HomeMy WebLinkAboutR_401318CM
V—
O
i
O
i
w
75
Q
CO
CD
u;
0
z
0
1=
0
ca
J
MATCHLINE, SEE SHEET C81 R
4), Ber erABAM
CALL 48 HOURS �
BEFORE YOU DIG 33301 9th Avenue South, suite 300 REMOVAL
Federal Way, Washington 98003-2600
1-800-424-5555 (206) 431-2300 Fax: (206) 431-2250
SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE
- APRON R INFRASTRUCTURE W4700331 ABAM SPT 06/08/18
A CITY OF RENTON COMMENTS W4700331 ABAM SPT 10/01/18
P.
of WA �f
x
31271 w�
��ssioNaL
20 1 20 ' ///�..
scale %.. %ii ,
ACCEPTABILITY IJDM
THIS DESIGN AND/OR CHE(
SPECIFICATION IS APPROVED SPT
ENGI
APPROVED BY DEPT. DATE BEE
Al L SUBTITLE
06/08/18
06/08/18
06/08/18 TITLE
I P-(`P-NIn
ABANDON UNDERGROUND UTILITY
REMOVE UNDERGROUND UTILITY
r — REMOVE ALL ABOVE GROUND AND
BURIED UTILITIES ABOVE AND ADJACENT
TO PILE SUPPORTED STRUCTURE
EXISTING PILES
0 0 0 0
GENERAL NOTES
r-0 01 r-0-01
EXISTING PILE CAPS
LO — 0J L0 — 01
0 0 o
EXISTING BULKHEAD
0 0 o STRUCTURE
— — — — — PROJECT LIMITS
1. ALL UTILITIES IDENTIFIED TO BE ABANDONED WITH A DIAMETER 8" OR LARGER, SHALL BE FILLED WITH
CDF. SEE NOTES ON SHEET G02.
2. REMOVE EXISTING ALL CONCRETE PAVEMENT WITHIN PROJECT LIMITS AS APPLICABLE. PAVEMENT
REMOVAL SHALL BE TO NEAREST PANEL JOINT AT BOUNDARIES, SAWCUT AS NECESSARY. SEE SHEET
G08 FOR OVERALL EXISTING PAVEMENT THICKNESS PLAN.
3. SEE LANDSCAPE PLANS FOR LIMITS OF INVASIVE SPECIES REMOVAL AND LIMITS OF PLANTING AND
IRRIGATION REMOVAL/REPLACEMENT.
4. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICA DATUM
1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM
CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60
FEET.
5. THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS, COATINGS OR ZINC APPLIED SURFACE
TREATMENTS ON ANY EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ALL GALVANIZED OR
ZINC APPLIED MATERIALS OR COATINGS SHALL BE PERMANENTLY PAINTED OR COATED TO PREVENT
EXPOSURE OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR COMPLETION OF
CONSTRUCTION.
6. REFER TO CHANNELIZATION PLANS FOR SIGN REMOVAL AND RELOCATION.
SEE STRUCTURAL PLANS FOR PHASED PILE SUPPORTED STRUCTURE REMOVAL. PROVIDE AND
PROTECT SHORING FOR EXISTING STRUCTURES TO REMAIN AS SHOWN ON STRUCTURAL PLANS. SEE
SUBGRADE IMPROVEMENT PLANS FOR PROPOSED DEPTHS OF EXCAVATION. REMOVE ALL ABOVE
GRADE AND BURIED UTILITIES ON AND ADJACENT TO PILE SUPPORTED STRUCTURE.
SEE SECTIONS ON SHEET C500-5A FOR ADDITIONAL UTILITY REMOVAL DETAILS. FOR ESTIMATION
PURPOSES, UTILITY CONDUIT/PIPE TO BE REMOVED IN THE PILE SUPPORTED STRUCTURE AREA IS
KNOWN TO INCLUDE:
• f 75 LF ABOVE GROUND INSULATED WATER
• f 43 LF ABOVE GROUND DATA/COM
• f 377 LF BURIED POWER
• f 77 LF BURIED COMPRESSED AIR
• t 70 LF BURIED 3" WATER
• f 258 LF BURIED 1" WATER
• t 162 LF BURIED DATA/COM
CONSTRUCTION NOTES
REMOVE EXISTING SURFACE MOUNTED
WOOD BULLRAIL - 78 LF
2� REMOVE EXISTING HARDSTAND
3� REMOVE EXISTING UTILITY STAND
4� REMOVE EXISTING COMM J-BOX
RELOCATE DISASTER SUPPLY CONNEX.
COORDINATE WITH BOEING FOR LOCATION
AND REQUIREMENTS
ABANDON UNDERGROUND UTILITY
INSTALL BLIND FLANGE AT TEE.
CONTRACTOR TO NOTIFY BOEING FIRE A
MINIMUM OF 48 HOURS IN ADVANCE
REMOVE EXISTING ASPHALT OVER
CONCRETE PAVEMENT
9 REMOVE EXISTING CONCRETE CURB
- 26 LF
10 DECOMMISSION EXISTING MONITORING WELL
IN ACCORDANCE WITH WAC 173-160-460
- 2 EA
CIVIL PERMIT,
CIVIL SITE REMOVAL PLAN
r_�,Salle] 1■son IIIato= 1:0011111to] : I
RENTON SITE
11 REMOVE EXISTING BOLLARD - 4 EA
12 REMOVE EXISTING AIR VAULT - 2 EA
13 REMOVE EXISTING ELECTRICAL MANHOLE
-2EA
14 REMOVE EXISTING GROUND ROD AND WIRE
- 3 EA
15 REMOVE EXISTING WATER VAULT - 2 EA
16 REMOVE EXISTING UNDERGROUND UTILITY
17 PROTECT EXISTING VALVE AND ADJUST TO
GRADE
18 REMOVE EXISTING SIGN, SEE GENERAL
NOTE 6
19 REMOVE EXISTING CONCRETE PAVEMENT,
SEE GENERAL NOTE 2
KEY PLAN
SCALE: N.T.S.
R-401318
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
afowler 12/20/2018 +
W4700331 J" "' A ""' ` 10/01 / 18
C80 R C01
JOB NO. COMP NO.
W4700331
DWG N0.
RENTON, WA 4—APRON—R—C80R
CIVIL MASTER
SITE