Loading...
HomeMy WebLinkAboutS-0701076701110 _ ,ME N O 1�S i i CoA/srRUCrioA/ 1. D UR ING CO, N STR UCTION SEWAGE FLOW FROM . EAS',c -meA1 r 90" 0 .ecP SEWIFR a EXISTING 8" 0 AND 24" SEWERS TO BE I N TER - ro eEA17'0M 56WAGE h ` CEPTED SHALL BE MAINTAINED TO EXISTING 90" Tk'EATMEAIT PLANT INTERCEPTOR. DIVERSION OF SEWAGE THROUGH NEW 90" SEWER PIPE SHALL BE MADE AFTER /2" `YA7ee \� ACCEPTANCE OF WORK FROM JUNCTION STRUC- .SLIPPLY TO REM TOM TURE NORTH TO EXISTING MANHOLE SEwwGE recw"EMT `\ PLANT J� 2. REMOVE W I THOUt DAMAGE THE 12" GATE VALVE % EX /ST /A/G FOR COA/NECT /ON \ MANHO1_E /wV943t AND THE WATER LINE FROM THE TEE TO THE NORTH J THRUST BLOCK IAPPROX. 130 LF). PLUG TEE SEE SPECS, BRANCH AS REQUIRED. TRANSPORT AND STORE TN2u5T 5z-oek \ � � � EX/5 eNEAD THE SALVAGED PIPE AND VALVE AS DIRECTED. I SEE NOTE 9 � e_ /lot THE PIPE NORTH OF EXISTING BULKHEAD MAY BE SEE NOTE 2 � � \\ � ; I 3. DEW4 8/7 _ _ ,S7,4 0 ,106, ♦o FULL, DEPENDING ON DOWNSTREAM CONDITIONS. CHECK WITH THE SUPERINTENDENT OF THERENTON- /VEIN' LOC4T 10N OF /2"0 I SEWAGE TREATMENT PLANT. CAST IRCIV w.4TE1P P /PE \\ 9011 SEE TYP. TREIV CA/ RC P SL= =CT /oN DWCr. 7 I) 50• — — O 6ENE,PAL NOTES: � „E,�' /STING /5 4 O I 40RIO2 TO C0AA67R4(CT 10A1 C0"7"R,ACTOR I I C,MP, 70 gE \1 SHALL vER/FY THE L OCAT/OAl AND I A8AAW0A/ED 1c0Ati57-A0`1.1Cr1OA1 h:4.ev4T /ON OF ALL EX /STING UT /L /T /ES 17� I SEE NOTE / EASEMENT TO Be RE-Z OCA7`II OR I !N rERCEP TED. p 2. THE COA/reACTOR SHALL COAITACr THE ' PROPER 41;r/I' AGEA/C Y 1O DAYS PRIOR TO RELOCATION OF UT/L /T Y POLES AA/D 14 G41Y AMCf,/I rHAr 4,eE- /A/ COA/FLICr NN I I \ W /TN TNF_ NOS ,< 3. FOR ;rREMCH SEC710AIS SEE OF DRAW /A/G 9 I I \ \ C2EE K R/P,iE it 0A1 PERMAN� � O (I E45El�1ENT O I I �EL OCATE EX 1.6TING I I I2" 0 CAST /,eON MATER ,PIPE SEE SPECS. 41-SO ; I I SEE NOTE 2 J!I�GT /OA/ 5'TPUGTU�PE \ , SEE DWG. f, I I 4 E.Y /STING S'TA. 0,169.7 e4'O CLASS\ 24 SAAB SET Rlnrne r0 I I Q .PCP SEINER I E,Y/ST/N6 d" SWA .. IM re eCERT B" S. ' I L, -- - = 23 =9 f ANEW M, N. 018-114 TEL. cavoLlir 6 VE/IriGAL TH2[J5T 5LOCZ 4-711--: N ME'ASU�p /A/G M. y OL/CT .� %"A.C, SEE DET. C17. COA/r,2A0ro,Q INK EL, 101,4z UP RCP SEE NOTE / 59 4 L L AD.IUST T4 CL EAQ � h DErA /c Al 7 Ex/srlNG u r /�/ r/FS o�cyi _ _ . .. - . • .. I .6rA, /, 00. 00 Al 173,166. 33 I 0Cr 16:54,125.15 f3�P /D6E _ ` FOB CONNC-CT/oN I To EX/S•T 1Z "W4r5e 8TH y�sTuf3 MA /N L 3 t SEC � EPCC 11S - , . ... . ......:..:.. .•. • -EX /ST le-0 W4 r4P LINE • SEE A/OTE ? — — — 7Z" 0 eCP -l" GA S KW.. r) Y - Afrl5T /P" GATE YAL VE SEE NOTE 2 T � UP REA L A;A/MENr A5 PER SUP pl�t/G. 2 • VP PLAN SCALE : I" = 10� 0 SMOOTH "0,,4 TAKE' %QAMSIT /OA/ L z r rl-I 7 _ Nt N ti 0 SL /P - DA/ P. V C. COL/PL /A/G .1 �l II II I II 1 I II SLOPE INN- _ j i I ' SEE NOTE 3 1 I I _j 7 PLAN ^,^AIr mi.0iY In Qo� ~ hW STD. MAMAIOL E BASE SKr /ON SHE F FLOW I _ I I SLOPE SEE A/OTE 4 CHANNEL v HALF P /PE SE�CT/OM OR FO*eMED SURFACE I SECTION 7 /-0 STD. P. V C. FLECrRICAL COA10411 r WITH SLIP-ON FIrrIM S A 7 -a-ulm Fl�l " T-I CRAM,, /NV SECTION () 7 I MEASURING MANHOLE DETAIL 7 gE'Q� %V NO SCALE HORIZONTAL BEND - 221/2 TO 450 Z MAN. o . 3000 Ps/ 7YP A LL Th',ZU5r f3L.I 7'x 5 CONC. 13L OG 4 45 *PENT TYP. SEWER `- MORTAR F /LL 2 SECTION 7 NOTES: (P ER TA I N I N G TO MEA SUR I NG M. H. ONLY) 1. USE AN EPDXY BONDING COMPOUND WHEN PLACING THROAT SECTION AND TRANSITION AGAI NST HALF P I PE SECTI ON OR CHANNEL. 2. THE THROAT SECTION WILL BE FABRICATED FROM 3/ 8 INCH GALVANIZED STEEL PLATE MORTARED AND KEYED I N PLACE. 3. MAINTAIN SEWER SLOPE AT LEAST 10D UPSTREAM FROM FLUME- BENDS OR CONNECTIONS SHALL NOT BE ALLRED IN THI S 10D REACH. 4. DOWNSTREAM SLOPE OF SEWER SHALL BE EQUAL TO OR GREATER THAN UPSTREAM SLOPE. 5. THE THROAT CROSS- SECTION MUST BE UNIFORM THE ENTIRE LENGTH. 7 =0 ¢{ EL . 113 ¢` 'I //D t TYP . 4 i/ of VERTICAL THRUST BLOCK - DETAIL 7 NO SCALE 5A,f lG I= /L L To 6,F Z0,40 CE57094r 10N CoMPACTEO /N C01VT4C7- SEE T'YP. SEC774A/S DWG. 9 Wiry 411v015T41Q8ED I TRC-NC H WALL - -� SECTION 7 THRUST BLOCK - DETAIL e NO SCALE 7 1Q9533 MUNICIPALITY 0 M E T R O P 0_L TAN S E T T L E suds couc-Nr g.4aeF /ci. 511.)C- SLOPE TO ,�? ► METROPOLITAN ENGINEERS a 5#A1_1. 13E CL ASS Zr OA10FR 15E DETEEM/IVGA Ali -`_ 4� p /�gVCO A2EgS CL455 i3Y CO/V iQACT'O,Q DESIGNED 41NDC-9 UNIEO AkEAS . SPIT /NfsL 1AI 0 09 ~ PGAcE CONcQE'7E ,46g1�t/ST �o � 7-YPc F M,4 rE2 /q L UNI0 /STU1 -?6eD G/IoUN/.� ,.o � • APPROVED Me 0 DATE -MAY 1967 o �/DF r -1 eus r �L oc& Pe HILL AND INGMAN R W BECK AND ASSOCIATES Design Engineer - Metropolitan Engineers AS CON STRUCTE D AT E I/F2Y L'yANI QF r hton En ine rs F fN pp 9 For Municipality of Metro oliton ;Bottle p v C DATE /�� c:. / 9� L� �� F. SECTION 7 THRUST BLOCK - DETAIL e NO SCALE 7 1Q9533 of w4sy2c 0 H O T . Z TYPICAL TRENCH SECTION Ct 3 FOR WATER PIPE oFs�c � /STFYL- � NO SCALE s /oNQL E�� SOUTH INTERCEPTOR SECTION I DRAWING NUMBER DETAIL PLAN—MEASURING MANHOLE SHEET NUMBER AND DETAILS 7-OF 9 -_ MUNICIPALITY 0 M E T R O P 0_L TAN S E T T L E F,EE R 218 A R ENTON LM METROPOLITAN ENGINEERS DESIGNED ' 0 09 DRAWN 111CC0OS BROWN AND CALDWELL CAREY AND KRAMER SUBMITTED —:_ RECOMMENDED APPROVE APPROVED' � • APPROVED SCALE A S SHOWN DATE -MAY 1967 SYSTEM CHECKED �PFW HILL AND INGMAN R W BECK AND ASSOCIATES Design Engineer - Metropolitan Engineers Project Engineer - Metropolitan Engineers Chief Engin er - Metropolitan Engineers r hton En ine rs F fN pp 9 For Municipality of Metro oliton ;Bottle p v C of w4sy2c 0 H O T . Z TYPICAL TRENCH SECTION Ct 3 FOR WATER PIPE oFs�c � /STFYL- � NO SCALE s /oNQL E�� SOUTH INTERCEPTOR SECTION I DRAWING NUMBER DETAIL PLAN—MEASURING MANHOLE SHEET NUMBER AND DETAILS 7-OF 9 -_