Loading...
HomeMy WebLinkAboutR-383808Ld z U D O ry W a z W J I.i LSI 0 0 ry Ld I 0 AML W Q W Q U Z Ld W Z 4 ..... ... . ......... Lo. ..... ... IV /V NOTE. • BASE OF WALL MUST NOT BE PLACED ON FILL; FOOTING SHOULD EXTEND TO NA TI VE BEARING SOIL. /El D.R. STRONG CONSUL TING ENGINEERS ED :Slll E:) ENGINEERS PLANNERS SURVEYORS LLL ti r 620 7THAVENUE, KIRKLAND, WA 98033 0 425.827.3063 F 425.827.2423 vO\ / II %J/U.V BW 378.0 SE 1/4 SECTION 14., TOWNSHIP 23 N. RANGE 5 E, W.M. THE ENCLA VEA T BRIDLE RIDGE CITY COMMENTS 11.13.14 CITY COMMENTS CITY COMMENTS M 1 I ARS REVISION ART KEYS M6I E END KEYSTONE WAL LL ��, TW 384.4 386.0 %,, B W 383A, V 384.0 MAJ 02.13.15 Date: SURVEYED`: is Date: 05.19.15 Date: 7L110 DESIGNED: YL' MAJ 07.13.15 MAJ MAJ 07.23.15 MAJ DRAWN: YLP CHECKED: MAJ BY DATE I AP P R APPROVED: MA.! SC Sl TE VOLUME CAL COLA TIONS CUT VOLUME FILL VOLUME NET VOLUME (CU. YDS) (CU. YDS.) (CU. YDS.) 5, 331 30, 752 25,421 FILL (INCLUDES POND) ALL VOLUMES ARE APPROXIMA TE AND REPRESENT EXCA VA 77ON FOR RESIDENCE AS PROPOSED. 7HE VOLUMES DO NOT INCLUDE EXPANSION FACTOR OR ANY SOIL TYPE RESTRICTIONS THE VOLUMES DO NOT INCLUDE STRUCTURAL EXCA VA TION FOR BUILDINGS. VER TICAL DA TUM: NAVO 88 PER KING COUNTY DEPARTMENT OF PUBLIC WORKS SURVEY BRANCH (KCDPWSB) VER77CAL CON7ROL. SOIL NO TES: 1. THE SOIL MOISTURE HOLDING CAPACITY OF ALL NEW PERVIOUS SURFACE THA T A T PROJECT COMPLE77ON WILL NOT BE COVERED BY IMPERVIOUS SURFACE OR INCORPORATED INTO A DRAINAGE FACILITY MUST BE PROTECTED. THE DUFF LAYER AND NA 77VE TOPSOIL SHALL BE RETAINED IN AN UNDISTURBED STA 7E TO THE MAXIMUM EXTENT FEASIBLE. 2. ANY DUFF LAYER OR TOPSOIL REMOVED DURING GRADING SHALL BE STOCKPILED ONSI7E IN A DESIGNATED, CONTROLLED AREA NOT ADJACENT TO PUBLIC RESOURCES AND CRI77CAL AREAS. THE MA7ERIAL SHALL BE REAPPLIED TO OTHER POR77ONS OF THE S17E WHERE FEASIBLE. 3. THE SOIL IN ANY AREA 774A T HAS BEEN COMPACTED OR THAT HAS HAD SOME OR ALL OF THE DUFF LAYER OR UNDERLYING TOPSOIL REMOVED SHALL BE AMENDED TO M171GA 7E FOR LOST OF MOISTURE -HOLDING CAPACITY. 774E AMENDMENT SHALL TAKE PLACE BETWEEN MAY 1 AND OCTOBER 1. REPLACED TOPSOIL SHALL BE A MINIMUM 8 INCHES THICK. REPLACED TOPSOIL SHALL HAVE AN ORGANIC MATTER CONTENT BETWEEN 8 AND 13 PERCENT DRY WEIGHT AND A PH SUITABLE FOR THE PROPOSED LANDSCAPE PLANTS CURB RETURN NO 7E.- SEE E: SEE SHEET C9 FOR CURB RETURN AND ADA RAMP GRADING VERTICAL: NAVD 1988 AS NOTED HORIZONTAL: NAD 1983/1991 " CITY OF � RENTON ONE INCHDATM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY WALL NO TES: 1. KEYSTONE WALL DESIGN BY OTHERS 2. CIP WALL DESIGN BY OTHERS J. ROCKERY DESIGN BY OTHERS 4. SEPARATE BUILDING PERMIT REVIEW IS REQUIRED FOR ALL WALLS EXCEEDING 4 FEET IN HEIGHT. STRUCTURAL REVIEW OF WALLS WILL BE DONE K1774 BUILDING PERMIT. GEO TECH RECOMMENDA TIONS: STRUCTURAL FILL SOILS PLACED THROUGHOUT FOUNDA 770N, SLAB, AND PAVEMENT AREAS SHOULD BE PLACED OVER A FIRM BASE. LOOSE OR OTHERWISE UNSUITABLE AREAS OF NA 77VE SOILS EXPOSED AT SUBGRADE ELEVATIONS SHOULD BE COMPACTED TO STRUCTURAL FILL REQUIREMENTS OR OVEREXCA VA 7ED AND REPLACED WITH A SUITABLE STRUCTURAL FILL MATERIAL. WHERE STRUCTURAL FILL SOILS ARE USED TO CONSTRUCT FOUNDATION SUBGRADE AREAS, THE SOIL SHOULD BE COMPACTED TO 774E REQUIREMENTS OF STRUCTURAL FILL DESCRIBED IN 774E FOLLOWING SECTION. FOUNDA 77ON SUBGRADE AREAS SHOULD BE PROTEC7ED FROM DISTURBANCE, CONS7RUC77ON TRAFFIC, AND EXCESSIVE MOISTURE. WHERE INSTABILITY DEVELOPS BELOW STRUCTURAL FILL AREAS, USE OF A WOVEN GE07EX77LE BELOW THE S7RUCTURAL FILL AREAS MAY BE REQUIRED. A REPRESENTA TI VE OF ESNW SHOULD OBSERVE STRUCTURAL FILL PA VEMENT IN FOUNDA TION, SLAB AND PA VEMENT AREAS WET SEASON GRADING PERCHED GROUND WA TER WAS PRESEN T A T A NUMBER OF 774E TEST PI IS NEAR THE CONTACT BETWEEN THE WEA 7HERED SOIL AND UNDERLYING UNWEATHERED GLACIAL TILL SOIL. THIS CONDITION COUPLED W1'TH THE MODERA 7E TO HIGH MOISTURE SENSI TI W TY OF THE SOIL WILL MAKE GRADING DURING PERIODS OF RAIN MODERA TEL Y DIFFICULT MASS GRADING SHOULD TAKE PLACE DURING THE LATE SUMMER MON THS WHEN CONDITIONS ARE MORE FAVORABLE. IF GRADING TAKES PLACE DURING THE WETTER WINTER OR SPRING MONTHS, A CONTINGENCY IN THE PROJECT BUDGET SHOULD BE INCLUDED TO ALLOW FOR EXPORT OF NA TI VE SOIL AND IMPORT OF STRUCTURAL FILL AS DESCRIBED BELOW. IMPORTED SOILS IMPORTED SOIL INTENDED FOR USE AS STRUCTURAL FILL SHOULD CONSIST OF A WELL GRADED GRANULAR SOIL WITH A MOISTURE CONTENT THAT IS AT OR NEAR THE OPTIMUM LEVEL. DURING WET WEATHER CONDI RONS, IMPORTED SOIL INTENDED FOR USE AS STRUCTURAL FILL SHOULD CONSIST OF A WELL GRADED GRANULAR SOIL WITH A FINES CONTENT OF 5 PERCENT OR LESS DEFINED AS THE PERCENT PASSING THE #200 SIEVE, BASED ON 774E MINUS THREE—QUARTER INCH FRACTION. STRUCTURAL FILL STRUCTURAL FILL IS DEFINED AS COMPAC7ED SOIL PLACED IN FOUNDATION, SLAB—ON—GRADE, AND ROADWAY AREAS. FILLS PLACED TO CONSTRUCT PERMANENT SLOPES AND THROUGHOUT RETAINED WALL AND UTILITY 7RENCH BACKFILL AREAS ARE ALSO CONSIDERED STRUCTURAL FILL. SOILS PLACE IN STRUCTURAL AREAS SHOULD BE PLACED IN LOOSE LIFTS OF 12 INCHES OR LESS AND COMPACTED TO A RELATIVE COMPACTION OF 90 PERCENT, BASED ON 774E LABORATORY MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR METHOD (ASTM D-1557). SOIL PLACED IN U77LI TY 7RENCHES, PAVEMENT AREAS AND IN THE UPPER 12 INCHES OF SLAB—ON—GRADE AREAS SHOULD BE COMPACTED TO A RELATIVE COMPACTION OF AT LEAST 95 PERCENT. ADDITIONALLY, MORE STRINGENT COMPAC770N SPECIFICA 77ONS MAY BE REQUIRED FOR UTILITY TRENCH BACKFILL ZONES, DEPENDING ON THE RESPONSIBILITY UTILITY DISTRICT OR JURISDICTION. PA VEMEN T RES TORA TION NO TES WI THIN CITY LIMITS, PAVEMENT RESTORA 77ON SHALL BE PER C.O.R. S7REET RESTORATION AND STREET OVERLAY STANDARDS AND/OR AS FIELD SPECIFIED BY 774E CITY INSPECTOR. PAVEMENT RESTORATION FOR SEWER INSTALLATION WITHIN KING COUNTY LIMITS SHALL BE PER APPROVED KING COUNTY RIGHT OF WA Y PERMI T. R-381308 NORTH GRAPHIC SCALE 0 20 40 80 1 INCH = 40 FT. RECOMMENDED FOR APPOVAL BY: Date: BY: Date: BY: Date: BY: =A&" Date: 7L110 THE ENCLAVE AT BRIDLE RIDGE I 10.03.14 PAE GRADING PLANIDRGA—Wl CB U14005368 SHEET: e OF: 29 DRS PROJECT N0. 13117 JAI-ININININItAIA Z C m