Loading...
HomeMy WebLinkAboutCouncil 09/20/2010AGENDA  RENTON CITY COUNCIL    REGULAR MEETING  September 20, 2010  Monday, 7 p.m.  1.CALL TO ORDER AND PLEDGE OF ALLEGIANCE 2.ROLL CALL 3.PROCLAMATION a. Mayor's Day of Concern for the Hungry ‐ September 25, 2010  4.SPECIAL PRESENTATIONS a. 4th of July Wrap‐Up  b. IKEA Renton River Days Wrap‐Up  5.ADMINISTRATIVE REPORT 6.AUDIENCE COMMENT (Speakers must sign up prior to the Council meeting.  Each speaker is allowed five minutes.  The  comment period will be limited to one‐half hour.  The second audience comment period later on in  the agenda is unlimited in duration.)  When you are recognized by the Presiding Officer, please  walk to the podium and state your name and city of residence for the record, SPELLING YOUR LAST  NAME. 7.CONSENT AGENDA The following items are distributed to Councilmembers in advance for study and review, and the  recommended actions will be accepted in a single motion.  Any item may be removed for further  discussion if requested by a Councilmember.  a. Mayor Law appoints Amy Pieper to the Library Advisory Board, for an unexpired term expiring  9/1/2014 (position previously held by Jason Oleston). Refer to Community Services Committee.  b. Mayor Law appoints Richard Siers to the Airport Advisory Committee, Highlands Neighborhood  primary position, for an unexpired term expiring 5/7/2013 (position previously held by Michael  O'Halloran). Refer to Community Services Committee.  c. City  Clerk  reports  bid  opening  on  8/24/2010  for  CAG‐10‐087,  Stonegate  Lift  Station  Replacement; 14 bids; engineer’s estimate $1,404,019.95; and submits staff recommendation  to  award  the  contract  to  the  low  bidder,  Shoreline  Construction,  Co.,  in  the  amount  of  $1,213,270. Refer to Utilities Committee for discussion of funding.  d. City Clerk submits request for partial release of Easement for Slopes by Hal Grubb, Barghausen  Engineers, 18215 72nd Ave. S., Kent, 98032 for approximately 3,729 square feet of property  located on the north side of SE Carr Rd., at 10436 SE Carr Rd., in the vicinity west of 108th Ave.  SE (SR 515) and east of Talbot Rd. S.  Refer to Transportation (Aviation) Committee.  Page 1 of 146 e. Community  and  Economic  Development  Department  recommends  amending  City  Code  to  adopt legislative changes regarding appeal provisions.  Refer to Planning and Development  Committee.  f. Community Services Department recommends approval of the revised 2010 and the 2011/2012  Community  Development  Block  Grant  Human  Services  funding  allocations  and  Contingency  Funding Plan. Refer to Finance Committee.  g. Community Services Department recommends approval of the 2011/2012 General Fund Human  Services funding allocation recommendations and Contingency Funding Plan. Refer to Finance  Committee.  h. Transportation Systems Division recommends rescinding the termination of CAG‐08‐194, with  King County Transit, and approval of an addendum in the amount of $199,743.57 per year  (beginning in 2013), to provide enhanced service and routing on Metro Route 110.  Council  concur.  (See 9.a. for resolution.)  i. Utility  Systems  Division  requests  authorization  to  finalize the  126th  Ave.  SE  Sanitary  Sewer  Extension  Special  Assessment  District  in  the  estimated  amount  of  $347,455.53.  Refer  to  Utilities Committee.  j. Utility  Systems  Division  submits  proposed  changes  to  the  water,  wastewater,  and  surface  water utility rates. Refer to Committee of the Whole.  k. Utility Systems Division recommends assuming maintenance and operation of all stormwater  facilities  in  single‐family  residential  plats  with  public  streets.   Refer  to Committee  of  the  Whole.  l. Utility Systems Division recommends approval to accept $297,940 in non‐matching grant funds  from  the  Department  of  Ecology  to  implement  requirements  associated  with  the  National  Pollutant  &  Discharge  Elimination  System  (NPDES)  Phase  II  Municipal  Stormwater  permit.   Council concur.  8.UNFINISHED BUSINESS Topics listed below were discussed in Council committees during the past week.  Those topics  marked with an asterisk (*) may include legislation.  Committee reports on any topics may be held  by the Chair if further review is necessary. a. Public Safety Committee:  Feeding Dangerous Wildlife  9.RESOLUTIONS AND ORDINANCES Resolution: a. Route 110 service partnership agreement with King County Transit (See 7.h.)  10.NEW BUSINESS (Includes Council Committee agenda topics; call 425‐430‐6512 for recorded information.) 11.AUDIENCE COMMENT 12.ADJOURNMENT           Page 2 of 146   COMMITTEE OF THE WHOLE AGENDA   (Preceding Council Meeting)     7TH FLOOR CONFERENCING CENTER  September 20, 2010  Monday, 6:00 p.m.     Regional Issues (Rail, I‐405 Tolling, November Ballot Issues)    • Hearing assistance devices for use in the Council Chambers are available upon request to the City Clerk •     CITY COUNCIL MEETINGS ARE TELEVISED LIVE ON GOVERNMENT ACCESS CHANNEL 21 AND ARE RECABLECAST:  Tues. & Thurs. at 11 AM & 9 PM, Wed. & Fri at 9 AM & 7 PM and Sat. & Sun. at 1 PM & 9 PM  Page 3 of 146 3a. ‐ Mayor's Day of Concern for the Hungry ‐ September 25, 2010 Page 4 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: Appointment to the Library Advisory Board Meeting: Regular Council - 20 Sep 2010 Exhibits: Application for Boards/Commissions/Committees Submitting Data: Dept/Div/Board: Executive Staff Contact: Denis Law, Mayor Recommended Action: Refer to Community Services Committee Fiscal Impact: Expenditure Required: $ N/A Transfer Amendment: $N/A Amount Budgeted: $ N/A Revenue Generated: $N/A Total Project Budget: $ N/A City Share Total Project: $ N/A SUMMARY OF ACTION: Mayor Law appoints the following to the Library Advisory Board: Ms. Amy Pieper, 264 Earlington Avenue NW, Renton, WA 98057, for a term expiring September 1, 2014 (position previously held by Jason Oleston). STAFF RECOMMENDATION: Confirm Mayor Law's appointment of Ms. Pieper to the Library Advisory Board 7a. ‐ Mayor Law appoints Amy Pieper to the Library Advisory Board, for  an unexpired term expiring 9/1/2014 (position previously held by Jason Page 5 of 146 7a. ‐ Mayor Law appoints Amy Pieper to the Library Advisory Board, for  an unexpired term expiring 9/1/2014 (position previously held by Jason Page 6 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: Appointment to Airport Advisory Board: Richard Siers Meeting: Regular Council - 20 Sep 2010 Exhibits: Application for Boards, Commissions, Committees Submitting Data: Dept/Div/Board: Executive Staff Contact: Denis Law, Mayor Recommended Action: Refer to Community Services Committee Fiscal Impact: Expenditure Required: $ N/A Transfer Amendment: $N/A Amount Budgeted: $ N/A Revenue Generated: $N/A Total Project Budget: $ N/A City Share Total Project: $ N/A SUMMARY OF ACTION: Mayor Law appoints the following to the Airport Advisory Committee: Richard Siers, 4706 NE 1st Court, Renton, WA 98059 (Highlands Neighborhood primary position), for a term expiring May 7, 2013 (position previously held by Michael O'Halloran). STAFF RECOMMENDATION: Confirm Mayor Law's appointment of Mr. Siers to the Airport Advisory Committee. 7b. ‐ Mayor Law appoints Richard Siers to the Airport Advisory  Committee, Highlands Neighborhood primary position, for an unexpired Page 7 of 146 7b. ‐ Mayor Law appoints Richard Siers to the Airport Advisory  Committee, Highlands Neighborhood primary position, for an unexpired Page 8 of 146 7b. ‐ Mayor Law appoints Richard Siers to the Airport Advisory  Committee, Highlands Neighborhood primary position, for an unexpired Page 9 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: Bid opening on August 24, 2010 for CAG-10-087, Stonegate Lift Station Replacement Meeting: Regular Council - 20 Sep 2010 Exhibits: Staff Recommendation Bid Tab (14 bids) Submitting Data: Dept/Div/Board: Executive Staff Contact: Bonnie I. Walton, City Clerk, x6502 Recommended Action: Refer to Utilities Committee Fiscal Impact: Expenditure Required: $ $1,213,270 Transfer Amendment: $ Amount Budgeted: $ Revenue Generated: $ Total Project Budget: $ $2,700,000 (2010 & 2011)City Share Total Project: $ SUMMARY OF ACTION: Engineer's Estimate: $1,404,019.95 In accordance with Council procedure, bids submitted at the subject bid opening met the following criteria: There was more than one bid, the were no significant irregularities with the low bid, and the bid is within the budgeted amount for the project for 2010 and proposed 2011. Due to prior phase work for this project, award of this contract requires approval of the 2011 proposed budget amount of $1.4 million. Therefore, staff recommends acceptance of the low bid submitted by Shoreline Construction Co. in the amount of $1,213,270 and refer the issue to the Utilities Committee for discussion of funding. STAFF RECOMMENDATION: Accept the low bid submitted by Shoreline Construction Co. in the amount of $1,213,270 and approve the proposed $1.4 million funding for 2011. 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 10 of 146 PUBLIC WORKS DEPARTMENT DATE: TO: FROM: SUBJECT: MEMORANDUM September 2, 2010 Bonnie Walton, City Clerk SEP 0 2 2010 ') A„. RECEIVED John Hobson, Wastewater Utility Engineer, x7279 tA/T CLERK'S OFFICE Bid Award for Stonegate Lift Station Replacement Project The Public Works Department has reviewed the bids submitted for the Stonegate Lift Station Replacement project and recommends that the bid be awarded to Shoreline Construction Co. We are requesting that an agenda bill for "Refer to Utilities Committee" be prepared for the September 20, 2010, Council Meeting. The bid opening was on Tuesday, August 24, 2010. There were 14 bids received. There were math errors in three bids: Contractor Western Engineering Contractors Boss Construction, Inc. McClure and Sons, Inc. Original Bid $1,450,458.90 $1,473,213.00 $1,582,023.00 Corrected Bid $1,432,938.90 $1,520,007.83 $1,559,028.15 Original Bid Placing 7th 9th 12th Revised Bid Placing 6th llth 12th The low bidder is Shoreline Construction Co. with a bid of $1,213,270. The engineer's estimate was $1,404,019.95. The project budget amounts are $1,300,000 (2010) and $1,400,000 (2011). The 2010 budget amount also includes funds for the Stonegate Lift Station Conveyance Improvement project (projected completion date September, 2010) which will require $875,888.86 of the $1,300,000. The low bid is within the amount budgeted for the combined 2010/2011 budget for this project. The project will build a new, larger Stonegate sanitary sewer lift station to replace the existing undersized Stonegate and Summerwind lift stations. Attachments cc: Gregg Zimmerman, PW Administrator Lys Hornsby, Utility Systems Director Dave Christensen, Wastewater Utility Supervisor H:\File Sys\WWP - WasteWater\WWP-27-3473 Summerwind-Stonegate LS Replacement\CONSTRUCTION\Lift Station\Contract lnfo\Award-Clerk-Stonegate Replacement.doc\JDHtp 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 11 of 146 Project Title:Stonegate Lift Station Replacement BIDfJATE: August 24, 2010 E Item r< No. Description Unit Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum ;Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum Est. Quantity 1 1 1 1 100 450 50 1 150 130 . 200 1 55 150 25 2 1. 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 City of Renton Engineers Estimate Unit Price $91,000.00 $5,000.00 $5,000.00 $10,000.00 $12.00 $15.00 $15.00 $40,000.00 $15.00 $15.00 $40.00 $10,000.00 $45.00 $50.00 $50,00 $2,000.00 $3,000.00 $5,000.00 $4,500.00 $1,000.00 $50.00 $60.00 $70.00 $2.00 $70.00 $5,000.00 $30,000.00 $25.00 $45.00 $50.00 $45.00 $2,500.00 $50.00 $25.00 $1,000.00 $45.00 $500.00 $5,000.00 $40,000.00 $70,000.00 $50,000.00 $65,000.00 $120,000.00 $35,000.00 $93,000.00 $25,000.00 $45,000.00 $6,000.00 $7,500.00 $115,000.00 $90,000.00 $45,000.00 $125,000.00 $12,500.00 $12.00 $10,000.00 $15,000.00 Subtotal Tax 9.5% Bid Amount 91,000.00 5,000.00 5,000.00 10,000.00 1,200.00 6,750.00 750.00 40,000.00 2,250.00 1,950.00 8,000.00 10,000.00 2,475.00 7,500.00 1,250.00 4,000.00 3,000.00 5,000.00 4,500.00 1,000.00 2,500.00 5,100.00 2,800.00 710.00 7,700.00 5,000.00 30,000.00 625.00 4,050.00 1,000.00 11,475.00 2,500.00 2,500.00 1,375.00 1,000.00 4,050.00 2,000.00 5,000.00 40,000.00 70,000.00 50,000.00 65,000.00 120,000.00 35,000.00 93,000.00 25,000.00 45,000.00 6,000.00 7,500.00 115,000.00 90,000.00 45,000.00 125,000.00 12,500.00 13,200.00 10,000.00 15,000.00 $1,282,210.00 $121,809.95 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 6-Inch Diam. PVC Storm Sewer Pipe 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 Oil/Water Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe 24 Televison Inspection 25 8-lnch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 • Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Total $1,404,019.95 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 12 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item h No. Unit Description Est. Quantity ^Shoreline,Construction Cd..: liriciS ;:;;:;Bjdj|l ; Amount 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 6-Inch Diam. PVC Storm Sewer Pipe 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 Oil/Water Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe 24 Televison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam.. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work' 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 . 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 li;20,OPO;00 ; lil|!,56b.66' |||o;fbbjbo>: IllfbobSg-; H!IS:;Vr:bbf |;;llK;ii;bb2 !;f|j|l5.bbl ;!::22lpbb:pb;| HMI-bb:: IjllSKbp:^ ||;i:b;!bbl:pb^ iffilllp-bbs lliillslbbl; illli^ejbb;;: llllfsbbjoo:;:: liSiibSbb;;- lllilboM- lSi!3lob:pp^ |, • ?;2,i2ob7boi;- ::|!l3'5;baf .,-;.. |Sii6a;bb:;: M'SfWMU: :'Sji|g5jbbJ} |:u5,bqbiQ;;5: |S|f,pbb1Sffi: :|i:;|::!:25jbl:! |liftj75:Q9;:; jglllpiob ; :l::;j|fp|Sb Jifm|gg::':: |::|||||)ffi::; 1, ^,3ppio| f;5,raQ;pb:::; W3b,gpb1bb/ i:25;0pp;bb;; l:4b,op(|bb:i ||75,&iPP;;: ||§5,qob!bb' @35,bbb;bo^ PimJmM' v^Cpppibii! i;;i8,b1p6oG j||5;bbbSbp| jlli,ipbb;p(il ;|M,pob;bb:j ;|pb,bbb;pb;: S|4',bbb;00;:: |^3P,pbp;bp^ If i's.oSovod e iSllllKI ?f|SbbpJbb;| l||Subtpt|lI ™Ifax^sil j:^2p;ooo.pp; tlfllbbpSp' :|:::3bvbpb.bbi 'I;;i:f5llpp;bb; fiibbSb: M;:;::n!ibBp: fs^ibJop ::i|p22^oo6:bb ::Ia:i,65p::bb ::|a;i,43p:bb ;:fi:9;6baoa ;-:|:!b;boo.p6- i:;:j2y2oo:ob; MSJ5O.0 :'• ^650.00 i \ ;3,600.00 :i i;-2;lbb;00 ;{ ;;;:|-4pP;p0 ': \i:p;bbp!b0i ::v • ;:2^2bb;bb :Ci:f6,6bb;pP: •£ff,4J$.00" l:;l6,72b;D0 :;l;Eb65.00 IPgsabo fysjpbaob Irlljbbblbb: : f 1625.00: • €170.00; ; -1^500.00 -p 71650.00 ifvi^ob.oo; :;::;j2,00b;0b ||I3;;375^0; fffSbq.00 :-:: jflqpipp: |:::i5;bob;bb }||3b;066"00; :|:25;poo,bo: l;§3;opo;po ;:;:v|5]QQ0;pb i:;:65;obb:pb ;=i 35 ^oopTSd :::;;:7b;obb;bb; :;:22,00b:pb u;i8,opb.bo a :5,000X10 f;;;5lopb;bb /riS;bbb;bo ;;iob^pbipo |;i4;bbb|jb tl3p,bbb.;ob ;::i:|,bob:bb |/;;|,ibp;oo IJllJpJbJbo l||;i)p.bo ;::;$1,f08,piP.OO: ::|^1Q5i2§0.95. iTotali: ;$1,213,270.95 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 13 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item h- No. Unit Description Est. Quantity Plats Plus Inc. Unit Price Bid Amount 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 6-Inch Diam. PVC Storm Sewer Pipe 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 OilAA/ater Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe 24 Televison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard. 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 87,000.00 1,500.00 5,000.00 4,700.00 30.00 21.00 28.00 1,000.00 25.00 26.00 100.00 60,000.00 23.00 27.00' 51.00 890.00 1,050.00 4,300.00 8.800.0P 1.4P0.00 100.00 185.00 210.00 2.00 69.00 4,700.00 14,000.00 10.00 23.00 75.00 30.00 1,100.00 45.00 45.00 2,200.00 35.00 250.00 6,000.00 9,000.00 6,000.00 20,000.00 95,000.00 170,000.00 54,000.00 74,000.00 20.PPP.00 •15,000.00 2,500.00 3,000.00 117.0PP.P0 103,000.00 13,000.00 119,000.00 2,000.00 20.00 8,000.00 8,000.00 87,000.00 1,500.00 5,000.00 4,700.00 3,000.00 9,450.00 1,400.00 1,000.00 3,750.00 3,380.00 20,000.00 60.PP0.00 1,265.00 4,050.00 1,275.00 1,780.00 1,050.00 4,300.00 8,800.00 1,400.00 5,000.00 15,725.00 8,400.00 710.00 7,590.00 4.700.PO 14,000.00 250.00 2,070.00 1,500.00 7,650.00 1,100.00 2,250.00 2,475.00 2,200.00 3,150.00 1,000.00 6,000.00 9,000.00 6,000.00 20,000.00 95,000.00 170,000.00 . 54.000.0P 74.PP0.0P 20,000.00 15,000.00 2,500.00 3,000.00 117,000.00 103,000.00 13,000.00 119,000.00 2,000.00 22,000.00 8,000.00 8,000.00 Subtotal $1,170,370.00 Tax 9.5% $111,185.15 Total $1,281,555.15 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 14 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item h No. Unit Description Est. Quantity Massana Construction Inc. Unit Price Bid Amount 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 " Facility Coatings 13 6-Inch Diam. PVC Storm Sewer Pipe 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 OilAA/ater Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-Inch Diam. PVC C9PP Gravity Sewer Pipe 24 Televison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 70,500.00 2,000.00 20,000.00 10,000.00 50.00 22.00 30.PO 2,000.00 32.00 30,00 95.00 60,000.00 35.00 35.00 60.00 1,300.00 1,300.00 2,400.00 5,000.00 8,000.00 100.00 90.00 280.00 2.00 65.00 30,000.00 12,000.00 30.00 31.00 73.00 20.00 1,000.00 50.PP 30.00 1,000.00 18.00 400.00 2,500.00 40,000.00 50,00P.O0 20,000.00 65,000.00 115,000.00 20,000.00 91,000.00 45,000.00 30,000.00 3,000.00 2,000.00 110.P00.00 92,000.00 20,000:00 120,000.00 2,000.00 20.00 10,000.00 10.000.0P 70,500.00 2,000.00 20,000.00 10,000.00 5,000.00 9,900.00 1,500.00 2,000.00 4,800.00 3,900.00 19,000.00 60,000.00 1,925.00 5,250.00 1,500.00 2,600.00 1,300.00 2,400.00 5,000.00 8,000.00 5,000.00 7,650.00 11,200.00 710.00 7,150.00 30,000.00 12,000.00 750.00 2,790.00 1,460.00 5,100.00 1,000.00 2,500.00 1,650.00 1,000.00 1,620.00 1,600.00 2,500.00 40,000.00 50.PPO.00 20,000.00 65,000.00 115,000.00 20,000.00 91,000.00 45,000.00 30,000.00 3,000.00 2,000.00 110,000.00 92,000.00 20,000.00 120,000.00 2,000.00 22,000.00 10,000.00 10,000.00 Subtotal $1,199,255.00 Tax 9.5% $113,929.23 Total $1,313,184.23 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 15 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item r> No. Unit Description Est. Quantity R. L. Alia Company Unit Price Bid Amount 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 6-Inch Diam. PVC Storm Sewer Pipe 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 Oil/Water Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe 24 Televison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 • 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 35,000.00 2,500.00 1,000.00 7,500.00 40.00 15.00 20.00 35,000.00 20.00 20.00 140.25 10,000.00 328.00 150.00 498.40 1,000.00 2,000.00 5,000.00 5,000.00 5.000.PP 60.00 70.00 100.00 25.00 100.00 3,900.00 12,750.00 25.00 32.00 73.00 25.00 2,025.00 50.00 20.00 1,250.00 100.00 250.00 22.000.0P 20,000.00 1,000.00 30,000.00 120,000.00 120,000.00 35,000.00 23;954.00 50,000.00 40,000.00 15,000.00 50,000.00 106,500.00 110.0P0.00 6,800.00 116,000.00 10,000.00 15.00 40,000.00 40,000.00 35,000.00 2,500.00 1,000.00 7,500.00 4,000.00 6,750.00 1,000.00 35,000.00 3,000.00 2,600.00 28,050.00 10,000.00 18,040.00 22,500.00 12,460.00 2,000.00 2,000.00 5,000.00 5,000.00 5,000.00 3,000.00 5,950.00 4,000.00 8,875.00 11,000.00 3,900.00 12,750.00 625.00 2,880.00 1,460.00 6,375.00 2,025.00 2,500.00 1,100.00 1,250.00 9,000.00 1,000.00 22,000.00 20,000.00 1,000.00 30,000.00 120,000.00 120,POO.00 35,000.00 23,954.00 50,000.00 40,000.00 15,000.00 50,000.00 106,500.00 110.000.0P 6,800.00 116,000.00 10,000.00 16,500.00 40,000.00 40,000.00 Subtotal $1,258,844.00 Tax 9.5% $119,590.18 Total $1,378,434.18 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 16 of 146 Project Titie:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item r- No. Unit Description Est. Quantity Ceccanti Unit Price Bid Amount 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 6-Inch Diam. PVC Storm Sewer Pipe 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 OilAA/ater Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe 24 Televison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls. 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1' 1 1 1 1 1,100 1 1 50,000.00 500.00 1,000.00 15,000.00 10.00 14.00 14.00 50,000.00 20.00 20.00 100.00 75,000.00 40.00 42.00 50.00 1,100.00 1,200.00 5,300.00 5,300.00 2,000.00 60.00 65.00 70.00 5.00 55.00 5,500.00 15,000.00 25.00 40.00 100.00 30.00 1,200.00 55.00 21.39 1,300.00 20.00 350.00 50,000.00 90,000.00 50,000.00 80,000.00 60,000.00 90,000.00 20,000.00 50,000.00 62,000.00 1,000.00 3,800.00 12,000.00 125,000.00 120,000.00 15,000.00 100,000.00 2,000.00 1.00 10,000.00 10,000.00 50,000.00 500.00 1,000.00' 15,000.00 1,000.00 6,300.00 700.00 50,000.00 3,000.00 2,600.00 20,000.00 75,000.00 2,200.00 6,300.00 1,250.00 2,200.00 1,200.00 5,300.00 5,300.00 2,000.00 3,000.00 5,525.00 2,800.00 1,775.00 6,050.00 5,500.00 15,000.00 625.00 3,600.00 2,000.00 7,650.00 1,200.00 2,750.00 1,176.45 1,300.00 1,800.00 1,400.00 50,000.00 90,000.00 50,000.00 80,000.00 60,000.00 90,000.00 20,000.00 50,000.00 62,000.00 1,000.00 3,800.00 12,000.00 125,000.00 120,000.00 15,000.00 100,000.00 2,000.00 1,100.00 10,000.00 10,000.00 Subtotal $1,265,901.45 Tax 9.5% $120,260.64 Total $1,386,162.09 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 17 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item h No. Unit Description Est. Quantity Rodarte Construction, Inc. Unit Price Bid Amount 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan . 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 GravelBorrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 6-lnch Diam. PVC Storm Sewer Pipe. 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 OilAA/ater Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe 24 Televison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum LumpSum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 75,000.00 500.00 • 5,000.00 5,000.00 50.00 18.00 65.00 2,500.00 30.00 30.00 120.00 10,000.00 65.00 65.00 115.00 800.00 1,500.00 6,200.00 8,000.00 4,500.00 145.00 145.00 145.00 3.00 90.00 10,000.00 10,000.00 50.00 35.00 80.00 32.00 1,200.00 50.00 42.00 1,500.00 50.00 350.00 5,000.00 36,000.00 44,000.00 105,000.00 78,000.00 145,000.00 38,500.00 38,500.00 17,500.00 32,000.00 6,500.00 9,500.00 150,000.00 130.00P.00 7,600.00 132,000.00 15.00P.00 15.00 18,000.00 20,000.00 75,000.00 500.00 5,000.00 5,000.00 5,000.00 8,100.00 3,250.00 2,500.00 4,500.00 3,900.00 24.00P.P0 10,000.00 3,575.00 9,750.00 2,875.00 1,600.00 1,500.00 6,200.00 8,000.00 4,500.00 7,250.00 12,325.00 5,800.00 1,065.00 9,900.00 10,000.00 10,000.00 1,250.00 3,150.00 1,600.00 8,160.00 1,200.00 2,500.00 2,310.00 1,500.00 4,500.00 1,400.00 5,000.00 36,000.00 44,000.00 105,000.00 78,000.00 145,000.00 38,500.00 38,500.00 17,500.00 32,000.00 6,500.00 9,500.00 150,000.00 130,000.00 7,600.00 132,000.00 15,000.00 16,500.00 18,000.00 20,000.00 Subtotal $1,313,260.00 Tax 9.5% $124,759.70 Total $1,438,019.70 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 18 of 146 0Q .*-. CD c .-_ ^Q_ LU a c 3 E • E E E E E 3 r3 n 3 3 COCOCOCOCCCCOG a. o. a. o. P P P o. p ."-> ," EEEEhhhEhhh 3333 _- o o o ooo o o o o o .-o o o o oo CO o o o LO CO o o o o in CM •<-o o o o o o o o o o CM •* o o o CO CO CO o o o o o •* o o o o o o o o m r-m CO o o o o CD CD o o in r-CD •*-o o o o o T-o o o LO CM o o o o o tf o o o o m CD o o o o o CD o o o o o LO o o o o o _-o o o o o o o o LO r~ T-o o o LO N. CO o o o o o LO o o o o o •* o o in CM CD t-o o o o CM o o o o CM o o o CD CO o o o o CM T" o o o LO CO o o o CO 1-o o o o o CM o o o LO CD o o o o CM •^ o o o o o CO o o o o o LO ooooo ooooo d d d d d ooooo ooooo ooooo ooooo oooo ooooo CM O O LO LO LO CD CD OOOOOO OOOOOO o o o o o o O CO CD O O CM CM CM O LO CD O <D t O h- O LO O CM" M-" CD~ CD" O O LO 3 O 3 O •> LO CM O O O O O O O O O O O O LO CD O O O CO O O LO CO o o CM CO o o o o CM o o LO r- o o CD' CM o o o o o o o LO r- oooooo oooooo oooo CO LO o o o o" d o o o o LO~ LO" o o o o o CD O O O o o CD O O O O O O CO o o o o o CD O o o o o CM o O O O O LO CD O O O O O CO o o CM CM o o o o o o CM •«- T- T- T- O lO LO T- r-LO CM O O CD CM O LO LO LO E o o 3 o o C C LY) U- LL ° ° Q-ra 15 u_ .c x: x: x: x: _ o o o o o — i_ w ro ro ro ro ro ro F000l__LUL_JLUL_J -5 .£ .E .__ oo'o'o'oE E12 O O O O O 3 3 CO Ll-li_U.U-Ll.CO CO >- a. a. o E E 5 __3 3 — _____ o m CI) c ra (I) C m II) c ra ID c m m __ o o 1 "m m _j >- __ CO u CO o o II m A) _i r o ra HI >- CO B. u- EEEEEEEEE E E E E E E CO a. cococococococococococococococo Cd D. Q. E 2» LU E E __.__.CL__. E E E E Q. Q. E E a. o. o. a. a. o. CO CO o. a. E E E E E E E 3 3 CO CO a. a. E E a. o o a. . CO o O •o 0 XI '» ~ i= 3 3 cn ^_5 in -1 < ~o "a --• O ffi 0 a. Q. f-ro _2 ra o)- __ *= cn E o O <D - __ - 3 CO UJ • £ 4 ' _?__! Q_ |S§I ID O a. __ CO H •^ ra o 0 O 0_ I ° o Q_ CQ -o — a> g> _= > in c_ in ra ra a. g _i O § H O O _M O 0) > ™CL CO ^ x: <L> o x_ f- -? 33 3 y. ra CO in o -o <S O 0 O -= ~. in < X 0 a> a. _- 0) 5 ID a) co E o S« i> El 5° __: o o c c- — T CM co T- 5 co P O ral | 3 8 i co o £•" ra <D ID CO E a) co __: > > ro ID > Q Q_ I i E ° CO >, (J 0 ID O LU T- - __••*_;.__« Hh a ra ra _. !s CO <" i? w CO ID _ CO CO O o CD CD O O O > > 0- a. EE E co ro ra m ca ra ra '^r F; Q c ro __ b o __: x: o o ~ x: ro XI 3 O ID O £ a) o o. c: ,>, o H O ID tt) P J2 ^ = co __ ID in ID 5, a) o c o O 0 u. O o o ro ro O O -=-=-) O ^ 0 ro I- -J co 0 o E o 0 h- O 0 E 0 OOO ro O "__ 0 E 0 in ra _^. - =f 8 o c ro ro o CD LU D) E CO o t 0 > O £ co O 0- . JS -K m i1 ~e _0 0- 0 0 in • m "ffi w I y __ f? b o in cn in Q. 0- E 3 D. O) c X) __: o 0 5 0 co 0 i- E M ro o < CO o "ro t— 0 CZ CO 3 t_ ro to ro XI < CO J-; ^ -a ra —I c 2 0 'a = a 0 -2. <u E o S S " o o _ . . ° ° § .2 o GOnOmwjj o -9- > xi 5» CO CO _____>*-*- D. Q. O J J _S jS o ro 0 CD 0 E 3 CJ co co ••___>•_.•« in ™ 0 CO H __ J2 X X LU LU CMM^_UDCD_^ODCDC:'T_C,,,COT,'LncD,v-oocno,_CNl<^":fLncO l"~ °° CD CO cn CO CO O T- CM CO Tf IO <D S CO O. O T- -. v m in CM CO •* LO CD r~ LO LO LO LO LO LO o o o CM CD O CD CO CO «• CO oo M" O CM CO T-__- <«- o CO to r- 7 c .   ‐   C i t y   C l e r k   r e p o r t s   b i d   o p e n i n g   o n   8 / 2 4 / 2 0 1 0   f o r   C A G ‐ 1 0 ‐ 0 8 7 ,   S t o n e g a t e   L i f t   S t a t i o n   R e p l a c e m e n t ;   1 4   b i d s ;   e n g i n e e r ’ s   e s t i m a t e   P a g e 1 9 o f 1 4 6 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item r- No. Unit Description Est. Quantity 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 6-Inch Diam. PVC Storm Sewer Pipe 14 8-lnch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 Oil/Water Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-lnch Diam. PVC C900 Gravity Sewer Pipe 24 Televison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 . 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 Oceanside Construction, Inc. Unit Price Bid Amount 60,000.00 1,000.00 4,000.00 6,700.00 52.00 28.00 27.00 555.00 28.00 28.00 107.00 55,000.00 80.00 23.00 45.00 1,0O0.P0 1,200.00 4,000.00 6,000.00 3,200.00 40.00 121.00 166.00 1.00 200.00 15,000.00 15,000.00 28.00 32.00 159.00 24.00 1,000.00 104.00 30.00 1,389.00 44.00 250.00 15,000.00 30,000.00 161,000.00 44,000.00 56,000.00 89,000.00 51,000.00 107,000.00 14.0PP.O0 1.60P.00 500.00 2,000.00 130,000.00 131,000.00 16,000.00 138,000.00 5,000.00 20.00 8,200.00 8,000.00 60,000.00 1,000.00 4,000.00 6,700.00 5,200.00 12,600.00 1,350.00 555.00 4,200.00 3,640.00 21,400.00 55,000.00 4,400.00 3,450.00 1,125.00 2,000.00 1,200.00 4,000.00 6,000.00 3,200.00 2,000.00 10,285.00 6,640.00 355.00 22,000.00 15,000.00 15,000.00 700.00 2,880.00 3,180.00 6,120.00 1,000.00 5,200.00 1,650.00 1,389.00 3,960.00 1,000.00 15,000.00 30,000.00 161,000.00 44,000.00 56.00P.00 89,000.00 51,000.00 107,000.00 14,000.OP 1,600.00 500.00 2,000.00 1.30,000.00 131,000.00 16,000.00 138,000.00 5,000.00 22,000.00 8.200.0P 8.PPP.P0 Subtotal $1,328,679.00 Tax 9.5% $126,224.51 Total $1,454,903.51 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 20 of 146 Project Title:Stonegate Lift Station Replacement BID DATE E Item r- No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 August 24, 2010 Description Mobilization (Not to Exceed 8% of Contract Total) Spill Prevention, Control and Countemneasures (SPCC) Plan Traffic Control Construction Surveying and As-Builts . Removal and Replacement of Unsuitable Foundation Material Gravel Borrow (as required) Washed Rock for Infiltration Trench Trench Shoring or Extra Excavation Class A and B Crushed Surfacing Top Course (as required) Crushed Surfacing Base Course HMA Class 1/2" PG 64-22 Facility Coatings 6-Inch Diam. PVC Storm Sewer Pipe 8-Inch Diam. PVC Storm Sewer Pipe 12-inch Diam. PVC Storm Sewer Pipe Catch Basin Type 1 and 1P Catch Basin Type 1 with Birdcage Oil/Water Separator 48-Inch Diam. Sanitary Sewer Manhole Type I 1-Inch Water Service Connection 8-Inch Piam. PVC Gravity Sewer Pipe 12-lnch Diam. PVC Gravity Sewer Pipe 12-Inch Diam. PVC C900 Gravity Sewer Pipe Televison Inspection 8-Inch Diam. PVC C900 Sewer Force Main Temporary Erosion/Sedimentation Controls Landscaping Top Soil Type C Cement Concrete Curb and Gutter Cement Concrete Driveway Entrance Chain Link Fence Chain Link Gate Cement Concrete Sidewalk Quarry Spalls (as required) Pavement Marking Gravity Block Wall Bollard Site Clearing and Grading Lift Station Excavation and Backfill Lift Station Shoring and Trench Safety Systems Dewatering System 144-Inch Diam. Precast Concrete Wet Well Precast Concrete Overflow Storage Vault Precast Concrete Flow Meter and Valve Vault CMU Control Building with Screening Wall Lift Station Piping Lift Station Accessories Control Building Plumbing, Including Roof Drains Mechanical Work Submersible Sewage Pumps and Motors Electrical Work Instrument,, Alarm, Telemetry and Control Work Standby Generator Set Testing and Startup Services Imported Backfill Material Existing Stonegate Lift Station Abandonment Existing Summerwind Lift Station Abandonment Unit Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum Est. Quantity 1 1 1 1 100 450 50 1 150 130. 200 1 55 150 25 2 1 , 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 '1,100 1 1 Boss Construction, Inc. Unit Price 104,000.00 5,000.00 20,000.00 5,000.00 50.00 19.00 22.00 4,000.00 18.00 18.00 93.00 45,000.00 45.00 36.00 83.00 600.00 700.00 3,500.00 3,000.00 1,500.00 100.00 70.00 200.00 5.00 60.00 15,000.00 13,000.00 40.00 20.00 80.00 25.00 500.00 40.00 20.00 1,300.00 24.00 500.00 30,000.00 83,000.00 84,800.00 75,000.00 46,000.00 95,000.00 19,000.00 60,000.00 56,000.00 38,000.00 2,400.00 9,000.00 115,000.00 117,000.00 17.00P.O0 116,000.00 3,000.00 19.00 20,000.00 22,000.00 Bid Amount 104,000.00 5,000.00 20,000.00 5,000.00 5,000.00 8,550.00 1,100.00 4,000.00 2,700.00 2,340.00 18,600.00 45,000.00 2,475.00 5,400.00 2,075.00 1,200.00 700,00 3,500.00 3,000.00 1,500.00 5,000.00 5,950.00 8,000.00 1,775.00 6,600.00 15,000.00 13,000.00 1,000.00 1,800.00 1,600.00 6,375.00 500.00 2,000.00 1,100.00 1,300.00 2,160.00 2,000.00 30,000.00 83,000.00 84,800.00 75,000.00 46,000.00 95,000.00 19,000.00 60,000.00 56,000.00 38,000.00 2,400.00 9,000.00 115,0PP.PO 117.PPP.00 17,000.00 116.0PP.PP 3,000.00 20,900.PP 2P.POO.00 22,000.00 Subtotal $1,345,400.00 Tax 9.5% $127,813.00 Total $1,473,213.00 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 21 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item b No. Unit Description Est. Quantity 1 Mobilization (Not to Exceed 8% of Contract Total) Lump Sum 1 2 Spill Prevention, Control and Countermeasures (SPCC) Plan Lump Sum 1 3 Traffic Control Lump Sum 1 4 Construction Surveying and As-Builts Lump Sum 1 5 Removal and Replacement of Unsuitable Foundation Material Ton 100 6 Gravel Borrow (as required) Ton 450 7 Washed Rock for Infiltration Trench Ton 50 8 Trench Shoring or Extra Excavation Class A and B Lump Sum 1 9 Crushed Surfacing Top Course (as required) Ton 150 10 Crushed Surfacing Base Course Ton 130 11 HMA Class 1/2" PG 64-22 Ton 200 12 Facility Coatings Lump Sum 1 13 6-Inch Diam. PVC Storm Sewer Pipe Lineal Foot 55 14 8-Inch Diam. PVC Storm Sewer Pipe Lineal Foot .150 15 12-Inch Diam. PVC Storm Sewer Pipe Lineal Foot. 25 16 Catch Basin Type 1 and 1P Each 2 17 Catch Basin Type 1 with Birdcage Each 1 18 Oil/Water Separator Each 1 19 48-Inch Diam. Sanitary Sewer Manhole Type I Each 1 20 1-Inch Water Service Connection Each 1 21 8-Inch Diam. PVC Gravity Sewer Pipe Lineal Foot 50 22 12-Inch Diam. PVC Gravity Sewer Pipe Lineal Foot 85 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe Lineal Foot 40 24 Televison Inspection Lineal Foot 355 25 8-Inch Diam. PVC C900 Sewer Force Main Lineal Foot 110 26 Temporary Erosion/Sedimentation Controls Lump Sum 1 27 Landscaping Lump Sum 1 28 Top Soil Type C Cubic Yard 25 29 Cement Concrete Curb and Gutter Lineal Foot 90 30 Cement Concrete Driveway Entrance Square-Yard 20 31 Chain Link Fence Lineal Foot 255 32 Chain Link Gate. Each 1 33 Cement Concrete Sidewalk Square-Yard 50 34 Quarry Spalls (as required) Ton 55 35 Pavement Marking LumpSum 1 36 Gravity Block Wall Square-Foot 90 37 Bollard Each 4 38 Site Clearing and Grading Lump Sum 1 39 Lift Station Excavation and Backfill Lump Sum 1 40 Lift Station Shoring and Trench Safety Systems LumpSum 1 41 Dewatering System Lump Sum 1 42 144-Inch Diam. Precast Concrete Wet Well LumpSum 1 43 Precast Concrete Overflow Storage Vault Lump Sum 1 44 Precast Concrete Flow Meter and Valve Vault Lump Sum 1 45 CMU Control Building with Screening Wall Lump Sum 1 46 Lift Station Piping Lump Sum 1 47 Lift Station Accessories Lump Sum 1 48 Control Building Plumbing, Including Roof Drains LumpSum 1 49 Mechanical Work Lump Sum 1 50 Submersible Sewage Pumps and Motors Lump Sum 1 51 Electrical Work Lump Sum 1 52 Instrument, Alarm, Telemetry and Control Work Lump Sum 1 53 Standby Generator Set Lump Sum 1 54 Testing and Startup Services Lump Sum 1 55 Imported Backfill Material Ton 1,100 56 Existing Stonegate Lift Station Abandonment LumpSum 1 57 Existing Summerwind Lift Station Abandonment Lump Sum 1 Mid Mountain Contractors Inc. Unit Price 100,000.00 1,000.00 4,000.00 6,000.00 45.00 20.00 22.00 45,000.00 32.00 35.00 110.00 72,000.00 30.00 35.00 40.00 1,600.00 4,300.00 8,000.00 4,500.00 1,250.00 50.00 100.00 90.00 4.00 60.00 5,500.00 13,000.00 35.00 58.00 150.0P 28.00 350.00 90.00 26.00 1,500.00 40.00 600.00 7,000.00 32,000.00 118,000.00 55,000.00 65,000.00 110,000.00 35,000.00 82,000.00 32,000.00 27,000.00 4,000.00 20,000.00 126,000.00 117,0PP.00 7,000.00 120,000.00 3,700.00 22.00' 14,000.00 15,000.00 Bid Amount 100,000.00 1,000.00 4,000.00 6,000.00 4,500.00 9,000.00 1,100.00 45,000.00 4,800.00 4,550.00 22,000.00 72,000.00 1,650.00 5,250.00 1,000.00 3,200:00 4,300.00 8,000.00 4,500.00 1,250.00 2,500.00 8,500.00 3,600.00 1,420.00 6,600.00 5,500.00 13,000.00 875.00 5,220.00 3,000.00 7,140.00 350.00 4,500.00 1,430.00 1,500.00 3,600.00 2,400.00 7,000.00 32,000.00 118,000.00 55,000.00 65,000.00 110,000.00 35,000.00 82,000.00 32,000.00 27,000.00 4,000.00 20,000.00 126,000.00 117,000.00 7,000.00 120,000.00 3,700.00 24,200.00 14,000.00 15,000.PP Subtotal $1,388,135.00 Tax 9.5% $131,872.83 Total $1,520,007.83 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 22 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item b No. Unit Description Est. Quantity Omega Contractors Inc. Unit Price Bid Amount 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countenneasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 6-Inch Diam. PVC Storm Sewer Pipe 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-lnch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 Oil/Water Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-lnch Diam. PVC Gravity Sewer Pipe 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe 24 Televison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 20,000.00 1,600.00 1,700.00 7,400.00 36.00 18.00 24.00 10,000.00 22.00 22.00 125.00 76,000.00 150.00 150.00 200.00 1,850.00 2,000.00 7,000.00 4,000.00 3,300.00 176.00 130.00 140.00 5.00 125.00 6,000.00 14,800.00 40.00 40.00 140.00 30.00 1,000.00 85.00 36.00 1,425.00 30.00 500. OP 1,400.00 20,000.00 20,000.00 41,200.00 110,000.00 153,000.00 60.000.PO 93,571.00 31,192.00 45,450.00 8,600.00 10,500.00 132,000.00 154,000.00 ' 8,000.00 132.000.0P 8,000.00 20.00 13,500.00 16,500.00 2O.00P.0O 1,600.00 1,700.00 7,400.00 3,600.00 8,100.00 1,200,00 10,000.00 3,300.00 2,860.00 25,000.00 76,000.00 8,250.00 22,500.00 5,000.00 3,700.00 2,000.00 7,000.00 4,000.00 3,300.00 8,800.00 11,050.00 5,600.00 1,775.00 13,750.00 6,000.00 14,800.00 1,000.00 3,600.00 2,800.00 7,650.00 1,000.00 4,250.00 1,980.00 1,425.00 2,700.00 2,000.00 1,400.00 20,000.00 20,000.00 41,200.00 110,000.00 153,000.00 60,000.00 93,571.00 , 31,192.00 45,450.00 8,600.00 10,500.00 132,000.00 154,000.00 8,000.00 132,000.00 8,000.00 22,000.00 13,500.00 16,500.00 Subtotal $1,387,603.00 Tax 9.5% $131,822.29 Total $1,519,425.29 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 23 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item r- No. Unit Description Est. Quantity McClure and Sons Inc. Unit Price Bid Amount 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 6-Inch Diam. PVC Storm Sewer Pipe 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 Oil/Water Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-lnch Diam. PVC C900 Gravity Sewer Pipe 24 Televison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 Landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 75,000.00 1.00P.PO 1,000.00 5,000.00 40.00 20.00 30.00 9,000.00 20.00 25.00 100.00 60,000.00 186.00 86.00 130.0P 1,600.00 1,700.00 5,500.00 7,000.00 3,000.00 75.00 225.00 250.00 2.00 95.00 20,000.00 15,000.00 55.00 25.00 75.00 30.00 2,000.00 40.00 30.00 1,500.00 20.00 320.00 4,000.00 32,000.00 112,000.00 33,000.00 65,000.00 80,000.00 50,000.00 130,000.00 25,000.00 1,000.00 3,000.00 28,000.00 133,000.00 113,000.00 15,000.00 125,000.00 10.000.0P 22.P0 50,000.00 50,000.00 75,000.00 1,000.00 1,000.00 5,000.00 4,000.00 9,000.00 1,500.00 9,000.00 3,000.00 3,250.00 20,000.00 : 60,000.00 10,230.00 12,900.00 3,250.00 3,200.00 1,700.00 5,500.00 7,000.00 3,000.00 3,750.00 19,125.00 10,000.00 710.00 10,450.00 20,000.00 15,000.00 1,375.00 2,250.00 1,500.00 7,650.00 2,000.00 2,000.00 1,650.00 1,500.00 1,800.00 1,280.00 4,000.00 32,000.00 112,000.00 33,000.00 65,000.00 80,000.00 50,000.00 130,000.00 25,000.00 1,000.00 3,000.00 28,000.00 133.0PP.0O 113,000.00 15,000.00 125.0PO.OO 10,000.00 24,200.00 50,000.00 50,000.00 Subtotal - $1,423,770.00 Tax 9.5% $135,258.15 Total $1,559,028.15 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 24 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item b No. Description Unit Est. Quantity 1 Mobilization (Not to Exceed 8% of Contract Total) Lump Sum 1 2 Spill Prevention, Control and Countermeasures (SPCC) Plan Lump Sum 1 3 Traffic Control LumpSum 1 4 Construction Surveying and As-Builts Lump Sum 1 5 Removal and Replacement of Unsuitable Foundation Material Ton 100 6 Gravel Borrow (as required) Ton 450 7 Washed Rock for Infiltration Trench Ton 50 8 Trench Shoring or Extra Excavation Class A and B Lump Sum 1 9 Crushed Surfacing Top Course (as required) Ton 150 10 Crushed Surfacing Base Course Ton 130 11 HMA Class 1/2" PG 64-22 Ton 200 12 Facility Coatings LumpSum 1 13 6-Inch Diam. PVC Storm Sewer Pipe Lineal Foot 55 14 8-Inch Diam. PVC Storm Sewer Pipe Lineal Foot 150 15 12-Inch Diam. PVC Storm Sewer Pipe Lineal Foot 25 16 Catch Basin Type 1 and 1P Each 2 17 Catch Basin Type 1 with Birdcage Each 1 18 Oil/Water Separator Each 1 19 48-Inch Diam. Sanitary Sewer Manhole Type I Each 1 20 1-Inch Water Service Connection Each 1 21 8-Inch Diam. PVC Gravity Sewer Pipe Lineal Foot 50 22 12-Inch Diam. PVC Gravity Sewer Pipe Lineal Foot 85 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe Lineal Foot 40 24 Televison Inspection Lineal Foot 355 25 8-Inch Diam. PVC C900 Sewer Force Main Lineal Foot 110 26 Temporary Erosion/Sedimentation Controls Lump Sum 1 27 Landscaping LumpSum 1 28 Top Soil Type C Cubic Yard 25 29 Cement Concrete Curb and Gutter Lineal Foot 90 30 Cement Concrete Driveway Entrance Square-Yard 20 31 Chain Link Fence Lineal Foot 255 32 Chain Link Gate Each 1 33 Cement Concrete Sidewalk Square-Yard 50 34 Quarry Spalls (as required) Ton 55 35 Pavement Marking Lump Sum 1 36 Gravity Block Wall Square-Foot 90 37 Bollard Each 4 38 Site Clearing and Grading Lump Sum 1 39 Lift Station Excavation and Backfill Lump Sum 1 40 Lift Station Shoring and Trench Safety Systems Lump Sum 1 41 Dewatering System Lump Sum 1 42 144-Inch Diam. Precast Concrete Wet Well LumpSum 1 43 Precast Concrete Overflow Storage Vault Lump Sum 1 44 Precast Concrete Flow Meter and Valve Vault Lump Sum 1 45 CMU Control Building with Screening Wall Lump Sum ' 1 46 Lift Station Piping Lump Sum 1 47 Lift Station Accessories Lump Sum 1 48 Control Building Plumbing, Including Roof Drains Lump Sum 1 49 Mechanical Work LumpSum 1 50 Submersible Sewage Pumps and Motors Lump Sum 1 51 Electrical Work LumpSum 1 52 Instrument, Alarm, Telemetry and Control Work Lump Sum 1 53 Standby Generator Set LumpSum 1 54 Testing and Startup Services Lump Sum 1 55 Imported Backfill Material Ton 1,100 56 Existing Stonegate Lift Station Abandonment LumpSum 1 57 Existing Summerwind Lift Station Abandonment Lump Sum 1 'ivetta Brothers Construction, Inc. Unit Price 129,076.00 450.00 16,517.00 4,752.00 30.00 15.25 25.00 3,000.00 30.00 30.00 123.00 72,580.00 36.00 15.00 40.00 915.00 950.00 5,750.00 7,201.00 1,058.00 33.00 98.00 143.00 3.50 56.25 5,500.00 14,559.00 45.00 36.00 86.00 34.00 1,271.00 58.00 23.50 1,471.00 20.50 710.00 18,895.00 67,867.00 71,714.00 82,627.00 82,598.00 190,984.00 64,085.00 75,946.00 72,155.00 21,336.00 5,795.00 13,302.00 118,056.00 104,350.00 13,400.00 120,317.00 60,000.00 15.25 21,007.00 22,459.00 Bid Amount 129,076.00 450.00 16,517.00 4,752.00 3,000.00 6,862.50 1,250.00 3,000.00 4,500.00 3,900.00 24,600.00 72,580.00 1,980.00 2,250.00 1,000.00 1,830.00 950.00 5,750.00 7,201.00 1,058.00 1,650.00 8,330.00 5,720.00 1,242.50 6,187.50 5,500.00 14,559.00 1,125.00 3,240.00 1,720.00 8,670.00 1,271.00 2,900.00 1,292.50 1,471.00 1,845.00 2,840.00 18,895.00 67,867.00 71,714.00 82,627.00 82,598.00 190,984.00 64,085.00 75,946.00 72,155.00 21,336.00 5,795.00 13,302.00 118,056.00 104,350.00 13,400.00 120,317.00 60,000.00 16,775.00 21,007.00 22,459.00 Subtotal $1,605,738.00 Tax 9.5% $152,545.11 Total $1,758,283.11 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 25 of 146 Project Title:Stonegate Lift Station Replacement BID DATE: August 24, 2010 E Item h No. Unit Description Est. Quantity Harbor Pacific Contractors, Inc. Unit Price Bid Amount 1 Mobilization (Not to Exceed 8% of Contract Total) 2 Spill Prevention, Control and Countermeasures (SPCC) Plan 3 Traffic Control 4 Construction Surveying and As-Builts 5 Removal and Replacement of Unsuitable Foundation Material 6 Gravel Borrow (as required) 7 Washed Rock for Infiltration Trench 8 Trench Shoring or Extra Excavation Class A and B 9 Crushed Surfacing Top Course (as required) 10 Crushed Surfacing Base Course 11 HMA Class 1/2" PG 64-22 12 Facility Coatings 13 . 6-Inch Diam. PVC Storm Sewer Pipe 14 8-Inch Diam. PVC Storm Sewer Pipe 15 12-Inch Diam. PVC Storm Sewer Pipe 16 Catch Basin Type 1 and 1P 17 Catch Basin Type 1 with Birdcage 18 Oil/Water Separator 19 48-Inch Diam. Sanitary Sewer Manhole Type I 20 1-Inch Water Service Connection 21 8-Inch Diam. PVC Gravity Sewer Pipe 22 12-Inch Diam. PVC Gravity Sewer Pipe 23 12-Inch Diam. PVC C900 Gravity Sewer Pipe 24 Teievison Inspection 25 8-Inch Diam. PVC C900 Sewer Force Main 26 Temporary Erosion/Sedimentation Controls 27 landscaping 28 Top Soil Type C 29 Cement Concrete Curb and Gutter 30 Cement Concrete Driveway Entrance 31 Chain Link Fence 32 Chain Link Gate 33 Cement Concrete Sidewalk 34 Quarry Spalls (as required) 35 Pavement Marking 36 Gravity Block Wall 37 Bollard 38 Site Clearing and Grading 39 Lift Station Excavation and Backfill 40 Lift Station Shoring and Trench Safety Systems 41 Dewatering System 42 144-Inch Diam. Precast Concrete Wet Well 43 Precast Concrete Overflow Storage Vault 44 Precast Concrete Flow Meter and Valve Vault 45 CMU Control Building with Screening Wall 46 Lift Station Piping 47 Lift Station Accessories 48 Control Building Plumbing, Including Roof Drains 49 Mechanical Work 50 Submersible Sewage Pumps and Motors 51 Electrical Work 52 Instrument, Alarm, Telemetry and Control Work 53 Standby Generator Set 54 Testing and Startup Services 55 Imported Backfill Material 56 Existing Stonegate Lift Station Abandonment 57 Existing Summerwind Lift Station Abandonment Lump Sum Lump Sum Lump Sum Lump Sum Ton Ton Ton Lump Sum Ton Ton Ton Lump Sum Lineal Foot Lineal Foot Lineal Foot Each Each Each Each Each Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lineal Foot Lump Sum Lump Sum Cubic Yard Lineal Foot Square-Yard Lineal Foot Each Square-Yard Ton Lump Sum Square-Foot Each Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Lump Sum Ton Lump Sum Lump Sum 1 1 1 1 100 450 50 1 150 130 200 1 55 150 25 2 1 1 1 1 50 85 40 355 110 1 1 25 90 20 255 1 50 55 1 90 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1,100 1 1 102,000.00 1,500.00 18,000.00 9,000.00 33.10 31.80 29.70 20,500.00 34.50 34.00 120.00 58,000.00 56.20 59.50 105.00 1,600.00 2,400.00 7,200.00 24,000.00 3,000.00 115.00 315.00 148.00 2.00 130.00 52,000.00 12,000.00 32.00 34.00 90,00 23.00 1,150.00 80.00 48.00 2,000.00 20.00 400.00 47,320.00 61,240.00 64,365.00 98,150.00 82,000.00 128,000.00 31,500.00 80,000.00 65,000.00 42,000.00 5,000.00 21,000.00 132,000.00 98,600.00 12,500.00 105,000.00 6,479.00 20.15 30,600.00 28,770.00 102,000.00 1,500.00 18,000.00 9,000.00 3,310.00 14,310.00 1,485.00 20,500.00 5,175.00 4,420.00 24,000.00 58,000.00 3,091.00 8,925.00 2,625.00 3,200.00 2,400.00 7,200.00 24,000.00 3,000.00 5,750.00 26,775.00 5,920.00 710.00 14,300.00 52,000.00 12,000.00 800.00 3,060.00 1,800.00 5,865.00 1,150.00 4,000.00 2,640.00 2,000.00 1,800.00 1,600.00 47,320.00 61,240.00 64,365.00 98,150.00 82,000.00 128,000.00 31,500.00 80,000.00 65,000.00 42,OOP.00 v 5,000.00 21,000.00 132,000.00 98,600.00 12,500.00 105,000.00 6,479.00 22,165.00 30,600.00 28,770.00 Subtotal $1,620,000.00 Tax 9.5% $153,900.00 Total $1,773,900.00 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 26 of 146 CITY OF RENTON BID TABULATION SHEET PROJECT: Stonegate Lift Station Replacement CAG-10-087 DATE: August 24, 2010 Page 1 of 2 BIDDER Boss Construction, Inc. 4945 Guide Meridian Bellingham, WA 98226 Tim Hart Ceccanti 4118 Brookdale Rd. E. Tacoma, WA 98446 Donna Motland Harbor Pacific Contractors, Inc. 19628 144th Ave. NE, Ste. A Woodinville, WA 98072 Nick DeVitis Massana Construction, Inc. 2Tanglewood Island Fox Island, WA 98333 Mark Massmann McClure and Sons, Inc. 15714 Country Club Dr. Mill Creek, WA 98012 Les McClure MidMountain Contractors P.O. Box 2909 Kirkland, WA 98083 Greg Steels Oceanside Construction, Inc. 1225 E. Sunset Dr., Ste. 145 Bellingham, WA 98226 Joseph Baldwin Omega Constractors, Inc. P.O. Box 430 Duvall, WA 98019 Gordon Wagster Pivetta Brothers Construction, Inc. P.O. Box 370 Sumner, WA 98390 Mark Pivetta Plats Plus, Inc. 720 Cedar Ave, Ste. C Marysville, WA 98270 FORMS Proposal & Triple Form X X X X X X X X X X L&l Cert X X X X X X X X X X Bid Bond X X X X X X X X X X Sched. of Prices X X X X X X X X X X Subs List X X X X X X X X X Addenda 1-5 X X X X X X X X X X BID **lncludes Sales Tax $1,473,213.00 $1,520,007.83 $1,386,162.09 $1,773,900.00 $1,313,184.00 $1,582,023.00 $1,559,028.15 $1,517,149.87 $1,454,903.51 $1,519,425.29 $1,758,283.11 $1,281,555.15 Brendan Reeves 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 27 of 146 CITY OF RENTON BID TABULATION SHEET PROJECT: Stonegate Lift Station Replacement CAG-10-087 DATE: August 24, 2010 Page 2 of 2 BIDDER FORMS Proposal & Triple Form L&l Cert. Bid Bond Sched. of Prices Subs List Addenda 1-5 BID **lncludes Sales Tax R.L. Alia Company 107 Williams Ave. S. Renton, WA 98057 Richard L. Alia Rodarte Construction, Inc. P.O. Box 1875 Auburn, WA 98071 J.R. Rodarte Shoreline Construction, Co. P.O. Box 358 Woodinville, WA 98072 Douglas J. Suzuki Western Engineering Contractors 500 Locust St. Ellensburg, WA 98926 Michael J. Wieck ENGINEER'S ESTIMATE LEGEND: Forms: Triple Form: Non-Collusion Affidavit, Anti-Trust Claims, Minimum Wage $1,281,555.15 $1,438,019.70 $1,213,270.95 $1,150,458.90 $1,432,938.90 $1,404,019.95 7c. ‐ City Clerk reports bid opening on 8/24/2010 for CAG‐10‐087,  Stonegate Lift Station Replacement; 14 bids; engineer’s estimate Page 28 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: Application by Barghausen Engineers for Partial Release of Easement for Slopes; an area of approximately 3,729 sq. ft. located at 10436 SE Carr Rd. (File RE-10-002) Meeting: Regular Council - 20 Sep 2010 Exhibits: - Application, including legal description & map - Easement For Slopes #5840168 Submitting Data: Dept/Div/Board: Executive Staff Contact: Bonnie I. Walton, City Clerk, x6502 Recommended Action: Refer to Transportation Committee Fiscal Impact: Expenditure Required: $ Transfer Amendment: $ Amount Budgeted: $ Revenue Generated: $ Total Project Budget: $ City Share Total Project: $ SUMMARY OF ACTION: On May 19, 2010, Hal Grubb, P.E., 18215 72nd Ave. S., Kent, WA 98032, (Barghausen Engineers), filed an application for partial release of Easement For Slopes. The area to be released consists of approximately 3,729 sq. ft. located on the north side of Carr Rd, at 10436 SE Carr Rd, in a vicinity west of 108th Ave. SE (SR 515) and east of Talbot Rd. S. The easement, dated 1/14/1965, was recorded under King County Recording No. 5840168 and was obtained by the City from King County as part of annexation in 2008. An application filing fee of $250 has been paid. The Development Services Division has reviewed the Application for Partial Release of Easement, and determined that the release of easement petition is valid and the legal description is now accurate. Under RMC 9-1, Council should now: 1) Determine whether the release of easement proposal should be granted, the classification of the easement, whether there are conditions of the approval, and whether an appraisal is necessary to determine the amount of compensation to be paid, if any, and 2) If so approved, adopt an ordinance to finalize the release if all determinations have been made and all conditions have been met within 90 days of Council approval. STAFF RECOMMENDATION: Take action as set forth in RMC 9-1 7d. ‐ City Clerk submits request for partial release of Easement for  Slopes by Hal Grubb, Barghausen Engineers, 18215 72nd Ave. S., Kent, Page 29 of 146 7d. ‐ City Clerk submits request for partial release of Easement for  Slopes by Hal Grubb, Barghausen Engineers, 18215 72nd Ave. S., Kent, Page 30 of 146 7d. ‐ City Clerk submits request for partial release of Easement for  Slopes by Hal Grubb, Barghausen Engineers, 18215 72nd Ave. S., Kent, Page 31 of 146 7d. ‐ City Clerk submits request for partial release of Easement for  Slopes by Hal Grubb, Barghausen Engineers, 18215 72nd Ave. S., Kent, Page 32 of 146 7d. ‐ City Clerk submits request for partial release of Easement for  Slopes by Hal Grubb, Barghausen Engineers, 18215 72nd Ave. S., Kent, Page 33 of 146 7d. ‐ City Clerk submits request for partial release of Easement for  Slopes by Hal Grubb, Barghausen Engineers, 18215 72nd Ave. S., Kent, Page 34 of 146 7d. ‐ City Clerk submits request for partial release of Easement for  Slopes by Hal Grubb, Barghausen Engineers, 18215 72nd Ave. S., Kent, Page 35 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: Appeal Code Revisions Meeting: Regular Council - 20 Sep 2010 Exhibits: l Issue Paper l Draft Ordinance Submitting Data: Dept/Div/Board: Community and Economic Development Staff Contact: Rocale Timmons, ext. 7219 Recommended Action: Refer to the Planning and Development Committee Fiscal Impact: Expenditure Required: $ Transfer Amendment: $ Amount Budgeted: $ Revenue Generated: $ Total Project Budget: $ City Share Total Project: $ SUMMARY OF ACTION: The current provisions governing appeals have not been reviewed in some time and certain legislative changes have occurred which necessitate updates to the current code. To that end, staff and the City Attorney Department have reviewed the applicable appeal provisions in its entirety and have concluded that further updates and changes could also be made to refine the current appeal process. Recommended changes include the removal of many sections of the appeal provisions as they are repetitive and/or unnecessary. Additionally, provisions for reconsideration requests and standing for appeals have been included in the recommended amendments. STAFF RECOMMENDATION: Adopt code revisions to reflect recent legislative changes as it pertains to appeals. 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 36 of 146 h:\ced\city council\issue papers\2010\appeal code revision\appeal process issue paper.doc DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE:August 16, 2010 TO:Don Persson, Council President Members of the Renton City Council VIA:Denis Law, Mayor FROM:Alex Pietsch, Administrator (x 6592) STAFF CONTACT:Rocale Timmons, Associate Planner (x7219) SUBJECT:Appeal Code Revisions ISSUE: Should the City of Renton update the procedures for Appeals to the Hearing Examiner of Administrative Decisions and Environmental Determinations as well as Appeals to the Council? RECOMMENDATION: Staff recommends revising Renton Municipal Code Section 4-8-110, Appeals, in order to clarify procedures for appeals to the Hearing Examiner of Administrative Decisions and Environmental Determinations as well as appeals to Council. BACKGROUND SUMMARY: The current provisions governing appeals have not been reviewed in some time and certain legislative changes and judicial decisions have occurred which necessitate updates to the current code. To that end, staff and the City Attorney have reviewed the applicable appeal provisions in its entirety and have concluded that further updates and changes could also be made to refine the current appeal process. Recommended changes include the removal of many sections of the appeal provisions as they are repetitive and/or unnecessary. Provisions for reconsideration requests have been added, which require land use decisions be held in abeyance pending the outcome of the reconsideration. A new 14-day appeal period would commence upon the issuance of the reconsideration decision. Additionally, changes to the current code would prevent parties who fail to participate in the public hearing, to then emerge after the fact when dissatisfied with the result. A party would only have standing to pursue an appeal if the party "participates" in the hearing process. A party can "participate" in the following ways: 1.Testify or give oral comments at the public hearing; or 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 37 of 146 Don Persson, Council President Page 2 of 2 August 16, 2010 h:\ced\city council\issue papers\2010\appeal code revision\appeal process issue paper.doc 2.Submit written comments to City staff or the Hearing Examiner prior to the close of the public hearing. CONCLUSION: Currently, the code provisions are not consistent with recent legislative changes and judicial decisions. The revisions would update the City’s Appeal Code to reflect those recent legislative changes. Additionally, the inclusion of provisions for standing along with the removal of several sections, which are unnecessary, would simplify and refine the appeal process. cc: Jay Covington, Chief Administrative Officer Larry Warren, City Attorney C. E. “Chip” Vincent, Planning Director Neil Watts, Development Services Director Suzanne Dale Estey, Economic Development Director Jennifer Henning, Current Planning Manager 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 38 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 39 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 40 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 41 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 42 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 43 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 44 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 45 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 46 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 47 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 48 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 49 of 146 7e. ‐ Community and Economic Development Department recommends  amending City Code to adopt legislative changes regarding appeal Page 50 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: Community Development Block Grant (CDBG) changes and 2011 CDBG funding recommendations Meeting: Regular Council - 20 Sep 2010 Exhibits: 1. Revised 2010 CDBG allocations 2. Issue Paper 3. Funding Recommendations 4. Contingency Funding Plan Submitting Data: Dept/Div/Board: Community Services Staff Contact: Karen Bergsvik Recommended Action: Refer to Finance Committee Fiscal Impact: Expenditure Required: $ $667,714 Transfer Amendment: $ Amount Budgeted: $ Revenue Generated: $$667,714 Total Project Budget: $ $667,714 City Share Total Project: $ SUMMARY OF ACTION: There are changes to the 2010 Community Development Block Grant Funds (CDBG). The total allocation is $432,491, which is an increase of $138,193 from prior estimates of the allocation. The majority of the funds are being redirected to the Housing Repair Assistance Program. Applications for the 2011/2012 were read and scored by the Human Services Advisory Committee. They recommended that 35 programs be funded, at the current general fund level of $437,000. The General Fund recommendations will be adopted as part of the City's budget process. It is estimated that Renton will receive $529,521 in Community Development Block Grants (CDBG) for 2011. The CDBG funding recommendations must be adopted after a public hearing, separate from the budget process. As a member of the KIng County Consortium, Renton must adopt the CDBG recommendations to meet the deadlines set by King County. We are also required to adopt a Contingency Plan to cover any changes in funding. STAFF RECOMMENDATION: Approve the 2011/2012 CDBG funding as recommended by the Human Services Advisory Committee, and adopt the proposed Contingency Plan. 7f. ‐ Community Services Department recommends approval of the  revised 2010 and the 2011/2012 Community Development Block Grant Page 51 of 146 H:\Human Services\09\Budget\2010CDBG contract.doc COMMUNITY SERVICES DEPARTMENT M E M O R A N D U M DATE:August 13, 2010 TO:Bonnie Walton, City Clerk CC:Terry Higashiyama, Community Services Administrator FROM:Karen Bergsvik, Human Services Manager SUBJECT:2010 CDBG Contract Attached is the 2010 CDBG contract with King County. It is in the amount of $432,491, which is an increase of $138,193 from prior estimates of the allocation. Program Original 2010 Allocation Revised 2010 Allocation Explanation Multi-Service Center/Emergency Assistance $35,000 $38,719 Received more funds than estimated; distributed according to the contingency plan. Institute for Family Development/Parents and Children Together $12,298 $14,233 Received more funds than estimated; distributed according to the contingency plan. Planning and Administration $47,000 $52,592 Received more funds than estimated; distributed according to the contingency plan. Housing Repair Assistance Program (HRAP) $200,000 $202,712 $86,930 $36,945 $326,587 The 2010 allocation to HRAP is $202,712. This is slightly more than estimated. The amount of unallocated CDBG funds that had been reallocated to HRAP in 2009 are equal to $86,930. Funds in the amount of $20, 693 were not spent 7f. ‐ Community Services Department recommends approval of the  revised 2010 and the 2011/2012 Community Development Block Grant Page 52 of 146 Bonnie Walton, City Clerk Page 2 of 2 August 13, 2010 H:\Human Services\09\Budget\2010CDBG contract.doc by HRAP in 2009 and are being carried forward. Unallocated CDBG funds in the amount of $70,427 were designated to go to traffic signals – see attachment. The traffic signals cost less than estimated, and the $70,427 is no longer needed; therefore $36,945 was reallocated to the HRAP program and the remaining balance is being held in reserve, in case the final invoice for the traffic signals is more than anticipated. The plan is to put as much CDBG funds into HRAP as possible, in order to pay the salary and benefit cost of the Facilities Technician in 2011. The public hearing for the 2011 CDBG funding recommendations is to be held August 17, 2010. We plan to present to Council the 2011 funding recommendations and the changes for 2010 (outlined above), at the same time. This is tentatively planned for the September 13, 2010 meeting. The $138,193 are unspent Capital funds from 2007-2009. They are not new funds. I have spending authority for the funds, as they have been in the city budget in prior years. They are funds that are being reallocated to the Housing Repair Assistance Program. If you would like any further information, please contact me at X6650. KB:ca Attachment 7f. ‐ Community Services Department recommends approval of the  revised 2010 and the 2011/2012 Community Development Block Grant Page 53 of 146 H:\Human Services\09\Legislative\10 Issue Papers\issuepaper1112 CDBG funding NO SPECIFICS(2).doc COMMUNITY SERVICES DEPARTMENT M E M O R A N D U M DATE:August 30, 2010 TO:Don Persson, Council President Renton City Councilmembers VIA:Denis Law, Mayor FROM:Terry Higashiyama, Community Services Administrator STAFF CONTACT:Karen Bergsvik, Human Services Manager, x6652 SUBJECT:Community Development Block Grant (CDBG) Changes and Funding Recommendations for Human Services 2010 CDBG CHANGES: CDBG allocations for 2010 were higher than originally estimated, resulting in a slight increase to the three funded programs, the Housing Repair Assistance Program, the Multi-Service Center, and Institute for Family Development. Unspent funds of $86,930 from the 2009 HRAP contract were included in the 2010 HRAP contract. CDBG funds of $70,427 were originally designated for the Renton Traffic Pedestrian Signal Project. Due to significant savings in materials costs, no CDBG funds were needed for project completion, and the contract was cancelled. $36,945 of the funds were reallocated to HRAP, with the remaining balance being held in reserve until the signal project is complete. Those funds will then be reallocated to HRAP. 2011 CDBG ISSUES 1. Should the highest ranked applications by result for human services funding for 2011/2012 be funded? 2. Approve the 2011/2012 Community Development Block Grant (CDBG) funding recommendations and Contingency Plan. BACKGROUND ·Renton chose to participate with 16 others cities in an electronic application administered by E-Gov Alliance. The process saved agencies time by having to submit only one application to apply to any number of the participating cities, which significantly increased the number of requests submitted. ·Two funding workshops were held for agencies in East and South King County Extensive help was made available to agencies to complete the application-both regionally and locally. ·Facing increased human services needs (requests of $1,177,560) and limited funds 7f. ‐ Community Services Department recommends approval of the  revised 2010 and the 2011/2012 Community Development Block Grant Page 54 of 146 Don Persson, Council President Renton City Councilmembers Page 2 of 3 8/27/10 to allocate ($489,952), the Committee had to make some very difficult decisions in a highly competitive funding cycle. ·Funding is allocated by Renton Result area. The nine areas are: 1)All children and youth are ready for educational success, work and life 2)Individuals have adequate clothing, food, housing and healthcare 3)All individuals become as self-sufficient as possible 4)Residents know about domestic violence and how to keep safe 5)All residents are proactive to issues of sexual assault and sexual violence 6)All residents are healthy and safe 7)All residents identify with and contribute to their community 8)End homelessness in Renton 9)Connect People to Services. ·Each Result has a specific dollar amount to allocate, based on the applications received, historical funding levels, and input from the Human Services Advisory Committee (HSAC). Two result areas received no applications. ·The HSAC used an open and transparent review process that was thorough and equitable. Applications were read and scored by teams of Advisory Committee members, using a rating tool developed by members and staff. Training was provided on how to rate the applications, and each group was supported by a team lead. ·Funding recommendations were based on the points each application received from the scoring process. Applications in a result area were ranked from highest to lowest based on the average score of the HSAC raters. Staff rated the accuracy of the financial tables included in the applications, using criteria established by the Human Services Advisory Committee. Currently funded agencies were eligible for five bonus points for meeting contract goals, and submitting reports on time. ·HSAC members divided into four groups, to review all the applications in their assigned result areas. Each group read, rated and made funding recommendations for their results. Funding recommendations by the four groups were reviewed, discussed, and adopted by entire HSAC. ·HSAC decided that each result would receive funding, and that the top ranked program within each result would be funded, at a minimum, to its 2010 funding level. Programs were funded in the order they were ranked, and programs could not be skipped to fund a lower ranked program. ·The programs recommended for CDBG funding were determined by staff after the HSAC made their funding recommendations. ·It is estimated that Renton will receive $529,521 in Community Development Block Grants for 2011: v $52,952 for Public Services; and $52,952 in Planning and Administration; v $201,218 in Capital funds, of which the Housing Repair Assistance Program will receive $200,000; v The remainder is for the Housing Stability Program, deferred home loan program, and the County administrative costs. This is a requirement of our contract. 7f. ‐ Community Services Department recommends approval of the  revised 2010 and the 2011/2012 Community Development Block Grant Page 55 of 146 Don Persson, Council President Renton City Councilmembers Page 3 of 3 8/27/10 ·A public hearing for CDBG funding recommendations only was held at the Human Services Advisory Committee meeting on August 17, 2010. No comments were received. ·CDBG Public Services funding is recommended for two years, with the second year dependent upon funding and performance. It is recommended that the Institute for Family Development and the Multi-Service Center be funded. ·It is estimated that the City will receive $201,218 in capital funding. Because the city’s Housing Repair Program is recommended for $200,000, it was decided not to seek additional requests for capital funding for 2011. ·King County requires a contingency plan in case CDBG funding differs from the original estimate. The contingency plan is attached. ·General Fund funding recommendations are attached as an informational item only. The recommendations will be adopted through the budget process. Agencies wishing to give public input may do so at the public hearings held during the budget process. LONG-TERM RESPONSE The Human Services Advisory Committee will continue to refine the funding process following the first fully electronic process. Two places to make improvements are: 1) the online electronic application working with E-Gov Alliance and the other cities; and 2) the local process, rating tool and results. A survey will be done of the agencies that applied for funding to measure satisfaction with the process and to get input on how it can be improved. CONCLUSION Human Services funds are allocated by clearly defined, equitable process. At the current level of funding, the top rated applications are recommended for General Fund and CDBG public services funding. Out of the estimated CDBG Capital funding, $200,000 will be allocated to the City of Renton Housing Repair Assistance Program. The estimated amount Renton will receive for Planning and Administration is $52,952. This is applied to the cost of the CDBG contract specialist’s salary and benefits. Attachments cc:Jay Covington, Chief Administrative Officer 7f. ‐ Community Services Department recommends approval of the  revised 2010 and the 2011/2012 Community Development Block Grant Page 56 of 146 7f. ‐ Community Services Department recommends approval of the  revised 2010 and the 2011/2012 Community Development Block Grant Page 57 of 146 H:\Human Services\09\Legislative\10 Issue Papers\2011-2012 CDBG Contingency Plan final.doc CITY OF RENTON 2011/2012 Community Development Block Grant Contingency Plan for Funding Community Development Block Grant (CDBG) Funding Public Services Programs Increase in CDBG Public Services: ·Increase will be applied proportionately to the Institute for Family Development and the Multi-Service Center. Decrease in CDBG Public Services: ·Decrease funding will be applied proportionately to the Institute for Family Development and the Multi-Service Center. Capital Projects Increase in capital funding: ·Additional funds to Renton Unallocated Fund. Decrease in capital funding: ·Decrease Renton Housing Repair Assistance Program. Planning and Administration Planning and Administration covers administrative costs for Renton’s CDBG program. CDBG covers approximately 56% of the salary and benefit costs of the Contract Specialist and the General Fund the remaining 44%. Increase in funding ·Increase Planning and Administration to cover CDBG administrative activities and additional planning activities which might include developing a Consolidated Plan, needs assessments or capacity building. Decrease in funding ·Decrease funding first to additional planning activities, and then to CDBG administrative and planning activities. 7f. ‐ Community Services Department recommends approval of the  revised 2010 and the 2011/2012 Community Development Block Grant Page 58 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: 2011-2012 General Fund Human Services Funding Recommendations Meeting: Regular Council - 20 Sep 2010 Exhibits: Issue Paper Draft 2011 Agency Funding 2011-2012 Gen Fd Contingency Plan Application Rating Tool Submitting Data: Dept/Div/Board: Community Services Staff Contact: Karen Bergsvik Recommended Action: Refer to Finance Committee Fiscal Impact: Expenditure Required: $ $437,000 Transfer Amendment: $ Amount Budgeted: $ $437,000 Revenue Generated: $ Total Project Budget: $ $437,000 City Share Total Project: $ SUMMARY OF ACTION: Applications for the 2011/2012 funding allocations were read and scored by the Human Services Advisory Committee. They recommended that 35 programs be funded at the current general fund level of $437,000. The General Fund recommendations are informational only, and will be adopted as part of the City's budget process. A contingency plan for increased funding or a decrease in funding is also included. There will be two public hearings for the budget, and agencies will be invited to give comments. STAFF RECOMMENDATION: Include the 2011/2012 general fund human services funding recommendations and contingency plan as part of the 2011-2012 City budget. 7g. ‐ Community Services Department recommends approval of the  2011/2012 General Fund Human Services funding allocation  Page 59 of 146 h:\human services\09\legislative\10 issue papers\issuepaper1112cdbg funding no specifics91310ca.doc COMMUNITY SERVICES DEPARTMENT M E M O R A N D U M DATE:September 13, 2010 TO:Don Persson, Council President, and Renton City Councilmembers VIA:Denis Law, Mayor FROM:Terry Higashiyama, Community Services Administrator STAFF CONTACT:Karen Bergsvik, Human Services Manager, X6652 SUBJECT:2011-2012 General Fund Human Services Funding Recommendations 2011/2012 ISSUES 1.Should the highest ranked applications by result for human services funding for 2011/2012 be funded? 2.During the budget process, approve the 2011/2012 General Fund Human Services funding recommendations and Contingency Plan. BACKGROUND ·Renton chose to participate with 16 other cities in an electronic application administered by E-Gov Alliance. The process saved agencies time by having to submit only one application to apply to any number of the participating cities, which significantly increased the number of requests submitted. ·Two funding workshops were held for agencies in East and South King County. Extensive help was made available to agencies to complete the application-both regionally and locally. ·Facing increased human services needs (requests of $1,177,560) and limited funds to allocate ($489,952 total, of which $437,000 is the general fund, and $52,592 is Community Development Block Grant Public Services), the Committee had to make some very difficult decisions in a highly competitive funding cycle. ·Funding is allocated by Renton Result area. The nine areas are: 1) All children and youth are ready for educational success, work and life; 2) Individuals have adequate clothing, food, housing and healthcare; 3) All individuals become as self-sufficient as possible; 4) Residents know about domestic violence and how to keep safe; 5) All residents are proactive to issues of sexual assault and sexual violence; 6) All residents are healthy and safe; 7) All residents identify with and contribute to their community; 8) End homelessness in Renton; and 9) Connect 7g. ‐ Community Services Department recommends approval of the  2011/2012 General Fund Human Services funding allocation  Page 60 of 146 Don Persson, Council President Renton City Councilmembers Page 2 of 3 September 13, 2010 h:\human services\09\legislative\10 issue papers\issuepaper1112cdbg funding no specifics91310ca.doc people to services. ·Each Result has a specific dollar amount to allocate, based on a percentage of the total amount of funds available to allocate. The percentage is based on the applications received, historical funding levels, and input from the Human Services Advisory Committee (HSAC). Two result areas received no applications. ·The HSAC used a transparent review process that was thorough and equitable. Applications were read and scored by teams of Advisory Committee members, using a rating tool developed by members and staff. Training was provided on how to rate the applications, and each group was supported by a team lead. ·Funding recommendations were based on the points each application received from the scoring process. Applications in a result area ranked from highest to lowest based on the average score of the HSAC raters. Staff rated the accuracy of the financial tables included in the applications, using criteria established by the Human Services Advisory Committee. Currently funded agencies were eligible for five bonus points for meeting contract goals, and submitting reports on time. ·HSAC members divided into four groups to review all the applications in their assigned result areas. Each group read, rated, and made funding recommendations for their results. Funding recommendations by the four groups were reviewed, discussed, and adopted by the entire HSAC. ·HSAC decided that each result would receive funding, and that the top ranked program within each result would be funded, at a minimum, to its 2010 funding level. Programs were funded in the order they were ranked, and programs could not be skipped to fund a lower ranked program. ·The Contingency Plan for additional funds for a decrease in funding is attached. ·General Fund funding recommendations are an informational item only. The recommendations will be adopted through the budget process. Agencies wishing to give public input may do so at the public hearings held during the budget process. 7g. ‐ Community Services Department recommends approval of the  2011/2012 General Fund Human Services funding allocation  Page 61 of 146 Don Persson, Council President Renton City Councilmembers Page 3 of 3 September 13, 2010 h:\human services\09\legislative\10 issue papers\issuepaper1112cdbg funding no specifics91310ca.doc LONG-TERM RESPONSE The Human Services Advisory Committee will continue to refine the funding process following the first fully electronic process. Two places to make improvements are: 1) the online electronic application working with E-Gov Alliance and the other cities; and 2) the local process, rating tool, and results. A survey will be done of the agencies that applied for funding to measure satisfaction with the process and to get input on how it can be improved. CONCLUSION Human Services funds are allocated by a clearly defined, equitable process. At the current level of funding, the top rated applications are recommended for General Fund and CDBG public services funding. Attachments cc: Jay Covington, Chief Administrative Officer 7g. ‐ Community Services Department recommends approval of the  2011/2012 General Fund Human Services funding allocation  Page 62 of 146 7g. ‐ Community Services Department recommends approval of the  2011/2012 General Fund Human Services funding allocation  Page 63 of 146 C:\Documents and Settings\callread\Local Settings\Temporary Internet Files\Content.Outlook\1XK1LO1F\2011-2012 General fund contingency plan.doc CITY OF RENTON 2011/2012 General Fund Contingency Plan for Funding General Fund Increase in the general fund allocation: Additional funds will be distributed by the same percentages per result area as the initial funds: Result One: 19.78% Result Two: 17.08% Result Three: 8.32% Result Four: 8.58% Result Five: 6.38% Result Eight: 29.87% Result Nine: 10% Each team that was assigned to each result area will decide how to distribute the funds within their result area. If a result area receives more than $5,000 (the minimum level of funding), the team can choose to fund a new program. Decrease in general fund allocation: A decrease in funding will be applied to each result area by the same percentages as above. Each team that was assigned to each result area will decide how to cut funds within their result area. No program will be cut below $5000 (the minimum level of funding). 7g. ‐ Community Services Department recommends approval of the  2011/2012 General Fund Human Services funding allocation  Page 64 of 146 CITY OF RENTON APPLICATION RATING TOOL __________ __________ POINT ALLOCATION High (5): Moderate (3): Low (1): Incomplete (0): SUMMARY OF SCORES / 50 / 30 / 15 / 5 / 100 The answer does not adequately address a number of the key points. The answer does not address the question. Comments: Performance History Need: Outputs/Outcomes: Financial: TOTAL: The answer addresses all elements listed with responses that are complete and relevant. The answer addresses: 1) Most but not all elements listed, OR 2) All elements listed but answers are not as complete and relevant as other responses. 7g. ‐ Community Services Department recommends approval of the  2011/2012 General Fund Human Services funding allocation  Page 65 of 146 CITY OF RENTON APPLICATION RATING TOOL Corresponding Application Question High (5) Moderate (3) Low (1) Incomplete (0) D1 D2a D2b D2c D2d D3, D4 A1a-d A1e-f A2, A3 C1a Corresponding Application Question High (5) Moderate (3) Low (1) Incomplete (0) SU1-3 SU1-3, OP1-2 OP3 OT1 OT2 OT3 Program does not duplicate existing services to Renton residents, or describes how the program differs in service delivery to the target population. Provides a clear description of the problem and recent regional or sub- regional data. The program addresses the identified need(s) and is fully described. The core components of the program are clearly defined and relevent to the exisiting need(s) and include any best or promising practices being The target population is clearly identified including demographic and geographic details and relevent to the existing need(s). The capacity and strategies for providing immediately available services are clearly defined and relavent to the need. Subtotals:TOTAL OUTPUT/OUTCOMES SCORE: OUTPUTS/OUTCOMES (30 points) TOTAL NEED SCORE: The capacity and strategies to serve individuals with cultural barriers (including language, literacy, or background) is clearly defined and relevent to the need. Subtotals: Clearly demonstrates the agency is able to successfully manage the program, and the proper staff is in place. Accessibility (15/55 points) Describes how the program is accessible in terms of location, affordability, physical accessibility and communications for persons with disabilities and limited English speakers, and is relevent to the need. Service Units & Outputs (15/30 points) Coordination (5/50 points) NEED (50 points) Description (30/55 points) How and when the services are provided are clearly defined and relevent to the identified target population. Outcomes (15/30 points) Effectiveness of the program is measurable and clearly defined. The desired timeframe for results is measurable, clearly defined and in line with the program's desired outcomes. Proposed 2011 outcomes are measurable and clearly defined. Service units are well defined and relavent to the proposed program (e.g. Crisis lines measure number of calls, food banks measure bags of food provided). Significant changes in service units were explained if applicable. Cost per unit of services is reasonable/consistent for the types of services (taking into account the intensity and durations of program and the clients' needs). 2011/2012 service estimates are clearly defined, correlate to the requested funding, and are in-line with service costs for other cities. 7g. ‐ Community Services Department recommends approval of the  2011/2012 General Fund Human Services funding allocation  Page 66 of 146 CITY OF RENTON APPLICATION RATING TOOL FINANCIAL (15 points) /Performance History (5 points) completed by staff 7g. ‐ Community Services Department recommends approval of the  2011/2012 General Fund Human Services funding allocation  Page 67 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: King County Metro Transit Transit Now Service Partnership Route 110 Agreement Addendum Meeting: Regular Council - 20 Sep 2010 Exhibits: Issue Paper Contract Resolution Submitting Data: Dept/Div/Board: Public Works Staff Contact: Nathan Jones, Planning Section (extension 7217) Recommended Action: Council Concur Fiscal Impact: Expenditure Required: $ $ 199,743.57/year beginning in 2013 Transfer Amendment: $0 Amount Budgeted: $ Revenue Generated: $0 Total Project Budget: $ City Share Total Project: $ $ 998,717.85 (5-year total) SUMMARY OF ACTION: In 2008, Renton signed a five-year agreement CAG-08-194 with King County Metro Transit to provide funding for enhanced service and routing on Metro Route 110. With projected declines in City revenues, and despite potential benefits of increased service, in September 2009 City Council authorized the Mayor to send a letter to King County notifying Metro of the City’s intent to terminate financial support of the Transit Now Route 110 partnership. Subsequent communication with King County Metro Transit staff indicated it is possible to delay the implementation of this route until 2013, when potential City revenues may have rebounded. STAFF RECOMMENDATION: Adopt the Resolution which rescinds the September 14, 2009, termination of CAG-08-194 and authorizes the Mayor to sign an addendum for the Metro Route 110 Transit Now agreement delaying service implementation to 2013. 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 68 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 69 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 70 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 71 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 72 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 73 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 74 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 75 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 76 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 77 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 78 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 79 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 80 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 81 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 82 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 83 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 84 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 85 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 86 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 87 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 88 of 146 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 89 of 146 CITY OF RENTON, WASHINGTON RESOLUTION NO. A RESOLUTION OF THE CITY OF RENTON, WASHINGTON, RESCINDING THE TERMINATION OF THE INTERLOCAL AGREEMENT WITH KING COUNTY METRO TRANSIT REGARDING THE KING COUNTY METRO ROUTE 110 PARTNERSHIP AGREEMENT AND AUTHORIZING THE MAYOR AND CITY CLERK TO ENTER INTO AN ADDENDUM TO THE AGREEMENT. WHEREAS, on December 1, 2008, the City Council passed Resolution No. 3987, authorizing the Mayor and City Clerk to enter into an Interlocal Agreement with King County Metro Transit regarding the King County Metro Route 110 Partnership Agreement (the "Agreement"); and WHEREAS, on September 14, 2009, the City Council approved the Transportation Systems Division request to terminate the Agreement in light of budget shortfalls for 2009 and 2010; and WHEREAS, in later discussions, King County and the City agreed to push back implementation ofthis Agreement to a date in the future beyond the original implementation date of September 2010; and WHEREAS, as the City Council had already approved termination of the Agreement, the implementation date could not be amended unless the termination was rescinded; NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF RENTON, WASHINGTON, DOES RESOLVE AS FOLLOWS: SECTION I. The above recitals are found to be true and correct in all respects. SECTION II. The City Council hereby rescinds the termination of the Agreement. SECTION III. The Mayor and City Clerk are hereby authorized to enter into an amendment to the Agreement for the purpose of changing the implementation date. 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 90 of 146 RESOLUTION NO. PASSED BY THE CITY COUNCIL this day of , 2010. Bonnie I. Walton, City Clerk APPROVED BY THE MAYOR this day of , 2010. Denis Law, Mayor Approved as to form: Lawrence J. Warren, City Attorney RES.1479:9/2/10:scr 7h. ‐ Transportation Systems Division recommends rescinding the  termination of CAG‐08‐194, with King County Transit, and approval of an Page 91 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: 126th Avenue SE Sanitary Sewer Extension Special Assessment District No. 0045 Meeting: Regular Council - 20 Sep 2010 Exhibits: Issue Paper Ordinance Draft Final Notice of Potential Assessment Final Assessment District Roll Submitting Data: Dept/Div/Board: Public Works Staff Contact: Michael Benoit, Wastewater Engineering, x7206 Recommended Action: Refer to Utilities Committee Fiscal Impact: Expenditure Required: $ N/A Transfer Amendment: $ Amount Budgeted: $ Revenue Generated: $ Total Project Budget: $ City Share Total Project: $ SUMMARY OF ACTION: The Wastewater Utility has completed construction of the 126th Avenue SE Utility project, a portion of which included the 126th Avenue SE Sanitary Sewer Extension. At the regular Council meeting on October 26, 2009, Council approved the preliminary Special Assessment District. The final costs and assessments have been determined, and the property owners will be notified, as directed by City Code. There are potentially 40 single-family units within the Special Assessment District. The per unit assessment for the district is $8,686.39. Thirty days after final approval of the ordinance, interest will accrue on the assessments at a rate of 1.33 percent for a period of 10 years, per City Code. STAFF RECOMMENDATION: Approve the final 126th Avenue SE Sanitary Sewer Extension Special Assessment District No. 0045 and present the ordinance for first reading. 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 92 of 146 PUBLIC WORKS DEPARTMENT M E M O R A N D U M DATE:September 7, 2010 TO:Don Persson, President Members of the Renton City Council VIA:Denis Law, Mayor FROM:Gregg Zimmerman, Public Works Administrator STAFF CONTACT:Michael Benoit, Wastewater Utility, ext 7206 SUBJECT:Establishment of 126th Avenue SE Sanitary Sewer Extension Special Assessment District No. 0045 ISSUE: Does the City wish to establish a Special Assessment District for the 126th Avenue SE Sanitary Sewer Extension in order to ensure that the cost of the project is equitably distributed to those who benefit? RECOMMENDATION: Approve the final 126th Avenue SE Sanitary Sewer Extension Special Assessment District No. 0045 and present the ordinance for first reading. BACKGROUND SUMMARY: The 126th Avenue SE Sanitary Sewer Extension will provide sanitary sewer service to properties adjacent to 126thth Avenue SE between SE 100th Street and SE 104th Street. The Wastewater Utility has proposed to use a per-connection method of calculating the assessments for the properties within the proposed assessment district. This method divides the cost of the project by the number of potential lots within the assessment district. The total final cost of the project was $347,455.53. There are 40 projected lots within the proposed assessment district boundary. Therefore, the per connection cost is proposed to be $8,686.39 per unit. The cost estimate as provided for the preliminary approval of the assessment district by Council on October 26, 2009 and shown in the preliminary notice sent out to the property owners was $10,979.09 per unit. The lower final cost was due to favorable construction bids leading to a lower construction cost. 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 93 of 146 Mr. Persson, Council President Page 2 of 2 September 7, 2010 H:\File Sys\WWP - Wastewater\WWP-27-3514 126th Ave SE Sewer Extension\SAD\Final SAD\Final_SAD_Issue_126th.Doc\MABtp Thirty days after final approval of the ordinance, interest will accrue on the assessments at a rate of 1.33 percent for a period of 10 years, per City Code. CONCLUSION: It has been the policy of the City that when sanitary sewer facilities have been installed that the City hold a Special Assessment District in order to ensure each property that benefits from the new facility pays its fair share of the costs. This policy helps ensure the existing ratepayers do not pay a disproportionate share of the costs for these City-installed facilities. Therefore, we recommend that Council approve staff’s recommendation for the establishment of the 126th Avenue SE Sanitary Sewer Extension Special Assessment District No. 0045. cc:Lys Hornsby, Utility Systems Director Dave Christensen, Wastewater Engineering Supervisor JoAnn Wykpisz, PW Principal Financial & Administrative Analyst File 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 94 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 95 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 96 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 97 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 98 of 146 H:\File Sys\WWP - WasteWater\WWP-27-3514 126th Ave SE Sewer Extension\SAD\Final SAD\Final_notice_126TH.doc\MABtp CITY OF RENTON FINAL NOTICE OF POTENTIAL ASSESSMENT for City of Renton 126TH Avenue SE Sanitary Sewer Extension Special Assessment District No. 0045 Date Mailed: October XX, 2010 Per Unit Assessment $8,686.39 Name Street Address City, State Zip King County Account No. LEGAL DESCRIPTION: On November 6, 2009, I, Bonnie I. Walton, the City Clerk of Renton, Washington, mailed you a notice of potential assessment for sanitary sewer improvements associated with the 126th Avenue SE Sanitary Sewer Extension. We have now completed construction of these sewer facilities. The facilities, as shown on the attached map, are eligible for cost recovery under City Special Assessment District Ordinance No. 4444. For those properties that could receive benefit directly by the sewers, future use would trigger payment of a 'fair share' cost of the sewer. This assessment is calculated, as a unit charge, by dividing the cost of the sewer extension by the number of units projected for the basin served by these sewers. This rate has been established at $8,686.39 per unit. The purpose of the assessment district is to allow the City the ability to collect the costs of the construction of the sewer facilities from all those who benefit from its construction. To accomplish this, we are required to record an ordinance which will serve as a notice of potential assessment. This ordinance will establish a boundary that includes any parcel that may benefit in the future. It is our goal to ensure, in fairness to all, that any property owner that connects at a later date pays their share just like those who will connect right away. The benefit area is defined as the ultimate service area that the facility may be able to serve. This boundary is shown on the attached map. You will only be required to pay this assessment when the property gains benefit from these sewer facilities. Until that time, the property can be sold or change hands without triggering the assessment. Benefit from these sewer facilities can be described as follows: ·A property not currently connected to a City sewer facility (i.e., currently utilizing an on-site system or a vacant parcel), that connects to the sewer system associated with this district will trigger the assessment. Until then, the assessment will not be triggered. ·For those properties that are already connected to City sewer, this assessment will only be triggered if the property increases its density either by change of use (i.e., single family to multi-family housing) or through increased density within the same use (i.e., further subdivision of land for single family housing). You will not be required to pay the assessment unless one of the above situations occurs. However, the assessment district will accrue simple interest at a rate of 1.33% per annum for a period of ten years. The accrual of interest will begin thirty (30) days after the notice of potential assessment is recorded with King County Records. To avoid interest charges at a future date, you may pay the 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 99 of 146 H:\File Sys\WWP - WasteWater\WWP-27-3514 126th Ave SE Sewer Extension\SAD\Final SAD\Final_notice_126TH.doc\MABtp amount of assessment during the thirty-day period after recording, interest free. This option is totally at the discretion of the property owner. Some properties within the boundary of this special assessment district are currently within other city held special assessment districts. Each property will only be responsible to pay the charges for the special assessment districts that they derive benefit from. Per City Ordinance No. 4444 you may request an appeal hearing by writing to the Renton City Council, c/o City Clerk, 1055 S. Grady Way, Renton, WA 98057, within twenty (20) days of this mailing (by October XX, 2010, 5:00 P.M.). Grounds for protest: An appeal shall include a statement of claimed errors that concern the proposed assessment and must be accompanied by a $75.00 non-refundable fee. Errors which are not set forth in writing will not be considered. Pursuant to City Ordinance No. 4444, Sections 9-16-9.C and D, the only items of appeal that will be considered are the cost of the facilities, the costs distribution methodology, and the issue of benefit to the properties to be assessed Appeal Fee and Appeal Process: A non-refundable appeal fee in the amount of $75.00 shall be submitted with each appeal. If a protest is received and deemed timely and establishes proper grounds for protest according to City Ordinance, a public hearing will be held. If no protests are received, the above-quoted notice of potential assessment will be recorded against your property. The charge(s) will not be collected until you subsequently tap onto or use the facilities covered by the Special Assessment District notice. We hope that this notice will answer most of your questions. If you do, however, have questions pertaining to sewer installations, the background of the assessment district, or the appeal process, please contacts Michael Benoit (primary) at 425-430-7206 or Dave Christensen (secondary) at 425-430-7212. ________________________________ Bonnie I. Walton, City Clerk Notice of Final Assessment/Final Hearing 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 100 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 101 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 102 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 103 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 104 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 105 of 146 7i. ‐ Utility Systems Division requests authorization to finalize the 126th  Ave. SE Sanitary Sewer Extension Special Assessment District in the Page 106 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: 2011 and 2012 Utility Revenue Requirements and Rates Meeting: Regular Council - 20 Sep 2010 Exhibits: Issue Paper 2011 Utility Rate Comparison Submitting Data: Dept/Div/Board: Public Works Staff Contact: Lys Hornsby, Utility Systems Director, x7239 Recommended Action: Refer to Committee of the Whole Fiscal Impact: Expenditure Required: $ Transfer Amendment: $ Amount Budgeted: $ Revenue Generated: $Water $2,012,487 (2011), $2,117,208 (2012) Total Project Budget: $ City Share Total Project: $ SUMMARY OF ACTION: Using the utility rate model and the new financial criteria, staff determined the utility revenue requirements for 2011 and 2012. The primary factors that are driving the need for a revenue increase include meeting the financial polices – covering debt, system reinvestment, reserves and rate stabilization, and maintaining sustainable fund balances. The recommended revenue increases for 2011 are 18 percent for water, 42 percent for wastewater, 40 percent for surface water, and no increase for solid waste. The recommended revenue increases for 2012 are 16 percent for water, 5 percent for wastewater, 11 percent for surface water, and no increase for solid waste. Implementing the proposed 2011 and 2012 rates will allow the utilities to provide the minimum required maintenance, compliance with minimum regulatory requirements and meet minimum financial policies and fund balances. STAFF RECOMMENDATION: Approve the proposed rate increases as outlined in the attached issue paper and direct staff to prepare appropriate legislation. 7j. ‐ Utility Systems Division submits proposed changes to the water,  wastewater, and surface water utility rates. Refer to Committee of the Page 107 of 146 PUBLIC WORKS DEPARTMENT M E M O R A N D U M DATE:September 8, 2010 TO:Don Persson, Council President Members of Renton City Council VIA:Denis Law, Mayor FROM:Gregg Zimmerman, Administrator STAFF CONTACT:Lys Hornsby, Utility Systems Director, x 7239 SUBJECT:2011 and 2012 Utility Revenue Requirements and Rates ISSUE: Should Council approve the proposed 2011 and 2012 utility revenue increases? RECOMMENDATION: ·Approve the proposed 2011 revenue increases of 18 percent for water, 42 percent for wastewater, 40 percent for surface water and no increase for solid waste. ·Approve the proposed 2012 revenue increases of 16 percent for water, 5 percent for wastewater, 11 percent for surface water and no increase for solid waste. ·Maintain the current $1.16 King County rate stabilization charge for both 2011 and 2012. ·Direct staff to prepare the ordinances allowing the City to charge the 2011 utility rates beginning January 1, 2011, and to charge the 2012 utility rates beginning January 1, 2012. BACKGROUND SUMMARY: Over the past 15 years, City utilities have placed a high priority on accommodating growth and economic development, while keeping rates low. This is in accordance with the City’s Six-Year Business Plan. This approach has resulted in significant benefits to the City. Utility funded capital improvement projects to increase system capacity and accommodate growth and development have supported such projects as The Landing, Harrington Square, Seahawks facility and downtown development. These improvements will continue to support significant future development including Hawk’s Landing, Highlands Area, and further redevelopment downtown. While the City utilities were completing these projects and keeping rates and fees low (and waiving fees in some cases), our composite utility rates became the lowest among all neighboring utility 7j. ‐ Utility Systems Division submits proposed changes to the water,  wastewater, and surface water utility rates. Refer to Committee of the Page 108 of 146 Mr. Don Persson, Council President Page 2 of 3 September 8, 2010 \\RVFPS-02\Depts\PW\File Sys\USA - Utility Systems Division Administration\USA-03 - CORRESPONDENCE\USA-03 - 0001 Utility Director's Correspondence\2011 Budget\2011 2012 Rates Issue Paper.doc\LLHtp providers. Over the years, this approach has resulted in some negative consequences for the utilities. Projects to accommodate development and growth have been prioritized over projects to maintain existing infrastructure. In some cases, systems have started to deteriorate and fail (Earlington, Cascade Interceptor, and President Park). Our approach of prioritizing development projects, and keeping rates and fees low, has caused the utilities to rely more heavily on bonds over rate revenue and made it difficult to maintain necessary reserves and fund balances. Compounding these financial challenges, revenues have dropped due to the weak economy and conservation efforts. These factors have combined over time to place the utilities in a vulnerable financial condition. Earlier this year, Council adopted financial criteria to stabilize the utility funds and directed that the criteria be implemented over a five-year period starting in 2011. The financial criteria include: ·Fund Balance, Operating Reserves, and Rate Stabilization: o Water, Wastewater and Surface Water Funds: 12% of annual operating expenses or 30 to 45 days o Solid Waste: $400,000 o King County Wastewater Treatment: $380,000 ·Capital Contingency as System Reinvestment and Debt Service: o Surface Water: 1.25 debt service coverage (DSC) and approximately $3 million annual system reinvestment o Wastewater: 1.25 DSC and approximately $3 million annual system reinvestment o Water: 1.25 DSC and approximately $4 million annual system reinvestment Bonds versus Cash Funded Projects ·All non-CIP projects should be paid for using rates (programs, system plans, education materials, etc.). ·All system reinvestment, maintenance, replacement and rehabilitation CIPs should be paid for using rates. ·CIPs for new infrastructure, growth, or increased capacity can be paid for using bonds. Piped Utilities Rate Modeling To meet the financial criteria in five years and minimize rate increases in 2011 and 2012, additional system reinvestment funding was phased-in starting in 2013. The Capital Improvement Program (CIP) was kept as low as possible in 2011 and 2012, and moderate bonding was used in 2011 and 2012 in the wastewater utility modeling to smooth rates over the transition period. The proposed five-year revenue needs forecast below meets the financial criteria by the 2016 budget year if revenue increases are approved for the 2011 through 2015 period. 7j. ‐ Utility Systems Division submits proposed changes to the water,  wastewater, and surface water utility rates. Refer to Committee of the Page 109 of 146 Mr. Don Persson, Council President Page 3 of 3 September 8, 2010 \\RVFPS-02\Depts\PW\File Sys\USA - Utility Systems Division Administration\USA-03 - CORRESPONDENCE\USA-03 - 0001 Utility Director's Correspondence\2011 Budget\2011 2012 Rates Issue Paper.doc\LLHtp Increase on Average Monthly Single-Family Bill Utility 2011 2012 2013 2014 2015 Water % increase $4.63 18% $4.85 16% $2.11 6% $2.24 6% $2.37 6% Wastewater % increase $7.06 42% $1.20 5% $1.25 5% $1.32 5% $1.38 5% Surface Water % increase $2.96 40% $1.14 11% $0.58 5% $0.60 5% $0.63 5% Solid Waste % increase $0 0% $0 0% $0 0% $0 0% $0 0% Total Proposed Increase/mo $14.65 $7.19 $3.94 $4.16 $4.38 Average Monthly Single-Family Bill with Proposed Increases Utility 2011 2012 2013 2014 2015 Water $30.34 $35.19 $37.30 $39.54 $41.91 Wastewater $23.88 $25.08 $26.33 $27.65 $29.03 Surface Water $10.37 $11.51 $12.09 $12.69 $13.32 Solid Waste $19.15 $19.15 $19.15 $19.15 $19.15 Total $83.74 $90.93 $94.87 $99.03 $103.41 The average single-family monthly utility bill is $83.74 for 2011 and $90.93 for 2012. Of the nine cities that we use for rate comparisons, only two may have lower rates than Renton in 2011 and 2012. Renton continues to have utility rates in the lowest quarter for the entire region. CONCLUSION: Implementing the proposed 2011 and 2012 revenue increases will allow the utilities to balance debt with cash financing, invest in existing infrastructure to prevent deterioration, failure and/or lapse in service, build adequate fund balance for sustainability, phase in meeting the financial policies, and meet minimum regulatory compliance. cc: JoAnn Wykpisz, PW Prin & Fin Admin Analyst Iwen Wang, FIT Administrator File 7j. ‐ Utility Systems Division submits proposed changes to the water,  wastewater, and surface water utility rates. Refer to Committee of the Page 110 of 146 RANK CITY/ DISTRICT (Solid Waste Provider)TOTAL WATER WASTE WATER Sewer SURFACE WATER Storm SOLID WASTE Garbage 1 *Seattle 116.81 40.76 34.78 8.58 32.70 2 Kirkland (WM)109.61 37.20 26.08 14.86 31.47 3 Coal Creek Utility District (WM)104.24 38.35 17.06 16.62 32.21 4 *Bellevue (A)102.80 37.04 29.71 17.26 18.79 5 *Cedar River Water/Sewer District (A)94.01 32.64 19.55 16.29 25.53 6 Kent (A)91.19 36.75 12.99 * 11.57 29.88 * 7 *Redmond (WM)87.52 45.80 12.32 16.56 12.84 8 Issaquah (WM & A) 69.06 36.98 18.01 14.08 18.07 * 9 RENTON (WM) 83.74 30.34 23.88 10.37 19.15 10 Tukwila (A - SEATAC DISP) 80.77 34.85 15.40 7.79 22.73 11 Auburn (WM, A)78.81 26.06 13.36 14.18 25.21 2011 Utility Rate Comparison With Surrounding Jurisdictions Average Monthly Bill for a Single Family Household DRAFT * 2010 Rates, 2011 Proposed rate increases are unavailable at this time. Notes: The Water and Sewer Districts of Cedar River and Coal Creek provide water and wastewater services only. Surface water is billed by King County. Water: Rates were based on bimonthly consumption of 1,500 cubic feet of water (Seniors 900 cf) . Seattle, Kent, and Tukwila have different water rates in the summer (June -September); the average monthly rates for summer and non-summer months were weighted. Wastewater:Rates for Bellevue, Issaquah, and Seattle were based on a volume of 750 cubic feet per month. All other districts are on a fixed monthly charge. Rates do not include the King County Wastewater Treatment charge. Surface Water: Bellevue's rate is an average rate based on a 10,000 -12,000 sq. ft. lot area (between 20% and 40% developed). Kent's rate depends on the drainage basin affected, ranging from $2.67 to $7.62 per month; for comparison purposes, rates were averaged. Solid Waste: The name of the hauler is noted after the jurisdiction name: "WM" represents Waste Management, "A" represents Allied Waste Services. For comparison purposes, rates include a 32-gallon garbage can, recycling, yard waste collection, and an $0.80/month hazardous waste fee. Seattle and Renton do not charge a hazardous waste fee. Coal Creek and Issaquah use two hauling companies to collect garbage; for comparison purposes, the jurisdiction's two rates were averaged. \\RVFPS-02\Depts\PW\File Sys\USA - Utility Systems Division Administration\USA-03 - CORRESPONDENCE\USA-03 - 0001 Utility Director's Correspondence\2011 Budget\2011 Utility Rate Comparison.xls RATES 09/13/2010 7j. ‐ Utility Systems Division submits proposed changes to the water,  wastewater, and surface water utility rates. Refer to Committee of the Page 111 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: Residential Plat Stormwater Management Facility Maintenance and Operation Policy Meeting: Regular Council - 20 Sep 2010 Exhibits: Issue Paper Submitting Data: Dept/Div/Board: Public Works Staff Contact: Ron Straka,Surface Water Utility Supervisor, x7248, Steve Lee, Surface Water Engineer, x7205 Recommended Action: Refer to Committee of the Whole Fiscal Impact: Expenditure Required: $ 715,950/year Transfer Amendment: $ Amount Budgeted: $ Revenue Generated: $ Total Project Budget: $ City Share Total Project: $ SUMMARY OF ACTION: The City needs to establish a uniform and equitable policy for maintaining stormwater management facilities in single-family residential plats with public streets. The City currently requires homeowner associations to own and maintain stormwater flow control and water quality treatment facilities in single-family residential plats, even though these facilities manage runoff from public streets. However, when the City annexes areas from King County, the City is required to assume maintenance of stormwater management facilities in the newly annexed areas because King County owns and maintains stormwater facilities in plats with public streets. The Surface Water Utility currently maintains 100 stormwater facilities in plats. There are an additional 213 facilities that are privately maintained by homeowner associations in single-family residential plats that manage runoff from public streets. Because these facilities manage runoff from public right-of-way, the City should maintain these facilities. The proper maintenance of these facilities is also needed to minimize maintenance and capital improvements costs to the City, to meet regulatory requirements related to the National Pollution Discharge Elimination System Phase II Municipal Stormwater Permit, to protect public safety, to prevent damage to property, and to protect environmental resources. Prior to the City assuming maintenance of existing stormwater facilities, the facilities would need to meet City maintenance standards. The total additional revenue increase needed to fund the program would be about $13 per year for a typical homeowner, based upon 2010 Surface Water Utility revenues. That amount could be reduced if proposed revenue increases are approved as part of the 2011-2012 budget process and if the Fairwood Annexation is approved. The hiring of the maintenance staff and budgeting for the purchase and rental of equipment would be phased in between 2012 and 2013, depending upon how rapidly facilities are transferred from homeowner associations to the City. STAFF RECOMMENDATION: Assume maintenance and operation of all stormwater facilities in single-family residential plats with public streets. 7k. ‐ Utility Systems Division recommends assuming maintenance and  operation of all stormwater facilities in single‐family residential plats Page 112 of 146 7k. ‐ Utility Systems Division recommends assuming maintenance and  operation of all stormwater facilities in single‐family residential plats Page 113 of 146 7k. ‐ Utility Systems Division recommends assuming maintenance and  operation of all stormwater facilities in single‐family residential plats Page 114 of 146 7k. ‐ Utility Systems Division recommends assuming maintenance and  operation of all stormwater facilities in single‐family residential plats Page 115 of 146 7k. ‐ Utility Systems Division recommends assuming maintenance and  operation of all stormwater facilities in single‐family residential plats Page 116 of 146 7k. ‐ Utility Systems Division recommends assuming maintenance and  operation of all stormwater facilities in single‐family residential plats Page 117 of 146 7k. ‐ Utility Systems Division recommends assuming maintenance and  operation of all stormwater facilities in single‐family residential plats Page 118 of 146 7k. ‐ Utility Systems Division recommends assuming maintenance and  operation of all stormwater facilities in single‐family residential plats Page 119 of 146 7k. ‐ Utility Systems Division recommends assuming maintenance and  operation of all stormwater facilities in single‐family residential plats Page 120 of 146 CITY OF RENTON COUNCIL AGENDA BILL Subject/Title: FY-2011 Municipal Stormwater Capacity Grant Ecology Grant Agreement No. G1100089 Meeting: Regular Council - 20 Sep 2010 Exhibits: Issue Paper Grant Agreement No. G1100089 Signature Authorization Form for Grant/Loan Recipients Submitting Data: Dept/Div/Board: Public Works Staff Contact: Ron Straka, Surface Water Utility Supervisor, x7248 Recommended Action: Council Concur Fiscal Impact: Expenditure Required: $ 297,940 (2010/2012) Transfer Amendment: $ Amount Budgeted: $ Revenue Generated: $297,940 (2010/2012) Total Project Budget: $ City Share Total Project: $ 0 SUMMARY OF ACTION: The City of Renton is eligible to receive $297,940 in non-matching grant funding between 2010 and 2012 from the Washington State Department of Ecology. This grant will assist the Surface Water Utility and the City to implement the requirements associated with the new NPDES Phase II Municipal Stormwater permit. Surface water activities eligible for this grant funding include the illicit discharge, detection and elimination program, storm system mapping, and municipal operations pollution prevention activities, flow control facilities inspections, public education program, and a monitoring plan. This grant does not require the local government to match and is 100 percent funded by the Washington State Department of Ecology with the effective date of the grant funds provided from July 1, 2010 to June 30, 2012 per the agreement. The amendments to the Surface Water Utility 407 and 427 fund revenue and expenditure budgets for the Ecology FY-2011 Municipal Stormwater Capacity Grant funding will be included in the City’s quarterly budget amendment ordinance, which is prepared by the Finance Division. STAFF RECOMMENDATION: Approve and authorize the Mayor and City Clerk to sign the Ecology Grant Agreement No. G1100089 and the “Signature Authorization Form for Grant/Loan Recipients.” 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 121 of 146 PUBLIC WORKS DEPARTMENT M E M O R A N D U M DATE:September 7, 2010 TO:Don Persson, Council President Members of Renton City Council VIA:Denis Law, Mayor FROM:Gregg Zimmerman, Public Works Administrator STAFF CONTACT:Ron Straka, Surface Water Utility Supervisor, x7248 SUBJECT:FY-2011 Municipal Stormwater Capacity Grant Ecology Grant Agreement No. G1100089 ISSUE: Should the City of Renton enter into a grant agreement with the Washington State Department of Ecology for non-matching grant funds to be used by the City to assist with implementing the Phase II Municipal Stormwater National Pollutant Discharge Elimination System (NPDES) permit? RECOMMENDATION: Approve and authorize the Mayor and City Clerk to sign the Ecology Grant Agreement No. G1100089 and the “Signature Authorization Form for Grant/Loan Recipients.” The amendments to the Surface Water Utility 407 and 427 fund revenue and expenditure budgets for the Ecology FY-2011 Municipal Stormwater Capacity Grant funding will be included in the City’s quarterly budget amendment ordinance, which is prepared by the Finance Division. BACKGROUND: This grant will assist the Surface Water Utility and the City to implement the requirements associated with the new NPDES Phase II Municipal Stormwater permit. Surface water activities eligible for this grant funding include the implementation of the illicit discharge, detection and elimination program, and municipal operations pollution prevention activities, flow control facilities inspections, public education program, storm system mapping, and a monitoring plan. This grant does not require the local government to match and is 100 percent funded by the Washington State Department of Ecology with the effective date of the grant funds provided from July 1, 2010 to June 30, 2012 per the agreement. The amendments to the Surface Water Utility 407 and 427 fund revenue and expenditure budgets for the Ecology FY-2011 Municipal Stormwater Capacity Grant funding will be included in the City’s quarterly budget amendment 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 122 of 146 Mr. Don Persson, Council President Page 2 of 2 September 7, 2010 H:\File Sys\SWP - Surface Water Projects\SWP-27 - Surface Water Projects (CIP)\27-3058 2003 NPDES Phase II Permit\5000 Grants\FY2011 Muni SW Capacity Grant\Grant Authorization\Issue Paper - FY2011 Capacity Grant.doc\EMtp ordinance, which is prepared by the Finance Division. CONCLUSION: The non-matching grant with the Washington State Department of Ecology, in the amount of up to $297,940, would assist the City in complying with the federal NPDES permit. cc: Lys Hornsby, Utilities System Director Edward Mulhern, Surface Water Utility Engineer JoAnn Wykpisz, PW Principal Admin and Fin Analyst File 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 123 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 124 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 125 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 126 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 127 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 128 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 129 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 130 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 131 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 132 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 133 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 134 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 135 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 136 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 137 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 138 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 139 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 140 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 141 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 142 of 146 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 143 of 146 SIGNATURE AUTHORIZATION FORM FOR GRANT/LOAN RECIPIENTS Department of Ecology Water Quality Program PO Box 47600 Olympia, WA 98504-7600 Phone: (360) 407-6600 FAX: (360) 407-7151 Name of Organization Date Submitted City of Renton Project Title Agreement Number FY-2011 Municipal Stormwater Capacity Grant Ecology Grant Agreement No. G1100089 AUTHORIZING SIGNATORY Signature Print Title/Term of Office Denis Law Mayor AUTHORIZED TO SIGN AGREEMENT AMENDMENTS Signature Print Title Ron Straka, P.E.Surface Water Utility Engineer Supervisor Lys Hornsby, P.E.Utility Systems Director AUTHORIZED TO SIGN REQUEST FOR REIMBURSEMENT Signature Print Title Ron Straka Surface Water Utility Supervisor Edward Mulhern Surface Water Utility Engineer 7l. ‐ Utility Systems Division recommends approval to accept $297,940 in  non‐matching grant funds from the Department of Ecology to implement Page 144 of 146 CITY OF RENTON, WASHINGTON RESOLUTION NO. A RESOLUTION OF THE CITY OF RENTON, WASHINGTON, RESCINDING THE TERMINATION OF THE INTERLOCAL AGREEMENT WITH KING COUNTY METRO TRANSIT REGARDING THE KING COUNTY METRO ROUTE 110 PARTNERSHIP AGREEMENT AND AUTHORIZING THE MAYOR AND CITY CLERK TO ENTER INTO AN ADDENDUM TO THE AGREEMENT. WHEREAS, on December 1, 2008, the City Council passed Resolution No. 3987, authorizing the Mayor and City Clerk to enter into an Interlocal Agreement with King County Metro Transit regarding the King County Metro Route 110 Partnership Agreement (the "Agreement"); and WHEREAS, on September 14, 2009, the City Council approved the Transportation Systems Division request to terminate the Agreement in light of budget shortfalls for 2009 and 2010; and WHEREAS, in later discussions, King County and the City agreed to push back implementation ofthis Agreement to a date in the future beyond the original implementation date of September 2010; and WHEREAS, as the City Council had already approved termination of the Agreement, the implementation date could not be amended unless the termination was rescinded; NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF RENTON, WASHINGTON, DOES RESOLVE AS FOLLOWS: SECTION I. The above recitals are found to be true and correct in all respects. SECTION II. The City Council hereby rescinds the termination of the Agreement. SECTION III. The Mayor and City Clerk are hereby authorized to enter into an amendment to the Agreement for the purpose of changing the implementation date. 9a. ‐ Route 110 service partnership agreement with King County Transit  (See 7.h.)Page 145 of 146 RESOLUTION NO. PASSED BY THE CITY COUNCIL this day of , 2010. Bonnie I. Walton, City Clerk APPROVED BY THE MAYOR this day of , 2010. Denis Law, Mayor Approved as to form: Lawrence J. Warren, City Attorney RES.1479:9/2/10:scr 9a. ‐ Route 110 service partnership agreement with King County Transit  (See 7.h.)Page 146 of 146