Loading...
HomeMy WebLinkAboutORD 5085Amends Ords 4351,4400, 4450,4546,4673,4722, 4768,5010 Amended by Ord:5153,5157,5159, 5297 CITY OF RENTON,WASHINGTON ORDINANCE NO.5085 AN ORDINANCE OF THE CITY OF RENTON,WASHINGTON, AMENDING SECTION 4-1-140 OF CHAPTER 1,ADMINISTRATION AND ENFORCEMENT,AND SECTIONS 4-5-050,4-5-055,4-5-090, 4-5-100, AND 4-5-110 OF CHAPTER 5,BUILDING AND FIRE PREVENTION STANDARDS,OF TITLE IV (DEVELOPMENT REGULATIONS)OF ORDINANCE NO.4260 ENTITLED "CODE OF GENERAL ORDINANCES OF THE CITY OF RENTON,WASHINGTON"BY AMENDING THE FEE SCHEDULE AND ADOPTING THE INTERNATIONAL BUILDING,RESIDENTIAL,MECHANICAL,AND FUEL GAS CODES,AND THE UNIFORM PLUMBING CODE,AND AMENDMENTS THERETO. THE CITY COUNCIL OF THE CITY OF RENTON,WASHINGTON,DO ORDAIN AS FOLLOWS: SECTION I.Sections 4-1-140.A and B of Chapter 1,Administration and Enforcement,of Title IV (Development Regulations)of Ordinance No.4260 entitled "Code of General Ordinances of the City ofRenton,Washington"are hereby amended to read as follows: A.BUILDING PERMIT FEES: Payable prior to issuance of building permit. TOTAL FEE:VALUATION: $1.00 to $500.00 $28.00 $501.00 to $28.00 for the first $500.00 plus $3.65 for each additional $2,000.00 $100.00,or fraction thereof,to and including $2,000.00 $2001.00 to $82.75 for the first $2,000.00 plus $16.75 for each additional $25,000.00 $1,000.00,or fraction thereof,to and including $25,000.00 $25,001.00 to $468.00 for the first $25,000.00 plus $12.00 for each $50,000.00 additional $1,000.00,or fraction thereof,to and including $50,000.00 $50,001.00 to $696.00 for the first $50,000.00 plus $8.35 for each additional $100,000.00 $1,000.00,or fraction thereof,to and including $100,000.00 $100,001.00 to $1113.50 for the first $100,000.00 plus $6.70 for each 1 ORDINANCE NO.5085 $500,000.00 additional $1,000.00,or fraction thereof,to and including $500,000.00 $500,001.00 to $3793.50 for the first $500,000.00 plus $5.65 for each $1,000,000.00 additional $1,000.00,or fraction thereof,to and including $1,000,000.00 $1,000,001.00 and $6615.50 for the first $1,000,000.00 plus $4.35 for each up additional $1,000.00,or fraction thereof B.COMBINATION BUILDING PERMIT FEES: For each new single family residential structure.Payable prior to issuance of building permit. TYPE OF PLUS FEE AMOUNT BASED UPON RESIDENTIAL WORK STRUCTURE SQUARE FOOTAGE Up to 3,000 sq.ft.Over 3,000 sq.ft. Plumbing $150.00 $175.00 Mechanical $150.00 $175.00 Electrical $75.00 $100.00 SECTION II.Section 4-1-140.E of Chapter 1,Administration and Enforcement, of Title IV (Development Regulations)of Ordinance No.4260 entitled "Code of General Ordinances ofthe City of Renton,Washington"is hereby deleted. SECTION III.Section 4-1-140.F of Chapter 1,Administration and Enforcement, of Title IV (Development Regulations)of Ordinance No.4260 entitled "Code of General Ordinances ofthe City ofRenton,Washington"is hereby amended to read as follows: F.ELECTRICAL PERMIT FEES: 1.RESIDENTIAL FEES -SINGLE FAMILY AND DUPLEX a.New Service -Single Family and Duplex: 2 ORDINANCE NO.5085 Up to 200 AMP $70.00 Over 200 AMP $80.00 b.Service ChangeslNew Circuits -Single Family and Duplex: Change up to 200 AMP $45.00 Change over 200 AMP $60.00 Any new circuits added to above $15.00 each (to a maximum of$45.00) Minimum fee for remodeVaddition of new circuits without a service charge $45.00 2.MULTI-FAMILY,COMMERCIAL AND INDUSTRIAL FEES Fees for all types of electrical permits are based on value of work: $1.00 -250.00 $45.00 $250.01 -1,000.00 $45.00 + 3.3%of cost $1,000.01 -5,000.00 $78.00+ 2.9%of value $5,000.01 -50,000.00 $223.00 +1.7%of value $50,000.01 -250,000.00 $1073.00 +1.0%of value $250,000.01 -1,000,000.00 $3573.00 +0.8%of value $1,000,000.01 and up -$11,573.00+ 0.45%of value 3.TEMPORARY ELECTRICAL SERVICES -$45.00 4.MISCELLANEOUS ELECTRICAL FEES Job Trailers $45.00 each Signs $45.00 each 3 ORDINANCE NO.5085 Swimming Pools,Hot Tubs,Saunas $60.00 each Mobile Homes $45.00 Low Voltage Work (e.g.,alarm systems;thermostats; computer,data,or phone lines;fibre optics,cable 50%of standard fee television,etc.) 5.Exemption:Residential telephone communication systems,thermostats,security systems,and cable television installations are exempt from fees under this Section. SECTION IV.Sections 4-1-140.K and L of Chapter 1,Administration and Enforcement,of Title IV (Development Regulations)of Ordinance No.4260 entitled "Code of General Ordinances ofthe City ofRenton,Washington"are hereby amended to read as follows: K.MECHANICAL PERMIT FEES: BASIC PERMIT FEE: $45.00 Plus Itemized Fees Below: Heating and Air Conditioning System: Installation,alteration,repair,addition,or relocation of each:Heating system (furnace,heat pump,suspended heater,fireplace,wood stove, $17.00etc.AlC system:(air conditioner,chiller or Air Handling Unit (VAV) including ducts and vents Boiler or Compressor: Installation or relocation of each: to and including 3 horsepower $17.00 over 3 horsepower to and including 15 horsepower $30.00 over 15 horsepower to and including 30 horsepower $40.00 over 30 horsepower to and including 50 horsepower $60.00 4 ORDINANCE NO.5085 over 50 horsepower $100.00 Absorption System:- Installation or relocation of each:- to and including 100,000 Btulh $17.00 over 100,000 Btu/h to and including 500,000 Btulh $30.00 over 500,000 Btulh to and including 1,000,000 Btulh $40.00 over 1,000,000 Btu/h to and including 1,750,000 Btulh $60.00 over 1,750,000 Btulh $100.00 Residential ventilation/exhaust fan $8.00 Plus Itemized Fees Below:each Commercial ventilation/exhaust system not a portion of any heating $17.00 or air-conditioning system authorized by a permit each Commercial Hood: Installation of each served by a mechanical exhaust,including the $50.00 ducts for such hood each Incinerator: Installation or relocation of each $75.00 each Appliance or piece of equipment regulated by this code but not $17.00classedinotherappliancecategories,or for which no other fee is listed in this code each Fuel Gas Piping: Each gas-piping system of 1 to 4 outlets $12.00 Each gas-piping system of 5 or more outlets,per outlet $2.50 L.PLUMBING PERMIT FEES: BASE FEE FOR ALL TYPES OF WORK: Plus Itemized Fees Below: 5 $45.00 ORDINANCE NO.5085 Per plumbing fixture (e.g.sink,shower,toilet, $8.00dishwasher,tUb,etc.)or set of fixtures on one trap For meter to house water service $8.00 Per outlet associated with a gas piping system up to 5:$12.00 additional outlets are $2.50 each Per drain for rainwater systems $8.00 Per lawn sprinkler system -includes backflow $8.00prevention Per fixture for repair or alteration of drainage or $8.00ventpiping Per vacuum breaker or backflow protection device $8.00ontanks,vats,etc. Per interceptor for industrial waste pretreatment $8.00 SECTIONV.The title to Section 4-5-010 of Chapter 5,Building and Fire Prevention Standards,of Title IV (Development Regulations)of Ordinance No.4260 entitled "Code of General Ordinances of the City ofRenton,Washington"is hereby amended to read as follows: 4-5-010 CODES ADOPTION OF STATE,NATIONAL,UNIFORM,AND INTERNATIONAL SECTION VI.Section 4-5-050,International Building Code,of Chapter 5, Building and Fire Prevention Standards,of Title IV (Development Regulations)of Ordinance No.4260 entitled "Code of General Ordiriances ofthe City of Renton,Washington"is hereby amended to read as follows: 4-5-050 INTERNATIONAL BUILDING CODE A.ADOPTION: 6 ORDINANCE NO.5085 The "International Building Code,"2003 Edition,as published by the "International Code Council,Inc."as amended by chapter 51-40 WAC is hereby adopted by reference. B.APPLICABILITY: It shall be unlawful for any person,firm or corporation to erect,construct,enlarge,alter, repair,move,improve,remove,convert or demolish,equip,use,occupy or maintain any building or structure in the city,or cause or permit the same to be done,contrary to or in violation of any ofthe provisions ofthis Code. C.STATE AMENDMENTS TO THE INTERNATIONAL BUILDING CODE: The International Building Code,2003 Edition,as amended by chapter 51-40 WAC,is hereby adopted by reference and as an amendment to the International Building Code and shall supersede conflicting sections ofthe International Building Code. D.CITY AMENDMENTS TO THE INTERNATIONAL BUILDING CODE: 1.Dangerous Buildings:Section 115 ofthe International Building Code (relating to Dangerous Buildings)is hereby repealed and in its place the City has adopted RMC 4-5-060 and 4-9-050,Abatement ofDangerous Buildings. 2.Violations and Penalties:Section 113 ofthe International Building Code (relating to Violations and Penalties)is hereby amended by substituting in its stead subsection A ofthis Section,Applicability,and RMC 1-3-2,Civil Penalties. 3.Liability Claims:Section 104.8 ofthe International Building Code (relating to Liability Claims)is hereby amended by substituting in its stead RMC 4-1-090,Liability. 4.Appeals Board:The Appeals Board for purposes of section 112 ofthe International Building Code shall be the Board of Adjustment. 7 ORDINANCE NO.5085 5.Off-Site Improvements:Section 105.3 ofthe International Building Code (relating to Installation of Off-Site Improvements)is hereby amended by substituting in its stead RMC 4- 4-030.D,Off-Site Improvements. 6.Standpipe Requirements:Section 905.3 ofthe International Building Code is amended to read as follows: a.905.3.1 Building Height.Class III standpipe systems shall be installed throughout a building where the floor level ofthe highest story is located more than 20 feet above the lowest level of the fIre department vehicle access,or where the floor level ofthe lowest story is located more than 20 feet below the highest level of fIre department vehical access. Exceptions: (1 )Class I standpipes are allowed in buildings equipped throughout with an automatic sprinkler system in accordance with section 903.3.1.1 or 903.3.1.2. (2)Class I manual standpipes are allowed in open parking garages where the highest floor is located not more than 150 feet above the lowest level of fIre department vehical access. (3)Class I manual dry standpipes are allowed in open parking garages that are subject to freezing temperatures,provided that the hose connections are located as required for Class II standpipes in accordance with Section 905.5. (4)Class I standpipes are allowed in basements equipped throughout with an automatic sprinkler system. (5)Group R-3 does not require standpipes. 8 ORDINANCE NO.5085 b.905.3.7 High Rise Building Standpipes.Standpipe risers shall be combination standpipe/sprinkler risers using a minimum pipe size of 6 in.Two-2 ~in.hose connections shall be provided on every intermediate floor level landing in every required stairway unless otherwise approved by the fire code official.Where pressure reduction valves (PRV)are required,each hose connection shall be provided with its own PRY.The system shall be designed to provide a minimum flow of 300 gpm at a minimum pressure of 150 psi (maximum 200 psi)at each standpipe connection,in addition to the flow and pressure requirements contained in NFPA 14. 7.Dry standpipes.Section 905.8 of the International Building Code is amended to read as follows: Dry standpipe when approved by the fire code official are acceptable in other than high- rise buildings. E.CITY AMENDMENTS TO TIIE mc RELATING TO SPRINKLER REQUIREMENTS: 1.Chapter 9:The following sections of chapter 9 ofthe 2003 International Building Code are amended to read as follows: a.Section 903.2,Where required.Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in this section. All newly constructed buildings with a gross square footage of 12,000 or greater square feet,regardless of type ofuse as well as zero lot line townhouses within an aggregate area of all connected townhouses equaling 12,000 square feet or greater square feet must be sprinklered. Additions to existing buildings which would result in a gross floor area greater than 12,000 square feet must be retrofitted with an automatic sprinkler system. 9 ORDINANCE NO.5085 Exception:One time additions to Group R-3 occupancies ofup to 500 square feet are permitted without compliance with this section. b.Section 903.2.1.1,Group A-I. An automatic sprinkler system shall be provided for Group A-I occupancies where one ofthe following conditions exists: (1)The gross floor area exceeds 12,000 square feet; (2)The fire area has an occupant load of 300 or more; (3)The fire area is located on a floor other than the level of exit discharge;or (4)The fire area contains a multi theater complex. c.Section 903.2.1.2,Group A-2.An automatic sprinkler system shall be provided for Group A-2 occupancies where one ofthe following conditions exists: (1)The gross floor area exceeds 5,000 square feet; (2)The fIre area has an occupant load of 100 or more;or (3)The fire area is located on a floor other than the level of exit discharge. d.Section 903.2.1.3,Group A-3.An automatic sprinkler system shall be provided for Group A-3 occupancies where one ofthe following conditions exists: (1)The gross floor area exceeds 12,000 square feet; (2)The fIre area has an occupant load of 300 or more;or (3)The fire area is located on a floor other than the level ofexit discharge. 10 ORDINANCE NO.5085 Exception:Areas used exclusively as participant sports areas where the main floor area is located at the same level as the level of exit discharge ofthe main entrance and exit. e.Section 903.2.1.4,Group A-4.An automatic sprinkler system shall be provided for Group A-4 occupancies where one of the following conditions exists: (1)The gross floor area exceeds 12,000 square feet; (2)The fire area has an occupant load of300 or more;or (3)The fire area is located on a floor other than the level of exit discharge. Exception:Areas used exclusively as participant sports areas where the main floor area is located at the same level as the level of exit discharge of the main entrance and exit. f.Section 903.2.2,Group E.An Automatic sprinkler system shall be provided for Group E occupancies where the gross floor area exceeds 12,000 square feet. EXCEPTIONS: (1)Portable school classrooms,provided aggregate area of clusters of portable school classrooms does not exceed 5,000 square feet;and clusters of portable school classrooms shall be separated as required in Chapter 5 ofthe building code. (2)Basements:An automatic sprinkler system shall be installed in basements classified as a Group E Occupancy when the basement is larger than fifteen hundred (1,500)square feet in floor area When not required by other provisions of his chapter,a fire-extinguishing system installed in accordance with NFPA-13 may be used for increases and substitutions allowed in Section 504.2,506.3,and Table 601 ofthe building code. 11 ORDINANCE NO.5085 (3)Throughout all newly constructed Group E Occupancies having an occupant load of 50 or more for more than 12 hours per week or four hours in anyone day.A minimum water supply meeting the requirements ofNFPA 13 shall be provided. (4)Stairs:An automatic sprinkler system shall be installed in enclosed usable space below or over a stairway in Group E Occupancies. g.Section 903.2.3,Group B,F,Hand S Occupancies.An automatic sprinkler system shall be provided throughout all buildings containing a Group B,F,H or S occupancy with over twelve thousand (12,000)square feet of gross floor area. h.Section 903.2.6,Group M.An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy where one ofthe following conditions exists: (1)Where a Group M gross floor area exceeds 12,000 square feet; (2)Where a Group M fire area is located more than three stories above grade;or (3)Where the combined area of all Group M fire areas on all floors, including any mezzanines,exceeds 12,000 square feet. 1.Section 903.2.7,Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area. J.Section 903 is amended by adding sections 903.2.7.1 and 903.2.7.2 to read as follows: Section 903.2.7.1-Group R-3 occupancy.When the occupancy has over twelve thousand (12,000)square feet of gross floor area. 12 ORDINANCE NO.5085 Section 903.2.7.2 -Dwellings.When proposed within all residential zones,clustered or constructed so that,when attached,the total square foot gross floor area of all dwelling units exceeds twelve thousand (12,000)square feet.For the purpose ofthis subsection,portions of buildings separated by one or more firewalls will not be considered a separate building. k.Section 903 is amended by adding section 903.2.14,to read as follows: 903.2.14 Automatic Sprinklers Systems in New Buildings: (1)Section 903.2.14.1 - A fully automatic fire protection sprinkler system is to be installed in all new buildings in excess oftwelve thousand (12,000)square feet total gross floor area,regardless of vertical or horizontal fire barriers,such sprinkler system shall be designed,installed and tested as per Section 903.3. (2)Section 903.2.14.2 -A fully automatic fire protection sprinkler system may be required by the Chief ofthe Fire Department or the Fire Code Official for buildings less than twelve thousand (12,000)square feet total gross floor area when,in their judgment,supported by written documentation from a professional organization (such as NFPA, ICC,SBCC D.L.,ISO,etc.)verify that hazardous contents,critical exposure problems,limited accessibility to the building,or other items may contribute to a definite hazard. 1.Section 903 is amended to add a new Section 903.2.15 to read as follows: Section 903.2.15 -Sprinkler Systems in Remodeled Buildings: (1)Section 903.2.15.1 -When existing buildings with full sprinkler systems are remodeled or added onto,the remodeled or added on portion shall be fully sprinklered. 13 ORDINANCE NO.5085 (2)Section 903.2.15.2 -When an existing building is added onto or remodeled and the resulting total square foot gross floor area exceeds twelve thousand (12,000) square feet,then the entire structure shall be fully sprinklered. F.WASlllNGTON STATE ENERGY CODE AND WASlllNGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE ADOPTED: The 2003 Washington State Energy Code as adopted by the State of Washington Second Edition (chapter 51-11 WAC)and 2003 Washington State Ventilation and Indoor Air Quality Code,Second Edition (chapter 51-13 WAC)are hereby adopted by reference. SECTION VII.A new section,4-5-055,International Residential Code,of Chapter 5,Building and Fire Prevention Standards,of Title IV (Development Regulations)of Ordinance No.4260 entitled "Code of General Ordinances ofthe City of Renton,Washington"is hereby added,to read as follows: 4-5-055 INTERNATIONAL RESIDENTIAL CODE: A.ADOPTION: The "International Residential Code,"2003 Edition,as published by the "International Code Council,Inc."as amended by chapter 51-40 WAC is hereby adopted by reference. B.APPLICABILITY: It shall be unlawful for any person,firm or corporation to erect,construct,enlarge,alter, repair,move,improve,remove,convert or demolish,equip,use,occupy or maintain any building or structure in the city,or cause or permit the same to be done,contrary to or in violation of any of the provisions of this Code. C.STATE AMENDMENTS TO TIIE INTERNATIONAL RESIDENTIAL CODE: 14 ORDINANCE NO.5085 The International Residential Code,2003 Edition,as amended by chapter 51-40 WAC,is hereby adopted by reference and as an amendment to the International Residential Code and shall supersede conflicting sections ofthe International Residential Code. D.CITY AMENDMENTS TO THE INTERNATIONAL RESIDENTIAL CODE: 1.Certificate of Occupancy:Section RIIO.1 ofthe International Residential code is hereby amended as follows. Exception:Certificates of Occupancy shall not be required for detached one and two family dwellings. 2.Violations and Penalties:Section Rl13.4 ofthe International Residential Code is hereby amended by substituting in its stead subsection A ofthis Section,Applicability,and RMC 1-3-2,Civil Penalties. 3.Appeals Board:The Appeals Board for purposes of section R112.1 ofthe International Residential Code shall hereafter be the Board ofAdjustment. SECTION VIII.Sections 4-5-090,4-5-100,and 4-5-110 of Chapter 5,Building and Fire Prevention Standards,of Title IV (Development Regulations)of Ordinance No.4260 entitled "Code of General Ordinances ofthe City of Renton,Washington"are hereby amended, to read as follows: 4-5-090 INTERNATIONAL MECHANICAL CODE: A.ADOPTION: The "Uniform Mechanical Code,2003 Edition,"as published by the "International Code Council"as amended by chapter 51-42 WAC is hereby adopted by reference. B.BOARD OF APPEALS: The Board of Appeals of section 109 shall be the Board of Adjustment. 15 ORDINANCE NO.5085 4-5-100 INTERNATIONAL FUEL GAS CODE A.ADOPTION: The International Fuel Gas Code 2003 Edition,"as published by the "International Code Council"as amended by chapter 51-42 WAC is hereby adopted by reference. B.BOARD OF APPEALS: The Board ofAppeals of section 109.1 shall be the Board of Adjustment. C.VIOLATIONS AND PENALTIES:The first paragraph of section 108.4 ofthe IFGC, relating to violations and penalties,is amended to substitute in its stead RMC 1-3-2,Civil Penalties. 4-5-110 UNIFORM PLUMBING CODE A.ADOPTION: The Uniform Plumbing Code,2003 Edition,as published by the "International Association ofPlumbing and Mechanical Officials"and chapters 51-56 and 51-57 WAC are hereby adopted by reference. B.STATE AMENDMENTS TO UNIFORM PLUMBING CODE: Whenever there is a discrepancy in the requirements between the Uniform Plumbing Code,2003 Edition,as published by the "International Association ofPlumbing and Mechanical Officials"and chapters 51-56 and 51-57 WAC,the Washington Administrative Code sections will be deemed to have amended the Uniform Plumbing Code,2003 Edition,as published by the "International Association ofPlumbing and Mechanical Officials." C.CITY AMENDMENTS TO UNIFORM PLUMBING CODE: 16 ORDINANCE NO.5085 Section 102.3:The first paragraph of section 102.3 ofthe UPC,relating to violations and penalties,is amended by substituting in its stead RMC 1-3-2,Civil Penalties. SECTION IX. 30 days after publication. This ordinance shall be effective upon its passage,approval,and PASSED BY THE CITY COUNCIL this 21st day of_J_u_n_e ,2004. Michele Neumann,Deputy City Clerk APPROVED BY THE MAYOR this 21 st day of_....;:J....;:u=n:....:::e ,2004. -<~Ii&-w~ Kathy Ke Iker-Wheeler,Mayor Approved as to form: £~~~; .Lawrence J.Warr~~€lty Attorney Date ofPublication:7/2/2004 (summary) ORD.1117:5/26/04:ma 17