Loading...
HomeMy WebLinkAboutR-382013X4" F " AN';10\ MATE: AL .--�- _ - ,..,. f X/1" FX AP I�E' ', MAT•AL �, 'Ell_t _ _IIBN_' A",-TTER `_ CUgE LI\E., T. E . ;IAL A A \ :, (3! i TTER .� .r t2"Xl" Fk AN` 10\ ?•WATER AL y f,1"R AT )INP r S"�"',ISE LINE. B VATE< ALC <'1 <ET'_ IZN /4",'FT. SLI -171E 1 -• ` 1T �A`IEME\T AIN PES --)LAN(-, -STA%-:'ArdC1 'EV. AN4 JTTE? �ECTI N a-,4 � ENEHAL N: )TE 1 1 4TT. -'E P4 EMENT AS PER -L.A\ ,ft -TTE EE`SHEET r. F"O A -"NAY" CE`/EL',)l;ME\T JOINTS: JWVY JOINTS SHALL HE PLA' -ED N0T Ti, EXi,EE1 '5 1'C N LESS THAN C. THEY SHALL 140T HE LESS THAN i/16" IN THI xNESS AN.' SHALL 3E FxIEN)L 't.-3EL'.W THE E._sTTE-� LINE. , `z" THR, .,ANTS- SHALL BE PL.ACEC AT .ALL CCLD ,IDINT`- AS ^IRE vTED- 3Y ENs 1NEE < AND SHALL ERTEN 3ELOW Ci)N=':RETE. WHERE THE SIDEWALK � T01 3E PLA::E'v AGAINST THE ti[3 Ati: - zTTEK. THE `.'INT SHALL 3E A ---L' i31NT. ?,.'2'X `i" E7tP.Ah>I^t` MATERIAL :SHALL SE PLACE-- FROV = C.'S T'='.T'=, AT ALL 01, 28 RET_: i 1/9-X4" FXDANS10N R?ATERIAL SHALL 3E PLA,,^,E;, AT EVEPY F0JR7'I S11)EWALA- DANEL. THE CONCRETE M x FOR 51`',EWAL'E� SHALL-CNF:1;RV T;1 THE REE1.'IREVE\T OF :'L`I,"� ? :`4" ++STH AI ENTRAINVENT- THE E:C)!tiE;FtETE `_SHALL HAVE A ?R.',FE)N FINISH `tVITH ALL E;(;E` HAAs;., �. ,"l' T .'LEI FI`<I H. CO±PA'ION - TYPICAL )IDP,WALKS 3uRADE S_K Y ADOPTED CTT' OF RENTON ♦, 1`++ ST41 DARD PLANS - T.ST DATE: '; a ')ATE RE ISIO\ Rv AP =R 1 TYPICAL SIDEWALK COR STD DTL F007 N.T.S. 20" 48" 54" & 60" TOP SLAB 20" _ 72" TOP SLAB } 96" TOP sus N 14 BARS ® 6" CENTERS BOTTOM FACE WITH 1 " MIN. COVER NOTES: FACE OF CURB 6 1:2., •+ 617, V 11 R. i" R. :24 TOP OF 12" R. ROADWAY V-6' I CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB 6 1/T FLUSH WITH GUTTER PAN AT SIDEWALK RAMP ENTRANCE 1:12 1:24 SOP OF 1!2'R. ROADWAY 1' - 6" i DEPRESSED CURB SECTION AT SIDEWALK RAMPS PS SE 1/4, S W 1/4, SEC. O5, T. 23 N., R.OSE., W. M. KING COUNTY, WASHINGTON 6" CEMENT CONCRETE 112" R. y. •- 1" R SIDEWALK RAMP LIR LANDING VARIES FROM 6" TO 0 t 34D" PREMOLDED JOINT FILLER CEMENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANCINGS FACE OF ADJACENT CURB 612„ - SEE DEPRESSED CURB DETAIL THIS SHEET 1:24 TOP OF 1„ 17 R. ROADWAY i . r 2" . 1 • 1 DEPRESSED CURB SECTION AT fWOD£NTIAL DRt1a1EWAYS ONLY. M FOR CO IAERC'IAL DRIVEWAYS SEE STC) PLAN 104.2 FACE OF ADJACENT CURB GUTTER SURFACE FACE OF CURB .r V 1=2" R. M VR. i t TOP OF to ROADWAY v T f ' 1" R. -----� -- - CEMENT CONCRETE TRAFFIC CURB DEPRESSED CURB DETAIL AT RESIDENTIAL OR COMMERCIAL. DRIVEWAYS, AND ALLEYS GENERAL NOTES - 1. Sat standard plans 102 and 101 1 for curb expansion and contraction joint spacing. 2. Not used. 3. For Depressed Mtor4 this Driveway Cutty B Gutter Section see Standard Plain 1042 -P 101 + * PUBLIC WORKS C cum";PEEDRT E� DEPA �i T 1. PROPRIETARY CATCH BASIN HANDHOLDS AND STEPS ARE ACCEPTABLE, PROVIDED THAT THEY CONFORM TO SEC. R, ASTM C478, AASHTO M-199 AND TWEET ALL Wr-49 REQUIREMENTS. 2. CATCH BASIN STEP/HANDISOLD LEGS SHALL BE PARALLEL OR APPROXMMTELY RADML AT THE OPTION OF THE MANUFACTURER, EXCEPT THAT ALL STEPS IN ANY CATCH BASW SHALL BE SMMLAR. PENETRATION OF OUTER WALL BY A LEG IS PROHNfTED. 3. HAND40LDS AND STEPS SHALL FIVE "DROP' RUNGS AS ,/5 BARS • 6" CENTERS SHOWN ON DETAIL OR PRIOTU V?AWES TO PREVENT BOTTOM FACE WITH SIDEWAYS SLIP. 1 " MIN. COVER 16 BARS ® 7" CENTERS �r F BOTTOM FACE WITH 1 " MIN. COVER \ 1" CLEARANCE 3 REBAR #7 G4LV. (SEE NOTE 4) SaY00TH GRADE RING STEEL CATCH BASIN DETAILS IC S. Nrs KCRs z-oos 314" PREMORKATED LADDER GreWrnmerrnan. Public Works Administrate 2 CEMENT CONCRETE CURBS 5, COR STD DTL 101 N.T.S. #3 BAR EACH CORNEF #3 BAR EACH SIDE 0'2 neo cerru FI1 E AIS VANED 4WAT'E i 6" OR 12' i' ONE #3 BAR HOOP FOR 6" HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT RECTAMU1" AB.JUSTMENT SECTION P11PE ALLOWANCES POE aaMl111110111L 4. SLAB OPEMM AMY BE 24" X 20" OR 24" DIM. TYPICAL ORIENTATION FOR ACCESS AND STEPS REINFORCED OR 5. AS AN ACCEPTABLE ALTERNATNE TO RE84R, WELDED WIRE PLAIN CONCRETE REINFORCING STEEL in2/R. IN EACH DIRECTION FABRIC FMVING A RAMI. AREA OF 0.12 SOL44RE ITCHES PER 15" cam* FOOT AMY BE USED. WELDED WrR'E FABRIC SHALL COMPLY TO (STD. SPEC. 94)5.20) 8" AS7M A497. 12" MIN. 12" ANN. (STD. SPEC. 9••06.12(1)) 8" PROFILE WALL PVC 15" 6. LADDERS OR S7EPS SHALL EXTEND TO *T7h V 16" OF 60" - L 8" 48" 8" BOTTOM OF CATCH BASIN. 7 72" 6" 8" W. 12" 0.35 0.24 $4" 8" 12" 72" 12" TOP HA 40W ON STEP OR BY BOLTMIG OR EMBEDDING HANDHOLD 8" 12" 84" IN CONCRETE. EACH SHALL BE EAWDDED AT BOTTOM IN SASW STEP BASE. *ALL ALL STEPS & RUNGS 18 488- DEFORMED R 8, ADDfTIONAL SAFETY FEATURES AMY BE REQUIRED IN VERY OR COPOLYMER PROPYLENE OR . 12> ANN. DEEP OR UNUSUAL STRUCTURES. 12" MIN. \ z � N `D R=3/4" z ELEVATION PLAN 6" DROP RUNG CATCH BASIN STEP ,8 GAL V. 5" 24> 5" - DEFORWD REBAR k 16 BARS ® 7" CENTERS �r F BOTTOM FACE WITH 1 " MIN. COVER \ 1" CLEARANCE 3 REBAR #7 G4LV. (SEE NOTE 4) SaY00TH GRADE RING STEEL CATCH BASIN DETAILS IC S. Nrs KCRs z-oos 314" PREMORKATED LADDER GreWrnmerrnan. Public Works Administrate 2 CEMENT CONCRETE CURBS 5, COR STD DTL 101 N.T.S. #3 BAR EACH CORNEF #3 BAR EACH SIDE 0'2 neo cerru FI1 E AIS VANED 4WAT'E i 6" OR 12' i' ONE #3 BAR HOOP FOR 6" HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT RECTAMU1" AB.JUSTMENT SECTION P11PE ALLOWANCES POE aaMl111110111L rAi�li�1 EM REINFORCED OR 12' PLAIN CONCRETE REINFORCING STEEL in2/R. IN EACH DIRECTION ALL METAL PIPE 15" cam* 12" (STD. SPEC. 94)5.20) 8" SOLID WALL PVC 15. (STD. SPEC. 9••06.12(1)) 8" PROFILE WALL PVC 15" (STD. SPEC. 9-06.12(2)) 60" * CORRUGATED POLYETHYLENE STORM SEWER PIPE Nam 1. As acceptable alernalres io the rebor shown In the PRECAST ■AM SECTION, #foots (pieced acc P*V te the Standard SpecNraliwaas}, or wire mesh having a n** um area of 0.12 square per foal shag be used wigs the mklMmun required rebw shown in the ALTEIMiAWK PRECAST BASE SECMN. V*e mesh shall not be placed in the knockouts. 2. The knockout diameW Mud not be greater than 20. Knockouts shag have a wall thickness of 2" rnk*n xn to 2.5" rrwAmum. Pro%fte a 1.5" minimum gap between the knockout wag and the outside of the pipe. After the pipe is kn d@W, IN the gap with joint mortw in a000rdence with Standard SpedEcation 9-04.3. 3. The maximum depth from the 6ihed grade to the bwuest pipe invert shall be 6. 4. The frame and grate must be or,@ids d with tee flange down. 5. The Precast Base Sec don may howls a rounded floor, and the waft may be sloped at a rate of 1:24 or adage. 6. The opening shall be measured at the by of the precast base section. 7. AN pickup holes shag be grouted Sur a flow the bald has been placed" 8. AN grade rings and castegs shag be set in mortar to accordance vAh - \ y>r Standard Sper&MIinn 9-04.3. #3 BAR EACH CORNER 18' MIN. - >. est •., ; t'• #3 BAR HOOP - E a SEE NOTE 1 AL TEEMUTTWE !RECAST BASE SECTWIN , Pt, B1.1C WORKS CATCH NAWff TYM I 90. lr " - 900.00 DEPARTMENT MARCH 9.008 - CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00) - HANDHOLD CM --- -- RECTANGULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION tO J + GROUT, TYPICAL (SEE NOTE 5) r W. Z > FLAT SLAB TOP W, 4e", 54", ST. 72", 94" OR 91i > . <', o • e - MORTAR (TYP.) i qp r: b - _ 1 .1� STEPS sk LADDER �•\� � 'I f Q , h _ `Z REWORCING STEEL (TYP.) MORTAR FILLET + : _ GRAVEL DL FOR PIPE ZONE BEDDING SEPARATE BASE INTEGRAL BASE CAST -IN-PLACE PRECAST WITH RISER •O• RING d Y 12" GRAVEL BACKFILL FOR 6' PIPE ZOW BEDDING SEPARATE BASE PRECAST CATCH BASIN pIMN Ei10NS CATCH MAXIM BASEUM MINIMUM Mal_ 1. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate ckmr* g 3. The rectangular *am arld grate must be installed wlth the flange down. The frame may be cast Into the adustmerit section. 4. Knockouts shall have a wag Nokness of 2" rrlinMnum to 2.5" ma*num. Provide a 1.5" minkmirn gap between the knockout wag and the oubide of the pipe. Atter the po a is instated, 0 the gap with joint mortar in accordance wills Standard 9.04.3. PIPE ALLOWANCES BASIN DIAMETER WALL KNOCKOUT THICKNESS THICKNESS SI DISTANCE BETWEEN KNOCKOUTS REINFORCING STEEL in2/R. IN EACH DIRECTION SEPARATE BASE INTEGRAL BASE 48" 4" 6' 36" 8" 0.23 0.15 54" 4.5" 8" 42" 8" 0.19 0.19 60" 5" 8" 48" 8" 0.25 025 72" 6" 8" W. 12" 0.35 0.24 $4" 8" 12" 72" 12" 0.39 0.29 g6" 8" 12" 84" 12" 0.39 0.29 Mal_ 1. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate ckmr* g 3. The rectangular *am arld grate must be installed wlth the flange down. The frame may be cast Into the adustmerit section. 4. Knockouts shall have a wag Nokness of 2" rrlinMnum to 2.5" ma*num. Provide a 1.5" minkmirn gap between the knockout wag and the oubide of the pipe. Atter the po a is instated, 0 the gap with joint mortar in accordance wills Standard 9.04.3. 5. AM grade rugs, Asers, and casdngs shall be set In mortar in accordarK� me with comrgaled Polyethylem slots, Seww Pipe (Std. spec. 9w05.20) Standard Spa rilirmAinn 9-04.3. C2, (std.spec. 9-05.12(1)) 6 CATCH BASIN TYPE -2 (-W. �. 9-05.12(2)) 5 sm DTL 201.00 N.T.S 3 CATCH BASIN TYPE -1 S, COR STD DTL 200.00 N.T.S. CLEAN SURFACE AND BOTTOM AREA. PROVIDE UNr-ORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MU6T BE GROUTED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION. AOJUiT=NT iiCTI M1 SASE SECTION SEE NOTE 4 TI I I A I TTT41 NOTES 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE GROUTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO GROUT MI PLACE IN ACCORDANCE WITH At'1NA STANDARD SPECIFICATION 7-05.3. 2. SHM►AS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHINS IS PROHIBITED. 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT, 4, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Y2 BOND. 5. ADJUSTMENT SECTION SHALL BE GROUTED WATERTIGHT TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH NONSHRINK GROUT 6. GROUTING BETWEEN ADJUSTMENT SECTION SHALL BE WA I ER .FIGHT . 7. GROUT IS TO BE NOWSHRIdK TYPE GROUT MEETING THF RECAMRFMENTS OF ASTM 157 PER APWA STANDARD SPECIFICATION 9-20.3 FOR MAXIMUM PERCENT DRY SHRMIKAGF. THE MINIMUM COMPRFSSIVF STRENGTH SHAT_(. BF 4,000 PSI AT 7 DAY PER APWA STANDARD SPECIFICATION 9-20.3 8. PICK ! LIFTING HOL.FS ARI- TO BF (-n2OI.JTFD WATER TIGHT. PUBIJC WORKS I CATCH BASIN INSTALLATION STD. PLAN - 202.00 DEPARTMENT PARCH 2008 -"WATCH BASIN INSTALLATION S car srn on 202. 00 N.T.S. • 1 Know wh.r:blow. CIN Wore you dg. UTIL CONFL ICT NOT R E. CAUTION.• THE CONTRACTOR SFW_L BE RESPONSIBLE FOR VERIFYING THE LOCATION, 00EMSI(Md, AND DEPTH OF ALL EXISTING U71LIIlES WHETHER SHOWN ON THESE PLANS OR NOT, BY P07HOUNG THE U71U11ES AND SURVEYING THE HORIZONTAL AND YERTICa1L LOCATION PRIOR TO CONSTRUCTION. THIS AND THEN SHALL INCLUDE QILL.N�G UIILIR' LOCAIE A 1-�0-424-5555 POTHOLING ALL OF THE IXISTMIG UlILR1ES AT LOC4110NS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY MFkTFIER OR NOT CONFLICTS EXIST. LOCATK)NS OF SAID UTILITIES AS � SFIONN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORAN710N AND ARE SUBJECT TO VARNT10N. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SFMLL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. CITY OF RENTON APPROVED BY� DATE: APPROVED BY: �-.j DATE: I////(- 19menval" coo AMOVEDBY: DATE: P O BOX - 1478 2 2ND BIMLDMdG RENEW 1 BUN.DMrG PERANf SU*MlTAL REV. N0. DESCRApIION PIPE ALLOWANCES CATCH PIPE MATERIAL WITH MAXIMUM IMIDE DIAMETER BASIN DIAMETER ONCRETE ALL METAL Cf'S ,1; SOLID WALL PVC C2, PROFILE WALL PVC 3, 48" 24" 30" 24" 27' 30" 54" 30" 36" W. 27" 36" 60" 36" 42" W. 36" 42' 72" 42" 54" 42" 36" 48' 84" !A' ,7Q�'•" 6" 0 V712/" 54- 36- 48" 96" W. 3306" 488- 5. AM grade rugs, Asers, and casdngs shall be set In mortar in accordarK� me with comrgaled Polyethylem slots, Seww Pipe (Std. spec. 9w05.20) Standard Spa rilirmAinn 9-04.3. C2, (std.spec. 9-05.12(1)) 6 CATCH BASIN TYPE -2 (-W. �. 9-05.12(2)) 5 sm DTL 201.00 N.T.S 3 CATCH BASIN TYPE -1 S, COR STD DTL 200.00 N.T.S. CLEAN SURFACE AND BOTTOM AREA. PROVIDE UNr-ORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MU6T BE GROUTED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION. AOJUiT=NT iiCTI M1 SASE SECTION SEE NOTE 4 TI I I A I TTT41 NOTES 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE GROUTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO GROUT MI PLACE IN ACCORDANCE WITH At'1NA STANDARD SPECIFICATION 7-05.3. 2. SHM►AS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHINS IS PROHIBITED. 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT, 4, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Y2 BOND. 5. ADJUSTMENT SECTION SHALL BE GROUTED WATERTIGHT TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH NONSHRINK GROUT 6. GROUTING BETWEEN ADJUSTMENT SECTION SHALL BE WA I ER .FIGHT . 7. GROUT IS TO BE NOWSHRIdK TYPE GROUT MEETING THF RECAMRFMENTS OF ASTM 157 PER APWA STANDARD SPECIFICATION 9-20.3 FOR MAXIMUM PERCENT DRY SHRMIKAGF. THE MINIMUM COMPRFSSIVF STRENGTH SHAT_(. BF 4,000 PSI AT 7 DAY PER APWA STANDARD SPECIFICATION 9-20.3 8. PICK ! LIFTING HOL.FS ARI- TO BF (-n2OI.JTFD WATER TIGHT. PUBIJC WORKS I CATCH BASIN INSTALLATION STD. PLAN - 202.00 DEPARTMENT PARCH 2008 -"WATCH BASIN INSTALLATION S car srn on 202. 00 N.T.S. • 1 Know wh.r:blow. CIN Wore you dg. UTIL CONFL ICT NOT R E. CAUTION.• THE CONTRACTOR SFW_L BE RESPONSIBLE FOR VERIFYING THE LOCATION, 00EMSI(Md, AND DEPTH OF ALL EXISTING U71LIIlES WHETHER SHOWN ON THESE PLANS OR NOT, BY P07HOUNG THE U71U11ES AND SURVEYING THE HORIZONTAL AND YERTICa1L LOCATION PRIOR TO CONSTRUCTION. THIS AND THEN SHALL INCLUDE QILL.N�G UIILIR' LOCAIE A 1-�0-424-5555 POTHOLING ALL OF THE IXISTMIG UlILR1ES AT LOC4110NS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY MFkTFIER OR NOT CONFLICTS EXIST. LOCATK)NS OF SAID UTILITIES AS � SFIONN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORAN710N AND ARE SUBJECT TO VARNT10N. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SFMLL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. CITY OF RENTON APPROVED BY� DATE: APPROVED BY: �-.j DATE: I////(- 19menval" coo AMOVEDBY: DATE: P O BOX - 1478 2 2ND BIMLDMdG RENEW 1 BUN.DMrG PERANf SU*MlTAL REV. N0. DESCRApIION EVERETT, WA 98206 (425) 303-9363 (425) 303-9362 FAX INFO@ INSIGHTENGINEERING.NET t i 1 SfTE ADDRESS: 1300 LAKE WASHINGTON BOULEVARD N. RENTON, WA 98056 TAX ACCOUNT NO.'S: 3344500007 PERMIT NO: 015002518 I BW 08-19-201 BW 04-06-201 lIV1TULS DATE A r y J SE 1/4, SW 1/4, SES: 05, T. 23 N", R.05 E", W.M. LEGACYRENTON DWG FILENAME 130623-FM4LDWG DESIGNED BY: DATE JRC 11-04-2013 SCALE l!=20' JOB NO.: �3-123 DETAILS SHEET C5.1 t i 1 g� J I z ' D D 8 g� J I n � '