Loading...
HomeMy WebLinkAboutL320-DL-11LC_ A Elevation8'-0" HDR. HGT. TYP.9'-118"9'-118"T.O.C. F.F. T.O.P. T.O.P.8'-0" HDR. HGT. TYP.T.O.P.12'-118"2'-412"6 D1 2 D3 2B D6 12 D6 BRICK VENEER 2x6 WOOD TRIM STONE CAP TRIM PANEL 7 D5 1 D6 6 D6 11 D6 2" METAL MITER CAPS AT 4" HORIZONTAL REVEAL- TYP. HORIZONTAL SIDING 4" REVEAL 2x4 CORNER BOARD-TYP. HORIZONTAL SIDING 8" REVEAL FLAT METAL FLASHING/CAP 14":1'-0" SLOPE A - 13 D1 BRICK VENEER 2x2 8" LAP SIDING "A" WINDOW AREA TABULATIONS AREA OF TOTAL FACADE 897 S.F. AREA OF WINDOWS 366 S.F. WINDOW PERCENTAGE 41% *INCLUDES GLASS GARAGE DOOR ±25'-7"7 D5 SIM. 8 D5 9'-118"9'-118"F.F. F.F. T.O.P. T.O.P.9'-118"T.O.S. T.O.P.8'-0" HDR. HGT. TYP.8'-0" HDR. HGT. TYP.8'-0" HDR. HGT. TYP.1 D6 6 D6 11 D6 3 D3 2x4 CORNER BOARD-TYP. HORIZONTAL SIDING 8" REVEAL 2x4 WOOD TRIM 2x4 WOOD TRIM HORIZONTAL SIDING 4" REVEAL 2" METAL MITER CAPS AT 4" HORIZONTAL REVEAL- TYP. 12 D6 14 D1 FLAT METAL FLASHING/CAP 14":1'-0" SLOPE 12 D5 13 D1 6x6 WOOD- WRAP POST 8.1 D3 2x8 WOOD TRIM WINDOW AREA TABULATIONS AREA OF TOTAL FACADE 1279 S.F. AREA OF WINDOWS 475 S.F. WINDOW PERCENTAGE 37%±35'-9"RIDGE 4:12 4:12 RIDGE4:124:124:12VALLEY VALLEYHIPHIPHIPHIPHIPHIPHIPHIPHIPH I P HIPH I PHIPH I PHIPHIPVALLEY VALLEYVALLEYVALLEY4:12 4:12 4:12 4:12 4:12VALLEY4:124:124:124:124:12RIDGERIDGERIDGER.4:124:12HIP3:12 3:121/4" SLOPE5'-6"DS DS DS DS 28'-0"AREA 1 1'-6" TYP. EAVE AREA 2 R.12 D1 7'-0"DS REFERENCE SLAB PLANS FOR DS LOCATION - SLOPE TO DRAIN Ø Ø ©1.THE CONTRACTOR RESPONSIBLE FOR FABRICATION & INSTALLATION OF GUTTERS & DOWNSPOUTS SHALL SUBMIT SHOP DRAWINGS CONSISTING OF ROOF PLANS, ELEVATIONS & DETAILS OUTLINING THE ENTIRE GUTTER & DOWNSPOUT SYSTEM TO THE BUILDER/CONTRACTOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 2.DOWNSPOUTS SHALL BE TIED INTO AREA DRAINS, SEE PRECISE GRADING PLAN. 3.ALL DOWNSPOUTS SHALL BE HIDDEN TO THE BEST EXTENT POSSIBLE. 4.THE TRUSS MANUFACTURER SHALL ALLOW FOR SERVICE ACCESS TO THE ATTIC MOUNTED FORCED AIR UNITS, (WHERE APPLICABLE) 5.THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/300 OF THE VENTED SPACE PROVIDED ONE OR MORE OF THE FOLLOWING CONDITIONS ARE MET: 1.IN CLIMATE ZONES 6, 7 AND 8, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING 2.AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR THE HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. R806.2 2012 INTERNATIONAL RESIDENTIAL CODE ROOF PLAN NOTES 1.SEE SHEET A1 FOR ALL GENERAL NOTES AND REQUIREMENTS. 2.SEE SHEET A1 FOR TYPICAL BUILDING MATERIALS. 3.PROVIDE DOUBLE UNDERLAYMENT FOR ROOF PITCH FROM 2:12 UP TO (BUT NOT INCLUDING) 4:12. 4.TRUSS DESIGN BY MANUFACTURER. TRUSS PLAN AND FLOOR FRAMING DESIGN BY MANUFACTURER. FRAMING PLANS SHOWN ARE FOR GENERAL LAYOUT ONLY (SEE SHEET A1: SUMMARY 7) - TRUSS LOADING (SEE SHEET A1: SUMMARY 3-2) - TRUSS SPAN PER FLOOR FRAMING PLANS - TRUSS TYPE PER ROOF FRAMING PLAN 5.ROOF FRAMING SPACING, 24" O.C. U.O.N. 6.ROOF PITCH - EXTERIOR PER ELEVATION - INTERIOR PER SECTION. 7.ALL EXTERIOR WALLS ARE P1-6 TYPICAL U.O.N. 8.ROOF TAIL AND RAKE OVERHANG PER ROOF PLAN. 9.SEE 'S' SHEETS FOR SHEARWALL SCHEDULE, NOTES AND LATERAL DETAILS. 10.PLANS TO GOVERN FURNACE LOCATION. GENERAL FRAMING NOTES FRONT ELEVATION "A" 1/4" = 1/-0"NORTHWEST CONTEMPORARY REAR ELEVATION "A" 1/4" = 1/-0"NORTHWEST CONTEMPORARY ROOF PLAN "A" 1/8" = 1/-0" T.O.S. F.F. T.O.P. T.O.P.9'-118"9'-118"8'-0" HDR. HGT. TYP.8'-0" HDR. HGT. TYP.T.O.P. T.O.S.9'-118"9'-118"9'-118"F.F. T.O.P. T.O.P. F.F. 6'-10"1 D6 6 D6 11 D6 3 D3 12 D6 STONE CAP TRIM PANEL BRICK VENEER HORIZONTAL SIDING 8" REVEAL 2x4 WOOD TRIM 2x4 CORNER BOARD-TYP. HORIZONTAL SIDING 4" REVEAL 2" METAL MITER CAPS AT 4" HORIZONTAL REVEAL- TYP. 2x4 WOOD TRIM 12 D6 TRIM PANEL WINDOW AREA TABULATIONS AREA OF TOTAL FACADE 1251 S.F. AREA OF WINDOWS 98 S.F. WINDOW PERCENTAGE 8% 2x4 WOOD TRIM T.O.C. T.O.P. F.F. T.O.P. T.O.P. F.F.9'-118"9'-118"8'-0" HDR. HGT. TYP.9'-118"8'-0" HDR. HGT. TYP.1 D6 6 D6 11 D6 3 D3 14 D1 2" METAL MITER CAPS AT 4" HORIZONTAL REVEAL- TYP. 2B D6 12 D5 WINDOW AREA TABULATIONS AREA OF TOTAL FACADE 1222 S.F. AREA OF WINDOWS 236 S.F. WINDOW PERCENTAGE 19% TRIM PANEL 2x2 WOOD TRIM HORIZONTAL SIDING 8" REVEAL 6x6 WOOD- WRAP POST 8.1 D3 2" METAL MITER CAPS AT 4" HORIZONTAL REVEAL- TYP. HORIZONTAL SIDING 4" REVEAL 2x4 WOOD TRIM TRIM PANEL 13 D1 2x4 CORNER BOARD-TYP. 2x4 WOOD TRIM FLAT METAL FLASHING/CAP 14":1'-0" SLOPE 2x4 WOOD TRIM ©LEFT ELEVATION "A" 1/4" = 1/-0"NORTHWEST CONTEMPORARY RIGHT ELEVATION "A" 1/4" = 1/-0"NORTHWEST CONTEMPORARY