Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
R-406945
V1 Q0 0 11 I 0 11 GI I••d PROJECT NOTES 1. GENERAL: WORK SHALL BE DONE IN ACCORDANCE WITH CODES 10. SCOPE OF WORK: THE SCOPE OF WORK FOR THIS PROJECT AS ADOPTED BY THE CITY OF RENTON, KING COUNTY, AND THE INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: STATE OF WASHINGTON. A. PERMITS: GIVE ALL NECESSARY NOTICES, OBTAIN ALL 2. WSDOT AND CITY OF RENTON (COR) STANDARDS APPLY TO, AND PERMITS AND PAY ALL GOVERNMENT TAXES, FEES AND ARE MADE PART OF, THIS SCOPE OF WORK. OTHER COSTS IN CONNECTION WITH THIS WORK. OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION OF THE 3. LOCATIONS OF ELECTRICAL EQUIPMENT, DEVICES, LIGHTING WORK AND DELIVER SAME TO THE ENGINEER AT THE TIME FIXTURES, ETC., INDICATED ON CIVIL / STRUCTURAL AND OF SUBSTANTIAL COMPLETION AND BEFORE REQUEST FOR LANDSCAPE PLANS - INCLUDING SECTIONS, ELEVATIONS, NOTES, FINAL PAYMENT. OR OTHER INDICATORS - TAKE PRECEDENCE OVER LOCATIONS SHOWN ON ELECTRICAL DRAWINGS. B. POWER OUTAGES: POWER OUTAGES SHALL BE LIMITED TO THE HOURS OF 6:OOPM TO 7:OOAM WEEKDAYS. OUTAGES 4. REFER TO CIVIL, STRUCTURAL, LANDSCAPE, ETC., DRAWINGS FOR SHALL BE REQUESTED IN WRITING TO THE OWNER 7-DAYS WORK IN OTHER DIVISIONS. INFORMATION CONVEYED WITHIN PRIOR TO THE DESIRED DATE AND TIME. NO OUTAGE SHALL THE ELECTRICAL DRAWINGS ILLUSTRATING OR REFERENCING OCCUR WITHOUT THE PRIOR APPROVAL OF THE OWNERS WORK OF OTHER DIVISIONS IS FOR REFERENCE ONLY. REPRESENTATIVE. OUTAGES SHALL NOT EXCEED (8) SPECIFICATION BY THE RELEVANT DIVISIONS SHALL APPLY. CONSECUTIVE HOURS. 5. GENERAL NOTES ARE SHOWN ON SHEETS MOST RELEVANT TO C. TEMPORARY POWER: PROVIDE TEMPORARY POWER AS SPECIFIC NOTE; HOWEVER, GENERAL NOTES ON EACH SHEET NEEDED BY ALL TRADES DURING THE EXECUTION OF THIS SHALL APPLY IN PRACTICE TO ALL ELECTRICAL DRAWINGS. CONTRACT. 6. NOT ALL COMPONENTS OF THE ELECTRICAL SYSTEMS ARE SHOWN (FOR SIMPLICITY). PROVIDE MATERIALS AND LABOR NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM. 7. STAINLESS STEEL HARDWARE: MATERIALS USED FOR THE MOUNTING AND SUPPORT OF BOXES CABLES, RACEWAYS, LIGHT FIXTURES, OUTLETS, AND OTHER ELECTRICAL EQUIPMENT, SHALL BE 316 STAINLESS STEEL. THIS REQUIREMENT APPLIES TO THE AFOREMENTIONED COMPONENTS WHEN INSTALLED OUTSIDE ABOVE GRADE. 8. LOCATIONS OF ELECTRICAL SYSTEMS COMPONENTS, INCLUDING BUT NOT LIMITED TO, LUMINAIRES, DISTRIBUTION EQUIPMENT, CONDUIT, JUNCTION BOXES, VAULTS, ETC., MAY BE REVISED PRIOR TO CONSTRUCTION. CHANGES MADE BY THE OWNER IN LOCATING ELECTRICAL COMPONENTS OF UP TO THIRTY FEET HORIZONTALLY (AND/OR VERTICALLY) IS A PART OF THIS CONTRACT. CHANGES IN LOCATION MAY BE IMPLEMENTED, AT NO CHARGE TO THE OWNER, WHEN MADE PRIOR TO ROUGH -IN OF EQUIPMENT BEING RELOCATED. 9. COORDINATE LOCATIONS OF ELECTRICAL AND COMMUNICATION CHASES AND CONDUITS WITH OTHER TRADES. ADJUST LOCATIONS AS NECESSARY TO AVOID CONFLICTS. 10. CONDUCTORS SHALL BE LABELED IN JUNCTION BOXES AND AT TERMINATIONS. ABBREVIATIONS A, AMP AMPERES EMT ELECTRICAL METALLIC TUBING LCP LIGHT CONTROL PANEL PNL PANEL AF AMPERE (RATED) FUSES ENCL ENCLOSURE MAX MAXIMUM POE PORT OF EVERETT AFF ABOVE FINISHED FLOOR EOL END OF LINE MCA MINIMUM CIRCUIT AMPERES +,POS POSITIVE AFG ABOVE FINISHED GRADE EPA EFFECTIVE PROJECTED AREA MFR MANUFACTURER PRI PRIMARY AL ALUMINUM (ALLOY) ESPL. ESPLANADE MIN MINIMUM PUD PUBLIC UTILITY DISTRICT ALC AUTOMATED LIGHTING CONTROL EUC ELECTRICAL UTILITY CENTER MISC MISCELLANEOUS READ REQUIRED AS AMPERE (RATED) SWITCH EWC ELECTRIC WATER COOLER MLO MAIN LUGS ONLY RNC RIGID NONMETALLIC CONDUIT ATS AUTOMATIC TRANSFER SWITCH EWH ELECTRIC WATER HEATER MTD MOUNTED (PVC) AUTO AUTOMATIC FA FIRE ALARM MOB MARINE OPERATIONS BUILDING RR REMOVE AND REPLACE AUX AUXILIARY FAA FIRE ALARM ANNUNIATOR MTR MOTOR SEC SECONDARY AWG AMERICAN WIRE GAUGE FC FOOT CANDLES —N— NEUTRAL (GROUNDED CONDUCTOR) SNOPUD SNOHOMISH COUNTY PUD BAT BATTERY FLA FULL LOAD AMPERES INC NORMALLY CLOSED SPDT SINGLE POLE DOUBLE THROW BFG BELOW FINISHED GRADE FLEX FLEXIBLE NEC NATIONAL ELECTRICAL CODE SPST SINGLE POLE SINGLE THROW C CONDUIT (CIRCULAR RACEWAY) FTB FLUIDIZED THERMAL BACKFILL —,NEG NEGATIVE SURF SWBD SURFACE SWITCHBOARD CAB CABINET FU FUSE NEMA NATIONAL ELECTRICAL SWGR SWITCHGEAR CB CIRCUIT BREAKER GEN GENERATOR MANUFACTURE'S ASSOC. TB TERMINAL BOARD CFM CUBIC FEET PER MINUTE GFI GROUND FAULT CIRCUIT NIC NOT IN CONTRACT TC TIMECLOCK CKT CIRCUIT INTERRUPTER NL NIGHT LIGHT (UNSWITCHED) TEL TELEPHONE CLG CEILING GND GROUND NO NORMALLY OPEN TYP TYPICAL CO CONDUIT ONLY GRC GALVANIZED RIGID STEEL CONDUIT NTS NOT TO SCALE UL UNDERWRITERS LAB CONT. CONTINUATION GRID IN —GROUND OC ON CENTER UON UNLESS OTHERWISE NOTED CU COPPER HP HORSEPOWER OD OUTSIDE DIAMETER V VOLTS DC DIRECT CURRENT HZ HERTZ (CYCLES PER SECOND) OFCI OWNER FURNISHED CONTRACTOR VA VOLT—AMPERES DISC DISCONNECT IES ILLUMINATING ENGINEERING SOCIETY INSTALLED VFD VARIABLE FREQUENCY DRIVE DIA DIAMETER ID INSIDE DIAMETER OFOI OWNER FURNISHED, OWNER W WATT DIV DIVISION IG ISOLATED GROUND INSTALLED W/ WITH DP DISTRIBUTION PANEL IN INCANDESCENT OS OCCUPANCY SENSOR W/0 WITHOUT DPDT DOUBLE POLE DOUBLE THROW IMC INTERMEDIATE METAL CONDUIT P POLE WP WEATHERPROOF DPST DOUBLE POLE SINGLE THROW K KEY OPERATED PB PUSH—BUTTON XFMR TRANSFORMER DWG DRAWING KCM THOUSAND CIRCULAR MILS PEND PENDANT 11 IFT N INCHES EXIST EXISTING KO KNOCK OUT PH PHASE FEET EF EXHAUST FAN KW KILOWATTS PLP POWER/LIGHTING PEDESTAL PHASE KVA KILO VOLT—AMPERES n[p=(KM)nlo lomllm�H(m DIAGRAMS SYMBOL DESCRIPTION UTILITY XFMR - POLE MOUNTED TX KVA, VOLTAGE, PHASE "A-xxx" (UTILITY # IF APPLICABLE) J XFMR - (MOUNTING) KVA, VOLTAGE, PHASE 1 "A-xxx" (UTILITY # IF APPLICABLE) E-DM PF METER W/CURRENT TRANSFORMER M = UTILITY CO. APPROVED SOCKET WITH METER KW KVAR PF = POWER FACTOR METER KW/KVAR = COMBINATION KILOWATTHOUR/KVAR ECURRENT TRANSFORMER GF GROUND FAULT RELAY xxx/y CIRCUIT BREAKER xxx = AMPACITY, y = POLES ° SWITCH / xx d xxx = AMPACITY �xx DISCONNECT SWITCH xx = AMPACITY � DISCONNECT SWITCH - FUSED xx xx = AMPACITY O JUNCTION BOX (M) (P) MOTOR OR PUMP, AS NOTED ® SPECIAL RECEPTACLE 0 LIGHTING/POWER PEDESTAL LIGHTING CONTROLLER LTG. TC TC = TIMECLOCK CONTROLLED HOA = HAND -OFF -AUTO SWITCH CONTROLLED IRRIG IRRIGATION SYSTEM CONTROLLER SECUR SECURITY/CCTV SYSTEM CONTROLLER FA FIRE ALARM CONTROLLER ELR END OF LINE RESISTOR a-b-c UNDERGROUND VAULT (SEE DESCRIPTION UNDER SITE SYMBOLS) ELECTRICAL LEGEND* WIRING DIAGRAMS SYMBOL / DESCRIPTION OH 12.47KV OVERHEAD LINE P 12.47KV UNDERGROUND LINE CONDUIT OR RACEWAY — — — — — — — UNDERGROUND CONDUIT — — — — — — — CONDUIT LINE WEIGHT CONDUIT EXISTING LINE WIEGHT E CONDUIT RACEWAY STUB —OUT REFERENCE SYMBOLS SYMBOL DESCRIPTION X REFER TO DETAIL NO. ON DRAWING INDICATED NOT ALL EX.XX DETAIL REFERENCES ARE SHOWN. ALL DETAILS APPLY TO ALL APPLICABLE SITUATIONS, UON. X ELEVATION TAG: REFER TO NUMBER EX.XX AND SHEET INDICATED Ax SECTION TAG: REFER TO DETAIL NO. ON DRAWING. EX.XX NOT ALL DETAIL REFERENCES ARE SHOWN. ALL DETAILS APPLY. OX SHEET NOTE REFERENCE IMAGE/PHOTO REFERENCE. REFER TO ADJACENT OR X ASSOCIATED DETAILS FOR LOCATION P—HV 12.47KV H.V. CABLE CURRENT OR FUTURE. PROVIDE WIRE AND RACEWAY WHERE SHOWN 30.3 FEEDER TAG: NOMINAL AMPACITY & TYPE: SEE FEEDER SCHEDULE 2.0"C 30.3 CONDUIT IN SIZE SHOWN WITH FEEDER AS INDICTED 2.0"C M30.3 30.3 CONDUIT IN SIZE SHOWN WITH MULTIPLE FEEDERS AS INDICTED 2-2.0"C CONDUIT IN QUANTITY/SIZE SHOWN WITH MULTIPLE FEEDERS AS INDICTED. ROUTE CIRCUITS AS REQUIRED. REFER TO PLANS AND DETAILS FOR INFORMATION HE3 R12 8EL-1 FIXTURE TAG: FIXTURE TYPE PANEL —CIRCUIT R12 8EL-1 FIXTURE TAG: FIXTURE TYPE PANEL —CIRCUIT FH1 POLE TAG: AREA/POLE NUMBER A3-14 POLE TYPE 8EH-1 PANEL —CIRCUIT (NOTE: SEE 'UNDERGROUND PULL BOX/MANHOLE' FOR SYSTEM ABBREVIATIONS) LIGHTING - EXISTING SYMBOL DESCRIPTION POLE MOUNTED LUMINAIRE WITH FIXTURE ARM 0-0 LIGHT POLE WITH ARM AND FIXTURE LIGHT POLE 0 WITH TWO ARMS AND FIXTURES 0--- FLOODLIGHT FIXTURE, LIGHTING POLE WITH TOP/ ° CENTER MOUNTED FIXTURE LIGHTED BOLLARD SURFACE OR RECESSED FIXTURE (IE.. PROMENADE LIGHTING) SIGN LIGHTING FLOODLIGHT SITE ELECTRICAL EQUIPMENT - EXISTING SYMBOL I DESCRIPTION UTILITY POLE WITH ARM a—b—c UNDERGROUND PULL BOX/MANHOLE a = SYSTEM COM — COMMUNICATIONS D — DATA E — ELECTRICAL P — PUD HV POWER TEL — TELEPHONE CBL— CABLE TX — UTILITY TRANSFORMER VAULT FO — FIBER OPTIC b = PROJECT ZONE LOCATION c = NUMBER HANDHOLE — STREET LIGHTING, TREE LIGHTING AND BRANCH CIRCUIT SITE WIRING 0 I POWER PEDESTAL 11 POWER PANEL NOT ALL SYMBOLS LISTED ARE USED. LIGHTING SYMB`OL1 DESCRIPTION / 'T` POLE MOUNTED LUMINAIRE o LIGHTED BOLLARD WALL MOUNTED LUMINAIRE SIGN LIGHTING FLOODLIGHT ® CAST IN PLACE FIXTURE - LED Q CAST IN PLACE, LIGHTING FIXTURE, CAST IN PLACE, GRADE LIGHTING FIXTURE, ® CAST IN PLACE, PATH LIGHTING FIXTURE, © SURFACE MOUNTED LINEAR STRIP - LED CAST IN PLACE, STAIR LIGHT O LANDSCAPE WELL UP -LIGHT FIXTURE, SITE ELECTRICAL SYMBOL DESCRIPTION 4'x4'x3'D VAULT WITH STEEL LID C = COMMUNICATIONS E = ELECTRICAL/LIGHTING P = POWER: PUD POWER WSDOT TYPE 2 J-BOX; NONSLIP LID �i C = COMMUNICATIONS E = ELECTRICAL/LIGHTING ® WSDOT TYPE 1 J-BOX NON -SLIP LID PEDESTRIAN RATED FRONTIER-35 WITH DBL-STEEL LID T = TELEPHONE ❑ SW PUD PRIMARY SWITCH CABINET PV PUD PRIMARY PULL VAULT ITX l PUD PAD MOUNTED UTILITY TRANSFORMER (LESS THAT 750KVA, SHOWN ON DRAWINGS) NOTE: PROVIDE VAULT TYPE AS SHOWN ON DWGS. CLEAR ZONE/GUARD POST CENTERLINE SITE ELECTRICAL EQUIPMENT W/CLEAR ZONE SHOWN 0 ELECTRICAL EQUIPMENT AS NOTED OPUD ELECTRICAL METER ® GFCI RECEPTACLE WITH WEATHERPROOF WHILE -IN -USE COVER, ELECTRICAL EQUIPMENT CONDUIT RACEWAY - — — - UNDERGROUND CONDUIT - — — - CONDUIT LINE WEIGHT CONDUIT EXISTING LINE WIEGHT E- — — CONDUIT STUB OUT O CONDUIT STUB UP/DOWN R-406945 Nil m