UUKHUKA I IUN J I Ur
o
MUELLER B -20013 (IPT)
m
OR FORD F6500
s�
J
2" HMA PAVING
6„ BO
C °rAPPcT f
G V 10'
'�k �� r, �
WATER SERVICE
10 � o
ROMAC 101 -S POLYETHYLENE PLASTIC
r NOT TO EXCEED 6"
STAINLESS STEEL PIPE WITH FORD NO. 72
z
1 1 3
`
Q0
�
2" CUBE
STRAP SADDLE STIFFENER INSERTED IN
(IPT) OR EQUAL �T-� END OF PIPE
O
a
Xz
O
J"\.
4 >> 4 >, 471 cam,
1 /3 L
COMPRESSION PACK JOINT,
FORD C16 PACK
V)
3. 3� \�
-44 (IPT)
MINIMUM MINIMUM
EXIST. A/C EXIST. A/C
6" 6„
SOIL PIPE
(LENGTH AS REQUIRED)
JOINT COUPLING H 15 54 200
WATERMAIN WATERMAIN
FRONT SIDE FRONT
CLASS 52
4
VALVE MARKER POST BLOW -OFF ASSEMBLY
L
r DUCTILE IRON
Q
o
WATER MAIN
SANITARY SEWER �\
OR OTHER UTILITY , O
VALVE MARKER POST WILL BE MARKER POST
00
\\
REQUIRED UNLESS VALVE IS IN _ AUNLESSOBLOW -OFF
PAVEMENT AND TOP OF VALVE
PLAN
\%
BE REQUIRED
BOX IS AT FINISHED GRADE.
O
z
IS IN PAVEMENT.
4 1/4" DIA. X
1/8" MIN. THICKNESS
CORPORATION STOP COMPRESSION
PACK JOINT
COUPLING
NOTES:
z 1' 1' CLEAR EDGE OF PAVEMENT
-
lO COUPLING: ASBESTOS CEMENT (A /C) BY DUCTILE IRON
2" HMA PAVING
a �,
a
1" METAL STOCK
LENGTH AS REQUIRED
( )
WA TER SER�CE
(DUCTILE IRON ROMAC STYLE 501 OR EQUAL).
'
MATCH EXISTING GRADE::::
2 DUCTILE IRON PIPE, CL. 52, DIAMETER TO MATCH EXISTING A/C.
O I I 1 CLEAR
o
O3 BACKFILL EXISTING A/C AND COUPLING WITH PEA GRAVEL TO 1 ABOVE PIPE.
4O BACKFILL UNDER THE WATERLINE WITH CRUSHED ROCK COMPACTED TO 95%
10 °t STIFFENER INSERT
MDD, OR CONTROLLED DENSITY FILL (CDF) PER GOVERNING ROAD AGENCY
REQUIREMENTS.
_ _ _ _ _ - --�- -- - ( 18 " -24" CAST IRON
PROTECTIVE PAD � VALVE BOX W/ LID
MARKED "WATER"
I
Lij
-
ROMAC 101 S
1�DT*
O5 BACKFILL OVER THE TOP OF THE WATERLINE NTH CRUSHED ROCK COMPACTED
SERIES 9408 OR AS
I - APPROVED BY DISTRICT
STAINLESS STEEL
G�
�j �� 'l,f
TO 959 MDD, OR CONTROLLED DENSITY FILL (CDF) PER GOVERNING ROAD
AGENCY REQUIREMENTS. BACKFILL OVER THE TOP OF THE WATERLINE WITH
ATERMAIN I I
2 1/4" CUBE (INSIDE MEASUREMENTS)'
1 "
� WATER MAIN STRAP SADDLE
(IPT) OR EQUAL
G�CO
��� .�0�
NATIVE MATERIAL COMPACTED TO 9090 MDD IF LOCATED WITHIN EASEMENT OR
/ 8 MINIMUM THICKNESS
r� �edwoo
� o w
a,
UNIMPROVED AREAS.
Q
ELEVATION
� c a
o
60 A/C DISPOSAL PER CURRENT WAC AND PUGET SOUND AIR POLLUTION
CONTROL AGENCY REQUIREMENTS.
US
PROTECTIVE PAD WATERMAIN
NOTES:
Cb�S
Q,O
j
PLAN SECTION
LENGTH AS REQUIRED TO PUT OPERATING NUT TWO (2) FEET FROM SURFACE.
NOTES:
O4w
EXTENSIONS ARE REQUIRED WHEN THE VALVE NUT IS MORE THAN FOUR (4)
1. SERVICE LINE FITTINGS: ALL FITTINGS SHALL BE CAST FROM WATER WORKS BRASS
FEET BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF TWO (2)
CONFORMING TO C800.
VALVE BOX PROTECTIVE PAD
FEET LONG. ONE EXTENSION IS TO BE USED PER VALVE.
2. MUNICIPAL SERVICE PIPE: IRON PIPE SIZE ID, ASTM D -2239, SIDR 7, PE 3408
NOTE:
ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED AS NOTED, AND PAINTED
(HI -MOL PLASTIC) WITH 16 GAUGE TRACER WIRE.
v
Q
MARKER POST SHALL BE PAINTED WITH 2 COATS OF WHITE PAINT,
LETTERS SHALL BE 2" HIGH AND STENCILED IN BLACK PAINT. MARKER
WITH TWO (2) COATS OF METAL PAINT.
r
2
�
N
MID
POST SHALL BE LOCATED 10 FT. (MIN.) AWAY FROM EDGE OF ROAD WAY.
..
`
w
88
rwo**� 1 " WATER SERVICE CONNECTION
e
-�
Nv-
A/C WATER MAIN REPLACEMENT
VALVE BOX PROTECTION
w VALVE OPERATING NUT EXTENSION
I J
8
8
14 NTS
15 NTS
- Q. �
W
o
w SANITARY SEWER CROSSING
rw*`� P AD AND MARKER POST
zo
z
Q
�
z
Q.2 NTS
Q.3 NTS
Wa
oQ
aQ
o
o
u
0
0
U
METER
00
pi u
Q +
Y
m
o
EXISTING
� 3
u z a
\\
NEW 1" HI -MOL PLASTIC
PIPE, CL. 200
TO WATER MAIN I
__________ __ _ _____ TO HOUSE
c C:- 3
1 g �Z5
m 00
IwIt
a �
t
oo
\ \.
- - - - - - - - - - --
:EXISTING
Ln
N
m
6" TO TOP OF .
,
ANGLE
L- - - - - -J
EXISTING SERVICE, PIPE TO BE SERVICE
Z nt
STOP
" "
1 MIN. - 2 MAX. FROM INSIDE 3/4 & 1 SERVICES
FRONT WALL OF METER BOX (TYPICAL)
REMOVED (MIN. 2 OUTSIDE
NEW METER BOX) AFTER
TRANSFER OF SERVICE
3�5
o
� p
w O V
o z a
(TYPICAL FOR ALL SERVICES)
T-4 Q
PROVIDE NEW METER BOX (SEE NOTE 2)
COMPRESSION PACK JOINT
PLAN VIEW
ADAPTER, MUST BE CAPABLE OF
Z
RECEIVING 3/4" OR 1" ANGLE
FOR STANDARD 5/8 "x3/4" METER,
INITH NO ADDITIONAL
W H
FITTINGS USE 3/4" ANGLE STOP W /LOCK
WING, FORD NO. KV63 -342W OR
/ '7/77
1" HI -MOL PLASTIC PIPE, CL 200 MUELLER H -14259 SERIES.
FOR 1" METER, USE 1" ANGLE STOP
W /LOCK WING, FORD N0.
KV63 -442W OR MUELLER H -14259
6" TO TOP OF
1" MIN. - 2" MAX. FROM INSIDE ANGLE STOP
FRONT WALL OF METER BOX
MID - STATES PLASTIC HDPE METER BOX N0. BC111812BXL
~_
V
SERIES.
3/4" & 1" SERVICES
TYPICAL FOR ALL SERVICES �'
( ) ( (TYPICAL)
SINGLE SERVICE
�
COMPRESSION PACK JOINT
ADAPTER, MUST BE CAPABLE OF
Ui
U)
RECEIVING 3/4" OR 1" ANGLE
Q
STOP WITH NO ADDITIONAL I
"x3/4"
FITTINGS I FOR STANDARD 5/8 METER,
Z Q
USE 3/4" ANGLE STOP W /LOCK
W Ch
w W �-
1" HI -MOL PLASTIC PIPE, CL. 200 WING, FORD NO. KV63 -342W OR
MUELLER H -14259 SERIES.
O
W
NOTES
EXISTING SERVICE & FITTINGS FOR 1" METER, USE 1" ANGLE STOP
w N
w
W /LOCK WING, FORD NO.
Q
'op
V
1. DO NOT BACKFILL UNTIL ALL BRASS FITTINGS HAVE BEEN INSPECTED BY THE
DISTRICT.
KV63 -442W OR MUELLER H -14259
SERIES.
<0>
O
J w
Z 0
>
2. WATER METER BOXES SHALL BE A MINIMUM OF 5 FEET FROM POWER VAULTS,
SINGLE SERVICE
Q Z
W a. Q
HANDHOLES, STREET LIGHTS AND ELECTRICAL SERVICES AND SHALL BE A MINIMUM OF
0 w 300
3 FEET FROM OTHER WATER METERS, SERVICES, FIRE HYDRANTS AND BLOWOFF
NOTES
� V
Q
ASSEMBLIES.
1. BRING NEW WATER SERVICE INTO METER BOX AND INSTALL NEW ANGLE STOP, ETC. TO MATCH
VERTICAL AND HORIZONTAL ALIGNMENT WITH EXISTING FITTINGS FOR METER RECONNECTION.
"WATER"
0
W cl
3. METER BOX SHALL BE SUPPLIED BY DEVELOPER OR CONTRACTOR AND SHALL BE PER
CARSON LID #11184135 MARKED
cry a.
STANDARD DETAILS W -17 AND W -18.
2. DO NOT BACKFILL UNTIL BRASS FITTINGS HAVE INSPECTED Y THE
L LLB S GS E BEEN B E
Z
O
3. WATER METER BOXES SHALL BE A MINIMUM OF 5 FEET FROM POWER VAULTS, HANDHOLES,
Y
W O
U
V Z
STREET LIGHTS AND ELECTRICAL SERVICES AND SHALL BE A MINIMUM OF 3 FEET FROM OTHER
w V
Q Q
WATER METERS, SERVICES, FIRE HYDRANTS AND BLOWOFF ASSEMBLIES.
4. METER BOX SHALL BE SUPPLIED BY DEVELOPER OR CONTRACTOR AND SHALL BE PER
V
U)
STANDARD DETAILS W -17 AND W -18.
(n
HDPE METER BOX NO. BC111812BXL
O
INSTALLATION DETAIL FOR NEW
O
rw"* TYPICAL SERVICE DETAIL,
S ERVICE TRANSFER TO EXISTING METER
F OR 5/8 "x 3/4" METER
�'
16 NTS