Loading...
HomeMy WebLinkAboutR-38832825 20 R 10 1 30 25 15 67 LF 18" SD ® 1.1 % ........................................:........................:....... 10 ................IN.146,01Y.PE III. 48" RIM=22.52 IE=14.60 12"(IN)S IE=14.10 12"(IN)E IE=14.60 12"(IN)N 5 I E=14.10 18"(0 UT) NW 30 15 ............ 5 LSD#H I CB TYPE 11.48" .............................. .................... RIM=21.36 IE=9.25 24"(IN)E IE=14.50 6"(IN)S 0 IE=9.25 24"(OUT)W 1+00 L SD#HS, C9 TYPE II - 48" RIM=21.30 IE=13.39 :18"(IN)SE IE=13.39 18"(OUT)W GRADE 2*00 1�1 .5D#H4, CB TYPE 11- 48" RIM=21.40 It=14.51 6"(IN)S : IE=12.37 18"(IN)E : 111-12.37 "18"(OUT)w 127 LF 18" SD @ 0.9% STORM PROFILE: SD#H6 t : SD#H I SCALE: I "=S' V. 1 "=20': H 3*00 74 LF 18" SD ® 0.8% SD#H3, CB TYPE 11.48" RIM=21.37 IE=11.20 18"(IN)E IE=11.20 1.8"�OUT)IN 000 102 LF 24" SD ® 0.8% SD#H2, CB TYPE II.48" RIM=21.36 .........................:....................... IE=10.57 18"(IN)E IE=14.50 6"(IN)SE IE=10.07 24"(OUT)W .:........................:....................... In Compliance W/ City Of Renton Standards Approved By: Date: Approved By: Date: ....................................................................................................................... Approved: By: Date: Approved: By: Date: 5+00 SP#H•I•, CB TYPE II -.48" RIM=21.36 IE=9.25 24"(IN)E IE=14.50 6'(IN)S: IE=9.25 24"(OUT)W .......................:...... _ AS: B LT ELEV _------- _ 4 ELF-1 .93 TOP OF LIVE STORAGE=17.00' / 1. 51 ...................:........................:........................:......................J. ..........:................ ..... :.......... ..... ......:..... .......... .......:....................... ..... .... ..................... ..................... ..................... ..................... ..................... ... ............ ..................... ..................... ..................... ..................... ............. .... ..................... ...../. .......... .................. , I I� \ BOTTOM OF LIVE STORAGE=14.00' _ .. W JUTE FABRIC BETWEEN a I� : JUTE FABRIC BETWEEN / ^ PROPOSED SEWER ,',� � \ DETENTION POND % \\ - % ELEV's :14' AND 17' IE=12.23 ' ' �' 4 a ELEVs 14 AND 77 1\ U� ' ' °° I :SEE L'SCAPE PLANS 4: \ / : / SEE L SCAPE PLANS 73.5 PIPE ,� DETENTION POND / :........................:.....................:.......................:....................:.......................:........................:......................./............:.......................:..... ........ ..................... ..................... ..................... ..................... .. ..................... .................. 117 LF 24D ®0.7% N OUTFALL T 'POND I : Lam\ / 70 LF 24" SD 0 6.9q, IE=7 00 / j / 4 4 \ /- 1 BOTTOM OF DEAD STORAGE=6.00' /: \ BOTTOM OF DEAD STORAGE=6.00' / \ _ BOTTOM OF POND=5.00 BOTTOM OF POND 5.010 B M ......... 2' FROM FACE OF CB : D Z B TYPE II 54" : 80 FOOT FUSE WELD STEEL SD#Z4, CB TYPE II - �2" RIP RAP :PAD S # S, C RIM=20.59 SEE DETAIL�� AIM-22.08 qni in wni i PIPF (al n Q% n' ri • uini 1E=8.40 24"(IN)E ........................ 1E=$,90 ..18"0N)5.W ......... IE=8.40 24"(IN)W 1E=8.40 24"(OUT)N jcr►LL: i -j T. i -Avon ........................................................................ NOTE: ALL STORM PIPE (SD) TO BE LCPE, RCP, SDR35 (IF GREATER THAN 3'). ALL STORM PIPE TO CONFORM WITH CITY OF RENTON STDS 20 iR 10 61 30 5+b 25 20 10 30 5+6 25 20 ik 10 TITLE tfLE LONGACRES BUSINESS CENTER SW 27TH ST & NACHES AVE SW CONSULTANT C O U G H LI N PORTER LUNDEEN 801 SECOND AVENUE - SUITE 900 SEATTLE, WA 98104 P: 206/343-0460 F: 206/343-5691 A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION ISSUED: DATE DESCRIPTION KEY MAP: PROJECT NUMBER C152268-03 DRAWN BY SAS ISSUE DATE 05/04/2017 SEAL PETS L ZOZ 36936 OISTE��Cy1� NAL V� SHEET TITLE / NUMBER 5 Storm Drainage Profiles 0 CONTRACTOR TO CONTACT: SPU TRANSMISSION CREW.. CHIEF. ROGER..COX..(206)..399.-.2.49.6. WITH A MINIMUM 72 HOURS NOTICE PRIOR TO BORING CONSTRUCTION. AN SPU REPRESENTATIVE SHALL BE ONSITE DURING ALL WORK WITHIN SPU PROPERTY. C4020 R-388328