Loading...
HomeMy WebLinkAboutW-3610020 co M n N Gt. SCOPE THE NOTES ON THIS SHEET AND THE STANDARD STRUCTURAL DETAILS ARE GENERAL AND APPLY TO THE ENTIRE PROJECT WHETHER SPECIFICALLY CALLED OUT OR NOT, EXCEPT WHERE THERE ME SPECIFIC INDICATIONS TO THE CONTRARY ON STRUCTURAL SHEETS. IF THERE ARE QUESTIONS, THEY SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER AND ANSWERED IN WRING PRIOR TO CONSTRUCTION. G2. APPLICABLE SPECIFICATIONS ANO CODES A. IBC 2012 WITH APPUCABLE EDITIONS OF THE CODE REFERENCED STANDARDS. B. LOCAL JURISDICTION AMENDMENTS G3. DESIGN CRITERIA 1. APPLIES TO ALL STRUCTURES (UNO) A. DEAD LOAD: 1. ACRAL TRIBUTARY STRUCTURE WEIGHT 2. SUPERIMPOSED DEAD LOAD: B. LVE LOAD: 1. MINIMUM REQUIREMENT FOR FALL ARREST SYSTEM: 5,000 LB 2. HATCH LIFT LOAD FOR GREENSAND: 1000 LB C. SEISMIC: 1. ABOVE GRADE, NON WATER BEARING STRUCTURES: a. OCCUPANCY CATEGORY. V (PER EXISTING DRAWING) b. IMPORTANCE FACTOR: 1.5 C. SPECTRAL RESPONSE ACCELERATION, SS = 1.3799 d. SPECTRAL RESPONSE ACCELERATION. S1 = 0.4709 SITE CLASS: C (PER EXISTING DRAWING) f. SEISMIC DESIGN CATEGORY: g. SPECTRAL RESPONSE COEFFICIENT, SDS = 0.919g h. SPECTRAL RESPONSE COEFFICIENT, SDI — 0.417g I. BASIC SEISMIC FORCE RESISTING SYSTEM: j. SEISMIC RESPONSE COEFFICIENT. = 0.57 G4. ;;AF SAFETY AND STRUCTURE STABIUTY DURING CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. STRUCTURES HAVE BEEN DESIGNED TO RESIST THE DESIGN LIVE LOADS ONLY AS A COMPLETED STRUCTURE. G5. OPENINGS OPENINGS FOR PIPES, DUCTS, CONDUITS, ETC. ARE NOT ALL SHOWN ON THE STRUCTURAL DRAWINGS. COORDINATE AND PROVIDE OPENINGS AS REQUIRED TO ACCOMMODATE ALL WORK SHOWN OR SPECIFIED IN THE CONTRACT DOCUMENTS AND OTHERWISE REQUIRED FOR THE FURNISHING OF A FUNCTIONALLY COMPLETE PROJECT. REINFORCE AROUND OPENINGS PER STANDARD STRUCTURAL DUALS UNLESS OTHERWISE SHOWN. 06. SPECIAL INSPECTIONS SPECIAL INSPECTIONS ME REQUIRED IN ACCORDANCE WITH CHAPTER 1 AND CHANTER 17 OF THE IBC. PAYMENT FOR THESE INSPECTIONS IS NOT THE RESPONSIBILTIY OF THE CONTRACTOR. THE CONTRACTOR SHALL PROVIDE FOR FULL ACCESS TO THE WORK BY THE SPECIAL INSPECTOR AND SHALL PROVIDE FOR THESE INSPECTIONS IN HIS CONSTRUCTION SCHEDULE IN ACCORDANCE WITH THE SPECIFICATIONS. G]. STANDARD DUALS THE STANDARD DUALS DEPICT TYPICAL DETAILING TO BE USED ON THIS PROJECT. IF CONDITIONS ME NOT EXPLICITLY SHOWN ON THE DRAWINGS THEY SHAT BE MADE SIMILAR TO THE STANDARD DETAILS. OBTAN APPROVAL OF ENGINEER IN WRITING FOR SIMILAR CONDITIONS PRIOR TO CONSTRUCTION. GB. THE CONTACTOR SHAT FIELD VERIFY AL DIMENSIONS AND ELEVATIONS OF EXISTING CONSTRUCTION AS REQUIRED TO COORDINATE NEW CONSTRUCTION. SUBMIT REQUIRED CHANGES FOR APPROVAL. G9. CONTRACTOR TO SUBMIT FOR REVIEW ALL EQUIPMENT SIZES, OPERATING WEIGHTS, VIBRATION FORCES. SUPPORT LOCATIONS. ALONG WITH ANY FLOOR OPENINGS. NOTCHES. AND RECESSES REQUIRED BY SUCH EQUIPMENT. CONCRETE SUPPORT PADS AND/OR FRAMING REQUIRED TO SUPPORT SAID EQUIPMENT SHAT NOT BE FABRICATED AND PLACED UNTIL THE CONCRETE SUPPORT PADS AND/OR FRAMING IS APPROVED TO SUPPORT THE EQUIPMENT. S1. DESIGN STRENGTHS: WIDE FLANGE AND TEES: Fy=50 KSI PIPES: Fy=35 KSI STAINLESS STEEL Fy=33 KSI HSS SECTIONS Fy=46 KSI ALL OTHER PLATES AND SHARES: Fy=36 KSI S2. DIMENSIONS: TO CENTERLINES OF COLUMNS AND BEAMS, TOP SURFACES OF BEAMS AND TUBES AND HACKS OF CHANNELS AND ANGLES UNO. S3. ELEVATIONS: TOP OF STEEL REFERS TO TOP SURFACE OF MEMBER OR FLANGE UNO. S4. WHEN FILLET WELD SIZE IS NOT INDICATED, PROVIDE MAXIMUM WELD SIZE BASED ON MATERIAL THICKNESS IN ACCORDANCE WITH AISC SPECIFICATIONS. S5. ALL BOLTED STRUCTURAL CONNECTIONS ARE BEARING TYPE CONNECTIONS UNLESS OTHERWISE SPECIFIED TO BE SLIP—CRITICAL. PROMDE LOAD INDICATING WASHERS AT SUP—CRITICAL CONNECTIONS. S6. CONFORM TO AISC 360, STEEL CONSTRUCTION MANUAL AND AISC 341. SEISMIC DESIGN MANUAL. S]. THE SEISMIC LOAD RESISTING SYSTEM (SLRS) IS DENOTED ON THE FRAMING PLANS AND FRAME ELEVATIONS. THE SLRS DESIGNATION INCLUDES THE MEMBER AND CONNECTIONS AT EACH END. FRAMES ARE DENOTED AS FOLLOWS: A MOMENT FRAME: (SLRS) B. CONCENTRICALLY BRACED FRAME: (SLRS) FOR SLRS SYSTEMS OR PARTS OF SYSTEMS THAT ARE NOT INCLUDED IN FRAMES, (SLRS) IS PLACED NEXT TO THE BEAM SIZE ON THE FRAMING PLAN (eg: ON A COLLECTOR ELEMENT (DRAG STRUT):MEMBER DESIGNATION (SLRS) SB. ALL STEEL BEAMS SHALL RECEIVE STANDARD CAMBER PER THE SPECIFICATIONS UNLESS NOTED OTHERWISE ON THE PLANS. BEAMS REQUIRING SPECIAL CAMBER ME DENOTED ON THE BEAMS SHOWN ON THE FRAMING PLANS. EXAMPLE: (+1/27 INDICATES X". NO. I REVISION I BY I DATE I APPR AS NOTED '"'�•� rwmm VL DATUM CITY OF RENTON Planning/Building/Public Warks Dept. RECORD DRAWING THIS RECORD DRAWING WAS PREPARED USING INFORMATION PROVIDED BY OTHERS TO HDR AND OONTANS ONLY THE LEVEL OF DETAIL AS PROVIDED. THE INFORMATION WAS NOT INDEPENDENTLY FIELD VERIFIED OR CONFIRMED AS BEING ACCURATE BY THE ENGINEER. NEITHER HDR NOR THE CITY OF RENTON WARRANT OR GUARANTEE THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. MAPLEWOOD WATER TREATMENT PLANT ACCESS PLATFORM & FALL PROTECTION IMPROVEMENTS GENERAL STRUCTURAL NOTES