Loading...
HomeMy WebLinkAboutzR-3899Set1 I 2 I 3 I 4 I 5 I 6 I 7 I 8 I 9 I 10 I 11 I 12 SITE NOTES LEGEND SITE KEY 13 14 15 16 17 1 18 1 19 NW 1/4 OF S 19, T 23 N, R 5 E 0 w LL H O U C/) C O m 2 CU r� 1 E E C H CD 0 N 0 r� Q 0 m z J / CD 0 N Cn > Q K Ln / 0 L m r / 0 L 0 C_ cn 0 / 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY REGULATIONS AND CODES AND O.S.H.A. STANDARDS. 2. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THIS PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON SURVEY PREPARED BY BUSH, ROED & HITCHINGS, INC., DATED OCTOBER 9, 2012. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. 3. CAUTION — NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES AND EXISTING IMPROVEMENTS WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS ON THE PLANS. 4. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF SLOPED PAVING, EXIT PORCHES, SIDEWALKS, RAMPS, PRECISE BUILDING DIMENSIONS AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS. 5. DIMENSIONS SHOWN REFER TO FACE OF CURB, FACE OF BUILDING OR TO THE CENTERLINE OF PAVEMENT STRIPING, UNLESS OTHERWISE NOTED. 6. ALL PAVED PARKING LOT AREAS WITHIN THE LIMITS OF IMPROVEMENTS SHALL BE STANDARD DUTY PAVEMENT UNLESS OTHERWISE NOTED. 7. CONTRACTOR SHALL PROVIDE A TEMPORARY TRAFFIC CONTROL PLAN FOR THE CITY ENGINEER'S APPROVAL PRIOR TO ANY WORK WITHIN THE CITY RIGHT—OF—WAY. 8. ALL ON —SITE PAINTED STRIPING SHALL BE DOUBLE COATED. SEPARATE COATS SHALL BE APPLIED NO SOONER THAN 4 HOURS APART. (CONTRACTOR TO REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL PAVING MARKING REQUIREMENTS.) 9. PARKING LOT STRIPING SHALL BE WHITE, 4" WIDTH, & DOUBLE COATED, UNLESS OTHERWISE NOTED. LIGHT POLE BASES TO BE PAINTED TRAFFIC WHITE (DOUBLE COAT) 10. ALL DISTURBED AREAS ARE TO RECEIVE FOUR INCHES OF TOPSOIL, SEED, MULCH AND WATER UNTIL A HEALTHY STAND OF GRASS IS ESTABLISHED. 11. ALL ISLANDS WITH CURB AND GUTTER SHALL BE LANDSCAPED. EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE ABANDONED, REMOVED OR RELOCATED AS NECESSARY. ALL COST SHALL BE INCLUDED IN BASE BID. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, INCLUDING BUT NOT LIMITED TO, ALL UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS & POLES, ETC. AS REQUIRED. ALL WORK SHALL BE IN ACCORDANCE WITH GOVERNING AUTHORITIES SPECIFICATIONS AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BASE BID. 13. ALL VERTICAL CONSTRUCTION SHALL MAINTAIN 10' MINIMUM SEPARATION FROM OVERHEAD POWER LINES. CONTRACTOR TO NOTIFY ENGINEER IMMEDIATELY IF CONFLICT EXISTS AND PRIOR TO CONSTRUCTION OF THE VERTICAL ELEMENT INCLUDING, BUT NOT LIMITED TO, LIGHT POLE BASES AND TRAFFIC SIGNAL STANDARDS. 14. CONTRACTOR TO SEAL COAT AND PERFORM CRACK REPAIR AS NECESSARY ON EXISTING PAVEMENT TO REMAIN. SITE DATA ZONING COMMERCIAL ARTERIAL (CA) USE DRIVE —THROUGH RESTAURANT = 0.24 AC BUILDING DATA APPROXIMATE BUILDING AREA = 480 SF SETBACKS PER CITY OF RENTON ZONING CODE FRONT = 15' MAX. REAR = 0' SIDE = 0' C �C 0 1505 Westlake Ave. N. Suite 305 Seattle, WA 98109 2\11�� T (206)522-9510 F (206)522-8344 WWW. PAcLAND.COM !�8 �SSIONAL EN�l ■ ■ PROPERTY LINE EXISTING LEASE LINE 0 0 N N 00 I � N PARKING DATA STD. DUTY PAVEMENT c—$.o CONCRETE PAVEMENT 4 c—s.o CONCRETE SIDEWALK 3 PAVEMENT ASPHALT OVERLAY LIFT , CONCRETE CURB & GUTTER NUMBER OF PARKING STALLS PER ROW REQUIRED PARKING = 4 STALLS MIN. STANDARD STALLS PARKING RATIO (PER LEASE AGREEMENT WITH WALMART) = 8.0 / 1,000 SF MIN. PROPOSED PARKING = 2 STALLS STANDARD STALLS = 1 STALL ACCESSIBLE STALLS = 3 STALLS OA AREA STRIPED AT SINGLE WHITE (4") LINES AT 45° @ 2'-0" o.c. © PEDESTRIAN CROSSWALK WITH 4" WIDE PAINTED WHITE STRIPING PARALLEL TO DIRECTION OF TRAFFIC AT 2'-0" O.C. UNLESS NOTED OTHERWISE. SEE SITE PLAN FOR WIDTH. © TRASH ENCLOSURE, SEE ARCH. PLAN FOR DETAILS. OD PEDESTRIAN CROSSING SIGN W11A-2 AND W11A-2P (TYP.) AT 3 PEDESTRIAN CROSSWALKS AS NOTED ON PLANS. ()6"0 PIPE BOLLARD (TYP.), SEE DETAIL. 6 c-s.1 5 OF 18" CONCRETE CURB AND GUTTER (TYP.). © CONCRETE SIDEWALK ltc_:;8�0) O CONCRETE PAVEMENT TOTAL STALLS PROPOSED PARKING RATIO = 6.25 / 1000 SF * REDUCED PARKING ALLOWED PER DEVELOPMENT PLAN APPROVAL FROM WALMART, DATED OCTOBER 26, 2015 Approved by: Approved by: Approved by: Approved by: CITY OF RENTON Date ------------------ Date — — — — — — — — — — — — — — — — — — Date — — — — — — — — — — — — — — — — — — Date are] REVISION SURVEYED: DESIGNED: JAC DRAWN: WL CHECKED: JAC BY DATE APPR APPROVED: JAC CI ACCESSIBLE PARKING SPACE TYPICAL. SEE DETAIL SHEET FOR ACCESSIBLE PARKING SPACE SIZE, SIGN AND SYMBOL 1 c—s.1 ("VAN" -INDICATES VAN ACCESSIBLE SPACE) OJ CURB RAMP DETAIL 6 c—s.o OK PAINTED DIRECTIONAL ARROW (TYP.), SEE DETAIL SHEET c $ © LIGHT POLE BASE (TYP.), SEE ARCH. PLAN FOR DETAILS. . "STOP" SIGN AND 12" STOP BAR (TYP.) MUTCD DIRECTIONAL ARROW, SEE DETAIL. CITY OF RENTON DRIVEWAY DETAIL GRAVEL BED, 2"-4" RIVER ROCK, 6" DEPTH ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDI1ONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON A FIELD VISIT BY PACLAND ON 4/30/2019. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR AND SURVEYOR PROVIDED RECORD INFORMATION. PACLAND CERT ICATON G B __-- DATE � 617 __--- r SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM C TY OF RENTON Planning/Building/Public Works Dept. ® CURB SCUPPER, SEE DETAIL. c—s.o ® CITY OF RENTON SIDEWALK DETAIL 10 LP(40)H1�� _ j I ICI EX. LIGHT POLE PAVEMENT RESTORATION AREA 9 C-8.1 I SAWCUT I I I II II ��I� IIu) IIW D z�� W I >� Q IW 0 II 0 W I LLLJLLJ �I I �I I II I � I APPROX. LOCATION OF I I NEW STREET LIGHT R=38991 0 Know what's below. Call before you dig. GRAPHIC SCALE 10 0 5 10 20 40 ( IN FEET ) 1 inch = 10 ft. DATE4/30/ 19 DUTCH BROS. RECORD DRAWING PAGE: OOK: PAGE: SITE PLAN DRAWING N0: C-1 .0 RENTON, WA SHEET: 5 OF 12 115d017 FC)F50