HomeMy WebLinkAboutR-406710PERMIT#
eCURB INLET
C2.3
eBEEHIVE GRATE
C2.3
FG PER PLAN
TYPE 1 CURB INLET
W FREE BOARD
SEE BIORETENTION
HYDROSEED NOTE
BIORETENTION
SOIL MIX
NATIVE SUBGRADE, DO NOT
COMPACT NATIVE MATERIAL
UNDER BIO-RETENTION
AREA.
BERM
FG PER PLAN �II PER PLAN
8" OR 8" STREAMBED
COBBLES PER WSDOT
STD 9-03.11(2)
(2.0'MIR) FIE PER PLAN
\A j
3' C
DEPTH
18" IN.
O 8
j0 r, 8" MIN.
LAYER OF FILTER C Tea®
FABRIC, ALL SIDES. T PERFORATED PVC
MIRAFI 140N OR EQUAL UNDER -DRAIN PIPE @ 0.0%.
IE: PER PLAN
BIORETENTION SOIL MIX
OUTLET
PER PLAN
1-1/2"-3W NON
FRACTURED DRAIN ROCK
EQUIV. TO WSDOT SPEC.
9-03.12(5)
BIORETENTION SOIL MIX (BSM) SHALL BE A WELL -BLENDED HOMOGENEOUS MIXTURE OF 60 TO %PERCENT BY VOLUME MINERAL
AGGREGATE FOR BIORETENTION SOIL AND 35 TO 40 PERCENT BY VOLUME COMPOST AS DETAILED IN THE TABLES BELOW.
MINERAL AGGREGATE FOR SIORETENTION SOIL
TABLE: MINERAL AGGREGATE GRADATION
&EVE ORE
PERCENT PASSING
Ne INCH
IN PERCENT
U.S. NO
%TO IN PERCENT
U.S. N0, 10
75 TO BD PERCENT
us NO.4D
25 TO 4D PERCENT
ULS. NO. IN
4TO 10 PERCENT
US. NO. NO
2TO4 PERCENT
MINERAL AGGREGATE FOR BIORETENTION SOIL MUST BE FREE OF W000,
WASTE, COATING. OR ANY OTHER DELETERIOUS MATERIAL. AND ALL
AGGREGATE PASSING THE NO. NO SIEVE SIZE MUST BE NON -PLASTIC.
MINERAL AGGREGATE MUST BE ANALYZED BY AN ACCREDITED LAB USING
THE SIEVE SIZES NOTED IN THE TABLE TO THE LEFT. AND MUST MEET THE
REQUIRED GRADATIONS.
COMPOST
TABLE: COMPOST GRADATION
SIEVE SIZE
MIN. PERCENT PASSING
2-INCH
IN PERCENT
I -INCH
SS PERCENT
51&INCH
SO PERCENT
114-INCH
75 PERCENT
COMPOST MUST ORIGINATE A MINIMUM 65 PERCENT BY VOLUME FROM
RECYCLED PLANT WASTE COMPRISED OF YARD DEBRIS, CROP RESIDUES.
AND BULKING AGENTS. AND MEET THE DEFINITION OF 'COMPOSTED
MATERIAL' IN WAG 173,350-100. COMPOST SHALL HAVE A MOISTURE CONTENT
THAT HAS NO VISIBLE FREE WATER OR MST PRODUCED WHEN HANOUNG
THE MATERIAL COMPOST SHALL HAVE AN ORGANIC MATTER CONTENT OF 40
PERCENT TO 65 PERCENT BY DRY WEIGHT, A CARBON TO NITROGEN RATIO
BELOW 25:1. AND A pH BETWEEN 6.0 AND 8.0
ABORIST WOOD CHIP MULCH
TABLE: ARSONIST WOOD CHIP MULCH GRADATION
SIEVE 612E
PERCENT PASSING
6 INCH
1DOPERCENT
24WN H
TO IN PERCENT
1-INCH
70 TO 100 PERCENT
516-INCH
0TO 50 PERCENT
U.S. NO
0 TO M PERCENT
AR SORIST WOOD CHIP MULCH SHALL BE COARSE GROUND WOOD
CHIPS (APPROXIMATELY V2" TO 6" ALONG THE LONGEST DIMENSION)
DERIVED FROM TIE MECHANICAL GRINDING OR SHREDDING OF THE
ABOVE-GROUNO PORTIONS OF TREES. IT MAY CONTAIN WOOD. WOOD
FIBER. SANK. BRANCHES. AND LEAVES. BUT MAY NOT CONTAIN
WEEDS, WEED SEEDS, OR VISIBLE AMOUNTS OF SOIL
PLANS
BIORETENTION HYDROSEED NOTES
FORREFER
BUFFER PUNTING
FOR BUFFER PLANTING AND
TOPSOIL REQUIREMENTS
UNLESS OTHERWISE STATED ON APPROVED PLANS, THE REQUIRED METHOD OF SEEDING SHALL BE BY AN
APPROVED HYDROSEEDER WHICH UTILIZES WATER AS THE CARRYING AGENT, AND MAINTAINS CONTINUOUS
AGITATION THROUGH PADDLE BLADES. IT SHALL HAVE AN OPERATING CAPACITY SUFFICIENT TO AGITATE, SUSPEND,
AND MIX INTO A HOMOGENEOUS SLURRY THE SPECIFIED AMOUNT OF SEED, WATER, FERTILIZER AND MULCH.
GRASS SEED
ALL SHALLNEW OONP SEED. SEED IS TO BE MIXEDMECHANICALLY
ES
EALLER.IIN IF SEEED IS M XEDN,
THE SIT EACHVAR ETV SHALL BE DELIVERED IN THE
ORIMAY BE MIXED
-S IT
CRIGINAL CONTAINERS
LAANALYSIS.LERS GUARANTEED
ONTRACTOR SHALLE FURNIS
H TO THE NDSCAPE ARCHITECTT DE CALERIS GUARANTEED STATEMENT OF THE
COMPOSITION OF THE MIXTURE AND THE PERCENTAGE OF PURITY AND GERMINATION OF EACH VARIETY.
�\
GRASS SEED SHALL BE PURCHASED FROM A RECOGNIZED DISTRIBUTOR AND SHALL BE COMPOSED OF THE
FOLLOWING VARIETIES MIXED IN THE PROPORTIONS INDICATED. SEED SHALL MEET THE MINIMUM PERCENTAGES OF
PURITY AND GERMINATION SPECIFIED. SEED SHALL BE APPLIED AT THE RATE OF 240 POUNDS PER ACRE, UNLESS
OTHERWISE SPECIFIED BELOW ON THE APPROVED PROJECT PLANS.
WATER
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING A WELL -ESTABLISHED STAND OF GRASS THAT IS ACCEPTABLE
TO THE OWNER FOR THE PURPOSE INTENDED. WATERING IS SUGGESTED AT LEAST TWICE A WEEK DURING THE
GROWING SEASON AND AS NEEDED AFTERWARDS.
WHEN GRASS IS REQUIRED AS A BEST MANAGEMENT PRACTICE ON STEEP SLOPES, NON -GERMINATED SEEDS SHALL
BE KEPT MOIST, AND ROOTED GRASS SHALL HAVE AT LEAST 1 INCH OF WATER PER MONTH DURING THE PERIOD
FROM MAY 15 THROUGH SEPTEMBER 15.
FERTILIZER
UNDERDRAIN PERFORATION NOTES:
FERTILIZER SHALL BE A COMMERCIAL MIX WITH A 16-14-8 FORMULA, INCLUDING 50 PERCENT SLOW RELEASE
SLOTS SHOULD BE CUT PERPENDICULAR TO
NITROGEN, OR THAT MIX AS RECOMMENDED BY THE SEED SUPPLIER AND APPROVED FOR USE BY THE LANDSCAPE
THE LONG AXIS OF THE PIPE AND BE 0.04-0.069
ARCHITECT.
INCH BY 1 INCH LONG AND BE SPACED 0.25 INCH
APART (SPACED LONGITUDINALLY). SLOTS
MULCH
SHOULD BE ARRANGED IN TWO ROWS SPACED
WOOD OR RECYCLED NEWSPAPER CELLULOSE FIBER MULCH SHALL BE APPLIED AT THE RATE OF 2,000 POUNDS TO
ON 45-DEGREE CENTERS AND COVER
THE ACRE. MULCH SHALL BE INCORPORATED INTO THE SLURRY OF WATER, SEED, AND FERTILIZER AND SHALL
CIRCUMFERENCE OF THE PIPE. SLOTTED
SUBSURACE DRAIN PVC PER ASTM D1785
CONTAIN A COLORING AGENT TO FACILITATE A VISUAL INSPECTION OF COVERAGE DURING AND AFTER APPLICATION.
SCHI
GRASS MIXES USED SHALL MEET THE FOLLOWING SPECIFICATIONS: %BY WEIGHT
CATCH BASIN NOTES:
(BIOFILTRATION SOURCE GRASS): APPLICATION (RATES PER ACRE):
1. TYPE 1 P CATCH BASIN PER WSDOT
10% CREEPING FESCUE NOW WOODFIBER MULCH
STANDARD PLAN B5.60-02.
45% INTERMEDIATE WHEATGRASS (REGREEN) 80N SEED MIX
5% PERENNIAL RYEGRASS 30DN 25-0-14 FERTILIZER W/ SULFUR COATED UREA
30%TALL FESCUE 30G ERO-BOND
NOTES:
1. AVOID COMPACTION OF EXISTING SUBGRADE BELOW BASIN,
2, SCARIFY SUBGRADE TO A DEPTH OF 31NCHES MINIMUM IMMEDIATELY PRIOR TO PLACEMENT OF BIORETENTION SOIL MIX AND UNDERDRAIN AGGREGATE,
EXCEPT WHEN LINER IS REWIRED.
3. LINER TO BE INSTALLED ONLY WHEN REQUIRED IN THE CITY OF RENTON SURFACE WATER DESIGN MANUAL(RENTON SWDM). LOW PERMEABILITY LINER TO
BE 30 MIL MIN. GEOMEMBRANE LINER OR 12INCHES MIN. (DRY) CLAY LINER. CLAY LINER TO BE COMPACTED TO %% MINIMUM DRY ENSITY (ASTM Meet.
WITH AT LEAST 30%CLAY PARTICLES PASSING (ASTM 0,122) AND AT LEAST 15% PLASTICITY INDEX (ASTM 04318).
4. UNDERDRAIN TO M V MIN. (PRIVATE). W MIN (PUBLIC SLOTTED PVC PER ASTM 01 T85 SCH 40. SLOTS SHOULD BE CUT PERPENDICULAR TO THE LONG AXIS
OF THE PIPE AND BE ON TO0 See INCHES BY 1 INCH LONG AND BE SPACED 0 25INCHES APART (SPACED LONGITUDINALLY) SLOTS SHOULD BE ARRANGED
IN FOUR ROWS SPACED ON 4SDEGREE CENTERS AND COVER In OF THE CIRCUMFERENCE OF THE PIPE. SLOPE PIPE AT 0.5% MIN UNLESS OTHERWISE
SPECIFIED. PROVIDE ONE CLEANOUT MIN. PER IOD FEET OF UNDERDRAIN, AND AT EACH END. SEE STD. PLAN 226.N MATCH CROWN ELEVATION OF
UNDERDRAIN TO OVERFLOW PIPE UNLESS OTHERWISE SPECIFIED.
5. Is -MIN. BIORETENTION SOIL MIX ON BOTTOM AND SIDES TO TOP OF BONDING AREA. BIORETENTION SOIL MIX TO MEET STD. PLAN 262,W
6. UNDERDRAIN AGGREGATE TO MEET STD. PLAN 282 A.
2 ARBORIST WOOD CHIP MULCH TO MEET STD. PLAN 262S0_
B. MAXIMUM LONGITUDINAL SLOPE (ALONG DIRECTION OF FLOW) OF BIORETENTION SWALES SHALL BE 6%.
9, WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED N SHJRETENTHJN. REDUCE BOTTOM MOM TO 6 INCHES
MINIMUM AND INCREASE SIE SLOPE TO 1,WIV ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES.
GENERAL NOTES:
I. MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS, STD. PLANS 26500. 265.10, AND 26520. AND
OTHER UTILITY PROVIDER REQUIREMENTS. COORDINATE WITH CITY ENGINEER IN THE EVENT OF UTILITY CROSSINGS OR CONFLICTS.
2. BSM PLACEMENT. GRADING, AND CONSOLIDATION SHALL NOT OCCUR WHEN THE BSM IS EXCESSIVELY WET OR HAS BEEN SUBJECTED TO MORE THAN
117 OF PRECIPITATION WITHIN 48 HOURS PRIOR TO PLACEMENT. EXCESSIVELY WET IS DEFINED AS BEING AT OR ABOVE U%SOIL MOISTURE BY A
GENERAL TOOLS AND INSTRUMENTS DSMMSOO PRECISION DIGITAL SOIL MOISTURE METER WITH FROM (OR EWNALENT). THERE SHOULD M NO
VISIBLE FREE WATER IN THE MATERIAL. THE CONTRACTOR SHALL PLACE BSM LOOSELY WITH A CONVEYOR BELT OR WITH AN EXCAVATOR OR LOADER
FROM A HEIGHT NO HIGHER THAN 6 FEET. UNLESS OTHERWISE APPROVED BY THE ENGINEER (I E.. DO NOT DUMP MATERIAL DIRECTLY FROM TRUCK
INTO CELL) COMPACT BBM USING NON -MECHANICAL COMPACTION METHODS (E G BOOT PACKING. HAND TAMPING, OR WATER CONSOLIDATION) TO
83%ix 2%)OF THE MAXIMUM DRY DENSITY PER MODIFIED PROCTOR TEST (ASTM D1557). OR AS DIRECTED BY THE ENGINEER.
3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
UNDERDRAIN AGGREGATE STD. PLAN-262.t
DEPARTMENT
PUBLIC WORKS ' PueucWORKS BIORETENTION SECTION
0 DEPARTMENT BIORETENTION SOIL MIX, AND MULCH GqZ 9/z8/(WITH UNDERDRAIN)
SPECIFICATIONS
BIORETENTION SWALE
0
Know what's below.
CaII before you
�9U HE M_TED INPART. NOT RESPONSIBLE
WHILE THIS FORIT ACCURACY
INFORMATION'S
EVETO ML
BE RELIABLE PICH IS NOT RESPONSIBLE FOR ITS ACCURACY, OR ERROR OR
OMISSIONS WWCH MAY RELYING
ON
RECORDDOCUMENT
INCORPORATED ENTWO TXIS DOCUMENTADVISED
TO S
A RESULT. :HOSE RELYING ON THIS RECORD OOLVMENi PREAOVIBED TO Pu11H ML
OBTAIN INDEPENDENT VERIFICATION OF RBALCURALV BEFOREAFPLYING IT
FORANYPORPOFF S-K
N0. REVISION BY DATE APPR AAA BE"EC01°"¢'
UNLESSOTHERWBENOTED,DRAWINGISNCI XaLM
STD. PLAN - 262.10
GAZ 9/28/2018 I
v.1k, w'.. „o. DATE
I'°�AL: HAS 1°w'"' � CITY OF
4 RENTON
DATUM
Planning/Building/Public Works Dept.
/ �!G/ASC✓ TACO MA S EATTL E
S PO KAN E TRI-CITIES
M'Y910NAt �M1 2215 North 30th Street, Suite 300 Tacoma, WA 98403
OF//y/zDZJ 253.383.2422 TEL 253.383.2572 Em mANGL hhl.mm WEB
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WALKER MAZDA DEALERSHIP 7/29/2019
AS-BUILTS
AHBL JOB #2180100.11
BIORETENTION CROSS-SECTION AND NOTES C2.4
r�
O
N
N
O
O
O
T
L]
OF)
O
co
O
O
O
00
Q
J
N
N
O
O
O
DO
T
To
7
R-406710