Loading...
HomeMy WebLinkAboutS-388308_____ NONE NONE ______ Match Lne See SheetC501 ___________ _L Match Line See SheetC502 OIL JPELINE _ CONSTRUCTION RECORD DRAWING In Compliance W/ City Of Renton Standards MAR�ER� FUEL 121 F El FUEL This construction relcord �co y_"F�/�p f4w prepared byF-,Ck)UGHLIN PORTERF1 F1 Droved Date: _ LUNDEEN and has been entitled to reflect field verified invert and rim elevations ' of the storm, sanitary sewer and water main systems. Field verified invert and Approved By:J aim elevations were obtained by RYAN COMPANIES US, INC-in July--201. A —-COUGHLIN PORTER 1UNDEEI�INC�oes not provide any warrantee as otaie p� B B S S PO WE B 0' PSP&L PO ER EASEMENT, A�8602140883 B accuracy of CO pletene�S of„$UC �,informatlon, proVlded f�y others. E �— — �th-_-44� — — — —— prwgd 7 39.4' 30"ISS SS SS SS SS SS 30" SS SS SS SS s SS RI MH I� DITCH J I RIM 2248 — 30" RCP E-� a ���� SLOPE EASEMENT — AF 20131121000020 _ 00 II �m 10 Lr) W I W W IU W W - W zoom LIMIT ! ..:.. ••: . W Ir... W 98+50 : `;t':'•''.e NUMEN�I :-) (4) 4 COMM CONDUITS CULVER SEE PROFILE SHEET C5.21 Ir97+50 SEE DETAIL97+00 Ln Slow 96+50 96+00 — — - - - - T 95+50 _ — - - — - - - - mom 11W1� agow 95+00 - - 94+50 - - - 94+00 — - — - - - - - W 7th Street ID 15.71 SI ► Z_ 8" CPP E 12 59 8" CPP W 12.55 SD — — I -- SD SD --------- — -��— — �-- SD—SD------___------ — — —ASPHALT ------------ --rr J T'o�- I _ _ — -- — — — — — F-I V ASPHALT — — — — _3[-R FBR = — G E 18.18 — FBR 4"� 2" CPP E 15.08 FBR J _ mP FBR R FBR BR FL FBR _ ___L-_ 2" CPP W 14.88 �P FBR � CONC � 7 FBR IL �� FBR II 2 SD FBR SD mp ,7 �� SD FBR CB, TYPE 1 FBR CONC B. c�ni ID E %4 — SID SI FB� CONC FBR FBR 8" CPP W 17.65 2' �=� APPROX S. END GROUP HEALTH UV II _ � _ — — — K GROUP HEALTH UV-444 SLOPE EASEMENT (NOT FD) c, - --- � � uMl� � COMM VAULT 8 c� COMM VAULT - P � ,F 20131121000020 — FBA 000 moo � LIMIT w m � 3 � � LIMIT � � LIMIT ��w0° =� �T= � 0�no � � 11WI� LIMIT � � 11WI1 LIMIT � - -a _ _ �"""��^' � 11WI� � � � now llWll ►a� rao am11WI� momI IN-1 won am DEC. 0 I / 10" DEC. 16" DEC. / I / / II / I I / Q I II I I II I I I II I II I II II i R/C I iA 36798 I II I I I II I I II I I I II I II I II II Date: Date: Date: Call before you D;g.8-I-I or 1-800-424-5555 UNDERGROUND SERVICE (USA) womm SCALE 1"=20' AWN CONTRACTOR TO CONTACT SPU TRANSMISSION CREW CHIEF ROGER COX: (206) 399-2496 WITH A MINIMUM 72 HOURS NOTICE PRIOR TO BORING CONSTRUCTION. AN SPU REPRESENTATIVE SHALL BE ONSITE DURING ALL WORK WITHIN SPU PROPERTY. NOTE: ALL SANITARY STORM PIPE (SS) SHALL BE PVC SDR 26 OR APPROVED EQUAL WATER PLANS REVIEWED BY: ABDOUL GAFOUR 1/29/16 WATER UTILITY SUPERVISOR CITY OF RENTON (425) 430-7210 Legend EXISTING REMOVE PROPOSED RIGHT OF WAY PARCEL LINE ASPHALT PAVING CONCRETE PAVING BUILDINGS GRAVEL ROCKERY CURBING CONSTRUCTION LIMITS LIMIT WATER LINE W STORM DRAINAGE LINE --SD SANITARY SEWER LINE ---SS TITLE LONGACRES BUSINESS CENTER SW 27TH ST & NACHES AVE SW CONSULTANT COUGHLIN PORTER LUNDEEN 801 SECOND AVENUE - SUITE 900 SEATTLE, WA 98104 P: 206/343-0460 F: 206/343-5691 A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION ISSUED: DATE DESCRIPTION 03/09/2016 BUILDING PERMIT RESUBMITTAL 05/04/2017 NW CORNER UPDATE 07/17/2017 AS -BUILT SET KEY MAP: PROJECT NUMBER DRAWN BY ISSUE DATE SEAL QM POWER P p TELEPHONE LINE T T GAS LINE 0 G TREE IV WATER METER/FH ® fa t STORM CB/MH L J SEWER MH/CO � ) o OO • GAS VALVE/METER 9 0 b 13 STREET LIGHT o-❑ SHEET TITLE / NUMBER Utility Plan C152268-03 SAS 05/04/2017 C5007 S-388308 W-388308 R-388339