HomeMy WebLinkAboutR-388327STRUCTURE SD#Z3 CB TYPE II - 72" RIM = 20.44 IE=14.00 24" (IN/OUT) SE,N STANDARD GALVANIZED STEEL - STEPS. SEE AUSTIN CO SPECS. ROUND SOLID COVER MARKED 'DRAIN' W/ LOCKING BOLTS 4-. PLAN OUT 8" MIN L DETAIL H N.T.S. ROUND SOLID COVER MARKED 'DRAIN' W/ LOCKING BOLTS 4" MIN 1'-6" MAX RIM=20.44 LIFT GATE CONTROL ROD a SEE DETAIL 'D' MAX W.S. IE=16.60 EL=17.10 SEE DETAIL 'C' IE=15.80 18" MIN STANDARD GALVANIZED STEEL STEPS. SEE AUSTIN CO SPECS. INLET PIPE 24" OUTLET PIPE 4 424" - IE=14.00 6" THK GROUT ALL AROUND IE=14.00 0 N LIFT GATE - SEE DETAIL 'B' d' PIPE SUPPORT 3"X.09 GAGE BOLTED OR EMBEDDED 2" IN o WALL AT MAX 3' SPACING. : �e—MH SERIES 200 MIN ONE SUPPORT `v TYPE B 72"0 RESTRICTOR PLATE WITH 6.0625"0 ORIFICE TYPE 9 MINERAL AGGREGATE 'I W/ PORTLAND CEMENT 4 MIN ��;! STRUCTURE SD#Z3 CB TYPE II - 72" RIM = 20.44 IE=14.00 24" (IN/OUT) SE,N NOTES: 1. USE A MINIMUM OF A 72" DIAMETER TYPE 2 CATCH BASIN 2. OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW 3. METAL PARTS: CORROSION RESISTANT NON -GALVANIZED PARTS PREFERRED. GALVANIZED PIPE PARTS TO HAVE ASPHALT TREATMENT 1. 4. FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE C. FRAME IS CLEAR OF CURB 5. IF METAL OUTLET PIPE CONNECT TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4" 6. PROVIDE AT LEAST ONE 3" x 0.090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL (MAXIMUM 3'-0" VERTICAL SPACING) 7. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN NTS 8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS Storm Control Structure 5 OR VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER NTS Not Used 9 NEOPRENE GASKET LIFT GATE CONTROL ROD PRESSURE RELEASE ASSEMBLY CSK 004 REMOVABLE WATER TIGHT COUPLING 12" ELBOW 6" MIN DRILLED CAP PLATE 6" MAX WITH 7.4375 0 ORIFICE DETAIL G N.T.S. REMOVABLE WATER TIGHT COUPLING 12" ELBOW 6" MIN DRILLED CAP PLATE 6" MAX WITH 7.50 0 ORIFICE DETAIL 'D' N.T.S. SEWER SADDLE SEWER SADDLE 7" MAX 3/4" DIA SMOOTH ROUND BARS EQUALLY SPACED. BARS SHALL BE WELDED TO UPPER & LOWER BANDS. UPPEP onKin LOWER BAND PLAN 24$$ ELEVATION 3/4" DIA SMOOTH ROUND BARS EQUALLY SPACED (4" O.C. MAX) 3/4" BAR A CB INNER DI 48 58" 54" 65" 60" 72" 72" 86" 96" 114" UPPER BAND 3/4" DIA BAR 1/2" PLATE DRILL HOLES -9/16" HOLES FOR LOCK )UALLY SPACED CV U") T T LOWER BAND 1 /2"�I ENTRY GATE DETAIL NOTES: 1. ALL STEEL IN PLATES, BARS AND BANDS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A36. 2. DEBRIS CAGE SHALL BE HOT -DIP GALVANIZED IN ACCORDANCE WITH ASTM A123 (AASHTO M111). NTS Bird Cage Style Debris Cage PLAN VIEW STRUCTURE SD#Z4 NTS CB TYPE II - 72" Not Used 6 HORIZONTAL CONTROL POINT HORIZONTAL CONTROL POINT HORIZONTAL CONTROL POINT ASPHALT PAVEMENT CONCRETE CURBING ASPHALT PAVEMENT ASPHALT PAVEMENT J� I I I 11 LI I =1 r it I y 1 o � H (~ U L� O z STRUCTURES W/ NO CURBING W U 24" INLET 24" TOP VIEW NOTES: 1. HED-FLEX DUCKBILL CHECK VALVE SERIES 9900 OR EQUAL HORIZONTAL CONTROL POINT CONCRETE CURBING ASPHALT PAVEMENT-1 PIP' ® i J z U O I N p U L� L� O Z W STRUCTURES ALONG CURBING Z Uj W W U Cn Approved By: Approved By: Approved By: Approved By: J N In Compliance W/ City Of Renton Standards Date: _ Date: _ Date: Date: _ SIDE VIEW NTS 'Duck Bill' Check Valve HORIZONTAL CONTROL POINT CONCRETE CURBING /-ASPHALT PAVEMENT-\ I =1Q `i o w N O U L� O Z W STRUCTURES IN CURBING CORNERS TITLE LONGACRES BUSINESS CENTER SW 27TH ST & NACHES AVE SW CONSULTANT COUGHLIN PORTER LUNDEEN 801 SECOND AVENUE - SUITE 900 SEATTLE, WA 98104 P: 206/343-0460 F: 206/343-5691 A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION ISSUED: DATE DESCRIPTION 03/09/2016 BUILDING PERMIT RESUBMITTAL 04/19/2016 CSK-004 Storm Control Riser KEY MAP: PROJECT NUMBER C152268-03 DRAWN BY SAS ISSUE DATE 05/04/2017 SEAL -ILL pET� 1� z 36936 ONAL SHEET TITLE / NUMBER Storm Drainage Details VLn NTS 4.12 Horizontal Control For Drainage Structure 12 R-388327