Loading...
HomeMy WebLinkAboutORD 3535 i AMENDS 3142 1959 off. 3741 CITY OF RENTON , WASHINGTON ORDINANCE NO. 3535 AN ORDINANCE OF THE CITY OF RENTON, WASHINGTON , AME14DING PORTIONS OF TITLE VII(FIRE REGULATIONS) OF ORDINANCE NO . 1628 ENTITLED "CODE OF GE14ERAL ORDINANCES OF THE CITY OF RENTON" RELATING TO INCORPORATION BY REFERENCE OF THE FIRE CODE , ADOPTING THE 1979 UNIFORM FIRE CODE WITH AMENDMENTS. THE CITY COU14CIL OF THE CITY OF RENTON , WASHINGTON, DO ORDAIN AS FOLLOWS : SECTION I : The City of Renton does hereby adopt the 1979 Uniform Fire Code and Appendices A through I thereto by reference as provided by State Law, with the amendments , deletions or exceptions as noted herein. At least three (3) copies of the Uniform Fire Code are on file with the City Clerk as required by State Law. SECTION II : Section 2 . 101 of the Uniform Fire Code , 1979 Edition, is hereby amended to read as follows : Section 2 . 101 . The Chief shall be responsible for the administration and enforcement of this Code. Under his direction the Fire Department shall enforce all ordinances of this ,jurisdiction pertaining- to : 1 . Prevention of Fires 2 . Supression of extinguishing of dangerous or hazardous fires 3 . Storage , use and handling of explosive, flammable , toxic , corrosive or other hazardous gaseous , solid and liquid materials 4. Installation and maintenance of automatic , manual and other private fire alarm systems and fire extinguishing equipment 5. ;Maintenance and regulation of fire escapes 6 . Maintenance and fire protection and elimination of fire hazards on land and in buildings , structures , and other property including those under construction 7 . Means and adequacy of each exit in the event of fire , from factory , schools , hotels , lodging houses , asylums hospitals , churches , halls , theaters , amphi-theater , and all other places in which people work , live or congregate from time to time for any purpose . -1- f OL r� 8 . Investigation of, the cause , origin and circumstances of fire. 9 . Enforcement of this Code shall not be construed for the particular benefit of any individual person or group of persons , other than the general public. In the event of a conflict between the intent of this section and any other subsection herein , this subsection shall govern insofar as applicable. SECTION III : Section 9 . 121S of the Uniform Fire Code , 1979 Edition is hereby amended to read as follows : Section 9 . 121S , The word "shall" is defined to have the following meaning : I . With respect to the functions and powers of the Director of Community Development , Chief Fire Official , any agents and employees of the City of Renton, and any Board authorized hereunder, a direction and authorization to act in the exercise of sound discretion and in good faith; and 2 . With respect to the obligations upon owners and occupants premises and their agents , mandatory requirement to act in compliance with this Code at the risk of civil and criminal liability upon failure to so act . SECTION IV: Article 78 entitled "Fire Works" and Section 77 . 105 entitled "Bond Requirements" of Article 77 entitled "Explosives and Blasting Agents" and Section 10 . 309 entitled "Automatic Sprinkler Systems" of Article 10 are herebv deleted. SECTION V : The following numbered paragraphs are to be substituted for the correspondingly numbered paragraphs of the Uniform Fire Code, 1979 Edition. I . Section 10. 208 . Premises Identification. Approved numbers or a resses as issued by the Building Department shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Said numbers shall contrast with their background, In order that numbers or addresses are plainly visible, the following size figures or letters shall be block style and used according to the schedule listed: -2- , f' 1. Residential houses - 4" 2. Multi-family living units - 12" 3 . Residential , commercial or small businesses ; 50' or less set back - 6" More than 50' set back - 5-12" 4. Large commercial or industrial areas ; 100' or less set back - 18" More than 100 ' set back - 24" Wherever practical , premises identification shall be posted on the building facing the frontage road or street or in a location approved by the Fire Chief. 2 . Section 10 . 307 Fire Alarm S stem.tem. It shall be the nolicv of the Renton Fire Department to insure the audibility of Fire Alarm Systems ; to require that in accordance with UFC "Standard" 10-2 (d) , Evacuation Signals provide minimum audibility as defined herein. Audible tones shall reach 60 db or 15 db above ambient as measured with a sound level meter , at the most remote location from signal devices , and as specified in H. F. C. Phamplet 75A. Inspection and testing is required to be performed by the Fire Department , Fire Prevention Bureau prior to occupancy being granted. In the event that an alarm system may not meet these requirements , it shall be a further requirement of this ordinance that modifications necessary to meet these minimum levels be made to the Alarm System and sub- sequent testing be conducted prior to any occupancy being granted. 3. Article 4. Permits and Certificates . Except for permits issued—in accordance with Section 11 . 101 and 11 . 113 of the Uniform Fire Code, which permits shall be non-fee permits , the fee for permits issued in accordance with Article 4 of the Uniform Fire Code shall be $ 10. 00 per year. The permits shall expire one year after date of issuance. The permit fee shall be payable at or before the time of issuance or renwal of the permit. In the event of failure to renew a permit within thirty (30) days after its renewal date , the fee for renewal of the permit shall double the amount of the above stated fee . SECTION VI : Section 2 . 303 (a) is amended by adding an additional item to the list which shall be N. F. P.A. standard 101 entitled "Code for Safety of Life from Fire and Buildings and Structures" . Additionally, line 2 of Table No . 10 . 310 "Standpipe Requirements" of Section 10. 310 entitled "Standpipes" of Article 10 entitled "General Provisions for Fire Safety" is to be amended to read: "Occupancies three stories or more, but less than 150' in height , except group R, Division 3" SECTION VII : Existing Section 7-503 of the Code of Ordinances of the City of Renton is hereby amended to read: -3- Section 7-503 , as amended : DANGEROUS FIREWORKS PROHIBITED. It shall be unlawful for any person to sell , possess , use or explode any dangerous fireworks within the City . Section 7-503 , as amended: DANGEROUS FIREWORKS PROHIBITED. It shall be unlawful for any person to sell , possess , use or explode any dangerous or illegal fireworks within the City. Dangerous or illegal fireworks shall be those fireworks so defined by WAC Chapter 212- 16 and any subsequent amendments thereto , which said Code section is hereby adopted by reference as part of this Code , three copies having been filed with the City Clerk for public inspection. SECTION VIII : Existing Section 7-516 of. the Code of Ordinances of the City of Renton is hereby amended to read as follows : Section 7-516 , as amended: PURPOSE ; COMPLIANCE WITH STATE REGULATIONS : It is the intent of this Chapter to provide a procedure for the granting of licenses and the possession, sale and discharge of fireworks- as classified by the State Fire Marshal as safe for possession, sale and discharge and not to permit the possession . sale or use of any other fireworks classified as dangerous fireworks by the State Fireworks Law, all as provided for and defined in Chapter 228 , Laws of 1961 of the State . Each licensee shall further comply with and adhere to the rules and regulations relating to fireworks as issued by the State Fire Marshal , particular reference being hereby made to that certain "Order Adopting Rules and Regulations Relating to Fireworks No. 163" as issued by the State Fire Marshal under date of June 1 , 1962 , and as such rules and regulations may be amended from time to time . SECTION IX: This Ordinance shall be effective upon its passage , approval and 30 days after its publication. SECTION X: Sections 7-901 , 7-905 and 7-910 of the Renton City Code , together with any and all other ordinances or parts of ordinances in conflict herewith are hereby repealed in their entirety. -4- PASSED BY THE CITY COUNCIL this27thdav of April - , 1981. Delores eat,CityeZT k APPROVED BY THE MAYOR this 27thday of April ,1981 . Barbara ShinDoch, Mayor Approved as to form: Lawrence J . 14rren, . Cityy_.' ttornev Date of Publication : May 1 , 1981