Loading...
HomeMy WebLinkAboutS-383501SE 1/4 SECTION 3, MAE NEW B" if IN 450.40 (W) IE OUT 455.36 Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) HOLDINGS LLC r 0 -- [[FF LF::-: -�� UIED 1 D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 620 - 7TH AVENUE, KIRKLAND, WA 98033 N O . 0 425.827.3063 F 425.827.2423 REVISION TOWNSHIP 23 N. RANGE 5 E * W.M. R TINS RANCH SEWER STUBS LOT *STA TION FG IE AT MAIN LENGTH END 1E SLOPE (9) 1 0+30 471.2 457.61 44 464.20 15.00 2 1+13 473 4 460.21 43 468.63 19.58 3 1+66 476.0 461.87 42 471.43 22.77 4 0+52 476.0 463.81 41 471.70 19.24 5 2+58 475.8 467.20 74 470.30 4.19 6 2+26 475.7 466.88 86 470.20 3.86 7 1+41 475.5 466.06 34 470.42 12.82 8 0+57 475.4 465.17 34 470.46 15.55 9 1+02 475.5 464.36 36 470.71 17.63 10 0+42 475.8 463.68 36 470.63 19.29 11 1+70 475.3 462.01 35 471.46 27.00 12 1+17 472.5 460.32 34 468.70 24.64 13 0+32 469.5 1 457.67 33 1 465.32 1 23.19 NO TES: 1. STATION IS TO NEAREST DOWNSTREAM MANHOLE 2. END IE IS AT STUB END J. CONTRACTOR TO VERIFY ELEVATION OF EXISTING HOME'S SEWER PRIOR TO CONNECTION. UTILITY CONFLICT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCA TE A T 811 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES A T LOCA TIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCA TIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIA TION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSUL T D. R. STRONG CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING W1 TH CONSTRUCTION. NO TES.- 1. ES:1. ALL TRENCH RES TORA TION SHALL BE PER THE CURRENT CITY OF RENTON TRENCH RESTORATION AND STREET OVERLAY DETAIL. PER SECTION 7 REQUIREMENT FOR PATCHING, OVERLAY, OVERLAY KID THS, TRENCHES (ROAD CROSSINGS). IF THE OUTSIDE OF THE TRENCHING IS Wl THIN THREE FEET (3) OF ANY ADJACENT LANE LINE, THE ENTIRE ADJACENT TRAVELED LANE AFFECTED WILL BE REPAVED. 2. REFER TO C20 FOR UTILITY CROSSINGS. J. MINIMUM SIDE SEWER SLOPE IS 2.009: 4. MINIMUM SIDE SEWER DEPTH IS 5 -FEET FROM FINISHED FLOOR ELEVATION. 5. ALL SSMH WILL BE A MINIMUM OF 48 -INCH DIAMETER. 6. ALL SIDE SEWER TO BE INSTALLED AT A MINIMUM OF 8 FEET INTO THE LOTS DAYLIGHT BASEMENT LOTS NOTE.- LOTS E:L0TS 11-13 TO UTILIZE PRI VA TE EJECTION PUMP FOR LOWER FLOOR. THE SEWER WILL BE PUMPED TO THE UPPER FLOOR AND THEN GRA VI TY DRAIN TO SEWER MAIN. HORIZON TA DA TUM.- NAD UM:NAD 1983/91 PER CITY OF RENTON MONUMENTS. VIER TI CAL DA TUM: NA VD 88, PER CITY OF RENTON VER TI CAL CONTROL. BENCHMARK.- 1. ENCHMARK:1. CITY OF RENTON CONTROL POINT NO. 1845. SE, CORNER SEC. 3-23-5. FOUND CONCRETE MONUMENT WITH PUNCHED BRASS PLUG, DOWN 1.7; IN MONUMENT CASE. ELEVATION = 467.76 FEET. 2. CITY OF RENTON CONTROL POINT NO. 2097 NEE, CORNER SEC. 3-23-5. FOUND STONE MONUMENT WITH FAINT X, DOWN 1.7; IN MONUMENT CASE. . ELEVATION = 327.71 FEET. BASIS OF BEARINGS: N125'28"E BETWEEN MONUMENTS FOUND IN PLACE ALONG THE EAST LINE OF SE 1/4, SEC. 3-23-5 YLP 07.13.15 MAJ SURVEYED: iS DESIGNED: DRAWN: wyc CHECKED: MAFJ BY DATE AP P R APPROVED: SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NORTH GRAPHIC SCALE 0 25 50 100 1 INCH = 50 FT. VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 MATM LEGEND: DRAWINGS NOT APPROVED FOR CONSTRUCTION UNLESS STAMPED OR SIGNED APPROVED BY THE REVIEWING AGENCY t CITY OE RENTON Planning/Building/Public Works Dept. S-383501 R- 3835 15 IN COMPLIANCE WITH CITY OF RENTON BYE FOUND SECTION MONUMENT AS NO TED ® FOUND MONUMENT AS NOTED -� ROAD SIGNAGE BY: MAIL BOX ® POWER METER + POWER POLE a JUNCTION BOX, SIZE VARIES # LIGHT POLE NO ARM GUY WIRE ® WATER METER WA TER VAL VE C FIRE H YDRAN T ® TYPE 1 CA TCH BASIN OO STORM DRAIN MANHOLE ® SANITARY MANHOLE C0 ROCKERY C.O.R. Cl TY OF RENTON VBF VERTICAL BOARD FENCE H B F HORIZONTAL BOARD FENCE D DECIDUOUS TREE EVERGREEN TREE SANITARY SEWER LINE STORM LINE -OP- OVERHEAD POWER P UNDERGROUND POWER w UNDERGROUND WA TER G UNDERGROUND GAS T UNDERGROUND TELEPHONE C UNDERGROUND CABLE ` -X\ EDGE OF PAVEMENT -X-X- FENCE DRAWINGS NOT APPROVED FOR CONSTRUCTION UNLESS STAMPED OR SIGNED APPROVED BY THE REVIEWING AGENCY t CITY OE RENTON Planning/Building/Public Works Dept. S-383501 R- 3835 15 IN COMPLIANCE WITH CITY OF RENTON BYE STANDARDS Date: BY: Date: BY: Date: BY: Date: MAERTINS RANCH SANITARY SEWER PLAN DATE: 01.20.2015 PAGE: DRAWINGC15 PERMITS: U15-001308, 815-000196 =HFF` 15 OF: 20 DRS PROJECT N0. 14103 IAI-INININ NIAIA u - D � rn ■� ^ Irl, z �= c 0 N - m m m cn O D cn A 0 m D C