HomeMy WebLinkAboutS-383501SE 1/4 SECTION 3,
MAE
NEW B" if IN 450.40 (W)
IE OUT 455.36
Call 2 Working Days Before You Dig
811
Utilities Underground Location Center
(ID,MT,ND,OR,WA)
HOLDINGS LLC
r 0 --
[[FF LF::-: -�� UIED
1
D.R. STRONG
CONSUL TING ENGINEERS
ENGINEERS PLANNERS SURVEYORS
620 - 7TH AVENUE, KIRKLAND, WA 98033 N O .
0 425.827.3063 F 425.827.2423
REVISION
TOWNSHIP 23 N. RANGE 5 E
* W.M.
R TINS RANCH
SEWER STUBS
LOT
*STA TION
FG
IE AT MAIN
LENGTH
END 1E
SLOPE (9)
1
0+30
471.2
457.61
44
464.20
15.00
2
1+13
473 4
460.21
43
468.63
19.58
3
1+66
476.0
461.87
42
471.43
22.77
4
0+52
476.0
463.81
41
471.70
19.24
5
2+58
475.8
467.20
74
470.30
4.19
6
2+26
475.7
466.88
86
470.20
3.86
7
1+41
475.5
466.06
34
470.42
12.82
8
0+57
475.4
465.17
34
470.46
15.55
9
1+02
475.5
464.36
36
470.71
17.63
10
0+42
475.8
463.68
36
470.63
19.29
11
1+70
475.3
462.01
35
471.46
27.00
12
1+17
472.5
460.32
34
468.70
24.64
13
0+32
469.5
1 457.67
33
1 465.32
1 23.19
NO TES:
1. STATION IS TO NEAREST DOWNSTREAM MANHOLE
2. END IE IS AT STUB END
J. CONTRACTOR TO VERIFY ELEVATION OF EXISTING HOME'S SEWER PRIOR TO
CONNECTION.
UTILITY CONFLICT NOTE:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL
EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND
SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE
CALLING UTILITY LOCA TE A T 811 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES A T LOCA TIONS OF
NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCA TIONS OF SAID
UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE
SUBJECT TO VARIA TION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSUL T D. R. STRONG
CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING W1 TH CONSTRUCTION.
NO TES.-
1.
ES:1. ALL TRENCH RES TORA TION SHALL BE PER THE CURRENT CITY OF RENTON TRENCH RESTORATION AND
STREET OVERLAY DETAIL. PER SECTION 7 REQUIREMENT FOR PATCHING, OVERLAY, OVERLAY KID THS,
TRENCHES (ROAD CROSSINGS). IF THE OUTSIDE OF THE TRENCHING IS Wl THIN THREE FEET (3) OF
ANY ADJACENT LANE LINE, THE ENTIRE ADJACENT TRAVELED LANE AFFECTED WILL BE REPAVED.
2. REFER TO C20 FOR UTILITY CROSSINGS.
J. MINIMUM SIDE SEWER SLOPE IS 2.009:
4. MINIMUM SIDE SEWER DEPTH IS 5 -FEET FROM FINISHED FLOOR ELEVATION.
5. ALL SSMH WILL BE A MINIMUM OF 48 -INCH DIAMETER.
6. ALL SIDE SEWER TO BE INSTALLED AT A MINIMUM OF 8 FEET INTO THE LOTS
DAYLIGHT BASEMENT LOTS NOTE.-
LOTS
E:L0TS 11-13 TO UTILIZE PRI VA TE EJECTION PUMP FOR LOWER FLOOR. THE SEWER WILL BE PUMPED TO
THE UPPER FLOOR AND THEN GRA VI TY DRAIN TO SEWER MAIN.
HORIZON TA DA TUM.-
NAD
UM:NAD 1983/91 PER CITY OF RENTON MONUMENTS.
VIER TI CAL DA TUM:
NA VD 88, PER CITY OF RENTON VER TI CAL CONTROL.
BENCHMARK.-
1.
ENCHMARK:1. CITY OF RENTON CONTROL POINT NO. 1845. SE, CORNER SEC. 3-23-5. FOUND CONCRETE MONUMENT
WITH PUNCHED BRASS PLUG, DOWN 1.7; IN MONUMENT CASE. ELEVATION = 467.76 FEET.
2. CITY OF RENTON CONTROL POINT NO. 2097 NEE, CORNER SEC. 3-23-5. FOUND STONE MONUMENT
WITH FAINT X, DOWN 1.7; IN MONUMENT CASE. . ELEVATION = 327.71 FEET.
BASIS OF BEARINGS:
N125'28"E BETWEEN MONUMENTS FOUND IN PLACE ALONG THE EAST LINE OF SE 1/4, SEC. 3-23-5
YLP 07.13.15 MAJ SURVEYED: iS
DESIGNED:
DRAWN:
wyc
CHECKED:
MAFJ
BY DATE AP P R APPROVED:
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
NORTH
GRAPHIC SCALE
0 25 50 100
1 INCH = 50 FT.
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
MATM
LEGEND:
DRAWINGS NOT APPROVED
FOR CONSTRUCTION UNLESS
STAMPED OR SIGNED APPROVED
BY THE REVIEWING AGENCY
t
CITY OE
RENTON
Planning/Building/Public Works Dept.
S-383501
R- 3835 15
IN COMPLIANCE WITH CITY OF RENTON
BYE
FOUND SECTION MONUMENT AS NO TED
®
FOUND MONUMENT AS NOTED
-�
ROAD SIGNAGE
BY:
MAIL BOX
®
POWER METER
+
POWER POLE
a
JUNCTION BOX, SIZE VARIES
#
LIGHT POLE NO ARM
GUY WIRE
®
WATER METER
WA TER VAL VE
C
FIRE H YDRAN T
®
TYPE 1 CA TCH BASIN
OO
STORM DRAIN MANHOLE
®
SANITARY MANHOLE
C0
ROCKERY
C.O.R.
Cl TY OF RENTON
VBF
VERTICAL BOARD FENCE
H B F
HORIZONTAL BOARD FENCE
D
DECIDUOUS TREE
EVERGREEN TREE
SANITARY SEWER LINE
STORM LINE
-OP-
OVERHEAD POWER
P
UNDERGROUND POWER
w
UNDERGROUND WA TER
G
UNDERGROUND GAS
T
UNDERGROUND TELEPHONE
C
UNDERGROUND CABLE
` -X\
EDGE OF PAVEMENT
-X-X-
FENCE
DRAWINGS NOT APPROVED
FOR CONSTRUCTION UNLESS
STAMPED OR SIGNED APPROVED
BY THE REVIEWING AGENCY
t
CITY OE
RENTON
Planning/Building/Public Works Dept.
S-383501
R- 3835 15
IN COMPLIANCE WITH CITY OF RENTON
BYE
STANDARDS
Date:
BY:
Date:
BY:
Date:
BY:
Date:
MAERTINS RANCH
SANITARY SEWER PLAN
DATE:
01.20.2015
PAGE:
DRAWINGC15
PERMITS: U15-001308, 815-000196 =HFF` 15 OF: 20
DRS PROJECT N0. 14103 IAI-INININ NIAIA