Loading...
HomeMy WebLinkAboutW-343027S 3RD PLACE WATER MAIN CROSSING PROFILE -RAINIER AVE S STA 41 +00 GENERAL WATER CONSTRUCTION NOTES I JLr 1. EXISTING WATER MAINS, HYDRANTS, AND SERVICES SHALL REMAIN OPERATIONAL THROUGHOUT SURVEYED. HPc DRAWN BY. SOD DESIGN BY so0 CHECK BY NJD PROJM D JF FILE LBSGWATPFW1.d�y THE COURSE OF CONSTRUCTION EXCEPT WHERE WATER BYPASS SYSTEMS ARE REQUIRED. FOR All CITY OF RENTON "N P„eu�wo,ks DaPaamam APPROVED FOR CONSTRUCTION DY. DATE. RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST WATER PROFILE S 4TH PL AND S 3RD PL CROSSINGS INSTALLATION OF WATER BYPASS SYSTEMS SEE TEMPORARY WATER BYPASS PLANS, SHTS 60 160 -163. ABANDONMENT AND /OR REMOVAL OF EXISTING MAINS SHALL TAKE PLACE ONLY ..................................................................................................................................... ............................... ..... ............................... .......... ............................... ...... AFTER THE NEW MAIN OR WATER BYPASS SYSTEM HAS BEEN INSTALLED TESTED, AND EX. GAS, INV. UNK. CONTR. TO VERIFY LOCATION &DEPTH EX, GAS, INV. UNK. APPROVED BY THE CITY OF RENTON. EX. UNDERGROUND POWER, INV. UNK. CONTR. TO VERIFY LOCATION & DEPTH 2. MAIN SHUTDOWNS SHALL BE BY CITY MAINTENANCE STAFF ONLY. CUT —IN CONNECTIONS TO UNK. OFFER. TO VERIFY LOCATION & DEPTH REVISION DESCRIPTION BY APP. DATE EXISTING MAINS SHALL ALSO BE PERFORMED BY CITY STAFF. CONTRACTOR SHALL PROVIDE FE'pEH EX. 12" STORM DRAIN, IE:U NK RAINIER AVE 5 STA 33+ 9.2 TWO WEEK ADVANCED NOTICE TO CITY FOR SCHEDULE OF CONNECTIONS AND SHUTDOWNS. CONTE. TO VERIFY LOCATION & DEPTH REDUCER, 12' TO B' 3. EXISTING SERVICE LINES, METER SETTERS, AND METER BOXES ARE TO BE REPLACED AS PART RAINIER AVE S STA CONNECTION TO S 43H 33 +92.2 PL OF THIS PROJECT. EXISTING METERS ARE TO BE RESET WITHIN THE NEW SETTERS. COORDINATE 40 ........................... .............................40 W /CITY OF RENTON. ........qp: 4. DEFLECT JOINTS AS NECESSARY TO INSTALL WATER MAIN WITH MINIMUM COVER ALONG THE RAINIER A TE 5 APPROXIMATE LOCATION SHOWN. PIPE JOINTS NOT TO EXCEED 50 PERCENT OF THE MAXIMUM URFACE ELEVATION JOINT DEFLECTION SPECIFIED BY THE PIPE MANUFACTURER. ....... F�EXISTING .............................. 5. ABANDONED EXISTING WATER MAINS SHALL BE CAPPED WITH (MJ) CAPS. PORTIONS OF THE ABANDONED WATER MAIN MAY REQUIRE REMOVAL FOR THE CONSTRUCTION OF OTHER ROADWAY - - --- IMPROVEMENTS. 20 " " " " " " " " " " " " " " " " " " " " " " " " " " " " "" 6. EXISTING FIRE HYDRANTS SHALL BE REMOVED AND PROPERLY DISPOSED OF BY THE " " " "L0 RAINI 45' BEND R AVE S STA 3 +95.0 CONTRACTOR AFTER INSTALLATION, TESTING, AND APPROVAL OF THE NEW HYDRANTS. RAINIER AVE JuT 0 5 10 20 40 60 7. VERIFY LOCATION AND DEPTH OF EXISTING WATER MAINS AT ALL CONNECTION POINTS PRIOR ...................E 139'........... ............................... TO CONSTRUCTION. THE CONTRACTOR SHALL FIELD VERIFY THE OUTSIDE DIAMETER (O.D.) OF MNIER AVE S STA 34+07.1 ............................... RA1NIfRAVfSSTA34+ O6'. 4............................... 45' BEND HORIZONTAL SCALE IN FEET ALL EXISTING CAST —IRON AND ASBESTOS — CEMENT PIPES, AND PROVIDE THE PROPER E VERT. SCALE =1 2 HORZ. SCALE LONG —BODY ADAPTERS AND TRANSITION COUPLINGS FOR THE FINAL CONNECTIONS BY CITY NNECTION TO EAST SIDE OF RAINIER AVE S, SEE SHT 152 FORCES. CONNECTIONS TO ALL DUCTILE IRON PIPES SHALL BE MADE W1TH LONG SOLID SLEEVE RESTRAINED JOINTS 0 COUPLINGS (MJ). ................................................................................................................:................................................................................................................................. ............................... B. ALL CONNECTIONS TO EXISTING WATER LINES SHALL BE MADE ONLY AFTER ALL THE NEW WATER LINES AND APPURTENANCES HAVE SUCCESSFULLY PASSED ALL PRESSURE TESTS, S 4TH PLACE WATER MAIN CROSSING PROFILE - RAINIER AVE S STA 34 +10 CLEANED NTH POLY —PIGS, DISINFECTED H CHLORINE SOLUTION, AND HAVE SATISFACTORY BACTERIOLOGICAL LEST LAB REPORTS, AND ARE THOROUGHLY FLUSHED. B FLUSHED. 9. ELEVATIONS OF EXISTING CROSSING UTILITIES ARE PARTIALLY BASED ON RECORD DRAWING INFORMATION. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL UNDERGROUND EQUIPMENT PRIOR TO CONSTRUCTION AND INFORM THE ENGINEER IF CONFECT IS FOUND. 10. ALL WATER MAINS, FITTINGS AND APPURTENANCES SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAILS INCLUDED WITH PROJECT SPECIFICATIONS. 11. WATER PIPE AND FITTINGS INDICATED ON PLANS SHALL HAVE RESTRAINED JOINTS PER SPECIFICATIONS. SEE WATER PLANS, SHTS 132 -141 AND WATER PROFILES, SHTS 146 -159 FOR THESE LOCATIONS. 60 12. PROVIDE 10' HORIZONTAL SEPARATION FROM PARALLEL SEWER LINES. WATER SHALL CROSS ......... ......... ......... ......... ......... ......... ....... ......... ..... ......... ............. OVER EXISTING SEWER WITH 16" MINIMUM VERTICAL SEPARATION. WATER SHALL CROSS ALL OTHER UTILITIES NTH 12" MINIMUM VERTICAL SEPARATION. CONCRETE ENCASEMENT MAY BE EX. 6" CONC STORM DRAIN, IF LINK NECESSARY WHERE THESE REQUIREMENTS CANNOT BE MET. CORER. TO VERIFY LOCATION & DEPTH AINIER AVE S STA 41 +00.0 13. ALL WATER MAIN VERTICAL BENDS SHALL INCLUDE VERTICAL THRUST BLOCKING PER RENTON QROSS PLAN 330.3. ALL WATER MAIN HORIZONTAL BENDS SHALL INCLUDE HORIZONTAL THRUST CONNECTION TO WEST SIDE OF RAINIER AVE 5 v n' . ,a '. 11 BLOCKING PER RENTON PLAN 330.2. S 3RD PLACE WATER MAIN CROSSING PROFILE -RAINIER AVE S STA 41 +00 rtCwrzU UNARIIVUC I JLr i JIV i i SURVEYED. HPc DRAWN BY. SOD DESIGN BY so0 CHECK BY NJD PROJM D JF FILE LBSGWATPFW1.d�y KpG 79BWbaueN @SPdJNimmAwim RECORD Satlb,W1�NB TJAIq WA9BIfQ DRAWINGS MNIN V46774✓ID DRAWINGS �%+NN� All CITY OF RENTON "N P„eu�wo,ks DaPaamam APPROVED FOR CONSTRUCTION DY. DATE. RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST WATER PROFILE S 4TH PL AND S 3RD PL CROSSINGS CRAW FORD. 158 PROJECT NO TEDaoaao FEDAID IJD. -0M0 8) DATE MAR 2014 SHEET NO. ise of aoa NUMBER REVISION DESCRIPTION BY APP. DATE