HomeMy WebLinkAboutR-406717I
PERMIT#
Z it y 4 D
O
0 GRAPHICSCALE I) 2
LU 0 I) a $ 15
I— UVI
1"=30FEET — —P
J11 S=R
_----G--r--G-- GAG---_
0+06 STA'0+17'42 REMOVE EXISTING — G—
BEGIN FRONTAGE IMPR EMENTS 1+00 SIDEWALK 2.
SAWCUT LIMITS
-----==JN—t-=(TP)W—_— _W—
OVERHEAD POWER - USE CAUTION
EXISTING OVERHEAD POWER IS
HIGH VOLTAGE TRANSMISSION LINE
RELOCATE VAULT OUTSIDE OF
SIDEWALK
FM
III G---__G-----G --/
EAST VIRO4
nn PROTECT EXIST— + I--
'll CURB AND GUTTER
—W---- ----f
END FRONTAGE IMPROVEMENTS
-P P
❑ �S—_--_ — / F—--D
4+00
PROTECT STORM DRAIN r1 ---W—_—_
PROTECT STORM DRAIN
RELOCATE HYDRANT I -- —
--------_—_— --
��
---- _— 4P
I
� _---
----------QP
1JP
TO PLANTER STRIP ) I RELOCATE SIGN
RELOCATE GAS
— _ — _�
PROTECT
I I TO PLANTER STRIP
OUTSIDE OF SIDEWALK
----_--- I
I
RELOCATE FIRE HYDRANT
TRANSMISSION POLE
I
TO PLANTER STRIPS
I I I F-----__--
—_--_— �C--- 4
`
N✓/
�`j ®Q I
FUTURE PAVING
))
F J FUTURE SIDEWALK
\�X
�
PROTECT LIMITS I )
)
I I LIMITS
�
TRANSMISSION POLE li
I
1
REMOVE WATER METER AND
I
DEMOLITION PLAN
SERVICE LINE. REMOVAL TO BE
PREFORMED BY CITY FORCES
z
I— — f — D STA:3+23.43,
) I+ a
GRAPHIC SCALE �) £ 3 STA:3+21.31, 23.25'
1 VRT
/
0 15 30 60 I h
— — STA:3+13.51.24.3 RT \_ —p � y STA:3+11.21, 25.11
R5.11'RT
/ D R21
1" - 30 FEET / /�
O ��, STA:3+04,19, 26,35'RT
S��5'g�yg _
_ � - — ��{
PROVIDE PAVEMENT PATCH T a E "
PER CITYOF RENTON STD. PLAN 110 III
("l—D— — —p--i— —
_--:
STA:O+17 42 ~ _ G c 1 G — — —
O+Od PROVIDE FLUSH 2
BEGIN FRONTAGE IMPROVEMENTS 1+00 `
�___;_ CURB AND GUTTER C5.2 +00
3 PROVIDE CURB —�--
5.2 RAMP PROVIDE CURB RAMP Ci2
— -- ——W-----
PROTECT
TRANSMISSION POLE
RELOCATE HYDRANT ELOCATE—SIT
TO PLANTER STRIP I TO PLANTER STRIP I
I I RAISE VAULT TO
I I FINISHED GRADE
I I
I I
PROVIDE CONCRETE 2
PROPOSED PARKING AREA DRIVEWAY C5.3 / \ OF SIDEWARELOCATE GKSOUTSIDE
IMPROVEMENTS PLAN
RELOCATE VAULT OUTSIDE
OF SIDEWALK
—W--)K--W_—_
R25' PROVIDE STREET LIGHTS PER PLAN. SEE SHEETS
STA:3+31.19, 24.33'RT IL-01, 02, 03, AND PC-01 FOR MORE INFORMATION
$TA:3+33.fi3. 25.13'RT
R25'
STA:3+41.38, 26.36'RT
RELOCATE HYDRANT
TO PLANTER STRIP STA:4+75.47
END FRONTAGE IMPROVEMENTS
PROVIDE PAVEMENT PATCH
PER CITY OF RENTON STD. PLAN 110
----P-----P—
Know what's below.
Call before you
9 25'
DEMOLITION NOTES
1. CONTRACTOR IS TO VERIFY LOCATION AND DEPTH OF ALL UTILITIES SHOWN.
THE CONTRACTOR IS TO PROTECT UNDERGROUND UTILITIES DURING
CONSTRUCTION.
2. CONTRACTOR TO PROTECT EXISTING STORM SYSTEM LOCATED IN FRONTAGE
ALONG EAST VALLEY ROAD.
3. CONTRACTOR TO PROTECT EXISTING CURB AND GUTTER LOCATED IN
FRONTAGE ALONG EAST VALLEY ROAD.
DEMOLITION LEGEND
PROPERTY BOUNDARY
ROAD CENTERLINE
—
RIGHT OF WAY BOUNDARY
— — — —
FUTURE ONSITE IMPROVEMENTS
-------
SIDEWALK
EXISTING TREE
EXISTING POWER
— — P — —
EXISTING UTILITY POWER POLE
o
EXISTING GAS LINE
— — G —
EXISTING COMMUNICATION LINE
— — T — —
EXISTING WATER LINE
-
EXISTING SEWER LINE
FRONTAGE IMPROVEMENT NOTES
1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS
DEPARTMENT AND THE LATEST EDITION OF THE WSDOT STANDARDS AND
SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN
THE RENTON STANDARD PLANS AND SPECIFICATIONS.
2. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE. THE
CONTRACTOR IS RESPONSIBLE TO VERIFY THE LOCATION AND DEPTH OF ALL
UTILITIES SHOWN.
3. CONTRACTOR IS TO RAISE ALL REMAINING STRUCTURE LIDS TO BE FLUSH
WITH FINISHED GRADE. REFER TO PLAN FOR REMAINING STRUCTURES.
4. ALL IMPROVEMENTS WITHIN THE PUBLIC RIGHT OF WAY SHALL CONFORM TO
CITY OF RENTON CONSTRUCTION STANDARDS.
EAS VALLEI�ROA G — — °— 4+00 FRONTAGE IMPROVEMENT LEGEND
5+00
/ 2 1 PROVIDEFLUSH — -- PROPERTY BOUNDARY _
05.2 CBAND GUTTER
ROAD CENTERLINE
CR.. RIGHT OF WAY BOUNDARY — — — —
_ t4
_ -3 ti 5' ASPHALT PAVING
ePROVIDE I�f PROPOSED SIDEWALK
C5.3 CONCRETE
DRIVEWAY EXISTING SIDEWALK
PROVIDE I EXISTINGTREE
61311 EWALK I
/ I EXISTING GAS LINE—
�-----
1 EXISTING COMMUNITCATION LINE .(
PROVIDE 325'SIDEWALK WIDENING EXISTING WATER LINE
PROTECT TRANSMISSION POLE
EXISTING SEWER LINE --S--
T A C O M A - S E A T T L E
EXISTING OVERHEAD POWER — — OP -- A
�Sr�RN® ,�B S P O K A N E - T R I- C I T I E S
ss2oxA1. �1G1 2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422 TEL 253.383.2572 FM w Lahbl.mm WEB
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
.1116wmw11 16 ,�, ,�
ME�NIMIaIM
DATUM
SUBMITTED, IN PART, BY OTHERS. WHILE THIS INFORMATION IS BEOLIEVED TO
BE RELIABLE. AHBL IS NOT RESPONSIBLE FOR ITS ACCURACY, OR ERROR OR
OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THIS DOCUMENT PS
A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT PRE ADVISED TO
OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT
FORANV PVRPOBE
BF ML
DMI
ML
LH:��Bt S-K
��
U"EC01OMXY
N0.
REVISION
BY
DATE
APPR
Mwa•R
CITY OF
' PENTON
Planning/Building/Public Works Dept.
WALKER MAZDA DEALERSHIP 7/29/2019
AS-BUILTS INI
MINE
AHBL JOB #2180100.11 B 11`k
PUBLIC FRONTAGE IMPROVEMENT PLAN MC5.1
RE27 ff.
R-406717
O
N
N
O
O
T
A
L1!
L]
co
O
O
O
00
Q
J
N
N
O
O
O
00
T
To
al