HomeMy WebLinkAboutORD 4312Amended By ORO 4723 (Tr.to Title IV.Ch 6: CITY OF RENTON,WASHINGTON ORDINANCE NO.4312 AN ORDINANCE OF THE CITY OF RENTON,WASHINGTON,AMENDING CHAPTER 4,WATER,OF TITLE VIII (HEALTH &SANITATION),OF ORDINANCE NO.4260 ENTITLED "CODE OF GENERAL ORDINANCES OF THE CITY OF RENTON,WASHINGTON"BY ADDING A NEW SECTION RELATING TO CROSS COHHECTION CONTROL. THE CITY COUNCIL OF THE CITY OF RENTON,WASHINGTON,DO ORDAIN AS FOLLOWS: SECTION 1.Chapter 4,water,of Title VIII (Health & Sanitation),~f Ordinance No.4260 entitled "Code of General Ordinances of the City of Renton,Washington"is hereby amended by adding the following section: Section 8-4-45:CROSS CONNECTION CONTROL: A.Purpose.National standards of safe drinking water have been established.The City of Renton,as a water purveyor, has the primary responsibility for preventing water from unapproved sources,or any other substances,from entering the public potable water system. This ordinance is to protect the health of the water consumer and the potability of the water in the distribution system.This is accomplished by eliminating or controlling all actual (direct)and potential (indirect)cross connections between potable and non-potable systems through the use of approved backflow prevention assemblies. B.Definitions. AIR GAP:A physical vertical separation through the free atmosphere sufficient to prevent backflow between the free flowing discharge end of the potable water system and the overflow 1 ORDINANCE NO.4312 level of the receiving vessel,tank,plumbing fixture or any other system.Physically defined as a distance greater than or equal to twice the diameter of the supply pipe diameter,but in no case less than one inch. APPROVED:Approved in writing by the Department of Health or other agency having jurisdiction. ATMOSPHERIC VACUUM BREAKER:An assembly which prevents back siphonage by creating an atmospheric vent when there is either a negative pressure or subatmospheric pressure in the water system.It is designed to protect against back siphonage only. AUXILIARY SUPPLY:Any water source or system on or available to the premises other than the purveyor approved potable water supply. BACKFLOW:The flow of water or any other liquid,gas or substance from any source back into the distribution pipes of the potable water supply system. BACKPRESSURE:Backflow caused by a pump,elevated tank,boiler,or other means that could create pressure within the system greater than the potable water supply system. BACKSIPHONAGE:The flow of water or any other liquid,gases or substances from any source back into the distribution pipes of the potable water supply system caused by the reduction of pressure in the potable water supply system. BACKFLOW PREVENTER:An approved assembly which prevents the backflow of water or any other liquid,gas,or 2 ORDINANCE NO.4312 substance from any source back into the distribution pipes of the potable water supply system. BAROMETRIC LOOP:A fabricated piping arrangement rising at least thirty-five (35)feet at its topmost point above the highest fixture it supplies.It is used in water supply systems to protect against backsiphonage only. CONTAMINANT:A substance that will impair the quality of the water to a degree that it creates a serious health hazard. CROSS CONNECTION:Any physical or potential arrangement whereby a public water system is connected,directly or indirectly,with any other non-potable water system,drain,sewer, conduit,pool,storage reservoir,plUmbing fixture,or other device which contains,or may contain,contaminated water,sewer,or other waste liquid of unknown or unsafe quality which may be capable of imparting contamination to the pUblic water system as a result of backflow.Bypass arrangements,jumper connections,removable sections,swivel or change-over devices,or other temporary or permanent devices through which backflow may occur are considered to be cross connections. DOUBLE CHECK VALVE ASSEMBLY:An approved assembly composed of two single,independently acting check valves,either spring loaded or internally weighted,installed as a unit between two tightly closing shutoff valves and having suitable connections for testing. HEALTH HAZARD:A physical or toxic hazard which could be dangerous to health. 3 ORDINANCE NO.4312 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER:An is safe for human health authority having assembly consisting of two independently acting spring operated check valves,separated by a spring loaded differential pressure relief valve,which is installed as a unit between two tightly closing shutoff valves and having suitable connections for testing. POLLUTION:A hazard which could cause aesthetic problems or have a detrimental effect on the quality of water in the potable system. POTABLE WATER:Water which as described by "the publicconsumption, jurisdiction. PRESSURE VACUUM BREAKER:An assembly consisting of a spring loaded check valve and independently operating air inlet valve,inlet and discharge shutoff valve,and properly installed test cocks.The air inlet valve is internally loaded to the open position,normally by means of a spring.This internal loading allows the assembly to be installed on the pressure side of a shutoff valve.It is designed to protect against backsiphonage only. C.Application.This chapter applies throughout the water service area of the City of Renton.It applies to all systems installed prior to or after its enactment.Therefore, anyone wanting or using water from the City of Renton is responsible for compliance with these regulations and shall be strictly liable for all damage incurred as a result of failure to comply with the express terms and provisions contained herein. 4 ORDINANCE NO.4312 D.Enforcement.The Director of the Department of Planning/Building/Public Works will administer the provisions of the chapter.He/she will designate cross connection specialists and propound all needful rules and regulations to implement these provisions.The Water Utility Section of the Utility Systems Division will be responsible for monitoring and inspecting all existing cross connection assemblies and for keeping all records generated by the Cross Connection Control Program.The Plan Review Section of the Development Services Division will be responsible for reviewing all new and revised plans for cross connections. E.Installation of Backflow Prevention Assemblies. Backflow prevention assemblies required by this chapter must be installed so as to be readily accessible for maintenance and testing.All assemblies shall be connected at the meter,the property line when meters are not used,or within any premise where,in the jUdgement of the City of Renton Cross Connection Control Specialist,the nature and extent of activity on the premises or the materials used or stored on the premises could present a health hazard should a cross connection occur.This includes: 1.Premises having an auxiliary water supply. 2.Premises having internal cross connections that are not correctable,or intricate plumbing arrangements which make it impractical to ascertain whether or not cross connections exist. 3.P.remises where entry is restricted so that inspections for cross connections cannot be made with sufficient 5 ORDINANCE NO.4312 frequency or at sufficient short notice to assure that cross connections do not exist. 4.Premises having a repeated history of cross connections being established or reestablished. 5.Premises on which any substance is handled under pressure so as to permit entry into the public water system, or where a cross-connecting could reasonably be expected to occur. This includes the handling of process waters and cooling waters. 6.Premises where materials of a toxic or hazardous nature are handled such that if backsiphonage should occur,a health hazard may result. 7.Hospitals,mortuaries,clinics. 8.Laboratories. 9.Piers and docks. 10.Sewage treatment plants. 11.Food or beverage processing plants. 12.Chemical plants using a water process. 13.Metal plating industries. 14.Petroleum processing or storage plants. 15.Radioactive material processing plants or nuclear reactors. 16.Car Washes. 17.Process waters or cooling towers. 18.Fire sprinkler systems. 19.Irrigation systems. 20.Solar hot water systems. 6 ORDINANCE NO.4312 21.Others specified by the Director of the Department of Planning/Building/Public Works Administrator. F.Types of Backflow Prevention Assemblies Required. Specific types of backflow prevention assemblies are required in the following conditions: 1.An air-gap separation or reduced principle backflow prevention assembly shall be installed where the water supply may be contaminated by industrial waste of a toxic nature or any other contaminant which would cause a health or system hazard. 2.An air gap must be used between a potable water supply and sewer connected wastes. 3.Lawn sprinkler or irrigation systems,which are supplied by City water only,shall be required to have a pressure vacuum breaker.If such system contains an auxiliary pump or is subject to chemical additives a double-check valve assembly,air- gap separation,or a reduced pressure principle backflow prevention assembly will be required. G.Responsibilities of Owner and Utility. 1.Water Utilities Section. a.The Water Utilities Section will perform evaluations and inspections of plans/or premises of all existing facilities and inform the owner,by letter,of any corrective action deemed necessary,the method of achieving the correction, and the time allowed for the correction to be made. b.The Water Utilities Section shall insure that all , backflow prevention assemblies are tested annually to insure satisfactory operation. 7 ORDINANCE NO.__4_3_1_2_ c.The Water Utilities Section shall inform the owner,by letter,of any failure to comply by the time of the first reinspection.An additional fifteen (15)days will be allowed for the correction.In the event the owner fails to comply with the necessary correction by the time of the second reinspection,the Water Utilities Section will inform the owner,by letter,that the water service to the owner's premises will be terminated within a period not to exceed five (5)days. d.If the Water Utilities Section determines at any time that a serious threat to the pUblic health exists,the water service will be terminated immediately and without notice. 2.Plan Review Section.On new installations the Plan Review Section will provide on-site evaluation and/or inspection of plans in order to determine if cross connections exist and what type of backflow preventer,if any,will be required before a water meter permit can be issued. 3.Owner. a.The owner shall be responsible for the elimination or protection of all cross connections on his property. b.The owner,whether notified by the City or not,shall at his expense install,maintain,and have tested by a certified tester any and all backflow preventers on his premises. c.The owner shall return to the City of Renton the assembly test reports within thirty (30)days after receipt of the yearly test notification. d.The owner shall inform the Water Utilities Section of any proposed or modified cross connections. 8 ORO INANCE NO.4312 The owner shall install backflow manner approved by the Washington State e.Owners who cannot shut down operation for testing of assemblies must provide bypass piping with an additional backflow assembly at their expense. f.The owner shall only install backflow preventers which are approved by the Washington State Department of Health. g. preventers only in a Department of Health. h.The owner may be required to install a backflow preventer at the service entrance if a private water source is maintained on his premises,even if it is not cross connected to the City's system. i.Failure of the owner to cooperate in the installation,maintenance,repair,inspection and testing of backflow preventers required by this ordinance shall be grounds for the termination of water service or the requirements of an air gap separation. H.Annual Inspection and Testing Requirements.All reduced pressure principle backflow assemblies,double check valve assemblies,pressure vacuum breaker assemblies,and air gaps installed in lieu of a backflow preventer shall be inspected and tested annually,or more often when successive inspections indicate failure.All inspections and testing will be performed by a certified tester.The test reports shall be returned to the City of Renton within thirty(30)days after receipt of the yearly test notification. 9 ORDINANCE NO.4312 SECTION II.This Ordinance shall be effective upon its passage,approval,and thirty days after publicatioQ. PASSED BY THE CITY COUNCIL this 13th day of dLJrv"vw',AArTV/\N' Marilyn ___M_a.....y~_,1991. Clerk APPROVED BY THE MAYOR this 13th day of f1ay ,1991. Date of Publication:Published in Summary -May 17,1991 ORD.178:4/16/91:as. 10