Loading...
HomeMy WebLinkAboutR_401383M CD 0 i 0 LU I-_ 75 N 00 N L 0 z E 0 c 0 a� c� U) m J SITE SPECIFIC DATA PROJECT NAME 4851 — SOUTH SHORE OF LAKE WA — APRON R PROJECT LOCATION RENTON, WA STRUCTURE ID RTU-15 TREATMENT REQUIRED VOLUME BASED (CF) FLOW BASED (CFS) 0.183 TREATMENT HGL AVAILABLE (FT) N/A PEAK BYPASS REQUIRED (CFS) — IF APPLICABLE 0.712 PIPE DATA I.E. MATERIAL DIAMETER INLET PIPE 16.30 PVC 8" OUTLET PIPE 15.20 HOPE 12" PRETREATMENT BIOFILTRATION DISCHARGE RIM ELEVATION 18.74 18.74 18.74 SURFACE LOAD 120 KIPS 120 KIPS 120 KIPS FRAME & COVER (2) 36" X 36" (2) 36" X 74" (2) 36 X 36 (2) 30" X 30" INDUSTRIAL MEDIA VOLUME (CY) 5.70 INDUSTRIAL MEDIA DELIVERY METHOD PER CONTRACT ORIFICE SIZE (DIA. INCHES) (2) 0 1.93" NO TES: INSTALLATION NOTES 1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT MATERIALS AND INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE MANUFACTURERS SPECIFICATIONS, UNLESS OTHERWISE STATED IN MANUFACTURERS CONTRACT. 2. UNIT MUST BE INSTALLED ON LEVEL BASE. MANUFACTURER RECOMMENDS A MINIMUM 6" LEVEL ROCK BASE UNLESS SPECIFIED BY THE PROJECT ENGINEER. CONTRACTOR IS RESPONSIBLE TO VERIFY PROJECT ENGINEERS RECOMMENDED BASE SPECIFICATIONS. J. ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF CONCRETE. (PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF OUTFLOW PIPE MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR. ALL GAPS AROUND PIPES SHALL BE SEALED WATER TIGHT WITH A NON —SHRINK GROUT PER MANUFACTURERS STANDARD CONNECTION DETAIL AND SHALL MEET OR EXCEED REGIONAL PIPE CONNECTION STANDARDS. 4. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING PIPES. 5. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL RISERS, MANHOLES, AND HATCHES. CONTRACTOR TO GROUT ALL MANHOLES AND HATCHES TO MATCH FINISHED SURFACE UNLESS SPECIFIED OTHERWISE. 6. DRIP OR SPRAY IRRIGATION REQUIRED ON ALL UNITS WITH VEGETATION. GENERAL NOTES r I w T 16.34 16.30 OP 01 WEIR 16.18 6" 1. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED. 2. ALL DIMENSIONS, ELEVATIONS, SPECIFICATIONS AND CAPACITIES ARE SUBJECT TO CHANGE. FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS AND ACCESSORIES PLEASE CONTACT MANUFACTURER. PATENTED ldtli II1R/UL INFLOW PIPE SEE NOTES IVLLIVMII I vUIVUIII R-3498-R2S SPRING ASSIST HATCHES PLAN VIEW 12'-10" PRETREATMENT CHAMBER 4 24'-0" 25'-0" ELEVATION VIEW INTERNAL BYPASS DISCLOSURE: Wr. r `10'- 10"— DISCHARGE CHAMBER THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD TO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK FLOW SHALL BE ASSESSED TO ENSURE NO UPSTREAM FLOODING. PEAK HGL AND BYPASS CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY. LOW INFLOW PIPE DISCLOSURE: IT IS RECOMMENDED THAT A SUFFICIENT VARIATION IN ELEVATION BETWEEN THE INLET AND OUTLET BE PROVIDED TO ALLOW FOR ACCUMULATION OF SEDIMENT IN THE PRE—TREATMENT CHAMBER. FAILURE TO DO SO MAY RESULT IN BLOCKAGE AT INFLOW POINT(S) WHICH MAY CAUSE UPSTREAM FLOODING. NEENAH FOUNDRY R-3498—R3S SPRING I ASSIST HATCH L/Ull LU11 r-IrL SEE NOTES NEENAH FOUNDRY R-3498—P2S SPRING ASSIST HATCH 18.74 FLOW CONTROL RISER lE OUT 15.20 WATER TABLE 1 15.20 8" NEENAH FOUNDRY R-3498-R2S SPRING ASSIST HATCH o II 1 1 r7 N LEFT END VIEW NEENAH FOUNDRY R-3498—P2S SPRING ASSIST HATCH 6 lI 1 3'-8' -- 9'-4 " RIGHT END VIEW NEAR MODULAR WETLAND SYSTEM RTU-015 00-3D SCALE: NTS AIRCRAFT RATED HATCHES 72" X 36" DOUBLE NEENAH R-3498—R3S 62" X 36" DOUBLE EAST JORDAN 8196—DOUBLE 36" X 36" SINGLE NEENAH R-3498—R2S 24" DIA ROUND NEENAH R-3492 NOTES: 1. ALL VAULT STRUCTURES AND ASSOCIATED ACCESS LIDS AND HATCHES SHALL MEET THE DESIGN LOADING REQUIREMENTS SHOWN ON SHEET G3. 2. THE LIFTING FORCE REQUIRED TO OPEN ACCESS LIDS AND HATCHES SHALL BE A MAXIMUM OF 35—POUNDS. HINGED LIDS AND ACCESS HATCHES SHALL BE EQUIPPED WITH A HYDRAULIC LIFT ASSIST SYSTEM AS REQUIRED TO MEET THE MAXIMUM LIFTING FORCE REQUIREMENTS. 3. MODULAR WETLAND FRAMES, HATCHES, AND LIDS SHALL BE AS SHOWN IN THE TABLE ABOVE OR ENGINEER APPROVED EQUAL. 4. PERMANENT WATER QUALITY TREATMENT FACILITIES SHALL NOT BE USED TO CONVEY OR CONTAIN CONSTRUCTION STORM WATER. NEW FACILITIES SHALL BE KEPT OFFLINE UNTIL PROJECT IS COMPLETE. THE CONTRACTOR SHALL CLEAN AND FLUSH ALL PARTS OF THE SYSTEM PRIOR. SEE GENERAL NOTES ON SHEET G2. 5. SEE STRUCTURAL PLANS FOR STRUCTURAL SUPPORT DETAIL. BergerABAM 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 (206) 431-2300 Fax:(206) 431-2250 CIVIL PERMIT R-401383 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Fr12/20/2018 WATER UTILITY afowler 12/20/201801 a Ul SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE UNAWN UAI E SUBTITLE CURRENT REVISION SYMBOL DATE ~�N P. THIS DESIGN B AND/OR CHECKED 06 08 18 STORM DRAINAGE DETAILS - SHEET 11 W4700331 A 10/01 / 18 APRON R INFRASTRUCTURE W4700331 ABAM SPT 06/08/18 T� SPT 06 08 18 SHEET w of WAsx�� G SPECIFICATION IS APPROVED A CITY OF RENTON COMMENTS W4700331 ABAM SPT 10/01/18 ® ODP� c°> APPROVED BY DEPT. I DATE BEE 06 08 18 TITLE APRON R INFRASTRUCTURE LCHECKED C500-3W C66 31271 RENTON SITE JOB No. W4700331 COMP No. ���SIDNAL APPROVED APPROVED CIVIL MASTER SITE RENTON, WA DWG No. 4-APRON-R-0500-3W