3831) 18.05' LT BEGIN 10:1 TAPER SIDEWALK TRANSITION (SEE DETAIL 3 -014) STA 10 +00 - 22' LT BEGIN VERT CURB /WALK- LOT 6 I I 4513 SF ; RELOCATE SCHOOL BEACON STA 10 +67.11 -25.71 RT I INSTALL TYPE 2 J -BOX STA 10 +64.19- 23.85' RT PROVIDE 12 "W X 6 "D CONIC PAD AROUND J -BOX SAWCUT PVMNT. WEST OF LOOP I I STUBOUT (SEE NOTES) I I ; I 1 I 1 I I I II L — it ^ 0 +5 /' LOT 1 4678 SF 5.00' CONIC CONC. SIDEWALK — TRANSITIONS STA BJOIN-EXISTING -_END CURB _ - S7A- Pf +b3.40 -2TC1" -- END NEW SIDEWALK MATCH EXISTING EL 500.0± - NO. NE 1/4 OF SE 1/4 OF SEC. 32, TWP. 23N., RGE. 5E., W.M. EXIST. SCHOOL BEACON CAMERA ASSY & CONTROLLER CABINET. I. ADD PHOTO ELECTRIC o ��Q CELL AND STREET o-f UGHT CIRCUIT. �'P SEE ILLUMINATION PLANS S EET TREE EXIST. 2" CONDUIT W/1 -3/C#8 ( ICAL) / 2- 2/C #14, 1- 2/C #12. I I 2" CONDUIT W/1 -3/C#8 C #14, 1- 2/C #12. EXIST. 2" CONDUIT W /2 -3 /C #8. PSE TRANSFORMER AND METER PEDESTAL )X LOCATION (SEE LOCATED APPROX 250' SOUTH OF CAMERA ASSY o +oo INTERSECTION STA 10 +93.30 -116TH SE o- = STA 0 +00 -SE 86TH o I I I I� 2 . 0' I ' STREET TREEI ' (TYPICAL) I i i i I m I ADJUST TO GRADE (TYP) +1 I II ILLUMINATION REVISION BACK OF PROPOSED CURB EXIST. BEACON 6.0 NEW J -BOX - -- - - 72 n , RELOCATED BEACON EXISTING JBOX EXIST. CONIC PAD LAYOUT PLAN 1"=5' NOTE THE LOCATION OF ALL EXISTING SHOWN HAGENSON MXACT DETERMINE THE LOCATIINU01HFALLEXISTINGRUTI ES BEFORE COMMENCING WORK. CONTRACTOR AGREES TO BE FULLY CONSULTANTS, LLC LOCATE AND AND PRESS RVE AANY AL UUNDERGHWND UTILITIES. CIVIL ENGINEERING & LAND DEVELOPMENT CONSULTANTS 6484 -48TH AVE SW Seattle WA 98126 CALL 48 HOURS phone 206 938 -6168 fax 206.938 -7645 email H.Hagwwn000MCAST.NET BEFORE YOU DIG 1- 800 -424 -5555 18.05' LT BEGIN 10:1 TAPER SIDEWALK TRANSITION (SEE DETAIL 3 -014) STA 10 +00 - 22' LT BEGIN VERT CURB /WALK- LOT 6 I I 4513 SF ; RELOCATE SCHOOL BEACON STA 10 +67.11 -25.71 RT I INSTALL TYPE 2 J -BOX STA 10 +64.19- 23.85' RT PROVIDE 12 "W X 6 "D CONIC PAD AROUND J -BOX SAWCUT PVMNT. WEST OF LOOP I I STUBOUT (SEE NOTES) I I ; I 1 I 1 I I I II L — it ^ 0 +5 /' LOT 1 4678 SF 5.00' CONIC CONC. SIDEWALK — TRANSITIONS STA BJOIN-EXISTING -_END CURB _ - S7A- Pf +b3.40 -2TC1" -- END NEW SIDEWALK MATCH EXISTING EL 500.0± - NO. NE 1/4 OF SE 1/4 OF SEC. 32, TWP. 23N., RGE. 5E., W.M. EXIST. SCHOOL BEACON CAMERA ASSY & CONTROLLER CABINET. I. ADD PHOTO ELECTRIC o ��Q CELL AND STREET o-f UGHT CIRCUIT. �'P SEE ILLUMINATION PLANS S EET TREE EXIST. 2" CONDUIT W/1 -3/C#8 ( ICAL) / 2- 2/C #14, 1- 2/C #12. I I 2" CONDUIT W/1 -3/C#8 C #14, 1- 2/C #12. EXIST. 2" CONDUIT W /2 -3 /C #8. PSE TRANSFORMER AND METER PEDESTAL )X LOCATION (SEE LOCATED APPROX 250' SOUTH OF CAMERA ASSY o +oo INTERSECTION STA 10 +93.30 -116TH SE o- = STA 0 +00 -SE 86TH o I I I I� 2 . 0' I ' STREET TREEI ' (TYPICAL) I i i i I m I ADJUST TO GRADE (TYP) +1 I II ILLUMINATION REVISION BACK OF PROPOSED CURB EXIST. BEACON 6.0 NEW J -BOX - -- - - 72 n , RELOCATED BEACON EXISTING JBOX EXIST. CONIC PAD LAYOUT PLAN 1"=5' R -37111 CHECK FOR COMPLIANCE TO CITY STANDARDS SCHOOL BEACON RELOCATION PLAN LAKESIDE FAIRWOOD PLAT 18621 - 116TH AVE SE RENTON, WASHINGTON LAKESIDE INVESTMENTS, LLC 7 -14 -14 C11 IN- ININININIAIAI # i n CONSTRUCTION NOTES 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON DESIGN STANDARDS AND SPECIFICATIONS, THE APPROPRIATE STATE ELECTRICAL CODES AND THE PROVISIONS OF THE LATEST EDITION OF THE IES LIGHTING HANDBOOK. 2. ALL WORK ON THE SCHOOL BEACON SYSTEM SHALL BE COMPLETED BY LICENSED CONTRACTORS EXPERIENCED IN THE INSTALLATION OF ILLUMINATION SYSTEMS. 3. THE CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND COORDINATE INSPECTION WITH THE CITY, STATE AND POWER COMPANY AS REQUIRED. 4. CONTRACTOR SHALL CONTACT THE CITY INSPECTOR A MINIMUM OF 24 -HOURS PRIOR TO COMMENCING WORK ON THE UGHTING SYSTEM. 5. CONTRACTOR TO PROVIDE AND INSTALL NEW ILLUMINATION CIRCUITS FROM SCHOOL BEACON PSE METER THROUGH BEACON CONTROLLER CABINET AND CONTINUING ON TO STREET LIGHTS. PROVIDE 2 POLE 20 AMP BREAKER ON NEW STREET LIGHT CIRCUIT IN EXISTING CONTROLLER CABINET. SEE ILLUMINATION PLANS. 6. CONTRACTOR TO COORDINATE WITH SITEWORK CONTRACTOR. SAWCUT FOR PAVEMENT WIDENING SHOULD BE MADE WEST OF LOOP DETECTOR STUB OUT, IF EXISTING LOOPS ARE DAMAGED THEN CONTRACTOR SHALL REPLACE PER "BENSON HILL ELEMENTARY SCHOOL" BY AMERICAN TRAFFIC SOLUTIONS PLANS DATED 7 -10 -2013. 7. CONTRACTOR TO PROVIDE CONTINOUS RUNS BETWEEN JUNCTION BOXES. NO SPUCES WILL BE PERMITTED. USE EXISTING PIGTAIL IN EXISTING BEACON JUNCTION BOX TO INSTALL NEW TYPE 2 J -BOX PER PLAN. IF PIGTAIL IS OF INADEQUATE LENGTH, PULL REPLACEMENT CONDUCTORS AS NECESSARY. IF LOOP DETECTOR PIGTAIL IS OF INADEQUATE LENGTH, THEN REPLACE LOOPS PER NOTE 6 ABOVE. 8. CONTRACTOR TO COORDINATE WORK NTH CITY OF RENTON. BENSON HILL ELEMENATARY SCHOOL SUMMER SESSION RUNS THROUGH AUGUST 8TH. CITY WILL PROVIDE TEMPORARY SIGNING AS NECESSARY. HEH 23 14 " 1 " =20' ° °°' S. CITY 0 F 23- RENTON H 19 1 HEH HEH /13/, °Pw"" HEH 30 13 HEH oxE Ixcx DATUM HEH D=T1 13 "HEH Planning /Building /Public Works Dept. IF ME Ntl1 BY DATE APPR nFFenrom"`' E " HEH R -37111 CHECK FOR COMPLIANCE TO CITY STANDARDS SCHOOL BEACON RELOCATION PLAN LAKESIDE FAIRWOOD PLAT 18621 - 116TH AVE SE RENTON, WASHINGTON LAKESIDE INVESTMENTS, LLC 7 -14 -14 C11 IN- ININININIAIAI # i n