Loading...
HomeMy WebLinkAboutR-388323Match Line - See Sheet C4.01 L Match Line - See Sheet C4.02 CONSTRUCTION RECORD DRAWING In Compliance W/ City Of Renton Standards FUEL 1 FUEL F'UE� \ FUEL / /�121 F El FUEL This construction r co ��cop�-o�-0FQW W prepared byF-,CpUGHLIN PP�TERF[ F! Date: _ / I LUNDEEN and has been entitled ta- eflect field verified invert and rim elevations Approved By: of the storm, sanitary sewer and water main systems. Field verified invert and aim elevations were obtained by RYAN COMPANIES US, INC J„�„ pmed -COUGHLIN PORTER -LUNDEEN,—INC-ooes not provide any warrantee as to the 3 3 3 — PL E C g0� POWE 0' PSP&L PO ER EASEMENT, A 8602140883 accuracy or colpleteness pf su �normation provided y others. S SS SS SS SS 7 SS SS 30" SS SS SS SS = SS ti DITCH Q ; w,L ry0 S�1 RY SEWER EASEMENT, AF 6 5262 \V _ I SLOPE EASEMENT � I AE 20131121000020 i —�- _____--; I I - - —t__ J I ,I -- _- __-_-_----- _--_ _—// t00 ------------- W W I _W _ •... . W W / / — — _ _ — / W W _ woo LIMIT / �::••..: .:t. — — — — — — — _ / / W W / �' CULVERT, 12" PLASTIC _ —— IE N END 24.93 / C 7Ey ----------- --- / / S. END NOT FD ::.•.',•. `•/li�;l.. fir;::• ;.: ----------- __-----__-------- _�_ / /—� :a::;:—:.'.:^;...::�;':i;:::•:,.j s;; ::.., r•:••:: s — ------ ---- / / // O - - / :.�G.'.�:.. '..ems. 1�Y•::?/�F': :.;. --__ =J _ T — \—_ --- —� _ C TYP 1 1 \ \ ~ ------- — — SLID LID 20.78 \ \ \ -- ------ \ — W /�7th Street�— CPP W 17.80 \SI I L� I •— —— 8"CP7-�4_2� ---- mn _ ------ ---------- — —------------ ---- SD�� _ --- ----------------- 8„ �pP/W 12.55 / SD — — — — — — \ — \ I _ — SD _ _ _ — — \ \ \ \ _ —�——-------- ASPHALT So --- SD -- T. I = _----_---- — \3�R FBR \-I V g — _ V A ASPHALT _ — — V GE 18.1 \ V A A — — — — — — \ 12" CPP'\15.08 \ \ BR FBR `n FBR — —m= — — — — — _ — — —FBR R FBR 2" CPP W 14.88 CONCH r 2 \\ \� \ \ SD FBR // FBA / m/ \— — — --- — _— =_s — — - = \ \�---------�I �— SD FBR / P B, T E 1 / 7 \ �� D "FBR / CB, TYPE/1 FBR / CONC E 24 0 —_— / / — SD _� ' SDF� CB TYPE 1 �� _� CO CN �R / —/// �\ 8" C9P W 17.65 _ _ 2' \\ / APPROX S. END �' / SOyIDLt3 15.00 �,, —(NOT FD) /— �" CPP �1�4� �= P — — — —\— \ \ // SLOPE EASEMENT / / 8„ I _ �— ^— � � � LIMI \ \ AF 201 31121000020 FBR ��� f�� \ _� � LIMITi \ / — _ — I � � LIMIT �wo3�'no' PC— �r— fM LIMIT � � woo-�-0000 woo � LIMIT woo woo woo -Llwll - - LIMIT woo woo woo woo � imn �� LIMIT y� \ \ / _ woo 11WI� /C woo woo MOM 11WI� � 36798 11w14 0 I I �— > LOT B, LUA-11—049—LLA I � / TAX LOT N0. 088670-0270 Q / I I / IIII 1 II I II I / II / 4 / I I I I I 1A 3678I ---------- I IIII— I Date: Date: Date: Call before you D;g.8-I-I or 1-800-424-5555 UNDERGROUND SERVICE (USA) • 10 20 40 womm SCALE 1"=20' AWN NOTE: ALL STORM PIPE (SD) TO BE LCPE, RCP, SDR35 (IF GREATER THAN 3'). ALL STORM PIPE TO CONFORM WITH CITY OF RENTON STDS NOTE: ALL SPOTS SHOWN ARE BOTTOM OF CURB ELEV. ALL CURBS ARE TO BE 6" CURBS UNLESS OTHERWISE SPECIFIED. Legend EXISTING REMOVE PROPOSED RIGHT OF WAY PARCEL LINE ASPHALT PAVING CONCRETE PAVING BUILDINGS GRAVEL ROCKERY CURBING CONSTRUCTION LIMITS LIMIT WATER LINE W STORM DRAINAGE LINE --SD TITLE LONGACRES BUSINESS CENTER SW 27TH ST & NACHES AVE SW CONSULTANT COUGHLIN PORTER LUNDEEN 801 SECOND AVENUE - SUITE 900 SEATTLE, WA 98104 P: 206/343-0460 F: 206/343-5691 A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION ISSUED: DATE DESCRIPTION 03/09/2016 BUILDING PERMIT RESUBMITTAL 05/04/2017 NW CORNER UPDATE 07/17/2017 AS -BUILT SET KEY MAP: PROJECT NUMBER DRAWN BY ISSUE DATE SEAL QM C152268-03 SAS 05/04/2017 SANITARY SEWER LINE --SS SHEET TITLE / NUMBER POWER P P— TELEPHONE LINE T T Grading and Drainage GAS LINE G G Plan TREE IV WATER METER/FH ® t STORM CB/MH LJ SEWER MH/CO () o no • GAS VALVE/METER 9 0 b 13 C4007 STREET LIGHT o-❑ R-388323