Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LUA-08-022 - misc
Thomas Taylor 16383 SE 48th Drive Bellevue,WA 98006 (party of record) PARTIES OF RECORD BOEING APRON D HANGAR BLDG LUA08-022,ECF Mark Clement Boeing Company PO Box 3707 #MS 1W-09 Seattle,WA 98124-2207 tel:(2060 617-2944 emh mark.d.clement@boeing.com (owner /applicant /contact) Jerry Lee 514 Burnett Avenue N Renton,WA 98057 tel:(425)204-5064 (party of record Updated:04/01/08 (Page 1 of 1) (#4713420) PROJECT AREA PROPERTY BOUNDARY GUY WIRES AND ANCHORS EASEMENT (#8601170686) N6THS "-"i .....I VICINII"PI,N ---"-----.Li'OEING I[i ® ---]RENION SIT[A,RON OI= OEVELOPMENT PLANNINGCITYOFRENTON MAR ]3 2008 RECEIVED I \ ! I DEVELOPMENT pLANNINGCi'TY OF RENTON iAR t 3 008 RECEIVED IFGFND GENERAL NOIES ?......? LL_::._::...................... --+--#,,,+,:+;:,+\_ +WEg,T L......... n_ITl,m+ +l tJQc ++ +rl.I /------------+ NORTH EL-VATIONS".,NGAR FAST WFST IiIl i •--+'I I RENTON SllIE -APRON D RFFFRFNCI"DRAWiNgS CONSTRUCTION NOTES Htis @op kr.. .....I--i-,A60 I CITY OF RENTON DEPARTMENT OF COMMUNITY &ECONOMIC DEVELOPMENT MEMORANDUM Date:June 16,2008 To:City Clerk's Office From:Stacy Tucker Subject:Land Use File Closeout Please complete the following information to facilitate project closeout and indexing by the City Clerk's Office. Project Name:Boeing Hangar D Apron Bldg LUA {file)Number:LUA-08-022,ECF Cross-References: AKA's: Project Hanager: Acceptance Date: Applicant: Owner: Contact: Apron D Hangar Building Vanessa Dolbee March 24,2008 Nark Clement,The Boeing Company The Boeing Company Same as applicant PID Number: i ERC Approval Date: ERC Appeal Date: Administrative Denial: Appeal Period Ends: Public Hearing Date: Date Appealed to HEX: By Whom: HEX Decision: Date Appealed to Council: By Whom: Council Decision: 0723059001 Narch 31,2008 April 21,2008 Date: Date: Mylar Recording Number: Project Description:The applicant Is requesting a 23,400 SQ FT'fabric-covered aircraft hanger building,on a 204.17-acre parcel,in the Urban Center North 2 zone,at 737 Logan Ave N.The hanger is being placed over existing concrete pavement.The site Is accessed by N 6th Ave.The subject parcel Is adjacent:to the Cedar River and Lake Washington.The subject location is 280 feet from the ordinary high water mark of the Cedar River and is approximately 3,900 feet from Lake Washincjton;therefore no studies were required. Location:737 Logan Avenue N Comments: Check Request for Non Vendor Refund or Reimbursement Thisform is used onl "one time vendors.Please contact A,mts Payable ifyou have any questions regarding one time vendors. 'Check will be included in the next scheduled AlP check run and mailed or released after Council approval. Check Request Info: Requestor's name: W/ooly Requestor's department/division: Payable to: Mai/addressforcheck."(,/,X,[C/)7,0 /'W5"7-{ dqT j IdA q17 7 Check amount:Account number(s)to charge:Amount per account #: s 500.O0 0,5I,g I.0o.oo I 5o0,oo Reasonfor refund or reimbursement: Checkhandlingrequest:-lr'17 ¢- *Approval Signature: Requestor's Department Administrator Division Director or designee: kJ print nanlg,dfslgneron above line Date:"Zt/.2 /0¢" Theperson approving thts check request must be an authorized signer. Q:Li3ATA C¢llieP,Forn'aLVinan=¢A2007 Check Requ=t fo¢Non Vtndor R=fiJnd or Reimbtmsemem(prlr4 d liII in)d¢P,'/m andFill/Form,Jly I007 p / Printed:05-2%2008 CITY OF RENTON 1055 S.Grady Way Renton,WA 98055 Land Use Actions RECEIPT Payment Made: Total Payment: Permit#:LUA08-022 05/27/2008 02:19 PM Receipt Number: -500.00 Payee:BOEING COMPANY ..... Current Payment Made to the Following Items: Trans Account Code Description ount ...................................................................... 5020 000.345.81.00.0017 Site Plan Approval -500.00 Payments made for this receipt Trans Method Description Amount ............................................................ PayTnent REFUND -500.00 RD Pmts Re-Dist .00 R0802711 Account Balances Trans Account Code Description Balance Due ..................................................................... 3021 303.000.00.345.85 Park Mitigation Fee 00 5006 000.345.81.00.0002 5007 000.345.81.00.0003 5008 000.345.81.00.0004 5009 000.345.81.00.0006 5010 000.345.81.00.0007 5011 000.345,81.00.0008 5012 000.345.81.00.0009 5013 000.348.81.00.0010 5014 000.345,81.00.0011 5015 000.345,81.00.0012 5016 000.345.81.00.0013 5017 000.345.81.00.0014 5018 000.345.81.00.0015 5019 000.345.81.00.0016 5020 000.345.81.00.0017 5021 000.345.81.00.0018 5022 000.345.81.00.0019 5024 000.345.81.00.0024 5036 000.345.81.00.0005 5909 000.341.60.00.0024 5941 000,341.50.00.0000 5954 650.237.00.00.0000 5955 000.05.519.90.42.1 5998 000.231.70.00.0000 Amnexation Fees Appeals/Waivers Binding Site/Short Plat Conditional Use Fees Environmental Review Prelim/Tentative Plat Final Plat PUD Grading &Filling Fees Lot Line Adjustment Mobile Home Parks Rezone Routine Vegetation Mgmt Shoreline Subst Dev Site Plan Approval Temp Use,H0bbyk,Fence Variance Fees Conditional Approval Fee Comprehensive Plan Amend Booklets/EIS/Coples Maps (Taxable) Special Deposits Postage Tax O0 oo oo O0 O0 O0 O0 O0 O0 O0 oo O0 .00 .o0 .00 .0o .o0 .oo .oo .o0 .oo .00 .00 ,00 RemaFning Balance Due:$0.00 £L-I ."•"...:'•Department of .C6mmunity d ..:' _-'l'],J '"•'i ,•....'"...'Economic Deyelopment,::-?1-Denis Law Mayor ••'>•".',''".'A el Plech,AdministratOr """ i, '"':"April 29,:2008 ,,.,. .,'":':.-•Mark Clement .,'Boeirlg Company ....".POBox3707'#MS.1.W-09r"I Seattle,W.98124-2267'..'" .'.""'."SUBJECTi..BoelngHangar D Apron:Bldt, :.....LUAUS,.UZZ,tct,... "...."Dear Mr.Clement: b ,,.-.,-. "•,>•;=',.•7 I I .,'•".,. :This letter is:'.to infonn...you thht.the appeal,period.ended .ApfiJ:,:21:,:2008.f0r.the :lnvir6nmehial'::. nimi ee (ERC)D e ighifi e-Mitigat'ed abo/"'Re/ieWCo tt 's et rmtna'tiowofNofi-S Cane .foi'[th e-"..".'.'- r&erencedproject.'.•-",,'.:.':.i "..".•":.::?.?..;"i ,:>: :'..71 '',""'"''""" •....."u 'm''-"a";&)cai°n .•.....''';....'''""'.......a:>"No appeals were.filed on the.ERC/tetenmnatton;therefore,this decision ,sfinal •for the'.appropriately i'equired permits my,proceed.The/tppheant:must.Comply.wtth,a I.ERC.'.•":'':::,•Mitigation Measures oUtlineclin.the;R.&::beisiSn:dated;'March-3l;2()08:.i :".".:,,.."".=:..:": .";.(.if you liave miy questions,,please:fdel ffe"gteldo'ntact'6 at (425)1430-31',1.,"2!;"....."")?':''':;'',";:.).i:}:!i[ ",:.,Forthe Enwmnmental Rewew Conlmttee;:....::...." •.,,.•.,.a ...,..,-..,..•-,,.•..., •-....AssocmtePlner....:,.-;......-''.--...:.....:."...-':."',..-.:'.: I '','""'Ertclosure'"'','.,i :')".....':''-•'".",""",.7 :...:..:i': •,-,,,"'.,:'.:."2 i "'",?",.. ":.-cc:"Boemg.Corporatmn./.Owner(s),.'..:.....;..".,.,",.,'..:..::......'',..::' •""•"Jerry Lee ,Thomas.Tayior/Pirty(ies)ofRei:ord,':,i ..-:".'i "."•".'"".-.:-" ""'.'""::"-'"'"""2 "'.'5."...•'........""i••)•••:••i i •::,,•-i0; So arad R a0g;W i ::on 9s0i7 :N ENTO'N ,::::•..,.y,y".g .,".,......,,...,,=.,......':......,",":•'"......":"',•","•"""'",,'•"":.'.AHKD OF'THE'CURVE.",1 STATE OF WASHINGTON,COUNTY OF KING } AFFIDAVIT OF PUBLICATION PUBLIC NOTICE Linda M Mills,being first duly sworn on oath that she is the Legal Advertising Representative of the Renton Reporter a bi-weekly newspaper,which newspaper is a legal newspaper of general circulation and is now and has been for more than six months prior to the date of publication hereinafter referred to,published in the English language continuously as a bi-weekly newspaper in King County,Washington.The Renton Reporter has been approved as a Legal Newspaper by order of the Superior Court Of the State of Washington for King County.The notice in the exact form annexed was published in regular issues of the Renton Reporter (and not in supplement form)which wasregularlydistributedtoitssubscribersduringthebelowstatedperiod. The annexed notice,a: Public Notice was published on April 5,2008. The full amount of the fee charged for said foregoing publication is the sum of $117.50. Legal Advertising Representative,Renton ReporterSubscribedandsworntomethis7thdayofApril,20118. lathy Dals$f/q[ary Public fqlrthe"State of Washington,Residing in Covingto[,Washington P.O.Number: NOTICE OFENVIRONMENTAL DETERMINATION ENVIRONMENTAL REVIEW COMMITTEE RFdCI'ON,WASHINGTON The Environmental Review Commillee has issued a Determination of Non- Significanee-Mitigmed for the following IffJecl under the amhory of the RemmM,p coae.Boeing Hanger D Apron BldgLUA084/22,ECF Lolioa:737 LoganAven.e N Renton. WA 98055.The applic,l is requesting a 23,400 sq.ft.fabric-covered airmail bengerImilthng,ona 204.17-acre parcel in the Urban Ceraes N0lh 2 zone.at 737 Logan Ave N.The City of Renton and The Boeing Co.entered into a devclopmem agreemmt that vested this site to land use regulations for ongoing Renton Plant aperanons and potential redeveltmnenl,as such this pject will be reviewed under Heavy lnduslfial (IH)zoning from 2002.The hanger is being plm:ed over existing concrete pavemea Tbe site is accessed by N 6th Av The subject parcel is adjacem to the Cedar River nnd Lake Wshington. The subject location is 280 feel from the ordJmrd high water maA of the Cedar River and is approximately 3,900 feet from Lake Wxhington;therefore no studies were required. Appealsoftheenvimnmemal determination must be filed in writing on or before 5:00 PM on April 21.2008.Appeals must be filed in writlng together with the required $75.00 application fee with:Heating Examiner,City of Renton.1055 Soath Gredy Way,Rento,WA 98057.Appeals to the Examiner are governed by City of Rertton Municipal Code Section4-8-1 HI.B. Additionalinformationregardingthe appeal pmces.s may be obtained from the Remon CityClerk's Office,(425)4305 !0. Published in the Renton Reporteron April 5,2008.#64297. NOTCE" ENVIRONMENTAL DETERMINATION ISSUANCE OF A DETERMINATION OF NON-SIGNIFiCANCE -MITIGATED (DNS-M) POSTED TO NOTIFY INTERESTED PERSONS OF AN ENVIRONMENTAL ACTION PROJECT HAMI:Boeing HIngerO Apron Building'PROJECT NUMBER:LUA0S.O22.ECF LOCATION:737 Logl*fl Aveng|N DEgCRLpTION:The appgclnt It rKluMtlng •3,400 iq.t,febd=.Cover=d iIr¢nlt hinglt building,on |204,IT-acre perCel,In th•Urbln Cont=l North 2 son•at 737 Lollen Ave N,The City of Ronton Ind The Boeing CO,entered Into •devil•pro|or Igmmonl thl*tvt=d I111•=tie to tend un rlguLsstions for ongoing Renton Plant operllJonl ifld potlnBel redevllopTirn isluck thIt pfoig[wltl be mvilwld und=l Hl•vy Lndul*tdll (IH)zoningfrom2002,Tt hi*tiger le bllflg placid over ozilqtng coi'¢rltep|verneflt.Tile lit=leat€tuned by N ath Ave,Thnsubjectpllcnliseecl*nt to the CtXl=r RIv •nd Lake Welhingt.The =ubNct (ccltlafl [11 210 fRI from tile ordinary highwl*terml*rk of Iho CaVil Rlvl*r end epproxtmeilly 3.100 flit tom LakJ Wuhlllgton;thePlf=ilfo |tudle|w=m required, THE CITY OF RENTON ENVIRONMENTAL REVIEW COMMLTTEEERC)HAS DETERMINED THATTHEPROPOSEDACTIONDOESNOTHAVEASIGNIFICANTADVERSEIMPACTONTHE ENVIRONMENT. Appeate of the environmental det|rmlnl*ilon must be llled InwrttJng on ol b=lar,i IhD0 PM onApdJ L 2001L Appeals* m'nLt be*fll|d In writing togoth wh the llqultl $?6,110 l*ppllcl*tlon fee wllh:HdnU Ex=ndMr,City of RJntonq 1055 South Orady WBV,Renton,WAgllO7.Appeal=IO the Examlr am governed hy City of Re*nighMunlclpl*l COde $ecllon 4.8,110B,Addlllon=i Infnrmetion regarding ¢h==ppe|l pine=||m=y be ottalfled from till*R|ntan City Cll*rk*=Office,(4[6)430..0S1O. IF TIlE ENVIRONMENTAL DETERMINATION IS APPEALED,A PUBLIC HEARING WILL BE SET AND ALL PARTIES NOTiFiED, FOR FURTHER INFORMATION,pLEASECONTACT THE CITY OF RENTON,DEPARTMENT OFCOMMUNITY&ECONOMIC DEVELOPMENT AT (4425 430-7200, DO NOT REMOVE THIS NOTICE WITHOUT PROPER AUTHOR ZATION II CERTIFICATION I,P.v.O"-'..,,V(X%,hereby certify that copies of the above documl,],,,i ` were posted by me in-cofispicuous places or nearby the described propertya_.LYNN [t. ENVIRONMENTAL DETERMINATION ISSUANCE OF A DETERMINATION OF NON-SIGNIFICANCE -MITIGATED (DNS-M) POSTED TO NOTIFY INTERESTED PERSONS OF AN ENVIRONMENTAL ACTION PROJECT NAME:Boeing Hangar D Apron BuildingPROJECTNUMBER:LUA58-022,ECF LOCATION:737 Logan Avenue N DESCRIPTION:The applicant is requesting a 23,400 sq.ft.fabrlc-coverad aircraft hanger building,on a 204.17-acre parcel,in the Urban Center North 2 zone,at 737 Logan Ave N.The City of Rcnton and The Boeing Co.entered Into a development agreement that vested this site to land use regulations for ongoing Renton Plant operations and potential redevelopment,as such this project will be reviewed under Heavy Industrial (IH)zoning from 2002.The hanger Is being placed over existing concrete pavement.The site Is accessed by N 6th Ave,The subject parcel Is adjacent to the Cedar River and Lake Washington.The subject location is 280 feet from the ordinary high water mark of the Cedar River and is approximately 3,500 feet from Lake Washington;therefore no studios were required. THE CITY OF RENTON ENVIRONMENTAL REVIEW COMMITTEE (ERC)HAS DETERMINED THATTHEPROPOSEDACTIONDOESNOTHAVEASIGNIFICANTADVERSEIMPACTONTHE ENVIRONMENT. Appeals of the environmental dotormlnafion must be filed In writing on or bofora 8:00 PM on April 21,2008.Appeals must be filed in writing together with the required $75.00 application foe with:Hearing Examiner,City of Renton, 1055 South Grady Way,Renton,WA 08057.Appeals to the Examiner are governed by City of Ronton Municipal Code Section 4-8-110,B,Additional information regarding the appeal process may be obtained from the Renton City Clerk's Office,(425)430-8510, IF THE ENVIRONMENTAL DETERMINATION IS APPEALED,A PUBLIC HEARING WILL BE SET AND ALL PARTIES NOTIFIED, SITE FOR FURTHER INFORMATION,PLEASE CONTACT THE CITY OF RENTON,DEPARTMENT OF COMMUNITY &ECONOMIC DEVELOPMENT AT (425)430-7200. DO NOT REMOVE THIS NOTICE WITHOUT PROPER AUTHORIZATION ..r :.'pla.ilrlclqde the.projec t NUMBERwhen ca!!lng for p.roper flle,ident!flcatiOd,....i. ""i i CITY )V.,RENTON.:..J, ."I.{JILI-I..,|.i'.....'.".•DepartmentofCommunity"and`".."k_--'l'b]f]"."EconomicDeyel0p.ment "'.,'.'). •i ..", •April.'3'2008 ....- iii ''rkClement i i I .."•.•i ..•'.,I ..'.. ':i .f ",Bo6ing Comp/my ,.. -:POBox3707"#MSlW-09 "''.... •'.""-seattle,,.WA.98124-2207' ,,..r ,I ....i .'SUBJECT:'.Boeing Hangar D:Apron-Bldg LUA08:022,ECF '.;...i!.. .,'. i )• .•.'..I .i • ..•L i ?.i .i .., :i .;•,..I•k5 Dear Mr.Clement':"'"":'....:"""' •.?.7-:'--,..--.Wl¢le":er.i"wrih'n-,'""'......'.......'"'"°"'"'"'on,behalf of,the.Environmental Review.Committee (ERC)to advme'you :,v,.-,," :'.'".'tim[the).h'ave::c0mpleted t!}e r."tgvlew.,.iof the subject proje&and'have .lssued.:a iflfi-ehold"_''"7 ,.':,:., .,:.i .Detenninfition.of .N0n-Significihce-;Mitigated.with MfiigatiomMeasures.''Please'refer :!0 the..':".i;.:i ,:,.if.,7":'.encl0sed ERC Repotand Deci?.b0}:phrt:2 Section B fora !istof.theMifigati0n.Measur.es.':.:?.."::":./: :,.).:":""'""'',,",;:":.....",":.'.......i'.'>:'"'" ¢[,g r ''Appeals of)(he':ehvironmentai:de]efhilntl6ff:mins t be filed:in:wrlting:off;0rbefore5i001;PM ::?::: '....,'.on April 21,2008;.Appeals•must;be.filed.m..wntmg together watl the.requwed.$75.00..:,-...... •:':',applicati0n.(ee with::Hearing gxafifinr,::Cit;ofRenton .:1055 SauittGrady Way Renton wAI ..-::,.,:,:: :?:•'i:.98057..Appeals;toih'd:Eainr are:go ,emed!b)),?City of Rentdfi Mnieipa]COde"s,etipfi-,4-8-.;:;'!)[ ..i-:110 B Additibha information rdgarding.t ie.appe/:procesd may.be obtained:fl'bm,the:Rfitofi,::;":;:."...': ?i ".<'..:".';:ff theEnvii'onmntal Dergnningtign::is,appealed,a:'publi6 hgafifig .date wi[!,be:t and,.all.:partieS.::..,.¢-:.. '/.",..(':/::".hbfified 'Th&prcediiig :iiffdrnia'ti&i .will•figsist you in:.plarming.".for'implemeniiitiSn..of..'y0ur 7 :.'-:i:.:. ."::.'.'project int.:enihl6.y;u,to:exercise yo6i-alSfieal£ghtsmel:e fuiiy,:if you .chbos .td d0.so:.If,you,.,":.:'.,..i".:.:,.i '::.-'have any ciuestions ordesire clar[fieaii6fi:o'the"alt)4e,pleffse efill meiat:(425)i:30-73:f4.:..:-::..i":...:':)Y'"" I (I I iiI IIii :iIIIIIiiI:Ii IIII:I,i I III:ii i:i /iI•L"%.'-For theEnvronmentalRevLew.Commttee .-:'::.•..,:.".',..'::,...; •'.¢,.:':".''"""""'........:.'''.'i."""2,-.-•..."".,..:'v';i :.::.'i,,".".i """.," "'".Ass ,,rq ,,,,,"'"-.......,,•oc:a'e aaaea/...."......-'":""""''':' .".7,:",Eiielosure'"'''-"'""'''"'...."...........,.":.,"....'",':: ,,.,?'.,,"","..,."......:'.',:.'.:....,':,.i '.?",);.••"• '""'"2"i'v'""'•"'''""'.......',cc:Thomas Ta'ylor,Je_..Lee'/Party(les)ofRecord ...;......',.... ..,I •,::.".:.•I ..,-.,:.:-....•.t i ",:i:).::'1;;5:SoU"0iii h;;iii:')W ashingt'dn 98;57.'F t'": :.......;"''_.Thlllpapersr:O%'reeW.lmaltcil,30%potoonsumer':'"'i i ".•";'•'"..i ".'%.' .m •'•,',.,r •"April 3,2008 Wlfington.State -. •...POBox47703 Departmen.t of Eco ogy,,. ,Envir6nrriental'Review SeCtion..":'.:"....:. •,•.• •,,,. ••,,, '••••€,TY F RENTON•••••:•:i•• ....'.,'...":-"""",'Deiartmnt.of.C0mmunity,and '"''".?.....:...EonomieDevelopment ".'.'"''"....'Alex Pletsch Admililstrator .••...i lOlympiaWA98504-7703 "., i :subjeetL ••.,,'i.• •Envli'onmental Dd:ermlnati0n,'....,". .•Transrmtted herewith.is a copy of.theEnv,ronmental Detennmatl0n.for the following pro.leer revtewed by..,-" ',".theEnyir0rimentaiReviewCornttee(ERC)tiMarchi31,2008:.."','-("".,"'.'"(.i...,". ":=,,"',."..D ON S ,'.'.L,"'"'"',:ETERMINATI OF NON-IGNIFICANCE-MITIGATED .'.-....'•..•.. •-','-'....-'',::'"','L •..,i:......7.'•:'''''"" '"""'.'PRoJECTIA :-..Bo g ltn D Api'0n Bidg .""": ...,,.'PIOJECTNUMBER::'LUA08-022,"EcF./'""......•':":,'i ,'".,.::'.":."."': •...LOCATION:....'-737.Jogau.AvelnleN .."...:i .":..'.i'•'.:."".-"'"". :''',i"..'.DESCR1P'TIONi ".,":'.Tlieapplleantjs request ng a.2'3,00.sq',:ft'fabric-eovei'eii'tiircr*ift,hanger ....i - ,.-,•'..:-",."building;oh a204.L7.acre:lareel;In,ih6'.Urban Cent6r-N6rtii2,zon .ai237"Eogan,A,e.'N'TiieCib'..,".'':: -'..''0fRenton and TheB6dng Coi'eniefed!fl.6.a develoPmeii¢agieein.etit:0mtvest6d/(lis's[telti lifid.lhse '...(,.'"/ '-.,:."'..,regulailons for"bng0ingRenton.Phhit,opei'atl0ns:and'pbt6ntliil redevei0pment,:as"sult:tliisprliject"'...,.i.'::,•...•""will,he,reyiewed'amlgv:iieav)i'nduii'iai:(lll)zohing frbm 2602:Tlie:ha'hgeris:deihd'liaced 0ver:,.",•"'':,' .:'•:','":exitin6re6acrete.liavehent;Tlli:slti,'lsi'a'q'essed,be.,N'6t!l xye;,The,stbjeetpareelisadjaccnt to:tli6•::;.,:-,:L . /,:;'",.:,:Cedar,Rlver,andLaKeWdsliligtoii;.tThe:stibjeei:lhi:ation lsr'280 f6etffr;om,th'ei0i'dlnai'y hlgli.w(ter •:.',::.."';:''.':'":mark of tliiCedat"River andls apb'i't;iimatdiy?3;900:feet•from Lake Waslilagt0n;ther6fhr'e::n0.,:',,".' '.-'-'studies:were required.:.."...''.?i'.;",'",;:?:'/;..:'.•.,?.7.'-.".,.:•.:'."?"-'...:'':".;","' •...:-.,.....,.,...;.,.,..,....x.,..•.,-.,-,...•..."-.,Appeals Oi'-tlie'envlronmental determination must be filedm writing on or hefg.re'5;00 eM.on.APrtl .'.....",.'. :..':,.21"i,..2008...Ap6iils.must.be.led.i.writihg.6g6tier.wiih.thereqired!$75:i.appliatiii.f6.with:,';.'-",¢. -...Hearing Exam0er,:Cly of:Renton,.[055.South"G'ady,Way,.Ren!on,.WA98057.'.Appeal.s to.,the:...i .:.'. •".::...!:(regardirfg the:alSpeil •Prbces6:may be obia'ind.f(6'rh the Rehfon City Cle?k'.,.offic/",(-:);5 4306516::":,.i ,.:, lfyollhave.qucsti0hspleasccallmeat(25)430i'1314:i'71.i.;i'..."::.<..i.!.:.//i..'..:..i .i-" ",",.•'For:theEnvr0nmental Rewew,Cbmrmttee,....,,."..,.:,,.'•:."•.:'....:,:'..'. .,:v,,".":,.....'"".i,'".''':.....:"':,"' -:""Associate Planner ,................--:-.."'-'''''" •'"'"'":"i"'i ...'.'".',.:.:';'..:?Enclosure .....'.-'":::.'.":i'.i."'.:i:.7 '•..":.."",-.'"ce:'i King.Count,.Wastwater Treaifnent Division-":."'.'.""-'FW,'Siewart"Reinbol ""....."""''.:,:.....:.....wo d".::......?,''.....,:....-.'""""David F,Dietzman Department:ofNatural R6sofirces.•,•,'...,..•... ':?..•....I'WSDOT N0rthwest'Region':..'."""'.....".....".-.....;..... ,,,,..•,,,,,.,Karen'Walter,Fsherlesl Muckleshoot Indmn:TrdSe....•,.:•,'"i','."".'.""..-,"".....D'.r'-;'...x,A -£x,.,,,,. ,•...........,.....,........:......,.,,[,t.,l,,......,...•'.................................0"7 '"'••--',-N TO N:•....,:.iu3,outnraoywayrKellon .wflsnalgtoa tt 3 .-.:......-,..."-....'.,.. -","".",!...".:(,Thlspaperconml50*mo#mntedal,30ptcoum:'-,•"."3"..'•;,."','.,......,..:"::.'."' .".. ..,i" ,..,• p 'APPLIcATIoN NO(S): ,,.",APPLICANT: •PROJECT NAME:.,' DESCRIPI:ION'OF PROPOSAL:.. •DETERMINATION OF NON-SIGNIFICANCE-MITIGATED . ..'."MITIGATiONMEASURES ' C!TYOFRENTON :.."i..,".:.'...ii'.i.::''"".: ,"i i"J' ,"h. .LUA08-022,'ECF B0e ng Company,Mark Clement BoeingHanger D Apron Bldg.:"'" •',,." Theapplicant 234q-;00"s-""""":",is.requesti'ng:a ft::fabric-cOyered aircraft hanger .: •building.on a 204.17-acre parcel,in the Urban CenterNorth 2 zone,at.737 LoganAve N."The City.ofRenton and., .The'Boeing (o,entered :into a development agreementthat vate(:i.this:sitetoland use.regulations fof;ong0ing " Renton Plant operations and po[ential 'edevelopment,.as such this project Will be re{,i6wed underlHeavy Industrial"(IH)'.zon!ilg fi:om,20o21 The harlgeris being placed over exist ng cbndrete,pavementl The SI{is.accessed by N " •",.'.6th Ave,..The subject parcel is adjacent:to the Cedar River and LakeWashington-:.!The subje'¢t Iocation'is 280' '....feet from theordinary high water mark of the Cedar River.and isapproximately 3,9001feet from I:.fike Washington ' "'therefore no:stud es were requ red .....,.-"":"..:"" LU(,.;AHUNUI-HRL)HUAL:.'737 Loga.n AvenueN_'-.,.....,••'.'•-,.,,,,.,•.", ..,.The City,of Renton '.;,.:"-•,••,•.i :LEADAGENCYi """"'''....'"'' :"':"!"."";.:"_.i":'...,'''"',"'",,:PlannlngDivlslonDe'partmet',.....of Commun,:.....:iY&",;,.Econom,c Deve.:,........opment....,'"....:.....:;,..'..,.'.": 'MITIGATION I&AAIIB ,,,,,•.,,.,,.•,•,*,.,,,,, ....1,The apphcant,shallpay theoppropnat°.re:MibgationFee$0.52 pergross square feet.of building area...".... ",-Ths.fee s'tobepadprortosecurngtheu noPermtsfforthsDroJect:,..--,.--:-,'........ •,...,...•.....•,.;......',z *,,.,-,.....-,.....•,.•....,......, •.........'............--...i ".,".')ii.::.::•-::,,"i ::....".,..-...:..'•"•,":,,i ......:i!i.. 2 ''.i,.., ...,• .,r ..t 'i"'EROMiig"dn'Measures':'"""""'"'""'"'"""""'"';':":'::.,.".:'...''.'Page'lof,l'".',. •.,. 'CITY.OF RENTON DETERMINATIONOF NON-SIGNIFICANCE-MII"IGATED ADVISORY NOTES. AP#LICATION N0(S): APPLICANT:.• .PROJECT NAME:." LUA08-022,ECF Boeing Company,Mark Clement Boeing Hanger D Apron Bldg •.-.',..DESCRIPTIONOF PRoPo'SAL:•The applicant is requesting a 23,400 sq.ft.fateri-covered aircraft hanger ....":.:building,ona 204.17-acreparce ,n the Urban:Center North 2 zone,at 737 Logan Ave N.The.Cit/of Renton and •.The.Boeing Co entered iintc a development agreement that vested .this site to landuse regulations.for ongoing.'"Renton Plantolerations and poteniial redevel0pment,.assuch this project will be're,iewed under Heavy Industrial •"',...'(IH)'oning from:2002.The hangr is being placed over existing Concrete pavement•The site is accessed by N •6th Ave.Th'e.subject parcel is adjacentt0 the Cedir River and,Lake Washington•The subjectlocation is 280..":"'"":'.feet from the ordinary high water mark.of the Cedai"Rivei"and is approximately 3,900 feet from !..akelwashington;.' '':therefore nos!udles,were required.'... '":""'LOCATI'ON.OF PROPOSAL::''737 LoganA,enue N •"..•..•'•LEADAGENCY:"-,""••,...i_.•.,The City 0flRenton ".:.....'..".Dep'amerit of Commueity &'EconOmic Development '.'. '';"'..Planning'DivJslon ""•.......•....'". .....:.,•'.Advisory Notesto Applicant:,."'-"........-•The following notes are supplemental Infermatlon;proildedJn conjunction with the environmental determination;. .'.Becausethese notes are provided,as Information onlyithey are,not subject to the appeal process for.-.." •..'.....,:...!:.,'•.;.,........,... •1.RMC sect=on4-4030.C.2 hm=ts haul hoursbetween8:3Oam to'3:30,Pm.Monday through Fnday unless •.i •".otherw=se approved by•the Development,Services Dws=on.The Development:Services Dwson reserves."......, ,""the right tores'cind the.approved eterdd,'hBul-hours ai any tirne if Cc)'mpiaints,arereceived..''".'"... •.,=2:..Wthm thirty (30)-days of Completion of,gr,ading,worl<,the,applicant shall hydroseed or planLanapproprlate •'.,.... "'.ground cbve.r 0,er"anY,iorti0nlof tllasiitatii,]raedocieared of:,egetation a0d.where no..further '.',.:!.'': ....'constructionw0ik will occur•within.ninety (90),clay.'Alternative measures:such asmulch sodding Or;.".::,.,' "."plastic covering as Sp'ecified n:the current King:Countysurface Wa'ter,Management Design Manual as ,::.,,,, ..•..,adopted by the Cty of Renton may be proposed between the dates of.November.lst and March31st bf ;,....-..! .i .each year•The..Development Services Division!s appro,al of th swork is.required prior.t0finallinspectibo .. ".and approval ofth"permit..-•'".'"..........•..",,""" .•3.Construction acti,itiesshall:be restiicted to ihehouis between'seven 0 ci0ck(7:00)a.m:,ahd.eight:o'cJocl<:.:' •;..(8:00)p.m.,Monday ihi'oUgb =F.,riday,.:W0rk.gn,saturdays Shalt be.restrictedlt0 the hours:betweennine '..-'.". ::.":-;.i ,.O;clo.ck.(9:00)a:rri;and"eight o.clock (8:Q0)ip:m;N0.workl.shall.be permitted dn Sundays ..;:.::."",'.:.!.,-.:'. '.•:"Fire Department:'.:":"',..',.',..•:,, •.'1','he preliminary fire.flow is 2;50O'gpm.:iOne hydrant isrequired within t 504eat:of:the structure and,,0 -'"", ,-'.":."additional hydrantsaie:requ redwtl n300-feetofthe S'tructure,".-..,•"."'-.:: ,...2.Separate plans and permitsare:require for the.inst'allati0n of fire.sprinklerland'sprinkler.rnonitring'";'. •',systems•.."••.'."":,"".i.:;".i ''.'."i..'.'"",.'"'"..""' "3..-Prov de a list 0fthe flammab e €ombustb e:liquids-and any hazai-dous:chemicals to be Usedor Stored on "'" ',pl ""installati0 d/ofallflammable:liquid.st0ragetank s :'•.site.separate ansand permits.for,nan or modification '".both ab0veground and undergrourd:"'".".,.......... "•.":.:'oi•";ERC AdvisoP/,Notes.:,.-.i';i Pageil;2....,'' '.Pian Review'• Water J 1.Preliminary fire flow required by the fire de artment is 2.500gpm:Two hydrants are required to serve th!s .'' site•One hyd(ant.sha be W th n 150 feetand one additional shall be within 300 feet,6f thºe structure. 2.Existing hydrants approved"to.bacounted.as fire.protectionshall be retrofitte(l With:aquick.disconnect . ..St0rz;fitting if no{already installed.Note on plan if/equired.Show 10catiohs ofali'existing hydiants..• ,.,.,•...*.".• Sanitary Sewer "'•,.",t .,.•,,....,•,",,Jl•! .c 1.'If the building department requires:,floor,drairls,drainS.shall beconnected tO the srita,sewer s,ystem.".i. .'Flowsshall be directed through floordrains :that are installed in accordance with.the un!form Plumbing. ..•',CQde.toan interior,or:extet:ior,oil/water Separ/itori The)sepai'ator.shallbe:siZedt0 rfieeta,minimum 15-.'...-minute retention time for.peak.flo/os anticipatedin the garagg'.area,but in no case.wil!.be.!ess:than:200 ...i :.. gallons of storage capacity.The:type of !nterCePtor shall be as.manufactured by.P.ipe.lnc...Utility Vault:•; ..,..":•.•,":..,Inc.,,or approved equa S.z ng.calculations,will .berequired',,"''''i': .,.•..;,,:-.,, # SurvaceWater .;..L ,.,.......:"'•".,.. ..••.a •,,,,,.,,,••.,,,*.1.',.Erosion control shalbcomplY.wth Dearlment:ofEcology smost current StormwatersManagement:Manual..., •"'"'",0!,t,""'i:".......'';•.:.,;""'..".." ".''•'.',""."t ¢''",''..",-'".""="L '."-::."'': •..*,.,...,..%.,,,,•.,%-.,., •,,,..•.,,..,.,.,..:,- ••.,•1,,••..,",.•..••..%•,,,•i •g.. ,,,.••. ",.•%• ""'".'.'"'"':•''"'.7:'.,,,,.,,*e •. i -,.,'.."'"...".".".'..'".• .'"'..;'":.,.,''.,,,..:',,...:>',-'.;..-:..-,, ERC AdvisoryNotes :,•.. .•,%,.,q=..,, ".":'i ..:::,'',:..; .,.2-,.,,":.•.i -*•..•..,.,,•.,. •..,"'-,..,;..,,Page2of2 ,:. ....,"'',i ':U CITY OF RENTON DETERMINATION OF NON-SIGNIFICANCE (MITIGATED) APPLICATION NO(S):LUA08-022,ECF APPLICANT:Mark Clement,Boeing Co. PROJECT NAME:Boeing Hangar D Apron Bldg DESCRIPTION OF PROPOSAL:The applicant is requesting a 23,400 sq.ft.fabric-covered aircraft hanger building,on a 204.17-acre parcel,in the Urban Center North 2 zone,at 737 Logan Ave N.The City of Renton and The Boeing Co.entered into a development agreement that,vested this site to land use regulations for ongoing Renton Plant operations and potential redevelopment,as such this project will be reviewed under Heavy Industrial (HI)zoning from 2002.The hanger is being placed over existing concrete pavement.The site is accessed by N 6th Ave.The subject parcel is adjacent to the Cedar River and Lake Washington.The subject location is 280 feet from the ordinary high water mark of the Cedar River and is approximately 3,900 feet from Lake Washington; therefore no studies were required. LOCATION OF PROPOSAL:737 Logan Avenue N LEAD AGENCY:The City of Renton Department of Community &Economic Development Planning Division The City of Renton Environmental Review Committee has determined that it does not have a probable significant adverse impact on the environment.An Environmental Impact Statement (EIS)is not required under RCW 43.21C.030(2)(c). Conditions were imposed as mitigation measures by the Environmental Review Committee under their authority of Section 4-6-6 Renton Municipal Code.These conditions are necessary to mitigate environmental impacts identified during the environmental review process. Appeals of the environmental determination must be filed in writing on or before 5:00 PM on April 21,2008. Appeals must be filed in writing together with the required $75.00 application fee with:Hearing Examiner,City of Renton, 1055 South Grady Way,Renton,WA 98057.Appeals to the Examiner are governed by City of Renton Municipal Code Section 4-8-110.B.Additional information regarding the appeal process may be obtained from the Renton City Clerk's Office,(425)430-6510. PUBLICATION DATE:April 5,2008 DATE OF DECISION:March 31,2008 SIGNATURES: r gg Zimrrterrr n,AdministratorPublicWorks JjgeaipDarelnS Fire Chief ,lePietsch,Aa)ninistrator Department of Community & Economic Development Date Date Terry Higashiyama,Administrator Community Services Date ......,•.ENVIRONMENTAL REVIEWCOMMITTEE,,=ii.','/i.,i;'i:"!:.'=''"'-::.-MEETING NOTICE ,J •,,i , To:Gregg Zimmerman,Public Works Administrator Terry Higashiyama,Community Services Administrator I.David Daniels,Fire Chief Alex Pietsch,CED Administrator From:Jennifer Henning,CED Planning Manager ....';....Mar h3i 2008 .........'''Meeting DateL Monday,c ,'".....,:.,."Time:3!00 PM' Locat on..Sixth Floor Conference Room #620 Agenda listed below. Ram Short Plat (Tlmmons) CC: LUA07-140,SHPL-H,ECF Application for Environmental Review for a 6-lot short plat In the R-8 zone.This project is also subject to short plat review by the Hearing Examiner.The underlying parcel Is 44,503 SF and proposed density would be 7.48 dulacre. The existing single-family home would be demolished.Street Improvements would be required along Queen Ave.N. and NE 6th St.and 0,581 SF would be dedicated for public right-of-way.There are 29 significant trees onaite,of which the applicant proposes to retain none.There are no critical areas onsite. Key Plaza -Renton Hiahlands (Wasser) LUA08-013,SA-A,ECF The applicant is requesting Administrative Site Plan Review and Environmental (SEPA)Review for a proposed commercial development in the Commercial Arterial (CA)Zone.The proposed project consists of two commercial buildings with a combined floor area of 17,187 square feet on a 1.4 acre site.Seventy parking stalls are proposed to accommodate the proposed commercial uses. Taylor Lot Line Adlustment (CONSENT ITEM)(Tlmmons) LUA08-016,LLA,ECF The applicant is requesting a Lot Line Adjustment to adjust the lot lines for three parcels on a 0.51 acre site into two lots and Environmental (SEPA)Review for the future development of two single-family homes.The subject property Is zoned Residential-8 (R-8),and Is located in the 400 block of Talyor Place NW Just south of NW 5th street.The current parcel size is 25,620 square feet and contains 2,545 square feet of critical areas on-site Including a Class 4 stream and protected slopes.The project proposes to average the stream buffer on site to a minimum width of 25 feet. BoeinR HanRar D Apron Bldfi (CONSENT ITEM}(Dolbee) LUA08-022,ECF The applicant is requesting a 23,400 aq.ft.fabric-covered aircraft hanger building,on a 204.17-acre parcel,in the Urban Center North 2 zone,at 737 Logan Ave N.The City of Renton and The Boeing Co.entered into a development agreement that vested this site to land use regulations for ongoing Renton Plant operations and potential redevelopment,as such this project will be reviewed under Heavy Industrial (HI)zoning from 2002.The hanger Is being placed over existing concrete pavement.The site is accessed by N 6th Ave.The subject parcel is adjacent to the Cedar River and Lake Washington.The subject location Is 200 feet from the ordinary high water mark of the Cedar River and Is approximately 3,000 feet from Lake Washington;therefore no studies were required. D.Law,MayorJ.Covington,Chief Administrative OfficerS.Dale Estey,CED Director ®D,Pargas,Assistant Fire MarshallN,Watts,Development Services Director ® F.Kaufman,Hearing ExaminerC.Duff'/,Deputy Chief/Fire Marshal ®J.Medzeglan,CouncilP.Hahn,Transportation Systems DirectorR.Lind,CED Planning ManagerL.Warren,CityAttorney ® ERC REPORT City of Renton Department of Community and Economic Development ENVIRONMENTAL REVIEW COMMITTEE REPORT ERCMEET1NGDATE:March 31,2008 Project Name:Boeing Hanger D Apron BIdg Owuer:Boeing Corporation 737 Logan Avenue N Renton,WA 98055 Applicant Mark Clement 737 Logan Avenue N Renton,WA 98055 File Number:LUA08-022,ECF Project Manager."Vanessa Dolbee,Associate Planner Project Summary:The applicant is requesting a 23,400 sq.ft.fabric-covered aircraft hanger building, on a 204.17-acre parcel,in the Urban Center North 2 zone,at 737 Logan Ave N. The City of Renton and The Boeing Co.entered into a developrnent agreement that vested this site to land use regulations for ongoing Renton Plant operations and potential redevelopment,as such tbis project will be reviewed under Heavy industrial (IH)zoning from 2002.The banger is being placed over existing concrete pavement.The site is accessed by N 6tb Ave.The subject parcel is adjacent to the Cedar River and Lake Washington.Tbe subject location is 280 feet from the ordinary high water mark of the Cedar River and is approximately 3,900 feet from Lake Washington;therefore no studies were required. Project Location:737 Logan Avenue N Renton,WA 98055 Exist.Bldg.Area SF:N/A Proposed New Bldg.Area (footprinO:23,400 SQ FF Proposed New Bldg.Area (gross);23,400 SQ l:q" Site Area:204.17 -acres Total Building Area GSF:N/A STAFF Staff Recommends that the Environmental Review Committee issue a RECOMMENDATION:Determination of Non-Significance -Mitigated (DNS-M). Project Location Map ERC REPORT 08-022.doc City ofRenton Department ofCorer Planning Division Report ofMarcb 31,2008 &Economic Development En mental Review Committee ReportBOEINGBozlNGHANGERDAPRONBLDG LUA08-022,ECF Page 2 of4 PART ONE:PROJECT DESCRIPTION /BACKGROUND Tbe applicant is requesting a 23,400 sq.ft.fabric-covered aircraft banger building in the Urban Center North 2 zone,at 737 Logan Ave.N.The site is located south ofN 6th Street and west of Logan Ave.N.The City of Renton and The Boeing Co.entered into a development agreement ("2002 agreement")on June 28,2002,by Resolution No.3568 which,among other things,established baseline trip counts,redevelopment credit and vesting of land use regulations under certain circumstances for ongoing Renton Plant operations and potential redevelopment,as such this project will be reviewed under Heavy Industrial (IH)zoning from 2002 (Exhibit 1). Pursuant to the Renton Municipal Code in effect in 2002,Site Plan Review applied to all development in the zones listed under 4-9-200B.I which did noVinclude the IH zone.Therefore,the subject proposal doses not require Site Pian Review.However,environmental review under SEPA is required since the proposedprojeet exceeds 4,000 sq.ft. Historically,this site has been used for aircraft manufacturing and is the location of the Boeing Corporation airplane manufacturing plant.The surrounding uses of the proposed location is primarily aircraft manufacturing; west of the site is The Renton Municipal Airport and the Cedar River Trail,directly south is the Renton Stadium and east is the Boeing fire department building 2 and a parking field (Exhibit 2). Tbe existing space D-9 of Apron D would be the approximate site for the proposed airplane hanger.Apron D currently consists of 100%impervious surfaces and will continue to be impervious at project completion.As proposed the airplane banger would be placed over this existing concrete pavement and there would be no significant grading and no significant filling required for its construction.No additional runoff would be created by the project therefore,the existing onsite storm water control system would be sufficient for runoffcollection. Apron D consists of 10 spaces tbr 737 aircrafts.After the construction of the proposed airplane hanger,Apron D would consist of 7 spaces for 737 aircrafts and one covered airplane hanger,equaling a total of 8 spaces. The Comprehensive Land Use designation is Urban Center-North and the zoning is Urban Center-North 2. Although,due to the above mentioned development agreement tbis particular site is vested to 2002 zoning and therefore,for purposes of this review this site is zoned Heavy Industrial.Ttle site is accessed byN 6th Ave.,an existing access used by Boeing.The hangar would be composed of steel framework with a fabric covering to witbstand exposure to flight line activity.Tbe hangar would include one fixed end wall and one end wall with roll-up aircraft door.The highest finished heigbt would be +/-55 feet (Exhibit 3).Tile primary purpose for the banger would be for day one installation activities related to preflight preparation of the 737.The secondary use would be for repair and refit activities that require dry conditions,along with backup location for polish requirements.The 737 aircraft would be primarily un-fueled however,a provision would b e made to accommodate a fueled aircraft,fueling operations would not occur inside thedlanger.Lighting would be required appropriate for aircraft inspection. The subject parcel is adjacent to the Cedar River and Lake Washington.Tile subject location is 280 feet from the ordinary high water mark of the Cedar River and is approximately 3,900 feet from Lake Washington.As identified by the 1995 FEMA maps there is a 100 year flood plan hazard area near the subject site and on the subject parcel.Pursuant to tile site plan provided,the proposed hanger is outside of this flood zone (Exhibit 4). I[PART TWO:ENVIRONMENTAL REVIEW In compliance with RCW 43.21 C.240,the following environmental (SEPA)review addresses only those project impacts that are not adequately addressed under existing development standards and environmental regulations. A.Environmental Threshold Recommendation Based on analysis of probable impacts from the proposal,staff recommends that the Responsible Officials: Issue a DNS-M with a 14-day Appeal Period, ERC REPORT 08-022.doc City ofRenton Department ofComm Planning Division Report'of March 31,2008 ,&Economic Development Env ental Review Committee ReportBOEINGBC,,,NG IIANGER D APRONBLDG LUA08-022,ECF Page 3 of 4 B*Mitigation Measures I.The applicant shall pay the appropriate Fire Mitigation Fee $0.52 per gross square feet ofbuilding area.This fee is to be paid prior to securing the Building Permits for this project. CQ Exhibits Exhibit 1 Zoning Map 2002 Exhibit 2 Vicinity Plan Exhibit 3 Elevations Exbibit 4 Site Plan D.Environmental Impacts The Proposal was circulated and reviewed by various City Departments and Divisions to determine whether the applicant has adequately identi[ied and addressed environmental impacts anticipated to occur in conjunction with the proposed development.Staffreviewers have identified that the proposal is likely to have thefollowing probable impacts: !.Fire&Police Impacts:The proposed development will result in an overall increase of square footage of commercial development within the site.This increase is anticipated to create a need for additional fire protection services. Mitigation Measures:The applicant shall pay the appropriate Fire Mitigation Fee $0.52 per gross square feet ofbuilding area.This fee is to be paid prior to securing the Building Permits for this project. Nexus:SEPA,Fire Mitigation Fee Resolution No.2913,Ordinance 4527. E.Comments of ReviewingDepartments The proposal has been circulated to City Department and Division Reviewers.Where applicable,their comments have been incorporated into the text of this report and/or "Advisory Notes to Applicant." €"Copies of all Review Comments are contained in the Official File and may be attached to this report, Environmental Determination Appeal Process:Appeals of the environmental determination must be filed in writing on or before 5:00 PM,April 21,2008. Renton Municipal Code Section 4-8-110.B governs appeals to the Hearing Examiner.Appeals must be filed in writing at the City Clerk's office along with a $75.00 application li:e.Additional intbrmation regarding the appeal process may be obtained from the City Clerk's Office,Renton City Hall -7th Floor,1055 S.Grady Way, Renton WA 98057. ADVISORY NOTES TO APPLICANT The following notes are supplemental information provided in eonjnnetion with the administrative land use action.Because these notes are pro4ded as information only,they are not subject to the appealprocess for the land use actions. 1.RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pro,Monday through Friday unless otherwise approved by the Development Services Division.The Development Services Division reserves the right to rescind the approved extended haul hours at any time if complaints are received. 2.Within thirty (30)-days of completion of grading work,the applicant shall hydroseed or plant an appropriate ground cover over any portion ofthe site that is graded or cleared of vegetation and where no further construction work will occur within ninety (90)-da:cs,Alternative measures sucb as mulch,sodding,or ERC REPORT OS-O22.doc City ofRenton Department ofCorer, Planning Division Report of March 31,2008 &Economic Development En mental Review Committee Report BOEINGBotffNG HANGER D APRON BLDG LUA08-022,ECF Page 4 of4 . plastic covering as specified in the current King County Surface Water Management Design Manual as adopted by the City of Renton may be proposed between the dates of November 1 st and March 31 st of each year.The Development Services Division's approval of this work is required prior to final inspection and approval of the permit. Construction activities shall be restricted to the hours between seven o'clock (7:00)a.m.and eight o'clock (8:00)p.m.,Monday through Friday.Work on Saturdays shall be restricted lo the hours between nine o'clock (9:00)a.m.and eight o'clock (8:00)p.m.No work shall be permitted on Sundays Fire Department: I.The preliminary fire flow is 2,500 gpm.One hydrant is required within 150-feet of the structure and two additional hydrants are required within 300-feet of the structure. 2.Separate plans and permits are required for the installation of fire sprinkler and sprinkler monitoring systems. 3.Provide a list of the flammable,combustible liquids and any hazardous chemicals to be used or stored on site.Separate plans and permits for installation and/or modification of all flammable liquid storage tanks both aboveground and underground. Plan Review: WATER I.Preliminary fire flow required by the fire department is 2,500 gpm.Two hydrants are required to serve this site.One hydrant shall be within 150 feet and one additional shall be within 300 feet of the structure. 2.Existing hydrants approved to be counted as fire protection shall be retrofitted with a quick disconnect Storz fitting if not already installed.Note on plan if required.Show locations of all existing hydrants. SANITARY SEWER I.If the building department requires floor drains,drains shall be connected to the sanitary sewer system. Flows shall be directed through floor drains that are installed in accordance with the Uniform Plumbing Code to an interior or exterior oil/water separator.The separator shall be sized to meet a minimum 15- minute retention time for peak flows anticipated in the garage area,but in no case will be less than 200 gallons of storage capacity.The type of interceptor shall be as manufactured by Pipe Inc.,Utility Vault Inc., or approved equal.Sizing calculations will be required. SURFACE WATER I.Erosion control shall comply with Department of Ecology's most current Stormwater Management Manual. ERC REPORT 08-022.doc mX Co | D J i J \\\ \ IM(P) IH // IH oo Z \ I IH(P) ZONING vmm sc.mc swcu 6th St. IH IH N IL(P) F3.18 TZ3N Rb'E E 1/Z ....Itenton ty LtmitJ I,SQQ 7 TZ3N RSE E 1/Z53O7 i C CaI-4-I- X U.l -7 LEGEND •i G £OH jm.=m REFERENCE DRAWINGS CONSTRUCTION NOTES CO u=J -Id ELATIONSHANGAR j .mmu ?:,¢ EAST WES I RF.NTON -APRON D DEVELOPMENT pLANNINGC,q"Y OF RENTON I/,AR 1 3 ZBB@ REC A601 F 'v= q im Q -i"XIu ICity,of Rffon Department of Community &Economic Dm,,opment ENVIRONMENTAL &DEVELOPMENT APPLICATION REVIEW "'('-COMMENTS DUE:MARCH 28,2008REVIEWINGDEPARTMENT: IF APPLICATION NO:LUAO8-022 ECF DATE CIRCULATED:MARCH 24,2008 APPLICANT:Boein9 Co. PROJECT TITLE:Boeing Hangar D Apron Bid9 SITE AREA:25,000 square feet LOCATION:737 Loqan Avenue N SHEET PLANNER:Vanessa Dolbee PLAN REVIEWER:Jan Illian EXISTING BLDG AREA (qrossl:N/A PROPOSED BLDG AREA (qross /23,400 square feet WORK ORDER NO:77878 SUMMARY OF PROPOSAL:The applicant is requesting a 23,400 sq.ft.fabric-covered aircraft hanger building,on a 204.17-acreparcel,in the Urban Center North 2 zone,at 737 Logan Ave N.The hanger is being placed over existing concrete pavement.The siteisaccessedbyN6thAve,The subject parcel is ad acent to the Cedar River and Lake Washington,The subject location is 280 feetfromtheordinaryhighwatermarkoftheCedarRiverandIsapproximately3,900 feet from Lake Washington;therefore no studies were required. A.ENVIRONMENTAL IMPACT(e.g.Non.CodE I COMMENTS Element of the Probabts Probable MoreEttvironmontMillerMajorInformationimpactsimpactsNecessary E,3nI Air Water Pleats Land/Shoreline Use Animals Environmental Health Energy/ Natuml Resources Element of the Probable Probable MoreEnvironmanlMinorMajorhrtormationImpactsImpactsNecessary Housing Aesthetics Light/Glare Recreation Utilities Transportation Public Services Historic/Cultural Preservation Airport Environment lO,O00 Feel14,000 Feet B.POLICY.RELATED C C MMENTS We hsfreev wad this applieetioFIwfpanicu/er attention to those areas In which we,,,,-,o,. Siil'n atu'D're ct °i/''t''-Re Presentative have expertise and have identified areas of probable impact or Date/7 NOTICE OF APPLICATION A Master Application has bean flied and accepted with the Department of.Community &Economic Development (CED)-Planning Division of the City of Renton.The following brieflY'describes the application and thenecessaryPublicApprovals. PROJECT NAMEJNUMBER'.Boeing Hangar D Apron Bldg /LUA08-822,ECF PROJECT DEBCRIPTION:The applicant is requesting a 23,480 SO FT fabric-covered aircraft hanger building,on a 204,17-acre parcel,In the Urban Center North 2 zone,at 737 Logan Ave N.The hanger is being placed over existing concrete pavement.The site is accessed by N 6th Ave.The subject parcel is adjacent to the Cedar River and Lake Washington.The subject tocation is 280 feet from the ordinary high water mark of the Cedar River and is approximately 3,900 feet from Lake Washington;therefore no studies were required. PROJECT LOCATION:737 Logan Avenue N PUBLIC APPROVALS:Environmental (SEPA)Determination APPLICANTIPROJECT CONTACT PERSON:Mark Clement,Boeing Carp,;Tel:(206)617-2944; Emi:mark.d,clament@boeing.com If you would like to be made a party of record to receive further information on this proposed project,complete this form and return to:City of Renten,CED,Planning Division,1855 South Grady Way,Renton,WA 98057. File Name /No.:Boeing HangaqD Apron Bldg /LUA08-822,ECF NAME:.18 ..,MAILING ADDRESS:5"I L"',.'Ii''"T"T'" TELEPHONENO.:"/,.;'--_.(z ,/---:") DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT MEMORANDUM DATE: TO: FROM: SUBJECT: March 25,2008 Vanessa Dolbee,Planner Jan lllian,Plan Reviewer Utility and Transportation Comments for Boeing Hanger "D" LUA08-022 737 -Logan Ave North I have completed the review for the above-referenced development proposal. EXISTING CONDITIONS WATER There is an existing 8-inch looped private water main onsite. SEWER There is a City sewer main to the west of the site. STORM There are existing storm drainage facilities onsite. CODE REQUIREMENTS WATER ,Preliminary fire flow required by the fire department is 2,500 gpm.Two hydrants are required to serve this site.One hydrant shall be within 150 feet and one additional shall be within 300 feet of the structure. ,Existing hydrants approved to be counted as fire protection shall be retrofitted with a quick disconnect Storz fitting if not already installed.Note on plan if required.Show locations of all existing hydrants. SANITARY SEWER .If the building department requires floor drains,drains shall be connected to the sanitary sewer system.Flows shall be directed through floor drains that are installed in accordance with the Uniform Plumbing Code to an interior or exterior oil/water separator.The separator shall be sized to meet a minimum 15-minute retentiontime for peak flows anticipated in the garage area,but in no case will be less than 200 gallons of storage capacity.The type of interceptor shall be as manufactured by Pipe Inc.,Utility Vault Inc.,or approved equal.Sizing calculations will be required. SURFACE WATER 1.Erosion control shall Management Manual. co:Kayren Kittrick comply with Department of Ecology's most current Stormwater City of R=,.,on Department of Community &Economic De,opment ENVIRONMENTAL &DEVELOPMENT APP:LICATION REVIEW REVIEWING DEPARTMENT:f'/t,t/l'(0,,(,,,.COMMENTS DUE'.MARCH 28,2008 APPLICATION NO:LUA08-022,ECF DATE CIRCULATED:MARCH 24,2008 APPLICANT:BoeinQ Co. PROJECT TITLE:Boeing Hangar D Apron Bldg SITE AREA:25,000 square feet LOCATION:737 Logan Avenue N SHEET PLANNER:Vanessa Dolbee RECEIVED PLAN REVIEWER:Jan Illian ,.,MnlulAl ,.').I;28 EXISTING BLDG AREA (gross):N/A BUILDING DIVISIONPROPOSEDBLDGAREA(gross)23,400 squareTee[ WORK ORDER NO:77878 SUMMARY OF PROPOSAL:The applicant is requesting a 23,400 sq.ft.fabric-covered aircraft hanger building,on a 204.17-acre parcel,in the Urban Center North 2 zone,at 737 Logan Ave N.The hanger is being placed over existing concrete pavement.The site is accessed by N 6th Ave.The subject parcel is adjacent to the Cedar River and Lake Washington.The subject location is 280 feet from the ordinary high water mark of the Cedar River and is approximately 3,900 feet from Lake Washington;therefore no studies were required. A.ENVIRONMENTAL IMPACT (e..Non-CodE Element of the ProbableEnv/ronmon!Minor Impacts Earth Air Water Plants Land/Shoreline Use Animals Environmental Healtl) Energy/NatumlResources )COMMENTS Probabte MoreMajorInformation Impacts Necessary Element of the Probable Probable More Environment Minor Major Information Impacts Impacts Necessary Housin[t Aesthetics Lt,ht/Glare Recrestion Utilities Transporta#on Pubfic Services Historic/Cultural Preservation Airpo Environment 10,000 Feet 14,000 Feet B.POLICY.RELATED COMMENTS C.CODE-RELATED COMMENTS We have reviewed this applicah-pa,iculer attntionto ose ereas'in"wich we have expertise and have identified areas of probable impact or areas where additi/informati=on nded 'o proper assess thisproposal. Sig,,a,ure oo r or A'htz'ed Rep'resentativeC'"/'Da,e // CITY OF RENTON FIRE PREVENTION BUREAU MEMORANDUM DATE: TO: FROM: SUBJECT: March 25,2008 Vanessa Dolbee,Associate Planner Corey Thomas,Plans Review Inspector Boeing Hanger D Apron Building MITIGATION ITEMS; 1.Fire mitigation fees are $0.52 per square foot of new proposedbuilding;23,400 square would be $12,168. FIRE CODE REQUIREMENTS: 1.The preliminary fire flow is 2,500 gprn.One hydrant is required within 150-feet of the structure and two additional hydrants are required within 300-feet of the structure. 2.Separate plans and permits are required for the installation of fire sprinkler and sprinkler monitoring systems. 3.Provide a list of the flammable,combustible liquids and any hazardous chemicals to be used or stored on site.Separate plans and permits for installation and/or modifications of all flammable liquid storage tanks both aboveground and underground. City of R,..,on Department of Community &Economic De.Jpment ENVIRONMENTAL &.DEVELOPMENT APPLICATION REVIEW SHEET REV,EW,NGDEPARTMENT:Fie APPLICATION NO:LUA08-022,ECF APPLICANT:Boein,q Co. PROJECT TITLE:Boein9 Han,qar D Apron Bid9 SITE AREA:25,000 square feet LOCATION:737 Logan Avenue N COMMENTS DUE:MARCH 28,2008 DATE CIRCULATED:MARCH 24,2008 PLANNER:Vanassa Dolbee PLAN REVIEWER:Jan Illian EXISTING BLDG AREA (gross):N/A PROPOSED BLDG AREA (gross}23,400 square feet WORK ORDER NO:77878 SUMMARY OF PROPOSAL:The applicant is requesting a 23,400 sq.ft.fabric-covered aircraft hanger building,on a 204.17-acre parcel,in the Urban Center North 2 zone,at 737 Logan Ave N.The hanger is being placed over existing concrete pavement.The site is accessed by N 6th Ave,The subject parcel is adjacent to the Cedar River and Lake Washington.The subject location is 280 feet from the ordinary high water mark of the Cedar River and is approximately 3,900 feet from Lake Washington:therefore no studies were required. A.ENVIRONMENTAL IMPACT (e.g.Non.Code Element orthe Environment Earth Air Wato[ Plants Land/Shoreline Use Animals Environmental Health Energy/ Natural Resources Probable Minor Impacts Probable Major Impacts COMMENTS MoreInformationNecessary Elementofthe Probable Probable MoreEnvironmentMinorMajorInformation Impacts Impacts Necessary Housing Aesthetics LihYG/are Recreation Utilities Transportation Public Soelces Historic/Cultural Preservation Airport Environment tO,O00 Feet 14,000 Feet B.POLICY.RELATED COMMENTS //P',)£ C.CODE.RELATED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where additional [nformah'on is needed to properly assess this proposal,}I Signature of Director or Authorized Representative Date ® NOTICE OF APPLICATION A Miitlr Apic&tlon hu blen Ehld |rid leeeptea with thl Department of Communfiy &Economic Development(CED)-Plinnln2 Elyhililn oil thl Cityel Rinton.Thl lallolnp bdif dlid bll thlllppll©lllClninathlnilllilllrypublicApploVllll+ pROJECTNAME/NUMbER:8ollg Hllngar D Alcim Bd 2 /LUAO022,ECF pROJECTDESCRIPTION:Tr applmant •riquelbng a 23AQ0 SQ F]tibrcovlrid nlrmll harlerbulatl,tm•204 17-aerl pirCll,in IPi urm CIr*WNOllh 2 zeM,at 737 Laiiin Ave N The eanger i bei ¢d==eaovereinge.anerele pevllmllnI The ire iI ulmd by N lh AVe The |uel pimel llaiIrw=nl to me Cidlr RerendLaklWalhlngtonTeIlbli:t clllon i 260 feet Ec thl ¢inary high wler msrk of Ihe Cidlr RlVll ana nppmxmatly 3102 fiel train Lake Weihlngton;emfore no|d/i wire tlulnld. pROJECT LOCATION 737 Logan Avialue N pUBLIC APPROVALS:Envonmintal (SEPA)Ditermmlmn APPLICANT/PROJECT CONTAGT PERSON:Mark Clemenl,Boeing Corp ;T:12061817-2944;Eml m|rk d¢timintObo n9 corn Ccqmlinll on thl ilbovl ippll¢|ttorl rnullt bl lilbmltllll In wrllln0 to Vinoln Dillbl,Ailocllte plliml IDeplmenlelComm.nli#&B©onomlil DIvelopmlnt,t06S 8oiah Orldy Wiy,Rinton,W&|0017,by J:00 PM on MIrnh I|.100&If yl have qu|lonl |gout pmpoll,el wtih I be miiae epar f re¢nnd aal,nal noll=lan b mBII,nlal frill proiect MIm|gor al (425)430-7314 Anyone who lubinilll iwllilln omroe willaotumallealbleorneaayelrecordBna411blnoUldofenydl¢on thl|lecc PLEASE INCLUDE THE PROJECT NUMBER WHEN CALLFNG FOR PROPER FILEIDENTIFICATION | DATE OF APPLICATION:March 13,2000 NOT[CE OF COMPLETE APPLICATION;March 24,2208 Ifyou wod [kl tobe a paey mcoPato mcidvlflrlhlrknfllnian oil th pmpoud preel,cornplli rollformendrlilurnto:Cy Of RInton,CEE,Plannln2o 11Q 8ulh Oiody Wa,Renton,WA 1807r Fe Nlmll /NO.:BOelg HanglilDApte 8i /LUAO022,ECF NAME: MJLING ADDRESS:, TELEPHONENO; CERTIFICATION I,7'-rl ,hereby certify that copies of the above document •,.,•:,AVwerepostedbymem:consp cuous places or nearby the described property 9m,.,. ATTEST:Subscribed and sworn before me,a Notary Public in and for the State ofWashington residing in,. ..../'NOTARYpUBLICSIGNADRE::.: CITY OF RENTON DEPARTMENT OF COMMUNTY &ECONOMIC DEVELOPMENT -PLANNING DIVISION AFFIDAVIT OF SERVICE BY MAILING On the 24th day of March,2008,I deposited in the mails of the United States,a sealed envelope containing Acceptance Letter and NOA documents.This information was sent to: Name Mark Clement -Boeing Co. Surrounding Property Owners Representln Owner/Appricant]Contact See Attached (Signature of Sender)." STATE OF WASHINGTON ) )SS COUNTY OF KING ) I certify that I know or have satisfactory evidence that Stacy Tucker signed this instrument and acknowledged it to be his/her/their free and voluntary act for the uses and purposes mentioned in the instrument.. Dated://D_ My appointment expires:o-l -IO Project Name: Project Number: Notary Public in and the State:lLhi.'w _LJNotary(Print):#"¢t"Z.q/.lf3 /o'--/,Yt .,'."'-,, 111',,- Boeing Hangar D Apron Bldg LUA08-022,ECF 088660005005 BOEING COMPANY THE PROPERTY TAX DEPT PO BOX 3707 M/C 20-00 SEAI-I'LE WA 98124 722450034003 BROI-FEN LANNEI-rE C 524 BURNEI-I"AVE N RENTON WA 98055 722550010002 CRECELIUS LEWIS 428 BURNEI-I"N RENTON WA98055 722450036008 CU"I-FING LARRY D 16919 150TH AVE SE RENTON WA98058 072305908500 FACILITIES &OPERATIONS CTR OFFICE OF THE EXECUTIVE DIR 300 SW 7TH ST RENTON WA98055 072305909805 FEDERAL RECOVERY OF WA PO BOX 1435 TACOMA WA 98401 722450031504 JEFF'S AUTO REPAIR INC 21701 HIGHWAY 99 #A LYNNWOOD WA98036 722450035505 LEE JERRY W 514 BURNEITAVE N RENTON WA 98055 722550009509 MEAD ROBERT C 432 BURNE1-FAVE N RENTON WA 98055 722550011000 MOORE RUTH REUTIMANN 7025 116TH AVE SE NEWCASTLE WA 98056 722550008501 MUELLER VICTOR 442 BURNETTAVE N RENTON WA 98055 722450035000 MUNAGLIA DOMINIC A &TERR M 518 BURNE'I-FAVE N RENTON WA 98055 722450034508 PEDEFERRI ANDRE H 14702 NE 65TH ST REDMOND WA 98052 722550007503 TAYLOR THOMAS L+DORIS S 16383 SE 48TH DR BELLEVUE WA 98006 722450036503 THOMPSON HEATHER 702 N 5TH ST RENTON WA 98055 722550009004 TRAN PHUOC+THI NUOI FANG TU 438 BURNE1-FAVE N RENTON WA98057 722450032502 VIDELL VICTOR E+LANCE M 536 BURNEI-rAVE N RENTON WA 98055 722550011505 ZURCHER ELIZABETH C+PHILIP 420 BURNETTAVE N RENTON WA 98055 NOTICE OF APPLICATION A Master Application has boon filed and accepted with the Department of Community &Economic Development (CED)-Planning Division of the CRy of Renton.The following briefly describes the application and the necessary Public Approvals. PROJECT NAME/NUMBER;Boeing Hangar D Apron Bldg /LUA08-022,ECF PROJECT DESCRIPTION:The applicant is requesting a 23,400 SQ FT fabric-covered aircraft hanger building,on a 204.17-acre parcel,in the Urban Center North 2 zone,at 737 Logan Ave N,The hanger is being placedoverexistingconcretepavement.The site is accessed by N 6th Ave.The subject parcel is adjacent to the Cedar RiverandLakeWashington.The subject location is 280 feet from the ordinary high water mark of the Cedar River and is approximately 3,900 feet from Lake Washington;therefore no studies were required. PROJECT LOCATION:737 Logan Avenue N PUBLIC APPROVALS:Environmental (SEPA)Determination APPLICANT/PROJECT CONTACT PERSON:Mark Clement,Eoeing Corp,;Tel:(206)617-2944; Eml:mark,d,clement@boeing.com Comments on the above application must be submitted In writing to Vanesse Dolbee,Associate Planner, Department of Community &Economic Development,1050 South Grady Way,Rsnton,WA 98067,by 5:00 PM on March 28,2008.If you have questions about this proposal,or wish to be made a party of record and receive additionalnotificationbymall,contact the Project Manager at (425)430-7314.Anyone who submits written comments will automatically become a party of record and will be notified of any decision on this project, I PLEASE INCLUDE THE PROJECT NUMBER WHEN CALLING FOR PROPER FILE IDENTIFICATION I DATE OF APPLICATION:March 13,2008 NOTICE OF COMPLETE APPLICATION:March 24,2008 DATE OF NOTICE OF APPLICATION:March 28,2008 If you would dike to be made a party of record to receive further information on this proposed project,complete this form and return to:City of Renton,CED,Planning Division,1055 South Grady Way,Renton,WA 98057, File Name /No,:Boeing Hangar D Apron Bldg /LUA08-022,ECF NAME: MAILING ADDRESS: TELEPHONE NO,: 'i/i/,:?,7 ,::f.:,,'....,...:......:.-........CIT$:)F ,RENTON ...,. ,:(,:.i :L";':...'''i :.:Department0f.€0mmtmityand ' i i t--"-iiZ]'":""""<':-;'"'....37'.'-:"...'Econ0mlc Development ,"1.<7/De,isi;,i,,,),ivi,,yor:-.:,".":::":":L ":'".""AlexPletsch7 Adminlitrt0r ...("?,' cha2008 '::"......" :"""i"')"71 i:"•'" >i Ma/'kClifinerit :'.'.".-.:", ':',,".:''i''..';='i 7 .".'',.":"• ,'PO.,Box307,#MS'IW-09 "..'"i =,.Saite WA98i24 ',.:.'.......',2207 -':'""-- .'..-':Sulii¢i.,t:.'!i Bo'elng.Hit ai;DApr0nBlilg.''':: ,7 ;.I:LUA08-022,:ECFiI'.:i.i''";. •Dear,M/'.Clement:';.:L 'r :,"!2 ,.::.''.... •::ThePlannmg Section of the C ty of,Rentonhas'determmed'tliat the.subject apphcatlon,s :.- .....:•,V '•....complete according to submittal requirements and,,therefore,is accepted forre lew,..,,, .01;""i it is:tentatiJeiy:scleduiedfor c0nsidei.atibnlb¢ihle,EnvironmeiitalRevle:w.c;fiamittee on.,':2 .March 31:2008 iirior tothil revi;Vo'?will/b,ngifiedifahv//dd ti&al nforma/ibnis,"-,"'' ......"Variessal;%ibee,:7 .:.:".,"7 ,:.,::..,:::.::.,:i ., %.....•.<•.+,:.,..,..•,,,.,.,.: ,........*.;.,,;;.-.,,,.,, ::':::,:0;,sX;aG,.,,/:,>:w,y :i RE: •".:.......':'....AHEAD;OIL THE CUIIV]'"''""liThls portals:0%--mala"l,3=%'Da41tcoflum"pa con n rcy I na 0 8r ,I City of Renton of oLANDUSEPERMIT MASTER APPLICATION PROPERTY OWNER(S) NAME:Boeing Corp. ADDRESS:737 Logan Ave n. CITY:Renton ziP:98055 TELEPHONE NUMBER:(206 617-2944) APPLICANT (If other than owner) NAME:Mark Clement COMPANY (if applicable):Boeing ADDRESS:737 Logan Ave n. CITY:Renton ziP: 98055 TELEPHONE NUMBER 206 617-2944 CONTACT PERSON NAME:Mark Clement COMPANY(if applicable):Boeing Co. ADDRESS:737 Logan Ave n. crry:Renton ZIP: 98055 TELEPHONE NUMBER AND E-MAIL ADDRESS:206 617- 2944 Mark.d.clement @ boein.com PROJECT INFORMATION PROJECT OR DEVELOPMENT NAME:Install fabric hangar at Apron D PROJECT/ADDRESS(S)/LOCATION AND ZIP 737 Logan Ave n Renton WA 98055: KING COUNTY ASSESSOR'S ACCOUNT NUMBER(S): 0723059001 EXISTING LAND USE(S):Manufactoring PROPOSED LAND USE(S):Manufactodng EXISTING COMPREHENSIVE PLAN MAP DESIGNATION: PROPOSED COMPREHENSIVE PLAN MAP DESIGNATION (if applicable):NA , EXISTING ZONING Urban Center north 2 PROPOSED ZONING (if applicable):same as existing SITE AREA (in square feet):25,000sq ff SQUARE FOOTAGE OF PUBLIC ROADWAYS TO BE DEDICATED:none SQUARE FOOTAGE OF PRIVATE ACCESS EASEMENTS: PROPOSED RESIDENTIAL DENSITY IN UNITS PER NET ACRE (if applicable):NA O:web/pwldcvservlforms/planningJmastcrapp,doc I 03/I I/08 ! NUMBER OF PROPOSED LOTS (if applicable):NA NUMBER OF NEW DWELLING UNITS (if applicable):NA NUMBER OF EXISTING DWELLING UNITS (if applicable): SQUARE FOOTAGE OF PROPOSED RESIDENTIAL BUILDINGS (If applicable):NA SQUARE FOOTAGE OF EXISTING RESIDENTIAL BUILDINGS TO REMAIN (If applicable):NA SQUARE FOOTAGE OF PROPOSED NON-RESIDENTIAL BUILDINGS (if applicable):23,400sq ft SQUARE FOOTAGE OF EXISTING NON-RESIDENTIAL BUILDINGS TO REMAIN (if applicable):NA NET FLOOR AREA OF NON-RESIDENTIAL BUILDINGS (if applicable):NA PF IECTINFORMATION (conti ,.=d) NUMBER OF EMPLOYEES TO BE EMPLOYED BY THE NEW PROJECT (if applicable):NA PROJECT VALUE:1,1 million IS THE SITE LOCATED IN ANY TYPE OF ENVIRONMENTALLY CRITICAL AREA,PLEASE INCLUDE SQUARE FOOTAGE (if applicable): 0 AQUIFER PROTECTION AREA ONE AQUIFER PROTECTION AREA TWO Q FLOOD HAZARD AREA n GEOLOGIC HAZARD Q HABITAT CONSERVATION Q SHORELINE STREAMS AND LAKES n WETLANDS NA__sq.ft. sq.ft. sq.ft. sq.ft. sq.ft. LEGAL DESCRIPTION OF PROPERTY (Attach legal description on separate sheet with the following Information Included) SITUATE IN THE ne QUARTER OF SECTION7 ,TOWNSHIP _23n ,RANGE_5e ,INTHECITYOFRENTON,KING COUNTY,WASHINGTON, TYPE OF APPLICATION &FEES List all land use applications being applied for: 1.__LSite plan review $1000 3. 2.4. X SEPA CHECKLIST_S500 Staff will calculate applicable fees and postage:$1,500Billed__ AFFIDAVIT OF OWNERSHIP statements and answers herein contai and the ',(Print Name/s)'C {e '(P ,declare that I am (please check one)_the current owner of the property involved In this application or the authorized representative to act for a corperatlon (please attach proof of authorization)and that the foregoing information herewith are in all respects true and correct to the best of my knowledge and belief. I certify that I know or have satisfactory evidence tt//IZ.[,,0,,o,."signed this instrument and acknowledged it to benis/er/the[r free and '01untat:y act for the uses and purposes mentioned in the instrument. (Signature of Owner/Representative) (Signature of Owner/Representative) dfortlieStdlJpofWpshlnton .--v . Q:weh/pw/dvserv/forms/planning/maslcrapp,doc 2 03/I I/08 .OJECT INFORMATION (€ontlnu../ Notary (Print) M,o,°,m°0,o,,,o,:7/z ,/zoO Q:web/pw/dcvserv/fonna/planning/masterapp,doc 3 03/I 1/08 DEVELOPMENT SERVICES DIVISION WAIVER OF SUBMITTAL REQUIRI:MENTS FOR LAND USE APPLICATIONS Environmental Checklist 4 Legal Description 4 Mailing Labels for Property Owners 4 This requirement may be waived by: 1.Property Services Section . 2.Public Works Plan Review Section 3.Building Section 4.Development Planning Section Q:WE BPWDEVS ERVForms\Planning\waivero fsubmi|talreqs 9.0641s PROJECT NAME: DATE: .....t 09/06 EVELOPMENT SERVICES DIVISION WAIVER OF SUBMITTAL REQUIREMENTS FOR LAND USE APPLICATIONS !Parking,Lot Coverage &Landscaping Analysis 4 Reservation,'-..Plat Name Preapplication Meeting Summary ehabilitation Plan,....' Site Plan z Argo 4 Stream or Lake Study,Supplemental 4 Street Profiles .............,,l , ;,,.;?...........:::::'""";'i'i!':';:-...::.:::':..d%1 I I ..:..••.,.,.....,.....,.,-,..+.-..,,.,;,,,;..,;...;,.,.......I....--,,.-.,;...,..*.;.,;.,.;*...;,.. Topography Map ..............:..=;=;: Tree Cutting/Land Clearing Plan , JtBities Plan,Generalized 2 Wetlands Mitigation Plan,Preliminary 4 - /ireless:; Applicant Agreement Statement ,,,NO Inventory of Existing Sites A, Lease Agreement,Draft AND Map of Existing Site Conditions AND Map of View Area AD 3 Photosimulations AND 3 •.*.,.,,..$..'......'k • ,',,,,,,,,,,,,,,,,,,,,,,,,,,, ]'his requirement may be waived by: I.Proparty Services Section _.Public Works Plan Review Section .Building Section ,.Development Planning Section PROJECT NAME: DATE: QAWEBPWD EVSERVFormsPlannlngwaiverofsub mittalreqs 9-06.xls 09/06 DEVELOPMENT PLANNINGCITYOFRENTON Project Narrative MAR 1 3 2008 RECEIVED New Fabric Hangar Apron D Renton Boeing Plant 737 Logan ave n Renton WA 98055 Project size 23,400 sq ft General Scope for Pre-Flight Fabric Hangar Hangar 57'7 high 139.1 width 23,400 gross sq ft. The Boeing Company intends to construct one fabric-covered hangar for 737 size airplanes on Apron D at the Renton Site.The hangar will be composed of steel framework with a fabric covering to withstand exposure to flight line activity. The primary purpose for the hangar is for day one installation activities related to pre- flight preparation of the 737.The secondary use will be for repair and refit activities that require dry conditions,along with a backup location for polish requirements.The 737 aircraft will be primarily un-fueled however,a provision is made to accommodate a fueled aircraft,fueling operations will not occur inside the hangar however.The hangar shall include one fixed end wall and one end wall with roll-up aircraft door.Lighting is required appropriate for aircraft inspection.Shop air is needed for hand tools.The power and data requirements are comparable toeach flight line stall position;including stingers and data outlets.Building requirements include AFFF foam fire protection,containment arid tank for fire water,foam or fuel spill. o Master Land use permit o Zoning is UCN-2 The site use is aircraft manufacturing site o The Renton Boeing site is adjacent to the Cedar river and Lake Washington Soil type is Sandy silt loam;The Project site is currently a 100%impervious or paved surface and,will continue to be impervious at project completion. Apron D is an Aircraft Apron used for pre-flight operations.The new hangar will provide for pre-flight operations away from the weather now being used by the 5-50Painthangar.SEE GENERAL SCOPE ABOVE/ ra PLATS SEE ATTACHED o Access is by N 6TMave r 1.1 million is estimated project cost o Material fills-Granular structural fill will be imported to replace existing soils as base materiel immediately under utilities,foundations and replacement pavementraProjectisbeyond200foftheCedarRiver o No changes to parking in the new Project New Fabric hangar Apron tn t 3 Construction Mitigation plan Proposed Construction Dates Start Construction in early May 2008 and finishing before end of August 2008 Hours and days of Operation The work will be accomplished during day light hours,typically starting at 6:30 am and ending at 4:00pro Mou thru Friday. Proposed Hauling/Transportation routes Contractors will apply for their own hauling permits related to these projects Construction. The actual Construction will be accomplished by a Construction contractor.The Construction is planned to last 3 to 4 months.Construction will start with the implementation and installation of Best Management Practices (BMP)for Temporary Erosion and Sedimentation Control (TESC. Existing utilities will be rerouted and new fire protection tanks will be installed.New fabric hangars will be installed to existing foundation and new utilities installed) Storm Water Construction will start with the implementation and installation of Best Management Practices (BMP)for Temporary Erosion and Sedimentation Control (TESC) under supervision of Boeing Environmental personnel. Snow,lee,dirt and mud removal Contractor shall remove snow and ice to the extent necessary to perform the work.The use of calcium chloride or other chemicals will not be permitted to remove Snow or Ice.Contractor shall assure that vehicles are constructed,loaded,maintained and covered as necessary to prevent the deposition of dirt, mud or other debris on public roadways.Dirt mud or debris shall be removed on continual basis.Any Dirt mud or debris dropped by vehicles shall be removed immediately. Dust Control Through the entire construction period the Contractor shall take all necessary steps to dust control all working area and unpaved roads.The use of calcium chloride or other chemicals will not be permitted for dust control.The Contractor will accomplish dust control by watering and sprinkling to satisfactorily settle the dust. Contractor shall comply with any requirements imposed by law to prevent fugitive dust emissions. Asbestos Abatement No asbestos is thought to be in construction area.Asbestos good faith survey will be completed before construction is started. Protection of people and property The area of work will be enclosed by a fence and will be only accessible to authorized personnel who will be governed by the contractors job specific safety plan. ! Environmental Checklist DEVELOPMENT PLANNINGCITyOFRENToN MAR 1 3 2008 RECEIVED NEW FABRIC HANGAR APRON D BOEING COMMERCIAL AIRPLANE GROUP RENTON WASINGTON MARK CLEMENT PERMITS &LAND USE THE BOEING COMPANY P.O.BOX 3707 MS 1W-09 SEATTLE WASHINGTON 98124 206 617-2994 February 2008 New Fabric Hangar Apron D II RAtNER ii APRON B w# ,I i t ,,i ,,,,,,,'I s APRON C RENTON MUNICIP AL AIRPORT A*t T 5.40 ¸i -pAFING iI DESCRIPTION OF THE BOEING COMMERCIAL AIRPLANE COMPANY RENTON PLANT FACILITY PARCEL I-BO CIT._Y.Y OFRENTON,KING COUNTY,WASHINGTON The following described tract of land is the resultant consolidation of Record Title vested in the Boeing Company,a Delaware Corporation and Puget Sound"Power &Light Company,a Massachusetts Corporation,covered in the Pioneer National Title Insurance Company,Limited Liability Reports Number A-253801,A-253802,A-253803,A-253804,Unit 13,dated January II,through January.21,1980. ALL BEARINGS ARE REFERENCED TO THE GRID MERIDIAN OF THE WASHINGTON COORDINATE SYSTEM,NORTH ZONE. THAT PORTION OF GOVERNMENT LOTS l AND 3 IN SECTION 7;AND OF GOVERNMENT LOTS I,2 AND 3 AND THE NORTHWEST QUARTER OF THE SOUTHWESTQUARTEROFSECTION8,TOWNSHIP 23 NORTH,RANGE 5 EAST,WILLAMETTE MERIDIAN,IN THE CITY OF RENTON,KING COUNTY,WASHINGTON;AND OF C.H. ADSIT'S LAKE WASHINGTON PLAT AS RECORDED IN VOLUME 8 OF PLATS,PAGE 79,RECORDS OF KING COUNTY,WASHINGTON;AND OF BLOCK C,THIRD SUPPLEMENTAL MAP OF LAKE WASHINGTON SHORE LANDS,AS RECORDED UNDER KING COUNTY AUDITOR'S FILE NUMBER 5927582;AND OF CERTAIN SHORE LANDS OF LAKE WASHINGTON SHOWN ON SHEETS 3 AND 4 OF THE MAP PREPARED BY UDO HESSE UNDER KING COUNTY SUPERIOR COURT CAUSE NUMBER 156371;AND OF VACATED LAKE WASHINGTON BOULEVARD (FORMERLY PARK STREET);AND OF THE ABANDONED BURLINGTON NORTHERN INC.RAILWAY (FORMERLY NORTHERN PACIFIC RAILWAY)RIGHT-OF-WAY,ALL MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE INTERSECTION OF THE NORTH MARGIN OF SIXTH AVENUE NORTH AND THE EASTERLY RIGHT-OF-WAY LINE OF COMMERCIAL WATERWAY DISTRICT NO.2 IN GOVERNMENT LOT 2 OF SAID SECTION 7;THENCE WITH SAID EASTERLY RIGHT-OF-WAY LINE NORTH 12°47'42"WEST 193.18 FEET; NORTH 00022'54 ''EAST 454.50 FEET;NORTH 12°47'42"WEST 2394.32 FEET TO THE SOUTHWEST CORNER OF BLOCK C,SAID THIRD SUPPLEMENTAL MAP OF LAKE WASHINGTON SHORE LANDS;THENCE WITH THE BOUNDARIES OF SAID BLOCK C,NORTH 12047'42 ''WEST 264.08 FEET TO THE NORTHWEST CORNER THEREOF;THENCE CONTINUING WITH THE BOUNDARIES OF SAID BLOCK C,NORTH 84o25'26 ''EAST 1299.96 FEET TO THE NORTHEAST CORNER THEREOF,BEING ON THE INNER HARBOR LINE OF LAKE WASHINGTON SHORE LANDS IN SAID SECTION 7;THENCE WITH SAID INNER HARBOR LINE NORTH 46052'27 ''EAST 977.56 FEET; /-I- PARCEL 1-80 (Continued) THENCE WITHIN SAID SHORE LANDS SOUTH 43°06'56 ''EAST 932.91 FEET; SOUTH 46°53'04 ''WEST 220.00 FEET;SOUTH 31°37'32 ''EAST 44B.37 FEET TO THE NORTHWESTERLY MARGIN OF SAID BURLINGTON NORTHERN, INC.RIGHT-OF-WAY IN GOVERNMENT LOT 2 OF SAID SECTION 8;THENCE WITH SAID RIGHT-OF-WAY SOUTH SO°41'4B ''WEST 24-8.33 FEET TO THE POINT OF CURVATURE OF A CURVE TO THE LEFT OF RADIUS 12,769.67 FEET;THENCE SOUTHWESTERLY WITH SAID CURVE (THROUGH A CENTRAL ANGLE OF O°lO'O0 ")37.15 FEET TO THE POINT'OF COMPOUND CURVATURE WITH'R CURVE TO THE LEFT OF RADIUS 6409.84 FEET;THENCE SOVTH- WESTERLY ALONG SAID COMPOUND CURVE (THROUGH A CENTRAL ANGLE OF O°20'O0 '')37.29 FEET TO THE POINT OF COMPOUND CURVATURE WITH A CURVE to THE LEFT OF RADIUS 4289.90 FEET;THENCE SOUTHWESTERLY ALONG SAID COMPOUND CURVE (THROUGH A CENTRAL ANGLE OF 0°30'00") 37.44 NEET TO THE POINT OF COMPOUND CURVATURE WITH A CURVE TO THE LEFT OF RADIUS 3229.93 FEET; THENCE SOUTHWESTERLY ALONG SAID COMPOUND CURVE (THROUGH A CENTRAL ANGLE OF 0°40'00 '')37.58 FEET TO THE POINT OF COMPOUND CURVATURE WITH A CURVE TO THE LEFT OF RADIUS 2593.96 FEET;THENCE SOUTH- WESTERLY ALONG SAID COMPOUND CURVE (THROUGH A CENTRAL ANGLE OF 0°50'00 '')37,73 FEET TO THE POINT OF COMPOUND CURVATURE WITH A CURVE TO THE LEFT OF RADIUS 2169,97 FEET;THENCE SOUTHWESTERLYALONGSAIDCOMPOUNDCURVE(THROUGH A CENTRAL ANGLE OF Ol°O0'O0 '') 37,87 FEET TO THE POINT OF COMPOUND CURVATURE WITH A CURVE TO THE LEFT OF RADIUS 1867.13 FEET;THENCE SOUTHWESTERLY ALONG SAIDCOMPOUNDCURVE(THROUGH A CENTPL ANGLE OF 0]°I0'00 '')38.02 FEET TO THE POINT OF COMPOUND CURVATURE WITH A CURVE TO THE LEFT OF RADIUS 1639.99 FEET; THENCE SOUTHWESTERLY ALONG SAID COMPOUND CURVE (THROUGH A CENTRAL ANGLE OF 01°20'00 ")38.16 FEET TO THE POINT OF COMPOUND CURVATURE WITH A CURVE TO THE LEFT OF RADIUS 1482.69 FEET;THENCE SOUTH- WESTERLY ALONG SAID COMPOUND CURVE 140.74 FEET TO A POINT ON SAID NORTHWESTERLY MARGIN FROM WHENCE THE CENTER OF SAID CURVE BEARS SOUTH 50°44'31 ''EAST;THENCE WITHIN SAID RIGHT-OF-WAY NORTH 53°32'36 ''EAST 854.31 FEET;NORTH 49°53'02 ''EAST 606.40 FEET;SOUTH 44°22'57"EAST 25.00 FEET TO A POINT ON THE SOUTH- EASTERLY MARGIN OF SAID RAILWAY RIGHT-OF-WAY,SAID POINT BEING SOUTHEASTERLY AND RADIAL FROM THE MAIN TRACK CENTERLINE :SURVEY STATION ]068+00,SAID POINT BEING ON A CURVE TO THE RIGHT FROM WHENCE THE CENTER BEARS NORTH 44°22'57 ''WEST 1639.99 FEET; THENCE SOUTHWESTERLY ALONG SAID RIGHT-OF-WAY WITH SAID CURVE (THROUGH A CENTRAL ANGLE OF 00°24'45 '')ll.8]FEET TO THE POINT OF COMPOUND CURVATURE WITH A CURVE TO THE RIGHT OF RADIUS 1867.13 FEET;THENCE SOUTHWESTERLY ALONG SAID COMPOUND CURVE (THROUGH A CENTRAL ANGLE OF 00040'33 '')22.02 FEET TO A POINT FROM WHENCE THE CENTER OF SAID CURVE BEARS NORTH 43°17'39"WEST,SAID POINT BEING ON THE SOUTHWESTERLY RIGHT-OF-WAY OF PRIORY STATE HIGHWAY 0.I (SR 405)NORTH RENTON IHTERCHANGEI -2- PARCEL I-BO (Continued) CONTAINING 204.]7 ACRES,OR 8,893,560 SQUARE FEET,MORE OR LESS. REFERENCE IS HEREBY MADE TO OWNERSHIP MAPS,RENTON PLANT FACILITIES, ]gso PROPERTY CONSOLIDATION,SHEETS l,2,3,4,5 AND 6 OF 6 SHEETS. -4- BOEING COM,U E RCIA L AIRPL COHPAHY A DIVISION OF THE BOEING COMPANY R EN,rON PLANT FACILITY W PARC -IL 1"80 8,895,560 SQUARE FEET 204.17 ACRES tO0 ]00 p 6 O0 !I0€tlO $€IL[I F[(I CITY OF RENTON +l KING COUNTY,WASHINGTON WIL LANIE'r TIc MERIDIAN T23N.RSE I"80 ioaf Ifll IYII|! I I NEW FABRIC HANGAR APRON D ENVIRONMENTAl CHECKLIST A.BACKGROUND 1.Name of proposed proJect,lf applicable: New Fabric hangar on Apron D 2.Name of applicant. The Boeing Company P.O.Box 3707,M/S 63-01 Seattle,WA 98124-2207 3.Addrese and phone number of appllcant and contact person: Mark Clement Facilities Permits&Land use The Boeing Company P.O.Box 3707,M/S 1W-09 Seattle,WA 98124-2207 [206 878-3772] 4.Date checklist prepared: Feb.,2008 5.Agency requesting checklist: City of Renton 6.Proposed timing or schedule (including phasing,If applicable): Construction:Spring,summer 2008 7.Do you have any plans for future additions,expansion,or further activity related to or connected with this proposal?If yes,explain. Remodel 5-50 paint Hangar 8.List any environmental Information you know about that has been prepared,or will be prepared,directly related to this proposal. None 9.Do you know whether applications are pending for governmental approvals of other proposals directly affecting the property covered by your proposal?If yes,explain. None known ENVIRONMENTAL CHECKLIST "NEW FABRIC HANGAR APRON D 10.List any government approvals or permits that will be needed for your proposal,ff known. Federal: None known at this time State of Washington: None known at this time King County: None known at this time City of Rsnton/Local: Building Permit,Fire permit 11.Give brief,complete description of your proposal,Including the proposed uses and the size of the project and site.There are several questions later in thls checklist that ask you to descrlbe certaln aspects of your proposaL You do not need to repeat those answers on this page.(Lead agencies may modify this form to Include additional specific Information on project description.) The Boeing Company intends to construct one fabric-covered hangar for 737 size airplanes on Apron D at the Renton Site.The hangar will be composed of steel framework with a fabric covering to withstand exposure to flight line activity. The primary purpose for the hangar is for day one installation activities related to pre- flight preparation of the 737.The secondary use will be for repair and refit activities that require dry conditions,along with a backup location for polish requirements.The 737 aircraft will be primarily un-fueled however,a provision is made to accommodate a fueled aircraft,fueling operations will not occur inside the hangar however.The hangar shall include one fixed end wall and one end wall with roll-up aircraft door.Lighting is required appropriate for aircraft inspection.Shop air is needed for hand tools.The power and data requirements are comparable to each flight line stall position;including stingers and data outlets.Building requirements include AFFF foam fire protection,containment •and tank for fire water,foam or fuel spill. 12.Location of the proposal Give sufficient Information for a person to understand the precise location of your proposed project,Including a street address,If any,and section,township,and range,if known.If a proposal would occur over a range of area,provide the range or boundaries of the site(s).Provide a legal description,site plan,vicinity map,and topographic map,if reasonably avallable.Whlle you should submlt any plans requlred by the agency,you are not required to duplicate maps or detailed plans submitted with any permit applications related to this checklist. ENVIRONMENTAL CHECKLIST NEW FABRIC HANGAR APRON D Site address:737 Logan ave n, Renton,Washington 98055 B.ENVIRONMENTAL ELEMENTS 1.Earth a.General description of the site (circle one):Flat,roiling,hilly,steep slopes,mountainous,other ...... Flat; b.What is the steepest slope on the site (approximate percent slope)? 1%; c.What general types of soils are found on the site (for example,clay, sand,gravel,peat,muck)?ff you know the classification of agricultural soils,specify them and note any prime farmland. Sandy silt loam; d.Are there surface Indications or history of unstable soils In the immediate vicinity?ff so,describe. None known.The soil at one to 4 feet or so is fill (USDA classification:Loamy Sand,USCS classification:Silty sand).The soil from the bottom of the fill to depths of about 8 to 10 feet was mainly silt (USDA and USCS:Silt). Infiltration potential will be low. e.Describe the purpose,type,and approximate quantities of any filling or grading proposed.Indicate source of fill. The hangar is being placed over existing concrete pavement and there will be no significant grading and no significant filling.Granular structural fill will be imported to replace existing soils as base material immediately under utilities,foundations and replacement pavement f.Could erosion occur as a result of clearing,construction,or use?If so, generally describe. No. g.About what percent of the site will be covered with Impervious surfaces after project construction (for example,asphalt or buildings)? ENVIRONMENTAL CHECKLIST NEW FABRIC HANGAR APRON 1 g.About what percent of the site will be covered with Impervious surfaces after project construction (for example,asphalt or buildings)? The site is currently a 100%impervious or paved surface and,will continue to be impervious atproject completion. h.Proposed measures to reduce or control erosion,or other Impacts to the earth,If any: Appropriate measures,such as silt fences and hay bale filters,will be used to control erosion during demolition and construction.After demolition,and after the parking and dolly storage lots are constructed,exposed soils will be covered with asphalt.Specific erosion control measures will be detailed on the grading plans submitted for permit approval. 2.Air a.What types of emissions to the air would result from the proposal (i.e., dust,automobile,odors,and Industrial wood smoke)during construction and when the project Is completed?If any,generally describe and give approximate quantities ff known. During Construction,limited vehicle and construction equipment emissions and dust will be released. b.Are there any off-site sources of emissions or odor that may affect your proposal?If so,generally describe. No c.Proposed measures to reduce or control emissions or other Impacts to air,if any: Mitigation measures will be implemented as required to meet or exceed all applicable standards as required by the Puget Sound Clean Air Agency and the Department of Ecology.Additional potential mitigation measures to reduce emissions include ensuring that machines and equipment used during construction are well maintained. 3.Water a.Surface: ENVIRONMENTAL CHECKLIST NEW FABRIC HANGAR APRON D b. 1)Is there any surface water body on or In the Immediate vicinity of the site (Including year-round and seasonal streams,saltwater,lakes, ponds,wetlands)?If yes,describe type and provide names.If appropriate,state what stream or river it flows Into. The Cedar River and Lake Washington are in the vicinity; 2)Will the project require any work over,In,or adjacent to (within 200 feet)the described waters?If yes,please describe and attach available plans. No 3)Estimate the amount of l and dredge material that would be placed in or removed from surface water or wetlands and Indicate the area of the site that would be affected.Indicate the source of fill material. None 4)Will the proposal require surface water withdrawals or diversions? Give general description,purpose,and approximate quantities if known. No 5)Does the proposal lie within a lO0-year floodplain?ff so,note location on the site plan. No 6)Does the proposal Involve any discharges of waste materials to surface waters?If so,describe the type of waste and anticipated volume of discharge. No Ground: 1)Will ground water be withdrawn,or will water be discharged to ground water?Give general description,purpose,and approximate quantities If known. No 2)Describe waste material that will be discharged Into the ground from septic tanks or other sources,If any (for example:Domestic sewage; industrial,containing the following chemicals...;agricultural;etc.). Describe the general size of the system,the number of such systems, the number of houses to be served (if applicable),or the number of animals or humans the system(s)are expected to serve. ENVIRONMENTAL CHECKLIST ••NEW FABRIC HANGAR APRON D None c.Water.Water runoff (including storm-water): 1)Describe the source of runoff (including storm water)and method of collection and disposal,ff any (include quantities,ff known).Where will this water flow?Will this water flow Into other waters?ff so,describe. Storm water runoff will be collected in the existing plant's storm-water control system.No additional impervious surface or runoff wilt be created by the project. 2)Could waste materials enter ground or surface waters?ff so, generally describe. No d.Proposed measures to reduce or control surface,ground,and runoff water Impacts,ff any: Utilize existing onsite storm water system to mitigate potential runoff water impacts.Appropriate mitigation measures will be initiated during construction to reduce and control surface water runoff impacts.Note Construction is less than 1 acre. 4.Plants al Check or circle types of vegetation found on the site: deciduous tree:alder,maple,aspen,other cottonwoods evergreen tree:fir,cedar,pine,other shrubs,grass,pasture,crop or grain, wet soll plants:*cattall,*buttercup,*bulrush,*skunk cabbage,other water plants:*water lily,eelgrass,milfoll other types of vegetation b.What kind and amount of vegetation will be removed or altered? None c.List threatened or endangered species known to be on or near the site. None; d.Proposed landscaping,use of native plants,or other measures to preserve or enhance vegetation on the site,If any: NA ENVIRONMENTAL CHECKLIST NEW FABRIC HANGAR APRON b 5.Animals a.Circle any birds and animals,which have been observed on or near the site or are known to be on or near the site: Birds and animals which have been observed on or near the site are listed below: birds: mammals: fish: seagulls,crows none observed coho salmon,chinook salmon sockeye salmon steelhead and cutthroat trout,native char (bull trout) b.List any threatened or endangered species known to be on or near the site. None;. c.Is the site part of a migration route?If so,explain. Pacific Flyway; d.Proposed measures to preserve or enhance wildlife,ff any: Utilize temporary erosion;long-term storm water and hazardous materials control systems and best management practices to prevent contaminated discharges. 6.Energy end natural resources a.What kinds of energy (electric,natural gas,o11,wood stove,solar)will be used to meet the completed project's energy needs ?Describe whether It will be used for heating,manufacturing,etc. None b.Would your project affect the potential use of solar energy by adjacent properties?If so,generally describe. No c.What kinds of energy conservation features are Included in the plans of this proposal?List other proposed measures to reduce or control energy impacts,if any: None 7.Environmental Health ENVIRONMENTAL CHECKLIST NEW FABRIC HANGAR APRON b 1 a.Are there any environmental health hazards,Including exposure to toxic chemicals,risk of fire and explosion,spill,or hazardous waste,that could occur as a result of this proposal?ff so,describe. Usual oils,greases,fuel and solvents will be present during Construction. 1)Describe special emergency services that might be required. No special emergency services will be required. 2)Proposed measures to reduce or control environmental health hazards,If any: None b.Noise 1)What types of noise exist In the area which may affect your project (for example:traffic,equipment,operation,other)? None 2)What types and levels of noise would be created by or associated with the project on a short-term or a long-term basis (for example: traffic,construction,operation,other)?Indicate what hours noise would come from the site. Temporary noise impacts during construction are anticipated,Construction projects of this type typically produce noise levels that range from 68 to 98 dba at 50 feet from the specific equipment. 3)Proposed measures to reduce or control noise impacts,if any: None Land and shoreline use a.What Is the current use of the site and adjacent properties? The site is fully developed as an aircraft manufacturing and final assembly facility.See 2003 Boeing EIS. b.Has the site been used for agriculture?ff so,describe. No c.Describe any structures on the site. ENVIRONMENTAL CHECKLIST ••NEW FABRIC HANGAR APRON L, The Renton Plant is a large airplane manufacturing and final assembly facility,consisting of many buildings and ancillary uses.The project site is within the Renton Plant.The structures on Apron D are small crew shelters [Confirm that there are no other structures located on the project site.] d.Will any structures be demolished?If so,what? None. e.What Is the current zoning classification of the site? UCN-2 f.What Is the current comprehensive plan designation of the site? UCN-2 g.ff applicable,what Is the current shoreline master program designation of the site? Urban Center north 2 h.Has any part of the site been classified as an "environmentally sensitive"area?If so,specify. No L Approximately how many people would reside or work In the completed project? None J.Approxlmately how many people would the completed project displace? None,site. k.Proposed measures to avoid or reduce displacement Impacts,ff any: None L Proposed measures to ensure the proposal are compatible with existing and projected land uses and plans,If any: Compliance with city codes and ordinances and consistent with Conceptual Plan for Subdistrict 1A approved in the Boeing Development Agreement.. 9.Housing a.Approximately how many units would be provided,If any?Indicate whether high,middle,or low.income housing. ENVIRONMENTAL CHECKLIST "-[NEW FABRIC HANGAR APRON b None b.Approximately how many unite,ff any,would be eliminated?Indicate whether high,middle,or low-Income housing. None c.Proposed measures to reduce or control housing Impacts,If any" None 10.Aesthetics a.What is the tallest height of any proposed structure(s),not Including antennas;what Is the principal exterior building material(s)proposed? 57.7 Fabric b.What views In the Immediate vicinity would be altered or obstructed? None c.Proposed measures to reduce or control aesthetic impacts,ff any: None 11.Light and glare a.What type of light or glare will the proposal produce?What time of day would it mainly occur? None b.Could light or glare from the finished project be a safety hazard or Interfere with views? No c.What existing off-site sources of light or glare may affect your proposal? None anticipated. d.Proposed measures to reduce or control light and glare Impacts,If any: None ENVIRONMENTAL CHECKLIST NEW FABRIC HANGAR APRON b 12.Recreation a.What designated and Informal recreational opportunities are in the Immediate vicinity? The Cedar River shoreline trail and park are within the general area of the Renton Site.See 2003 Boeing EIS. b.Would the proposed project displace any existing recreational uses?If so,describe. No c.Proposed measures to reduce or control Impacts on recreation, Including recreation opportunities to be provided by the project or applicant,If any: None 13.Historic and Cultural Preservation a.Are there any places or objects listed on,or proposed for,national, state,or local preservation registers known to be on or next to the site?ff so,generally describe. No b.Generally descrlbe any landmarks or evldence of hlstorlc, archaeological,scientific,or cultural Importance known to be on or next to the site. None have been identified on the project site. c.Proposed measures to reduce or control Impacts,if any: Although previous excavation has disclosed no indications of archaeological significance,if artifacts are uncovered,work in that area will be halted pending notification and response from appropriate agencies. 14.Transportation a.Identify public streets and highways serving the site,and describe proposed access to the existing street system.Show on site plans,If any.IhThesitehasaccesstoNorth6 Street and Logan Avenue North.See 2003 Boeing EIS and Boeing Development Agreement. b.Is site currently served by public transit?If not,what Is the approximate distance to the nearest transit stop? ENVIRONMENTAL CHECKLIST NEW FABRIC HANGAR APRON b Yes,. c.How many parking spaces would the completed project have?How many would the project eliminate? No parking stalls will be lost as a part of this action, d.Will the proposal require any new roads or streets,or Improvements to existing roads or streets,not Including driveways?If so,generally describe (indicate whether public or private). No e.Will the project use (or occur in the Immediate vicinity of)water,rail,or air transportation?ff so,generally describe. Yes Apron D,is Adjacent to Renton municipal airport f.How many vehicular trips per day would be generated by the completed project?If known,Indicate when peak volumes would occur. None g.Proposed measures to reduce or control transportation Impacts,ff any: No impacts anticipated 15.Public Services a.Would the project result In an Increased need for public services (for example:fire protection,police protection,health care,schools,other)?ff so,generally describe. None is anticipated. b.Proposed measures to reduce or control direct Impacts on public services,If any. None 16.gtlUtles a.Circle utilities currently available at the site:electricity,natural gas, water,refuse service,telephone,sanitary sewer,septic system,other. Electricity,natural gas,domestic water,refuse service,telephone,sanitary sewer and storm sewerage are currently available. ENVIRONMENTAL CHECKLIST "NEW FABRIC HANGAR APRON u b.Describe the utilities that are proposed for the project,the utility providing 1he service and the general construction activities on the site or in the Immediate vicinity,which might be needed. The following utilities,which already exist on the site in the vicinity of the project, will be utilized within the hangar and immediately outside the hangar: 60 Hz electrical service for the building and site. 400 Hz electric service for aircraft, Data and telephone. Domestic water. Fire protection water. Plant compressed air. Storm sewer (outside the hangar). Sanitary sewer (inside the hangar). Refuse service. C.SIGNATURE The above answers are true and complete to the best of my knowledge.I Understand that the lead agency is relying on them to make its decision. Signature:f/'/''"/''Z" z Mark D Clement DateSubml.ed:/0 ENVIRONMENTAL CHECKLIST Form WA-S (6/76) 'Commitment Face Page File No.:NCS-339701-WA1 COMMITMENT FOR TITLE INSURANCE Issued by FIRSTAMERICAN TITLE INSURANCE COMPANY First American Title [nsurence Company,herein called the Company,for valuable consideration,hereby commits to issue its policy or policies of title Insurance,as identified in Schedule A,In favor of the proposed Insured named In Schedule A,as owner or mortgagor of the estate or Interest covered hereby in the land described or referred to in Schedule A,upon payment of the premiums and charges therefor;all subject to the provisions of Schedules A and B and to the Conditions and Stipulations hereof. This Commitment shall be effective only when the identity of the proposed Insured and the amount of the policy or policies committed for have been inserted In Schedule A hereof by the Company,either at the time of the Issuance of the Commitment or by subsequent endorsement. This Commitment if preliminary to the issuance of such policy or policies of title insurance and all liability and obligations hereunder shall cease anti terminate six (6)months afer the effective date hereof or when the policy or policies committed for shall Issue,whichever first occurs,provided that the failure to issue such policy or policies Is not the fault of the Company.This Commitment shall not be valid or binding until countersigned by an authorized officer or agent. IN WITNESS WHEREOF,the Company has caused this commitment to be signed and sealed to become valid when countersigned by an authorized officer or agent of the Company,all in accordance with its By-Laws.This Commitment is effective as of the date shown in Schedule A as "Effective Date." By: Atte: First American Title Insurance Company //(..c --/--'----"President /'/,4_Secretary By:F¢'..COUntersig ned FirstAmerican Title Insurance Company Form WA-S (6/76) Commitment File No.:NCS-339701-WA1 Page No,1 First American Title Insurance Company National Commercial Services 2101 Fourth Avenue,Suite 800,Seattle,WA 98121 (206)728-0400 -FAX (206)448-6348 Hike Cooper (206)615-3107 rncooper@flrstam.com Vincent Nguyenpham (206)615-3267 vnguyenpham@flrstam.com To:Boeing Realty Corporation THton Tower Two,MC 6R6-10,700 S Renton Village PI. Renton,WA 98055-3235 File No.:NCS-339701-WA1 Your Ref No.:800 Park Ave.N Attn:Jeff Adelson SCHEDULEA 1.Commitment Date:February 12,2008 at 7:30 A.M. .Policy or Policies to be issued: AMOUNT PREMIUM TAX Standard Owner's Coverage $To Follow $To Follow $To Follow . Proposed Insured: To Follow The estate or Interest in the land described on Page 2 herein is Fee Simple,and title therete is at the effective date hereof vested in: The Boeing Company,a Delaware corporation 4.The land referred to in this Commitment is described as follows: The land referred to in this report is described tn Exhibit "A"attached hereto. FirstAmerican 17tie Insurance Company Form WA-5 (6/76)File No.:NC.S-33970[-WA1 Commitment Page No.2 EXHIBIT 'A' LEGAL DESCRIPTION: PARCEL A: A PORTION OF THE SOUTHEAST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 7,TOWNSHIP 23 NORTH,RANGE 5 EAST,W.M.,IN KING COUNTY WASHINGTON,LYING EASTERLY OF THE COMMERaAL WATERWAY DISTRICT NO.2 RIGHT-OF-WAY AND WESTERLY OF LOGAN STREET NORTH EXTENSION AS DEEDED TO THE STATE OF WASHINGTON,BY DEED RECORDED UNDER RECORDING NO.3261297,DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTH MARGIN OF 6TH AVENUE NORTH AND THE WEST MARGIN OF LOGAN STREET NORTH; THENCE NORTH 89°34'11"WEST ALONG THE SOUTH MARGIN OF 6TH AVENUE NORTH,674.91 FEET TO THE MOST NORTHERLY AND WESTERLY CORNER OF A TRACT OF LAND CONVEYED TO THE BOEING COMPANY,BY DEED RECORDED FEBRUARY 21,1964 UNDER RECORDING NO.5701683,AND THE TRUE POINT OF BEGINNING; THENCE CONTINUING NORTH 89°34'1"WEST ALONG SAID SOUTH MARGIN,44134 FEET TO THE EASTERLY RIGHT-OF-WAY LINE OF COMMERCIAL WATERWAY DISTRICT NO.2,AS CONDEMNED IN KING COUNTY SUPERIOR COURT CAUSE NO.211409; THENCE SOUTH 12°47'42''EAST ALONG SAID RIGHT-OF-WAY LINE,328.72 FEET TO INTERSECTION WITH A UNE PARALLEL WITH AND 320.00 FEET SOUTH OF,MEASURED AT RIGHT ANGLES TO,THE SOUTH MARGIN OF 6TH AVENUE NORTH; THENCE SOUTH 89°34'11"EAST ALONG SAID PARALLEL LINE,366.34 FEET; THENCE NORTH 0025'49"EAST 320.00 FEET TO THE TRUE POINT OF BEGINNING. EXCEPTING THEREFROM ANY PORTION LYING WITHIN STATE ROAD NO.7,BY DEED RECORDED JUNE 27, 1910 UNDER RECORDING NO.690659 IN KING COUNTY,WASHINGTON. PARCEL B: PORTION OF EAST HALF OF SECTION 7,TOWNSHIP 23 NORTH,RANGE 5 EAST,W.M.,IN KING COUNTY, WASHINGTON,LYING EASTERLY OF THE CEDAR RIVER WATER WAY NO.2 AND NORTHERLY OF NORTH 6TH STREET IN THE SOUTHEASTERLY QUARTER OF SAID SECTION, EXCEPT THAT PORTION FOR NORTHERN PACIFIC RAILWAY RIGHT-OF-WAY; EXCEPT STREETS; TOGETHER WITH VACATED LOGAN STREET LYING NORTHWESTERLY OF A LINE 30 FEET NORTHWESTERLY OF THE GOVERNMENT MEANDER LINE; TOGETHER WITH SECOND CLASS SHORE LANDS ADJACENT; First American Title Insurance Company Form WA-5 (6/76)File No.;NCS-339701-WA1 Commitment Page No.3 TOGETHER WITH THAT PORTION OF SOUTHEAST QUARTER OF THE SOUTHEAST QUARTER OF SAID SECTION; BEGINNING AT THE INTERSECTION OF SOUTH MARGIN OF NORTH 6TH STREET AND THE MARGIN OF LOGAN STREET NORTH; THENCE SOUTHERLY ALONG SAID STREET 995.34 FEET; THENCE SOUTH 89018'45"WEST TO THE EASTERLY MARGIN OF CEDAR RIVER WATER WAY NO.2; THENCE NORTH ALONG SAID MARGIN TO THE SOUTH MARGIN OF NORTH 6TH STREET; THENCE EAST TO THE POINT OF BEGINNING; EXCEPT THAT PORTION BEGINNING AT THE NORTHWEST CORNER THEREOF; THENCE SOUTHEASTERLY ALONG THE WESTERLY LINE 328.75 FEET; THENCE NORTH 89045'45''EAST 366.34 FEET; THENCE NORTH 00o14'15"WEST TO THE SOUTHERLY MARGIN OF NORTH 6TH STREET; THENCE WEST TO THE POINT OF BEGINNING; EXCEPT THE SOUTH 137.70 FEET THEREOF; TOGETHER WITH PORTIONS OF THE NORTHWEST QUARTER OF SECTION 8,TOWNSHIP 23 NORTH,RANGE 5 EAST AND THE SOUTHEAST QUARTER OF SECTION 6,TOWNSHIP 23 NORTH,RANGE 5 EAST AND SOUTHWEST QUARTER OF SECTION 5,TOWNSHIP 23 NORTH,RANGE 5 EAST,LYING NORTHWESTERLY OF THE NORTHERN PACIFIC RAILWAY RIGHT-OF-WAY AND SOUTHWESTERLY OF A LINE BEGINNING AT THE INTERSECTION OF THE WESTERLY EXTENSION OF THE NORTH LINE OF GOVERNMENT LOT 1 WITH THE WEST MARGIN SAID RIGHT-OF-WAY; THENCE WEST 763.39 FEET; THENCE NORTH 43008'56''WEST 680.06 FEET MORE OR LESS TO THE INNER HARBOR LINE; THENCE SOUTH 46o52'27"WEST ALONG SAID LINE 607.89 FEET TO THE TRUE POINT OF BEGINNING; THENCE SOUTH 43006'56"EAST 713.87 FEET; THENCE SOUTH 46053'04'WEST 215 FEET; THENCE SOUTH 20038'24'WEST TO THE NORTHWESTERLY MARGIN OF SAID NORTHERN PACIFIC RIGHT-OF- WAY; EXCEPT BURLINGTON NORTHERN OPERATING STRIP AD1OINING PORTION OF SOUTHEASTERLY LINE IN SAID SECTION 8,TOWNSHIP 23 NORTH,RANGE 5 EAST; EXCEPT ROAD NO.7; TOGETHER WITH VACATED LOGAN STREET LYING NORTHERLY OF SPUR TRACKS; TOGETHER WITH BLOCK C LAKE WASHINGTON SHORE LANDS 3RD SUPPLEMENTAL; EXCEPT THAT PORTION CONVEYED TO CITY OF RENTON,A MUNICIPAL CORPORATION,BY DEED RECORDED AUGUST 17,2006 AND DECEMBER 12,2006 UNDER RECORDING NO'S.20060817000676 AND 20061212000338 OF OFFICIAL RECORDS. ./ FirstAmerican Title Insurance Company Form WA-S (6/76)Rle No,:NCS-339701-WAI Commitment Page No.4 SCHEDULE B -SECTION 1 REOUIREMENTS The following are the Requirements to be complied with: ]tam (A)Payment to or for the account of the Grantors or Mortgagors of the full consideration for the estate or interest to be insured. Item (8)Proper Instrument(s)creating the estate or Interest to be insured must be executed and duly filed for record. Item (C)Pay us the premiums,fees and charges for the policy, Item (D)You must tell us in writing the name of anyone not referred to in this Commitment who will get an interest in the land or who will make a loan on the land.We may then make additional requirements or exceptions SCHEDULE B -SECTION 2 GENERAL EXCEPTIONS The Policy or Policies to be issued will contain Exceptions to the following unless the same are disposed of to the satisfaction of the Company. A,Taxes or assessments which are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the public records. B,Any facts,rights,interest,or claims which are not shown by the public records but which could be ascertained by an inspection of said land or by making inquiry of person in possession thereof. C.Easements,claims of easement or encumbrances which are not shown by the public records. D.Discrepancies,conflicts in boundary lines,shortage in area,encroachments,or any other facts which a correct survey would disclose,and which are not shown by public records. E (1)Unpatented mining claims;(2)reservations or exceptions In patents or in acts authorizing the Issuance thereof;(3)Water rights,claims or title to water;whether or not the matters excepted under (1),(2)or (3)are shown by the public records;(4)Indian Tribal Codes or Regulations, Indian Treaty or Aboriginal Rights,including easements or equitable servitudes. F,Any lien,or right to a lien,for services,labor,materials or medical assistance theretofore or hereafter furnished,Imposed by law and not shown by the public records. G,Any service,installation,connection,maintenance,construction,tap or reimbursement charges/costs for sewer,water,garbage or electricity. H,Defects,liens,encumbrances,adverse claims or other matters,If any,created,first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date the proposed Insured acquires of record for value the estate or Interest or mortgages thereon covered by this Commitment. FirstAmerican 7-/tie Insurance Company Form WA-5 (6/76) Commitment Rle No.:NCS-339701-WA1 Page No.5 SCHEDULE B-SECTION 2 (continued) SPECIAL EXCEPTIONS ,Lien of the Real Estate Excise Sales Tax and Surcharge upon any sale of said premises,if unpaid.As of the date herein,the excise tax rate for the City of Renton is at 1.78%. Levy/Area Code:2100 For all transactions recorded on or after 3uly 1 2005: •A fee of $10,00 will be charged on all exempt transactions; •A fee of $5.00 will be charged on all taxable transactions In addition to the excise tax due. ,General Taxes for the year 2008. Tax Account No.:072305-9046-08 Amount Billed:$16,452.46 Amount Paid:$0.00 Amount Due:$16,452.46 Assessed Land Value:$1,681,400.00 Assessed Improvement Value:$0.00 (Affects Parcel No.A) ,General Taxes for the year 2008. Tax Account No.:072305-9001-01 Amount Billed:$1,938,298.20 Amount Paid:$0.00 Amount Due:$1,938,298.20 Assessed LandValue:"$89,622,700.00 Assessed Improvement Value:$108,614,000.00 4. (Affects Parcel No.B) Agreement to Indemnify the United States of America against damages arising by mason of the lowering of Lake Washington,recorded 3anuary 3,1907,under Recording No.450952. (Affects Parcel No,B) .Agreement and the terms and conditions thereof: By:Puget Sound Power &Light Company,a Washington corporation;and Pacific Coast Railroad Company,a Washington corporation (formerly known and called Columbia &Puget Sound Railroad Company) Recorded:January 2,1929 Recording No.:2509355 Regarding:.Joint usage of harbor area (Affects Parcel No.B) First American T/tie/nsurance Company Form WA-5 (6/76)File No.:NCS-339701-WA1 Commitment Page No.6 ,Matters that may be determined by examination of City of Renton Ordinance Nos.1146 and 2201.Said Ordinances are not available for examination. (Affects Parcel No.B) 7,Easement,Including terms and Recording information: In Favor of: For: Affects: provisions contained therein: November 18,1941 under Recording No.3204562 Pacific Coast R.R.Co. Spur track (Parcel B)portion of said premises ,Easement,Including terms and Recording Information: In Favor of: For: Affects: provisions contained therein: May 19,1942 under Recording No.3241098 State of Washington Public road and highway (Parcel B)as described therein ,Easement,including terms and Recording Information: In Favor of: For: Affects: provisions contained therein: January 27,1943 under Recording No.3289034 The City of Renton Drainage pipeline (Parcel B)portion of said premises 10.The terms and provisions contained In the document entiUed Permit,executed by and between The City of Seattle,a municipal corporation and The City of Renton,recorded March 29,1943 as Instrument No.3299638 of Official Records. (Affects Parcel No.B) 11.Easement,including terms and Recording Information: In Favor of: For: Affects: provisions contained therein: December 2,1943 under Recording No.3352228 Northern Pacific Railway Company Railroad tracks (Parcel B)as described therein 12.Easement,Including terms and Recording Information: In Favor of: For: Affects: provisions contained therein: December 2,1943 under Recording No.3352229 Northern Pacific Railway Company,a Wisconsin corporation Construct,maintaining and operating a track connecting (Parcel B)as described therein 13.Easement,including terms and provisions contained therein: Recording Information:August 9,1951 under Recording No.4166571 In Favor of:Renton School District No.403 For:Sewer Affects:(Parcel B)portion of said premises FirstAmerican 7711e Insurance Company Form WA-5 (6/76) Commitment File No.:NCS-339701-WA! Page No,7 14.Easement,including terms and provisions contained therein: Recording Information:July 20,1956 under Recording No.4713420 In Favor of:Renton School District No.403,a municipal corporation For:Sewer Affects:(Parcel B)portion of said premises 15.Easement,including terms and provisions contained therein: Recording information:May 15,1957 under Recording No.4797325 For:Electric transmission line Affects:(Parcel B)portion of said premises 16.Easement,Including terms and provisions contained therein: Recording Information:September 5,1961 under Recording No.5325652 In Favor of:City of Renton,a municipal corporation For:To construct,operate and maintain a public street and highway Affects:(Parcel B)portion of said premises 17.Easement,including terms and provisions contained therein: Recording Information:January 17,1986 under Recording No.8601170666 In Favor of:Puget Sound Power &Light Company,a Washington corporation For:Construct,maintain,repair replace and enlarge guy wires and anchors Affects:(Parcel B)portion of said premises 18.The terms,provisions and easement(s)contained in the document entitled "Recreational Trail Easement and Agreement"recorded September 17,1992 as Recording No.9209171541 of Official Records. (Affects Parcel No.B) 19.The terms and provisions contained in the document entitled Amendment to Bridge Permit, executed by and between Boeing Commercial Airplane Group,a division of The Boeing Company, a Delaware corporation and the City of Renton,a municipal corporation,recorded September 17, 1992 as instrument No.9209171553 of Official Records. (Affects Parcel No.B) 20.The terms and provisions contained in the document entitled Agreement add License for Extension of Boeing Domestic Water and Compressed Air Supply Lines,executed by and between The City of Renton,a municipal corporation and The Boeing Company,by and through its division,Boeing Commercial Airplane Group,recorded February 3,1994 as Instrument No. 9402030678 of Official Records. (Affects Parcel No.B) 21.Covenants,conditions,restrictions and/or easements: Recorded:November 17,2000 FirstAmerican Title Insurance Company Form WA-5 (6/76)Rie No.:NCS-3397Ol-WA1 Commitment Page No.8 22. 23. 24. 25, 26. 27. 28. 29. 30. Recording No.:200011t7000535 Covenants,conditions,restrictions and/or easements: Recorded:November 17,2000 Recording No.:20001117001354 (Affects Parcel No.A) The terms and provisions contained in the document entitled Development Agreement,executed by and between The Boeing Company,a Delaware corporation and The City of Renton,a municipal corporation,recorded August 2,2002 as Instrument No.20020802000224 of Official Records. (Affects Parcel No.A) Easement,including terms and provisions contained therein: Recording Information:Hay 30,2003 under Recording No.20030530001413 In Favor of:Puget Sound Energy,Inc.,a Washington corporation For:Transmission,distribution and sale of electricity Affects:(Parcel B)portion of said premises The terms and provisions contained in the document entitled Development Agreement for Renton Plant Redevelopment,executed by and between The Boeing Company,a Delaware corporation and The City of Renton,a municipal corporation,recorded December lg,2003 as Instrument No.20031210001637 of Official Records. Covenants,conditions,restrictions and/or easements: Recorded:December 28,2004 Recording No.:20041228001871 The terms,provisions and easement(s)contained In the document entitled 'q'emporary Stormwater Facility Easement Agreement"recorded December 28,2004 as Recording No. 20041228001862 of Offidal Records. (Affects Parcel No.B) The terms,provisions and easement(s)contained in the document entitled "Utility Easement Agreement"recorded December 28,2004 as Recording No.20041228001863 of Official Records. (Affects Parcel No.B) The terms,provisions and easement(s)contained in the document entitled "Water Line Easement Agreement"recorded December 28,2004 as Recording No.20041228001864 of Official Records. (Affects Parcel No.B) The terms,provisions and easement(s)contained In the document entitled "Utility Easement Agreement"recorded December 28,2004 as Recording No.20041228001865 of Official Records. FirstAmerican 7"/tie Insurance Company Form WA-5 (5/76) Commitment Rle NO.:NCS-339701-WAI Page No.g (Affects Parcel No.B) 31.The terms,provisions and easement(s)contained in the document entitled 'qemporary Access and Utility Easement Agreement"recorded December 28,2004 as Recording No. 20041228001866 of Official Records. (Affects Parcel No.B) 32.The terms,provisions and easement(s)contained in the document entitled 'q'emparary Stormwater Facility Easement Agreement"recorded December 28,2004 as Recording No. 20041228001867 of Official Records. (Affects Parcel No.B) 33.The terms,provisions and easement(s)contained In the document entitled "Water Line Easement Agreement"recorded December 28,2004 as Recording No.20041228001868 of Official Records. (Affects Parcel No,B) 34.The terms,provisions and easement(s)contained In the document entitled "Water Une Easement Agreement"recorded December 28,2004 as Recording No.20041228001869 of Official Records. (Affects Parcel No.B) 35.The terms,provisions and easement(s)contained in the document entitled 'qemporary Stormwater Facility Easement Agreement"recorded December 28,2004 as Recording No. 20041228001870 of Official Records. (Affects Parcel No.B) 36.Covenants,conditions,restdctions and/or easements: Recorded:December 28,2004 Recording No.:20041228001871 (Affects Parcel No.B) 37.The terms and provisions contained in the do(ument entitled Strander Agreement,executed by and between The Boeing Company,a Delaware corporation and The City of Renton,a municipal corporation,recorded April 20,2006 as Instrument No.20060420001032 of Official Records. 38.Hechanlcs Lien, Claimant: Against: Amount: For: Date Work Commenced: Date Work Ceased: Recorded: Recording No.: G &W Commercial Flooring,Inc. Hillenlum Building $1,326.45 Labor and/or Naterlals and/or Equipment September 26,2007 September 27,2007 December 20,2007 20071220000512 FirstAmerican Title Insurance Company Form WA-5 (6/76)File No.:NCS-339701-WA1 Commitment Page No.10 (Affects Parcel No.B) 39.Mechanics Lien. Claimant: Against: Amount: For: Date Work Commenced: Date Work Ceased: Recorded: Recording No.: Straight Line Striping,Inc. Millennium Building Company,Inc. $4,221.70 Labor and/or Materials and/or Equipment October 1,2007 October 18,2007 January 11,2008 20080111001220 Document(s)declaring modifications thereof recorded January 18,2008 as Recording No. 20080118001094 of Official Records. (Affects Parcel B and other property) 40.Any question as to the true location of the lateral boundaries of the Second Class ride Lands. 41.Rights of the general public to the unrestricted use of all the waters of a navigable body of water not only for the primary purpose of navigation,but also for corollary purposes;including (but not limited to)fishing,boating,bathing,swimming,water skiing and other related recreational purposes,as those waters may affect the tidelands,shorelands or adjoining uplands and whether the level of the water has been raised naturally or artificially to a maintained or fluctuating level, all as further defined by the decisional law of this state.(Affects all of the premises subject to such submergence) 42.Title to vest in an incoming owner whose name Is not disclosed.Such name must be furnished to us so that a name search may be made. 43.Unrecorded leaseholds,if any,rights of vendors and security agreement on personal property and rights of tenants,and secured parties to remove trade fixtures at the expiration of the term. First American T/tie Insurance Company Form WA-5 (6/76)File No.:NCS-339701-WA1 Commitment Page No.11 INFORMATIONAL NOTES A. B, C, D, E. Effective January 1,1997,and pursuant to amendment of Washington State Statutes relating to standardization of recorded documents,the following format and content requirements must be met.Failure to comply may result in rejection of the document by the recorder. Any sketch attached hereto is done so as a courtesy only and is not part of any title commitment or policy.It is furnished solely for the purpose of assisting in locating the premises and First American expressly disclaims any liability which may result from reliance made upon it. if this preliminary report/commitment was prepared based upon an application for a policy of title insurance that identified land by street address or assessor's parcel number only,it is the responsibility of the applicant to determine whether the land referred to herein is in fact the land that is to be described in the policy or policies to be issued. The description can be abbreviated as suggested below if necessary to meet standardization requirements.The full text of the description must appear in the document(s)to be insured. Ptn Sec 5 Twp 23N Rge OSE,SW Qtr,Ptn Sec 6 Twp 23N Rge 05E,SE Qtr,Ptn Sec 7,Twp 23N Rge 05E and Ptn Sec 8 Twp 23N Rge 05E,NW Qtr APN:072305-9046-08 APN:072305-9001-01 A fee will be charged upon the cancellation of this Commitment pursuanttethe Washington State InsunceCode and the filed RateSchedule ofthe Company. END OF SCHEDULE B First American T/tie Insurance Company ,.;If#if|:i.);"........., WARRANTY DEED plpni.Zll mtl*I'nlPm $tlpm'-Jox't 15enpiem ,rod l+J,,,+e+l,P [+NOW AtJME/Br THEY pHF.T%VPnl t'Ilrml,.%4t To;}tL n ?-1"-3 . -',-"i •rorilhiilclllilitllmoftheliin,,'f ............,;••.--:.. ,V=lbouimxllld o/lO0-(4=O00;qO}-:..................g'l •v '--IFSI .#limlpo,lo.w -.........--'........... on .elt4i'13 nldll of )le llll.r liqo .if ll,liid h4l.*,S .a ur +:1 ,'+r a,ld zl'' -,.,,o •;nlrnr OJ+(lols-ulont hot ?L uiti 'ctzon ?l-.l.'lb th "*4 'l'lj%.r.*li-i "a ?f*t or*[*'ll Hgr.ho ItorlJ ,.l"bn of lntd i'-,i%,,.'rl+t ",'*'.,t.","et.;,"-'r]"*!qy lr++pP,o"I+:{I180P60O<:"I fOLov+l bGIt3+LL.L,.+*.hO t+rftCL+>,p or Lfi*¢0 .*•:"t..'i :e t¢t tl.,81.,lllleaelillrl.a,,tllin or .i+no "i.£.m=*.tll rl.il,,,J..n.in ;t ri i.r*•""..-1 "ttwl ut 055127"[oo 15 .4 feet t,.a =l'ou *.he }-,".qr'.:..t,r",i eo ,:-.,. fl D!.I¢¢lio*t rZdht of nalthenew orLh 1$,*,'b"*'.t 1o,I G ti '';'s-n of ln illn,rht of way)2119,fetl Lhgnev Orth ""*i)i;'i',i.J )'."";,'%1 i'Jlin OL'amAd ZInIeT tr.t tOl(ke,t of inntn"". '.-11 sSFir of ei hePo+bet'1 I:mlv3ed*coucattoj 4,4J ,r.'itur.or L •r Gi"di+....:J.........,,..........Ip llll ¢onl'lpl n+ltt ,iLl ,,I .i,,h *,ill ,,[it I.lind +,'1,it th.I l,i Ill I 'nr.p.i[iI"'.......'"" rllr .irordlnillln hh i,ill*l,l'l,,,r li,,i*+-ll,el,#}|I),I.a it l)l>l.I Ii,.: u,mi ArJ.,I,.t,lei2 "•,,.,v rln1ll.ll lialin ro=ore ..h "rh?,to reo+4 rrovont5 t'roe th,1.4s -'.'" [:i$*dz|ii M iliLJ.llbLiittea io ro=ld/o£,robertT coani,t-d ;ith *it ",,J,,.* m,if ,th .".._da om duf,n"hePoofihOnller,t .ez'z,t.in nt""L*?0 ,, ii,tIXll 4mp,gveioT.fl Otp tea%4 UbOiI O rtal lipol=*ld lnde ,h,ll -:,,.-*PiPi or 01,41141 of Washington id i Pbto of i,he Grantr hor,ILn to i .i'i"•,v*- ,=:untg,=zgvnt,d bu|,ha ,,l'll',,+l ,,'li,,,l ,,I,rr,.,d ,,+i,lZl'lzcl+l,l,l.,,'.',, _rllllillU&lllllidlu,,lu,,,l<.+i +.d ,Ip*,,,r++*,,n,i ,i,',;I.*tk,-h .+t I'n •.m,+im+m oi ,sl?.,.....i+i •w,........ lh,lld'lhki.,liUl d=$,it Jl.v 1'i4 ,tTATI OIAIII+C,TO, .-:<...:":..>,P+..+..?++J..-.....:.•.it,oil,pr ltl l'+mre."_".:,.,+ •i ";.......,.,,.:...*'..-;,t, Lt .qL.__.,.oF I ..,'_.. •D Forn WA-5 (6/76) Commitment •File No.:NCS-339701-WA1 Page No.12 1, 2. , 4. FirstAmerican Title Insurance Company National Cornrnerc/a/Services COMMITMENT Conditions and Stipulations The term "mortgage"when used herein shall include deed of trust,trust deed,or other security instrument. If the proposed Insured has or acquires actual knowledge of a defect,lien,encumbrance, adverse claim or other matter affecting the estate or interest or mortgage thereon covered by this Commitment,other than those shown in Schedule B hereof,and shall fail to disclose such knowledge to the Company in writing,the Company shall be relieved from liability for any loss or damage resulting from any act or reliance hereon to the extent the Company is prejudiced by failure to so disclose such knowledge.If the proposed [nsured shall disclosure such knowledge to the Company,or if the Company otherwise acquires actual knowledge of any such defect,lien, encumbrance,adverse claim or other matter,the Company at its option,may amend Schedule B of this Commitment accordingly,but such amendment shall not relieve the Company from liability previously incurred pursuant to paragraph 3 of these Conditions and Stipulations. Liability of the Company under this Commitment shall be only to the named proposed ]nsured and such parties Included under the definition of Insured in the form of Policy or Policies committed for,and only for actual loss Incurred In reliance hereon In undertaking in good faith (a)to comply with the requirements hereof,or (b)to eliminate exceptions shown in Schedule B, or (c)to acquire or create the estate or interest or mortgage thereon covered by this Commitment.In no event shall such liability exceed the amount stated in Schedule A for the Policy or Policies committed for and such liability is subject to the Insuring provisions,exclusion from coverage,and the Conditions and Stipulations of the form of Policy or Policies committed for In favor of the proposed Insured which are hereby incorporated by references,and are made a part of this Commitment except as expressly modified herein. Any claim of loss or damage,whether or not based on negligence,and which arises out of the status of the title to the estate or interest or the lien of the Insured mortgage covered hereby or any action asserting such claim,shall be restricted to the provisions and Conditions and Stipulations of this Commitment. First American Title Insurance Company Form WA-$(6/76) Commitment RIo No.:NCS-339701-WA1 Page No.13 The Flnit American Corporation FirstAmerican Title insurance Company National CommercialServices PRIVACY POLICY We Are Committed to Safeguarding Customer ]nformaUon In order to Potter serve your needs new and in the future,we may ask you to provide us with certain information.We understand that you may be concerned about what we will do with such Information particularly any personal or financial information.We agree that you have a dght to know how we will utilize the personal Information you provide to us.Therefore,together with our parent company,The First American Corporation,we haveadoptedthisPrivacyPolicytogoverntheuseandhandlingofyourpersonalinformation. Applicability This Pflvecy Policy governs our use of the information which you provide to us.it does not govern the manner in which we may use information wehaveobtainedfromanyothersource,such as information obtained from a public r-ord or from another person or eetity.First American has aJse adopted broader guidelines that govern our use of personal information rogardlees of Its source.First Americon cafls these guidelines its Fair Information Values,a copy of which can be found on our webslte at www.flrstam.corn. Types of Information Depending upon which of our services you are utilizing,the types of nonpubllc personal Information that we may collect Include: information we receive from you on applications,farms and In other communications to us,whether In writing,in person,bytelephoneoranyothermeans; •Information about your transactions with us,our affiliated companies,or others;and' •InformaUon we receive from a consumer reporting agency. USe of Information We request Informotlon from you for our own legitimate business purposes and not for the benefit of any nonaffiliated party.Therefore,we will notreleaseyourinformationtononaffiliatedpartiesexcept:(t)as necessary for us to provide the product or service you have requested of us;or (2)aspermittedbylaw.We may,however,store such Information indefinitely,including the period aft:or which any customer relationship has ceased.Such information may be used for any Internal purpose,such as quality control efforts or customer analysis.We may else provide all of the types ofnonpublicpersonalInformationlistedabovetooneormoreofouraffllatedcompanies.Such affiliated companies include financial service providers,such as title insurers,property and casualty insurers,and trust and Investent advisory companies,or companies InvoLved in real estate services,such as appraisal companies,home warrant,/companies,and escrow companies.Furthermore,we may also provide all the Information we colfect,as described above,to companies that perform marketing services on our behalf,on behalf of our affiliated companies,or to other financial institutions with whom we or our afflietad companies have Joint marketing agreements. ormor Cuel;omors Even If you are no longer our customer,our Privacy Policy will continue to apply to you. Confidentiality and Security We will use our best efforts to ensure that no unauthorized parties have access to any of your information.We restrict access to nonpublic personalinformationaboutyoutotheseindividualsendentitieswhoneedtoknowthatinformationtoprovideproductsorservicestoyou.We will use our besteffortstotrainandoverseeouremployeesandagentstoensurethatyourInformationwillbehandledresponsiblyandinaccordancewiththisPdvacyPolicyandFirstAmerican's Fair Information Values.We correnby maintain physical,eleetronlc,and procedural safeguards that comply with federal regulations to guard your nonpubllc personal information. c 200)The First American Corporation -All Rights Reserved FirstAmerican Title Insurance Company "& W\ Printed:03-13-2008 Payment Made: Total Payment: CLEMENT CITY OF RENTON 1055 S.Grady Way Renton,WA 98055 ,oPMENT pLh,tNNGOEVE.OF RENTON Land Use Actions RECEIPT Permit#:LUA08-022 03/13/2008 01:02 PM 1,000.00 1 3 Receipt Number:R0801204 Payee:TO BE BILLED TO BOEING/MARK Currant Payment Made to the Following Items: Trans Account Code Description 5010 000.345.81.00.0007 Environmental Review Amount 1,000.00 Payments made for this receipt Trans Method Description Amount ............................................................. Payment BILL 96327 1,000.00 Account Balances Trans Account Code ........................ 3021 303.000.00.345.85 5006 000.345.81.00.0002 5007 000.345.81.00.0003 5008 000.345.81.00.0004 5009 000.345.81.00.0006 5010 000.345.81.00.0007 5011 000.345.81.00.0008 5012 000.345.81.00.0009 5013 000.345.81.00.0010 5014 000.345.81.00.0011 5015 000.345.81.00.0012 5016 000.345.81.00.0013 5017 000.345.81.00.0014 5018 000.345.81.00.0015 5019 000.345.81.00.0016 5020 000.345.81.00.0017 5021 000.345.81.00.0018 5022 000.345.81.00.0019 5024 000.345.81.00.0024 5036 000.345.81.00.0005 5909 000.341.60.00.0024 5941 000.341.50.00.0000 5954 650.237.00.00.0000 5955 000.05.519.90.42.1 5998 000.231.70.00.0000 Description Balance Due ............................................. Park Mitigation Fee Punnexation Fees Appeals/Waivers Binding Site/Short Plat Conditional Use Fees Environmental Review Prelim/Tentative Plat Final Plat PUD Grading &Filling Fees Lot Line Adjustment Mobile Home Parks Rezone Routine Vegetation Mgmt Shoreline Subst Dev Site Plan Approval Temp Use,Hobbyk,Fence Variance Fees Conditional Approval Fee Comprehensive Plan Amend Booklet s/EIS/Copies Maps (Taxable) Special Deposits Postage Tax ,00 .00 ,00 ,00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 Remaining Balance Due:$0.00 CITY OF RENTON 1055 S.Grady WayRenton,WA 98055 Printed:03-13-2008 Land Use Actions RECEIPT Payment Made: Total Payment: CLEMENT Permit#:LUA08-022 03/13/2008 01:03 PM Receipt Number:R0801205 500.00 Payee:TO BE BILLED TO BOEING/MARK Current Payment Made to the Following Items: Trans Account Code Description Amount ...................................................................... 5020 000,345.81.00.0017 Site Plan Approval 500.00 Payments made for this receipt Trans Method Description Amount ............................................................ Payment BILL 96327 500.00 Account Balances Trans Account Code ........................ 3021 303.000.00,345.85 5006 000.345.81.00.0002 5007 000.345.81.00.0003 5008 000.345.81.00.0004 9009 000,345.81.00.0006 5010 000.345.81.00.0007 5011 000,345.81.00.0008 5012 000.345.81.00.0009 5013 000.345.81.00.0010 5014 000.345.81.00.0011 5015 000.345.81.00.0012 5016 000.345.81.00.0013 5017 000.345.81.00.0014 5018 000.345.81.00.0015 5019 000.345.81.00.0016 5020 000.345.81.00.0017 5021 000.345.81.00.0018 5022 000.345.81.00.0019 5024 000.345.81.00.0024 5036 000.345.81.00.0005 5909 000.341.60.00.0024 5941 000.341.50.00.0000 5954 650.237,00.00.0000 5955 000.05.519.90.42.1 5998 000.231.70.00.0000 Description Balance Due ............................................. Park Mitigation Fee Annexation Fees Appeals/Waivers Binding Site/Short Plat Conditional Use Fees Environmental Review Prelim/Tentative Plat Final Plat PUD Grading &Filling Fees Lot Line Adjustment Mobile Home Parks Rezone Routine Vegetation Mt Shoreline Subst Dev Site Plan Approval Temp Use,Hobbyk,Fence Variance Fees Conditional Approval Fee Comprehensive Plan Amend Booklets/EIS/Copies Maps (Taxable) Special Deposits Postage Tax .00 .00 .00 .00 ,00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 ,00 Remaining Balance Due:$0.00