RENTON 1963'
BE 162ND STREET
IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR
MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT
REQUIREMENTS OF WSDOT SECTION 2 -09.3(3)B, IT SHALL BE SHORED
AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE
FOR WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL
TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE
WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17
RCW. CHAPTER 49.17 RCW.
UTILITY NOTE
THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE
APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY
VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO
BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN
DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND
PRESERVE ANY AND ALL UNDERGROUND UTILITIES. AHBL ASSUMES
NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES.
AUTOCAD FILE
AN AUTOCAD DRAWING FILE IS AVAILABLE TO ASSIST WITH SITE
LAYOUT. PLEASE NOTE THAT ELECTRONIC FILES ARE PROVIDED FOR
CONTRACTOR'S CONVENIENCE AND SHALL NOT REPLACE NOR BE
USED TO SUBSTITUTE THE CONTRACT DOCUMENTS. THE
CONTRACTOR IS RESPONSIBLE FOR PROJECT LAYOUT ACCORDING
TO CONTRACT DOCUMENTS AND COST FOR ELECTRONIC AUTOCAD
FILES.
PHONE: (253) 383 -2422
FAX: (253) 383 -2572
FILL SPECIFICATION
DOUBLE
LASSROOM
1
raAHBLa
s
1
GRAPHIC SCALE
0 25 50 100 FEET
1' = 50 FEET
VERTICAL DATUM
NAVD 88
CITY OF RENTON VERTICAL BENCHMARK 1640
BRASS DISK AT INTX OF 116TH AVE SE AND SE 22ND ST
ELEV: 466.08
BASIS OF BEARING
NAD 83191
WASHINGTON STATE PLANE COORDINATE SYSTEM, NORTH ZONE
CITY OF RENTON HORIZONTAL CONTROL
HOLDING CITY MONUMENT NUMBERS 1640 AND 1863.
POINT NO. 1640
N= 170648.9763
E= 1305835..7479
BRASS DISK AT THE INTX OF 116TH AVE SE AND SE 22ND ST.
POINT NO. 1863
N= 167989.6214
E= 1305752.8478
BRASS PLUG AT THE INTX OF 116TH AVE SE AND BENSON RD.
A LINE BETWEEN THE TWO FOUND MONUMENTS BEARS
NORTH 01 °47'08' EAST.
SITE DATA
TOTAL LOT AREA = 648,172 SF (14.88 AC)
EXISTING IMPERVIOUS AREA = 212,164 (4.87 AC)
EXISTING LOT COVERAGE = 33%
NEW IMPERVIOUS SURFACES = 3,436 SF (0.08 AC)
REPLACED IMPERVIOUS SURFACES =19 SF (0.00 AC)
NEW PLUS REPLACED IMPERVIOUS SURFACES = 3,455 SF (0.08 AC)
NET CHANGE IN IMPERVIOUS AREA = 3,433 SF (0.08 AC)
UTILITIES / SERVICES
WATER: CITY OF RENTON
PHONE: 1- 425 -430 -7201
POWER: PUGET SOUND ENERGY
PHONE: 1-888 -321 -7779
GAS: PUGET SOUND ENERGY
PHONE: 1- 888 -321 -7779
PHONE: CENTURY LINK
PHONE: 1-800- 2441111
ONE CALL: 1-800 -0245555
FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY
STATE, FEDERAL, OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD.
CONSTRUCTION SEQUENCE
1. PRE - CONSTRUCTION MEETING.
2. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED NOTICE OF CONSTRUCTION SIGN).
3. FLAG OR FENCE CLEARING LIMITS.
4. INSTALL CATCH BASIN PROTECTION IF REQUIRED.
5. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S).
6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.).
7. CONSTRUCT SEDIMENT PONDS AND TRAPS.
8. GRADE AND STABILIZE CONSTRUCTION ROADS.
9. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT
DEVELOPMENT.
10. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND MANUFACTURER'S
RECOMMENDATIONS,
11. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE EROSION AND SEDIMENT CONTROL IS
ALWAYS IN ACCORDANCE WITH THE CITY'S EROSION AND SEDIMENT CONTROL STANDARDS.
12. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS DURING THE WET SEASON WITH STRAW,
WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, OR EQUIVALENT.
13. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS.
14. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS.
15. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BMPS REMOVED IF APPROPRIATE.
10
GENERAL NOTE:
1. CONSTRUCTION SURVEY SHALL BE PROVIDED BY THE CONTRACTOR.
TEMPORARY BENCHMARKS
TBM #1
AHBL #7
NAIL AND WASHER
N: 170444.8929
E: 1306185.8762
ELEV: 459.37
TBM #2
AHBL#8
SCRIBED X
N: 170451.6706
E: 1306064.9195
ELEV: 459.71
LEGEND
EXISTING
B1.0
PROPOSED
A NAIL AND WASHER
CIA
a CLEANOUT
D STORM CATCH BASIN
NOTES AND DETAILS
FIRE HYDRANT
C
LY IRRIGATION CONTROL VALVE
R. ELANGOVAN
NWATERVALVE
n
0rnr
n0
P =PINE
y --- D -- STORM LINE D -
1 - WATER LINE
C
p- ELECTRICAL LINE
rrca¢awW. FlERSi
FENCE
REVISION BY
ROOF DRAIN LINE RD
L YARD DRAIN
M
I-1 JUNCTION BOX
POWERVAULT
GUY WIRE
POWER POLE
T COMMUNICATION VAULT
L`V - CONTOUR LINE ELEV -
XXX.XX SPOT ELEVATION FG: XXX.XX
VICINITY MAP
OWNER
RENTON SCHOOL DISTRICT
7812 S 124TH ST
SEATTLE, WA 98178
PH: (425) 2044403
CONTACT: RICK STRACKE
ARCHITECT
GREENE- GASAWAY ARCHITECTS
P.O. BOX 4158
RENTON, WA. 98063
PH: (253) 941 -4937
FAX: (253) 941 -5122
CONTACT: CALVIN GASAWAY
U14004147
R=374502
Checked for Compliance to City Standards
Z/2*
PERMIT SET
B1.0 TOPOGRAPHIC SURVEY
C1.0 COVER SHEET
CIA TESC AND DEMOLITION PLAN
C1.2
wrxrtu xnt
AS NOTED m°'°'="'°'°"'°i'°°'
DATUM
li CITY OF
t RENTON
Planning/Building/Public Works Dept.
NOTES AND DETAILS
C
9
3E
R. ELANGOVAN
N
n
0rnr
n0
z
F. KATONA
I I
1 CITY OF RENTON COMMENTS
C
7 23 14
G
rrca¢awW. FlERSi I - xor f°1 yNO. REVISION BY DATE APPR N+1umS. COMFORT
1M
CIVIL ENGINEER
AHBL, INC.
2215 NORTH 30TH STREET
SUITE 300
TACOMA, WA 98403
PH. (253) 383-2422
FAX (253) 383 -2572
CONTACT: BILL FIERST, P.E. OR ROHIN
ELANGOVAN, E.I.T
SURVEYOR
AHBL, INC.
2215 NORTH 30TH STREET
SUITE 300
TACOMA, WA 98403
PH. (253) 383-2422
FAX (253) 383 -2572
CONTACT: DAVID FOLLANSBEE, P.L.S.
SHEETINDEX
B1.0 TOPOGRAPHIC SURVEY
C1.0 COVER SHEET
CIA TESC AND DEMOLITION PLAN
C1.2 CIVIL SITE AND DRAINAGE PLAN
C1.3 NOTES AND DETAILS
C1.4 NOTES AND DETAILS
e
9010 ED = ZONAL 1,.,p
n
Nona T A C O M A - SEATTLE • SPOKANE • TRI- CITIES
Ncwr•i a m ox•R swi •wa¢ u
b®4LL YIL .Vrt mV.M N91Gp 6
m'r '` •r "" ad a3r,•e 2215 North 30th Street, Suite 300 Tacoma, WA 9840owavinsxrtmomnrtaaois
O1W , ro am m *" Bw 253.3832422 TEL 253.383.2572 Flue wwwahN.ean wEB
mmi ro our rosr w ra xrcoxs wo¢r.
CASCADE ELEMENTARY SCHOOL JULY 2014
PORTABLES
RENTON SCHOOL DISTRICT ••
COVER SHEET '.
m: 1 W. 5
CP, 12 -'- Y"? mail
n
x
3
8
HT
O
n
l J
c
C
9
3E
CDC
N
n
0rnr
n0
n
N7
3
8
HT
O
n
l J
c
C
9
3E
CDC
N
n 0rnr
n0
z Z
x C
G
wz M
m M
Ns,
n
N7
8
HTmlJ
g -z
C
9
3E
N
n 0rnr
n0
I A
G
8
o
O
M
D
D yV,1 C
9
3E